An Overview on Assessing Agreement with Continuous Measurements
The DOI matches its Crossref record; 99 of the 99 references it cites were found in a registry or an index.
Abstract
Reliable and accurate measurements serve as the basis for evaluation in many scientific disciplines. Issues related to reliable and accurate measurement have evolved over many decades, dating back to the nineteenth century and the pioneering work of Galton (1886), Pearson (1896, 1899, 1901), and Fisher (1925). Requiring a new measurement to be identical to the truth is often impractical, either because (1) we are willing to accept a measurement up to some tolerable (or acceptable) error, or (2) the truth is simply not available to us, either because it is not measurable or is only measurable with some degree of error. To deal with issues related to both (1) and (2), a number of concepts, methods, and theories have been developed in various disciplines. Some of these concepts have been used across disciplines, while others have been limited to a particular field but may have potential uses in other disciplines. In this paper, we elucidate and contrast fundamental concepts employed in different disciplines and unite these concepts into one common theme: assessing closeness (agreement) of observations. We focus on assessing agreement with continuous measurements and classify different statistical approaches as (1) descriptive tools; (2) unscaled summary indices based on absolute differences of measurements; and (3) scaled summary indices attaining values between -1 and 1 for various data structures, and for cases with and without a reference. We also identify gaps that require further research and discuss future directions in assessing agreement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398 · cited 2×
“…− Yi2k|δ|Yi1k′ − Yi2k′|δ] EI [ ∑p k=1 ∑p k′=1 dkk′|Yi1k − Yi2k|δ|Yi1k′ − Yi2k′|δ] , where it reduces to the repeated measures CCC if δ = 1 and to a parameter comparable to repeated measures version of kappa (Cohen, 1960, 1968) index for assessing agreement between categorical measurements if δ = 0.”
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Statistical Methods for Research Workers
(1945) · American Journal of Clinical Pathology · doi:10.1093/ajcp/15.11.552b · Cited by 10,880
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 12×
“The LOA method has also been extended to data with replications or with repeated measures (Bland and Altman, 1999; Bland and Altman, 2007).”
BackgroundMethodInfluentialMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785 · cited 10×
“For the special case of J = 2 and K = 1, Lin (1989) defined ρ12 = corr(Yi1, Yi2) and χa = 2σ1σ2/(2σ1σ2 +(µ1−µ2)2+(σ1−σ2)2) as the precision and accuracy components of the CCC, respectively.”
BackgroundMethodInfluentialSelf-citationWeighted kappa: nominal scale agreement provision for scaled disagreement or partial credit
Cohen, J. (1968) · Psychological Bulletin · doi:10.1037/h0026256 · Cited by 8,736 · cited 1×
“…− Yi2k|δ|Yi1k′ − Yi2k′|δ] EI [ ∑p k=1 ∑p k′=1 dkk′|Yi1k − Yi2k|δ|Yi1k′ − Yi2k′|δ] , where it reduces to the repeated measures CCC if δ = 1 and to a parameter comparable to repeated measures version of kappa (Cohen, 1960, 1968) index for assessing agreement between categorical measurements if δ = 0.”
Statistical Theories of Mental Test Scores
Rozeboom, W. W., Lord, F. M., Novick, M. R., & Birnbaum, A. (1969) · American Educational Research Journal · doi:10.2307/1162101 · Cited by 8,022
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903 · cited 16×
“We do not present ICCs for averaged observations (Shout and Fleiss, 1979; McGraw and Wong, 1996), as we are interested in agreement between single observations.”
BackgroundMethodInfluential
Cited by
Bock, C. H., Poole, G. H., Parker, P. E., & Gottwald, T. R. (2010) · Critical Reviews in Plant Sciences · doi:10.1080/07352681003617285 · Cited by 964
Mobile Health Technology Evaluation
Kumar, S., Nilsen, W. J., Abernethy, A., Atienza, A., Patrick, K., Pavel, M., Riley, W. T., Shar, A., Spring, B., Spruijt-Metz, D., et al. (2013) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2013.03.017 · Cited by 900
“As with any measure, before mHealth assessment methods can be recommended, their reliability and validity must be established.(13) Table 2 highlights the goals and challenges of attaining reliability and validity in mHealth assessments, not the least of which is the rapid evolution of device technologies that may affe…”
MethodZuo, X.-N., & Xing, X.-X. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2014.05.009 · Cited by 660
Raunig, D. L., McShane, L. M., Pennello, G., Gatsonis, C., Carson, P. L., Voyvodic, J. T., Wahl, R. L., Kurland, B. F., Schwarz, A. J., Gönen, M., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537344 · Cited by 394
Charlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366
Kessler, L. G., Barnhart, H. X., Buckler, A. J., Choudhury, K. R., Kondratovich, M. V., Toledano, A., Guimaraes, A. R., Filice, R., Zhang, Z., Sullivan, D. C., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537333 · Cited by 293
Self-citation3D Variation in delineation of head and neck organs at risk
Brouwer, C. L., Steenbakkers, R. J., van den Heuvel, E., Duppen, J. C., Navran, A., Bijl, H. P., Chouvalova, O., Burlage, F. R., Meertens, H., Langendijk, J. A., et al. (2012) · Radiation Oncology · doi:10.1186/1748-717x-7-32 · Cited by 211
“[11], the ICC was calculated as the ratio of the sum of variance components for patient and time-patient interaction effects and the sum of all variance components.”
