Characterization of Indoor Particle Sources Using Continuous Mass and Size Monitors
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A comprehensive indoor particle characterization study was conducted in nine Boston-area homes in 1998 in order to characterize sources of PM in indoor environments. State-of-the-art sampling methodologies were used to obtain continuous PM2.5 concentration and size distribution particulate data for both indoor and outdoor air. Study homes, five of which were sampled during two seasons, were monitored over week-long periods. Among other data collected during the extensive monitoring efforts were 24-hr elemental/organic carbon (EC/OC) particulate data as well as semi-continuous air exchange rates and time-activity information. This rich data set shows that indoor particle events tend to be brief, intermittent, and highly variable, thus requiring the use of continuous instrumentation for their characterization. In addition to dramatically increasing indoor PM2.5 concentrations, these data demonstrate that indoor particle events can significantly alter the size distribution and composition of indoor particles. Source event data demonstrate that the impacts of indoor activities are especially pronounced in the ultrafine (da < or = 0.1 micron) and coarse (2.5 < or = da < or = 10 microns) modes. Among the sources of ultrafine particles characterized in this study are indoor ozone/terpene reactions. Furthermore, EC/OC data suggest that organic carbon is a major constituent of particles emitted during indoor source events. Whether exposures to indoor-generated particles, particularly from large short-term peak events, may be associated with adverse health effects will become clearer when biological mechanisms are better known.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An association between air pollution and mortality in six U.S. cities
Dockery, D. W., Pope, C. A., Xu, X., Spengler, J. D., Ware, J. H., Fay, M. E., Ferris, B. G., & Speizer, F. E. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312093292401 · Cited by 8,018
Is Daily Mortality Associated Specifically with Fine Particles?
Schwartz, J., Dockery, D. W., & Neas, L. M. (1996) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1996.10467528 · Cited by 1,561
Atmospheric chemistry : fundamentals and experimental techniques
Finlayson‐Pitts, B. J., & PITTS, J. N. J. (1986) · John Wiley and Sons Inc.,New York, NY eBooks · Cited by 1,089
Continuous PM-10 Measurements Using the Tapered Element Oscillating Microbalance
Patashnick, H., & Rupprecht, E. G. (1991) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1991.10466903 · Cited by 398
Evaluation of the TEOM® Method for Measurement of Ambient Particulate Mass in Urban Areas
Allen, G., Sioutas, C., Koutrakis, P., Reiss, R., Lurmann, F. W., & Roberts, P. T. (1997) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1997.10463923 · Cited by 273
Self-citationLow Flow Rate Sharp Cut Impactors for Indoor Air Sampling: Design and Calibration
Marple, V. A., Rubow, K. L., Turner, W., & Spengler, J. D. (1987) · JAPCA · doi:10.1080/08940630.1987.10466325 · Cited by 241
Lioy, P. J., Wainman, T., Turner, W., & Marple, V. A. (1988) · JAPCA · doi:10.1080/08940630.1988.10466408 · Cited by 31
Cited by
What are the sources of exposure to eight frequently used phthalic acid esters in Europeans?
Wormuth, M., Scheringer, M., Vollenweider, M., & Hungerbühler, K. (2006) · Risk Analysis · doi:10.1111/j.1539-6924.2006.00770.x · Cited by 1,025
Cleaning products and air fresheners: exposure to primary and secondary air pollutants
Nazaroff, W. W., & Weschler, C. J. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.02.040 · Cited by 846
Nazaroff, W. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00286.x · Cited by 639
Contribution from indoor sources to particle number and mass concentrations in residential houses
HE, C. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.03.027 · Cited by 585
Abdullahi, K. L., Delgado-Saborit, J. M., & Harrison, R. M. (2013) · Atmospheric Environment · doi:10.1016/j.atmosenv.2013.01.061 · Cited by 565
“The physical stirring of food has 147 been found to lead to the generation of large aerosols due to the process of splashing of the 148 ingredients (Long et al., 2000).”
