Evaluation of the TEOM® Method for Measurement of Ambient Particulate Mass in Urban Areas
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Increased interest in the health effects of ambient particulate mass (PM) has focused attention on the evaluation of existing mass measurement methodologies and the definition of PM in ambient air. The Rupprecht and Patashnick Tapered Element Oscillating MicroBalance (TEOM) method for PM is compared with time-integrated gravimetric (manual) PM methods in large urban areas during different seasons. Comparisons are conducted for both PM10 and PM2.5 concentrations. In urban areas, a substantial fraction of ambient PM can be semi-volatile material. A larger fraction of this component of PM10 may be lost from the TEOM-heated filter than the Federal Reference Method (FRM). The observed relationship between TEOM and FRM methods varied widely among sites and seasons. In East Coast urban areas during the summer, the methods were highly correlated with good agreement. In the winter, correlation was somewhat lower, with TEOM PM concentrations generally lower than the FRM. Rubidoux, CA, and two Mexican sites (Tlalnepantla and Merced) had the highest levels of PM10 and the largest difference between TEOM and manual methods. PM2.5 data from collocation of 24-hour manual samples with the TEOM are also presented. As most of the semi-volatile PM is in the fine fraction, differences between these methods are larger for PM2.5 than for PM10.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Particulate air pollution as a predictor of mortality in a prospective study of U.S. adults.
Pope, C. A., Thun, M. J., Namboodiri, M. M., Dockery, D. W., Evans, J. S., Speizer, F. E., & Heath, C. W. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.151.3.7881654 · Cited by 2,911
Acute Respiratory Effects of Particulate Air Pollution
Dockery, D. W., & Pope, C. A. (1994) · Annual Review of Public Health · doi:10.1146/annurev.pu.15.050194.000543 · Cited by 2,177
Atmospheric chemistry : fundamentals and experimental techniques
Finlayson‐Pitts, B. J., & PITTS, J. N. J. (1986) · John Wiley and Sons Inc.,New York, NY eBooks · Cited by 1,089
Air Pollution and Daily Mortality: A Review and Meta Analysis
Schwartz, J. (1994) · Environmental Research · doi:10.1006/enrs.1994.1005 · Cited by 884
Continuous PM-10 Measurements Using the Tapered Element Oscillating Microbalance
Patashnick, H., & Rupprecht, E. G. (1991) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1991.10466903 · Cited by 398
Low Flow Rate Sharp Cut Impactors for Indoor Air Sampling: Design and Calibration
Marple, V. A., Rubow, K. L., Turner, W., & Spengler, J. D. (1987) · JAPCA · doi:10.1080/08940630.1987.10466325 · Cited by 241
A neighborhood-scale study of PM10 source contributions in Rubidoux, California
Chow, J. C., Liu, C. S., Cassmassi, J., Watson, J. G., Lu, Z., & Pritchett, L. C. (1992) · Atmospheric Environment Part A General Topics · doi:10.1016/0960-1686(92)90181-j · Cited by 77
Cited by
Van Dingenen, R., Raes, F., Putaud, J.-P., Baltensperger, U., Charron, A., Facchini, M.-C., Decesari, S., Fuzzi, S., Gehrig, R., Hansson, H.-C., et al. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.01.040 · Cited by 1,011
Visibility: Science and Regulation
Watson, J. G. (2002) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2002.10470813 · Cited by 929
Ambient Pollution and Heart Rate Variability
Gold, D. R., Litonjua, A., Schwartz, J., Lovett, E., Larson, A., Nearing, B., Allen, G., Verrier, M., Cherry, R., & Verrier, R. (2000) · Circulation · doi:10.1161/01.cir.101.11.1267 · Cited by 868
Self-citationStandardized Loads Acting in Hip Implants
Bergmann, G., Bender, A., Dymke, J., Duda, G., & Damm, P. (2016) · PLOS ONE · doi:10.1371/journal.pone.0155612 · Cited by 562
PETERS, J. M., AVOL, E., GAUDERMAN, W. J., LINN, W. S., NAVIDI, W., LONDON, S. J., MARGOLIS, H., RAPPAPORT, E., VORA, H., GONG, H., et al. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.3.9804144 · Cited by 518
Characterisation of PM10 and PM2.5 particulate matter in the ambient air of Milan (Italy)
Marcazzan, G. M., Vaccaro, S., Valli, G., & Vecchi, R. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00124-8 · Cited by 514
Association between PM2.5 and all-cause and specific-cause mortality in 27 US communities
Franklin, M., Zeka, A., & Schwartz, J. (2007) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jes.7500530 · Cited by 466
Long, C. M., Suh, H. H., Catalano, P. J., & Koutrakis, P. (2001) · Environmental Science & Technology · doi:10.1021/es001477d · Cited by 443
Self-citationStandardized Loads Acting in Knee Implants
Bergmann, G., Bender, A., Graichen, F., Dymke, J., Rohlmann, A., Trepczynski, A., Heller, M. O., & Kutzner, I. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086035 · Cited by 382
PETERS, J. M., AVOL, E., NAVIDI, W., LONDON, S. J., GAUDERMAN, W. J., LURMANN, F., LINN, W. S., MARGOLIS, H., RAPPAPORT, E., GONG, H., et al. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.3.9804143 · Cited by 371
Self-citationCharacterization of Indoor Particle Sources Using Continuous Mass and Size Monitors
Long, C. M., Suh, H. H., & Koutrakis, P. (2000) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2000.10464154 · Cited by 364
Self-citationEffects of Air Pollution on Heart Rate Variability: The VA Normative Aging Study
Park, S. K., O’Neill, M. S., Vokonas, P. S., Sparrow, D., & Schwartz, J. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7447 · Cited by 360
Air pollution and emergency admissions in Boston, MA
Zanobetti, A., & Schwartz, J. (2006) · Journal of Epidemiology and Community Health · doi:10.1136/jech.2005.039834 · Cited by 263
Monitoring of particulate matter outdoors
Wilson, W. E., Chow, J. C., Claiborn, C., Fusheng, W., Engelbrecht, J., & Watson, J. G. (2002) · Chemosphere · doi:10.1016/s0045-6535(02)00270-9 · Cited by 231
“Moreover, they suggested that this difference is likely to be larger for PM2:5 than it is for PM10 (Allen et al., 1997).”
