Concurrent validation of the Actigraph gt3x+, Polar Active accelerometer, Omron HJ-720 and Yamax Digiwalker SW-701 pedometer step counts in lab-based and free-living settings
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Activity monitors are frequently used to assess activity in many settings. But as technology advances, so do the mechanisms used to estimate activity causing a continuous need to validate newly developed monitors. The purpose of this study was to examine the step count validity of the Yamax Digiwalker SW-701 pedometer (YX), Omron HJ-720 T pedometer (OP), Polar Active accelerometer (PAC) and Actigraph gt3x+ accelerometer (AG) under controlled and free-living conditions. Participants completed five stages of treadmill walking (n = 43) and a subset of these completed a 3-day free-living wear period (n = 37). Manually counted (MC) steps provided a criterion measure for treadmill walking, whereas the comparative measure during free-living was the YX. During treadmill walking, the OP was the most accurate monitor across all speeds (±1.1% of MC steps), while the PAC underestimated steps by 6.7-16.0% per stage. During free-living, the OP and AG counted 97.5% and 98.5% of YX steps, respectively. The PAC overestimated steps by 44.0%, or 5,265 steps per day. The Omron pedometer seems to provide the most reliable and valid estimate of steps taken, as it was the best performer under lab-based conditions and provided comparable results to the YX in free-living. Future studies should consider these monitors in additional populations and settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785 · cited 1×
“Additionally, Lin’s concordance coefficients were utilised to assess the measure of agreement between the monitors (Lin, 1989, 2000).”
MethodThe pandemic of physical inactivity: global action for public health
Kohl, H. W., Craig, C. L., Lambert, E. V., Inoue, S., Alkandari, J. R., Leetongin, G., & Kahlmeier, S. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60898-8 · Cited by 2,985 · cited 1×
“Physical inactivity (Kohl et al., 2012) and exercisedeficit disorder (Stracciolini, Myer, & Faigenbaum, 2013) are terms developed to describe the sedentary culture that has evolved in the United States.”
BackgroundPhysical Activity, All-Cause Mortality, and Longevity of College Alumni
Paffenbarger, R. S., Hyde, R., Wing, A. L., & Hsieh, C.-C. (1986) · New England Journal of Medicine · doi:10.1056/nejm198603063141003 · Cited by 2,742
How Many Steps/Day Are Enough?: Preliminary Pedometer Indices for Public Health
Tudor-Locke, C., & Bassett, D. R. (2004) · Sports Medicine · doi:10.2165/00007256-200434010-00001 · Cited by 2,054
Hamilton, M. T., Hamilton, D. G., & Zderic, T. W. (2007) · Diabetes · doi:10.2337/db07-0882 · Cited by 1,655
Sedentary Behaviors and Subsequent Health Outcomes in Adults
Thorp, A. A., Owen, N., Neuhaus, M., & Dunstan, D. W. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2011.05.004 · Cited by 1,455
Vincent, W. J. (1994) · Cited by 1,016
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899 · cited 4×
“…findings were similar to previous research showing that the YX underestimates steps at slower speeds but becomes more accurate as speed increases (Crouter et al., 2003; Schneider et al., 2003, 2004), while the OP possesses high accuracy during treadmill walking at all speeds (Dondzila et al.,…”
MethodResultInfluentialPedometer Measures of Free-Living Physical Activity: Comparison of 13 Models
SCHNEIDER, P. L., CROUTER, S. E., & BASSETT, D. R. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113486.60548.e9 · Cited by 752 · cited 4×
“However, the present study utilised the YX, which is commonly used in free-living settings as a referent monitor for counting steps (Schneider et al., 2004), and selected a sample that the YX accurately estimates step counts in Crouter et al.”
MethodResultInfluentialAccuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
SCHNEIDER, P. L., CROUTER, S. E., LUKAJIC, O., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089342.96098.c4 · Cited by 633 · cited 4×
“…to previous research showing that the YX underestimates steps at slower speeds but becomes more accurate as speed increases (Crouter et al., 2003; Schneider et al., 2003, 2004), while the OP possesses high accuracy during treadmill walking at all speeds (Dondzila et al., 2012; Holbrook,…”
MethodResultInfluential
Cited by
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
“[173] Wrist Discontinued 2011 Active Polar”
BackgroundLong-term unsupervised mobility assessment in movement disorders
Warmerdam, E., Hausdorff, J. M., Atrsaei, A., Zhou, Y., Mirelman, A., Aminian, K., Espay, A. J., Hansen, C., Evers, L. J. W., Keller, A., et al. (2020) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30397-7 · Cited by 306
Sushames, A., Edwards, A., Thompson, F., McDermott, R., & Gebel, K. (2016) · PLOS ONE · doi:10.1371/journal.pone.0161224 · Cited by 152
Vetrovsky, T., Siranec, M., Marencakova, J., Tufano, J. J., Capek, V., Bunc, V., & Belohlavek, J. (2019) · PLOS ONE · doi:10.1371/journal.pone.0222569 · Cited by 53
Khunti, K., Griffin, S., Brennan, A., Dallosso, H., Davies, M. J., Eborall, H. C., Edwardson, C. L., Gray, L. J., Hardeman, W., Heathcote, L., et al. (2021) · BMC Medicine · doi:10.1186/s12916-021-01997-4 · Cited by 39
Zemet, R., Schiff, E., Manovitch, Z., Cahan, T., Yoeli-Ullman, R., Brandt, B., Hendler, I., Dorfman-Margolis, L., Yinon, Y., Sivan, E., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0198949 · Cited by 23
Yates, T., Sargeant, J. A., King, J. A., Henson, J., Edwardson, C. L., Redman, E., Gulsin, G. S., Brady, E. M., Ahmad, E., Stensel, D. J., et al. (2022) · Diabetes Care · doi:10.2337/dc22-0888 · Cited by 9
Metadata
- Authors
- Lee, J. A., Williams, S. M., Brown, D. D., & Laurson, K. R.
- Venue
- Journal of Sports Sciences
- Publisher
- Informa UK Limited
- Published
- 2014-12-17
- Volume
- 33
- Issue
- 10
- Pages
- 991-1000
- ISSN
- 0264-0414 (ISSN-L)
- 1466-447X
- OpenAlex
- W2036282362
- Cited by
- 169
- References
- 31
- FWCI
- 7.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.