Douglas, P. S., DeCara, J. M., Devereux, R. B., Duckworth, S., Gardin, J. M., Jaber, W. A., Morehead, A. J., Oh, J. K., Picard, M. H., Solomon, S. D., et al. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.05.020 · Cited by 207
Mehta, S., Bastero‐Caballero, R. F., Sun, Y., Zhu, R., Murphy, D. K., Hardas, B., & Koch, G. (2018) · Statistics in Medicine · doi:10.1002/sim.7679 · Cited by 193
“It has been shown that under fixed σ(2)b þ σ(2)ab þ σ(2)ε , both ICC and CCC increase as σ(2)a increases; hence, like ICC, subject distribution also has on an impact on the CCC.(31) However, the formulation of CCC for 2 raters(34) as well as its extension for multiple raters(36) suggest that the observed grades are fr…”
BackgroundInfluentialMeignan, M., Sasanelli, M., Casasnovas, R. O., Luminari, S., Fioroni, F., Coriani, C., Masset, H., Itti, E., Gobbi, P. G., Merli, F., et al. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2705-y · Cited by 186
Quantitative imaging biomarkers: A review of statistical methods for computer algorithm comparisons
Obuchowski, N. A., Reeves, A. P., Huang, E. P., Wang, X.-F., Buckler, A. J., Kim, H. J. (., Barnhart, H. X., Jackson, E. F., Giger, M. L., Pennello, G., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537390 · Cited by 172
“’s study.(34) A widely accepted method for comparing a QIB algorithm relative to the true value is the 95% LOAs proposed by Bland and Altman(30) under the normality assumption on the difference Yi Xi.”
MethodSelf-citationPauley, D., Cuijpers, P., Papola, D., Miguel, C., & Karyotaki, E. (2021) · Psychological Medicine · doi:10.1017/s0033291721001999 · Cited by 170
“Interrater reliability was calculated and reported using the interclass correlation coefficient (ICC) and Cohen ’ s Kappa (Banerjee, Capozzoli, McSweeney, & Sinha, 1999; Barnhart, Haber, & Lin, 2007; Cohen, 1968).”
Broderick, J. E., Schneider, S., Junghaenel, D. U., Schwartz, J. E., & Stone, A. A. (2013) · Arthritis Care & Research · doi:10.1002/acr.22025 · Cited by 158
“We computed a difference score between the 2 methods for each individual and week and estimated the percent of difference scores exceeding an MCID value, assuming a normal distribution of the difference scores (20).”
BackgroundMethodScott, E. P., Sorrell, A., & Benitez, A. (2019) · Journal of the International Neuropsychological Society · doi:10.1017/s1355617719000614 · Cited by 69
“Barnhart et al. (2007) and Carrasco and Jover (2003) demonstrated that the CCC is identical to the intraclass correlation coefficient (ICC; McGraw & Wong, 1996) when assumptions for the latter are met; however, the CCC is more appropriate when comparing two measures that may have different…”
BackgroundDehkordi, P., Garde, A., Molavi, B., Ansermino, J. M., & Dumont, G. A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00948 · Cited by 66
“The coverage probability (CP2) was also reported as the probability of measurement error falling within pre-defined bounds, set as 2 breaths per minute (bpm) in this study (Barnhart et al., 2007).”
Metadata
- Authors
- Barnhart, H. X., Haber, M. J., & Lin, L. I.
- Venue
- Journal of Biopharmaceutical Statistics
- Publisher
- Informa UK Limited
- Published
- 2007-07-02
- Volume
- 17
- Issue
- 4
- Pages
- 529-569
- ISSN
- 1054-3406 (ISSN-L)
- 1520-5711
- OpenAlex
- W2147726813
- Cited by
- 319
- References
- 99
- FWCI
- 13.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.