Microvascular Rheology and Hemodynamics
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
The goal of elucidating the biophysical and physiological basis of pressure–flow relations in the microcirculation has been a recurring theme since the first observations of capillary blood flow in living tissues. At the birth of the Microcirculatory Society, seminal observations on the heterogeneous distribution of blood cells in the microvasculature and the rheological properties of blood in small bore tubes raised many questions on the viscous properties of blood flow in the microcirculation that captured the attention of the Society's membership. It is now recognized that blood viscosity in small bore tubes may fall dramatically as shear rates are increased, and increase dramatically with elevations in hematocrit. These relationships are strongly affected by blood cell deformability and concentration, red cell aggregation, and white cell interactions with the red cells and endothelium. Increasing strength of red cell aggregation may result in sequestration of clumps of red cells with either reductions or increases in microvascular hematocrit dependent upon network topography. During red cell aggregation, resistance to flow may thus decrease with hematocrit reduction or increase due to redistribution of red cells. Blood cell adhesion to the microvessel wall may initiate flow reductions, as, for example, in the case of red cell adhesion to the endothelium in sickle cell disease, or leukocyte adhesion in inflammation. The endothelial glycocalyx has been shown to result from a balance of the biosynthesis of new glycans, and the enzymatic or shear‐dependent alterations in its composition. Flow‐dependent reductions in the endothelial surface layer may thus affect the resistance to flow and/or the adhesion of red cells and/or leukocytes to the endothelium. Thus, future studies aimed at the molecular rheology of the endothelial surface layer may provide new insights into determinants of the resistance to flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE VISCOSITY OF THE BLOOD IN NARROW CAPILLARY TUBES
Fåhræus, R., & Lindqvist, T. (1931) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1931.96.3.562 · Cited by 1,268
The History of Poiseuille's Law
Sutera, S. P., & Skalak, R. (1993) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.25.010193.000245 · Cited by 957 · cited 2×
“Although best known for his experimental studies of the flow of fluids through tubes, Poiseuille’s earlier observations on the separation of cells and plasma in arterioles and venules led to the discovery of “plasma skimming’’ and the need for a greater understanding of the mechanics of blood flow (67).”
BackgroundTHE SUSPENSION STABILITY OF THE BLOOD
Fåhraeus, R. (1929) · Physiological Reviews · doi:10.1152/physrev.1929.9.2.241 · Cited by 938
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (2000) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s004240000307 · Cited by 898
Resistance to blood flow in microvessels in vivo.
Pries, A. R., Secomb, T. W., Gessner, T., Sperandio, M. B., Gross, J. F., & Gaehtgens, P. (1994) · Circulation Research · doi:10.1161/01.res.75.5.904 · Cited by 616
Vink, H., & Duling, B. R. (1996) · Circulation Research · doi:10.1161/01.res.79.3.581 · Cited by 615
Pulsatile pressures in the microcirculation of frog's mesentery
Wiederhielm, C. A., Woodbury, J. W., Kirk, S., & Rushmer, R. F. (1964) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1964.207.1.173 · Cited by 439
The distribution of blood rheological parameters in the microvasculature of cat mesentery.
Lipowsky, H. H., Kovalcheck, S., & Zweifach, B. W. (1978) · Circulation Research · doi:10.1161/01.res.43.5.738 · Cited by 408
Self-citationIn vivo measurements of “apparent viscosity” and microvessel hematocrit in the mesentery of the cat
Lipowsky, H. H., Usami, S., & Chien, S. (1980) · Microvascular Research · doi:10.1016/0026-2862(80)90050-3 · Cited by 398
Self-citationInflammation- and ischemia-induced shedding of venular glycocalyx
Mulivor, A. W., & Lipowsky, H. H. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00832.2003 · Cited by 382
Self-citation
Cited by
The endothelial glycocalyx: composition, functions, and visualization
Reitsma, S., Slaaf, D. W., Vink, H., van Zandvoort, M. A. M. J., & oude Egbrink, M. G. A. (2007) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0212-8 · Cited by 1,980
Vascular Endothelial Cell Biology: An Update
Krüger-Genge, A., Blocki, A., Franke, R.-P., & Jung, F. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20184411 · Cited by 1,163