BackgroundWeschler, C. J. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.9256 · Cited by 481
Sources of airborne microorganisms in the built environment
Prussin, A. J., & Marr, L. C. (2015) · Microbiome · doi:10.1186/s40168-015-0144-z · Cited by 453
Research on aerosol sources and chemical composition: Past, current and emerging issues
Calvo, A. I., Alves, C., Castro, A., Pont, V., Vicente, A. M., & Fraile, R. (2013) · Atmospheric Research · doi:10.1016/j.atmosres.2012.09.021 · Cited by 446
Indoor aerosols: from personal exposure to risk assessment
Morawska, L., Afshari, A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Hänninen, O., Hofmann, W., Isaxon, C., Jayaratne, E. R., Pasanen, P., et al. (2013) · Indoor Air · doi:10.1111/ina.12044 · Cited by 442
Zhang, Z., & Chen, Q. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.01.014 · Cited by 422
Wolkoff, P., Wilkins, C. K., Clausen, P. A., & Nielsen, G. D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00393.x · Cited by 348
Child exposure to indoor and outdoor air pollutants in schools in Barcelona, Spain
Rivas, I., Viana, M., Moreno, T., Pandolfi, M., Amato, F., Reche, C., Bouso, L., Àlvarez-Pedrerol, M., Alastuey, A., Sunyer, J., et al. (2014) · Environment International · doi:10.1016/j.envint.2014.04.009 · Cited by 345
“…pollutants (that might differ in every school because of different building characteristics; Adgate et al., 2003; Dockery and Spengler, 1981) and on indoor-sourced PM (which might also be different in schools depending on the activities that take place; Kopperud et al., 2004; Long et al., 2000).”
BackgroundIndoor secondary pollutants from cleaning product and air freshener use in the presence of ozone
Singer, B. C., Coleman, B. K., Destaillats, H., Hodgson, A. T., Lunden, M. M., Weschler, C. J., & Nazaroff, W. W. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.06.005 · Cited by 330
Walking-induced particle resuspension in indoor environments
Qian, J., Peccia, J., & Ferro, A. R. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.02.035 · Cited by 305
Personal Exposure to Ultrafine Particles and Oxidative DNA Damage
Vinzents, P. S., Møller, P., Sørensen, M., Knudsen, L. E., Hertel, O., Jensen, F. P., Schibye, B., & Loft, S. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7562 · Cited by 288
Logue, J. M., McKone, T. E., Sherman, M. H., & Singer, B. C. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00683.x · Cited by 266
Sanderson, J. T., Letcher, R. J., Heneweer, M., Giesy, J. P., & van den Berg, M. (2001) · Environmental Health Perspectives · doi:10.1289/ehp.011091027 · Cited by 260
Braniš, M., Řezáčová, P., & Domasová, M. (2005) · Environmental Research · doi:10.1016/j.envres.2004.12.001 · Cited by 249
Linking exposure to environmental pollutants with biological effects
Sørensen, M., Autrup, H., Møller, P., Hertel, O., Jensen, S. S., Vinzents, P., Knudsen, L. E., & Loft, S. (2003) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2003.06.010 · Cited by 237
Yang, F., Ding, J., Huang, W., Xie, W., & Liu, W. (2014) · Environmental Science & Technology · doi:10.1021/es403186z · Cited by 228
Indoor Air Pollution and Asthma in Children
Breysse, P. N., Diette, G. B., Matsui, E. C., Butz, A. M., Hansel, N. N., & McCormack, M. C. (2010) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200908-083rm · Cited by 228
Sarnat, J. A., Koutrakis, P., & Suh, H. H. (2000) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2000.10464165 · Cited by 227
Self-citationJanssen, N. A. H., Schwartz, J., Zanobetti, A., & Suh, H. H. (2002) · Environmental Health Perspectives · doi:10.1289/ehp.0211043 · Cited by 226
“Air exchange rates are generally lower in winter than in summer because people keep their windows closed (20), so use of outdoor concentrations could cause higher exposure misclassification in cities with winter peaking PM10 concentrations compared to cities with nonwinter peaking PM10 concentrations.”