BackgroundInfluentialBi, J., Wildani, A., Chang, H. H., & Liu, Y. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.9b06046 · Cited by 227
Charron, A., & Harrison, R. M. (2005) · Environmental Science & Technology · doi:10.1021/es050462i · Cited by 215
Schwartz, J., Park, S. K., O'Neill, M. S., Vokonas, P. S., Sparrow, D., Weiss, S., & Kelsey, K. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200412-1698oc · Cited by 214
“a season-specific correction to compensate for the loss of semivolatile mass (40).”
BackgroundSaarikoski, S., Sillanpää, M., Sofiev, M., Timonen, H., Saarnio, K., Teinilä, K., Karppinen, A., Kukkonen, J., & Hillamo, R. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.12.053 · Cited by 209
“5–10 were measured with two Tapered Element Oscillating Microbalance units (TEOMr, Rupprecht & Patashnick; Allen et al., 1997; Patashnick and Rupprecht, 1991).”
MethodDelfino, R. J., Zeiger, R. S., Seltzer, J. M., Street, D. H., & McLaren, C. E. (2002) · Environmental Health Perspectives · doi:10.1289/ehp.021100607 · Cited by 208
“An additional weakness in the PM exposure metric is that TEOM measurements of PM10 could have potentially underestimated concentrations at key times because of the expected volatilization of important semivolatile particle components as they cross the 50°C heating element (23).”
BackgroundInflammatory markers and particulate air pollution: characterizing the pathway to disease
Zeka, A., Sullivan, J. R., Vokonas, P. S., Sparrow, D., & Schwartz, J. (2006) · International Journal of Epidemiology · doi:10.1093/ije/dyl132 · Cited by 205
Levels of particulate matter in rural, urban and industrial sites in Spain
Querol, X., Alastuey, A., Rodrı́guez, S., Viana, M. M., Artı́ñano, B., Salvador, P., Mantilla, E., do Santos, S. G., Patier, R. F., de La Rosa, J., et al. (2004) · Science of The Total Environment · doi:10.1016/j.scitotenv.2004.04.036 · Cited by 177
Querol, X., Alastuey, A., Rosa, J. D. L., Sánchez-de-la-Campa, A., Plana, F., & Ruiz, C. R. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00257-1 · Cited by 165
“However, it has to be pointed out in recent studies that TEOM and beta attenuation measurements may underestimate PM10 with respect to the conventional gravimetric method (Allen et al., 1997; APEG, 1999; European Commission, 2001) by as much as 30wt%.”
BackgroundBurkart, J., Steiner, G., Reischl, G., Moshammer, H., Neuberger, M., & Hitzenberger, R. (2010) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2010.07.007 · Cited by 160
Patella, V., Florio, G., Palmieri, M., Bousquet, J., Tonacci, A., Giuliano, A., & Gangemi, S. (2020) · Pediatric Allergy and Immunology · doi:10.1111/pai.13314 · Cited by 54
Metadata
- Authors
- Allen, G., Sioutas, C., Koutrakis, P., Reiss, R., Lurmann, F. W., & Roberts, P. T.
- Venue
- Journal of the Air & Waste Management Association
- Publisher
- Informa UK Limited
- Published
- 1997-06
- Volume
- 47
- Issue
- 6
- Pages
- 682-689
- ISSN
- 1047-3289 (ISSN-L)
- 1096-2247
- 2162-2906
- OpenAlex
- W2159862336
- Cited by
- 273
- References
- 7
- FWCI
- 7.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.