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
The endothelial glycocalyx: a review of the vascular barrier
Alphonsus, C. S., & Rodseth, R. N. (2014) · Anaesthesia · doi:10.1111/anae.12661 · Cited by 460
Flow Effects on Coagulation and Thrombosis
Hathcock, J. J. (2006) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000229658.76797.30 · Cited by 387
Numerical Simulation of Flowing Blood Cells
Freund, J. B. (2014) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010313-141349 · Cited by 323
The endothelial glycocalyx: a potential barrier between health and vascular disease
Nieuwdorp, M., Meuwese, M. C., Vink, H., Hoekstra, J. B., Kastelein, J. J., & Stroes, E. S. (2005) · Current Opinion in Lipidology · doi:10.1097/01.mol.0000181325.08926.9c · Cited by 309
Tsai, M., Kita, A., Leach, J., Rounsevell, R., Huang, J. N., Moake, J., Ware, R. E., Fletcher, D. A., & Lam, W. A. (2012) · Journal of Clinical Investigation · doi:10.1172/jci58753 · Cited by 297
Analyzing cell mechanics in hematologic diseases with microfluidic biophysical flow cytometry
Rosenbluth, M. J., Lam, W. A., & Fletcher, D. A. (2008) · Lab on a Chip · doi:10.1039/b802931h · Cited by 297
Red cells’ dynamic morphologies govern blood shear thinning under microcirculatory flow conditions
Lanotte, L., Mauer, J., Mendez, S., Fedosov, D. A., Fromental, J.-M., Claveria, V., Nicoud, F., Gompper, G., & Abkarian, M. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1608074113 · Cited by 268
Lymph Flow, Shear Stress, and Lymphocyte Velocity in Rat Mesenteric Prenodal Lymphatics
DIXON, J. B., GREINER, S. T., GASHEV, A. A., COTE, G. L., MOORE, J. E., & ZAWIEJA, D. C. (2006) · Microcirculation · doi:10.1080/10739680600893909 · Cited by 267
Chemotherapy exposure increases leukemia cell stiffness
Lam, W. A., Rosenbluth, M. J., & Fletcher, D. A. (2007) · Blood · doi:10.1182/blood-2006-08-043570 · Cited by 255
Koutsiaris, A. G., Tachmitzi, S. V., Batis, N., Kotoula, M. G., Karabatsas, C. H., Tsironi, E., & Chatzoulis, D. Z. (2007) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2007044005006008 · Cited by 244
“6, a steep decrease (approximately 17 times, from the best fit line) of WSS values from capillaries to post capillary venules is seen, that has also been observed in other animal tissues [21].”
InfluentialUse of inotropes and vasopressor agents in critically ill patients
Bangash, M. N., Kong, M., & Pearse, R. M. (2012) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2011.01588.x · Cited by 197
“Importantly, hyperglycaemia may be associated with denudation of the endothelial glycocalyx and deleterious effects on the microcirculation (Lipowsky, 2005).”
BackgroundOn the near-wall accumulation of injectable particles in the microcirculation: smaller is not better
Lee, T.-R., Choi, M., Kopacz, A. M., Yun, S.-H., Liu, W. K., & Decuzzi, P. (2013) · Scientific Reports · doi:10.1038/srep02079 · Cited by 190
Nanomechanics of the Endothelial Glycocalyx in Experimental Sepsis
Wiesinger, A., Peters, W., Chappell, D., Kentrup, D., Reuter, S., Pavenstädt, H., Oberleithner, H., & Kümpers, P. (2013) · PLoS ONE · doi:10.1371/journal.pone.0080905 · Cited by 170
“It has been shown that loss of the eGC constituents - and as a consequence softening of the eGC - can lead to changes in microvascular rheology and haemodynamics [21,22].”
BackgroundNguyen, J., Nishimura, N., Fetcho, R. N., Iadecola, C., & Schaffer, C. B. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.95 · Cited by 95
“The 5% to 10% increase in intravascular pressure we calculate compares well with the pressure difference measured between capillary beds and the first draining venules in cat mesentery (Lipowsky, 2005).”
Rosidi, N. L., Zhou, J., Pattanaik, S., Wang, P., Jin, W., Brophy, M., Olbricht, W. L., Nishimura, N., & Schaffer, C. B. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026612 · Cited by 87
Multi-Omics Endotypes in ICU Sepsis-Induced Immunosuppression
Garduno, A., Cusack, R., Leone, M., Einav, S., & Martin-Loeches, I. (2023) · Microorganisms · doi:10.3390/microorganisms11051119 · Cited by 39
“As inflammation continues, platelets and components of the coagulation cascade alter microcirculatory flow dynamics causing stagnation and activated cells changing the blood rheology [38,55].”
Background
Metadata
- Authors
- LIPOWSKY, H. H.
- Venue
- Microcirculation
- Publisher
- Wiley
- Published
- 2005-01-02
- Volume
- 12
- Issue
- 1
- Pages
- 5-15
- ISSN
- 1073-9688 (ISSN-L)
- 1549-8719
- OpenAlex
- W2007243735
- Cited by
- 414
- References
- 50
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.