BackgroundSelf-citationIndoor Particulate Matter during HOMEChem: Concentrations, Size Distributions, and Exposures
Patel, S., Sankhyan, S., Boedicker, E. K., DeCarlo, P. F., Farmer, D. K., Goldstein, A. H., Katz, E. F., Nazaroff, W. W., Tian, Y., Vanhanen, J., et al. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c00740 · Cited by 214
Gaseous pollutants in particulate matter epidemiology: confounders or surrogates?
Sarnat, J. A., Schwartz, J., Catalano, P. J., & Suh, H. H. (2001) · Environmental Health Perspectives · doi:10.1289/ehp.011091053 · Cited by 212
Self-citationAllen, R., Larson, T., Sheppard, L., Wallace, L., & Liu, L.-J. S. (2003) · Environmental Science & Technology · doi:10.1021/es021007e · Cited by 205
Exposure to Ambient and Nonambient Components of Particulate Matter: A Comparison of Health Effects
Ebelt, S. T., Wilson, W. E., & Brauer, M. (2005) · Epidemiology · doi:10.1097/01.ede.0000158918.57071.3e · Cited by 196
de Gennaro, G., Dambruoso, P. R., Loiotile, A. D., Di Gilio, A., Giungato, P., Tutino, M., Marzocca, A., Mazzone, A., Palmisani, J., & Porcelli, F. (2014) · Environmental Chemistry Letters · doi:10.1007/s10311-014-0470-6 · Cited by 178
Elevated personal exposure to particulate matter from human activities in a residence
Ferro, A. R., Kopperud, R. J., & Hildemann, L. M. (2004) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500356 · Cited by 174
“A few studies have directly examined the effect of specific human activities on indoor PM concentrations (Thatcher and Layton, 1995; Long et al., 2000).”
BackgroundResultInfluentialWei See, S., Karthikeyan, S., & Balasubramanian, R. (2006) · Journal of Environmental Monitoring · doi:10.1039/b516173h · Cited by 169
Morawska, L. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(03)00566-1 · Cited by 166
Criteria air pollutants and toxic air pollutants.
Suh, H. H., Bahadori, T., Vallarino, J., & Spengler, J. D. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.00108s4625 · Cited by 159
Self-citationSources of indoor air pollution in New York City residences of asthmatic children
Habre, R., Coull, B., Moshier, E., Godbold, J., Grunin, A., Nath, A., Castro, W., Schachter, N., Rohr, A., Kattan, M., et al. (2014) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2013.74 · Cited by 158
Self-citationBhangar, S., Mullen, N. A., Hering, S. V., Kreisberg, N. M., & Nazaroff, W. W. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00689.x · Cited by 158
Particle Resuspension During the Use of Vacuum Cleaners on Residential Carpet
Corsi, R. L., Siegel, J. A., & Chiang, C. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620801901165 · Cited by 111
Peng, Z., Deng, W., & Tenorio, R. (2017) · Sustainability · doi:10.3390/su9071180 · Cited by 109
“[13] investigated nine homes in Boston and figured out that dusting, vigorous walking, and sautéing were the key factors affecting indoor air quality.”
BackgroundMullen, N. A., Bhangar, S., Hering, S. V., Kreisberg, N. M., & Nazaroff, W. W. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00690.x · Cited by 90
Kopperud, R. J., Ferro, A. R., & Hildemann, L. M. (2004) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2004.10470983 · Cited by 61
Metadata
- Authors
- Long, C. M., Suh, H. H., & Koutrakis, P.
- Venue
- Journal of the Air & Waste Management Association
- Publisher
- Informa UK Limited
- Published
- 2000-07
- Volume
- 50
- Issue
- 7
- Pages
- 1236-1250
- ISSN
- 1047-3289 (ISSN-L)
- 1096-2247
- 2162-2906
- OpenAlex
- W2045050634
- Cited by
- 364
- References
- 7
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.