Experimental determination of the regional deposition of aerosol particles in the human respiratory tract
The DOI matches its Crossref record.
Abstract
The experimental techniques and the results of inhalation studies with radioaerosols on normal non-smokers for mouth-breathing are described and discussed. Monodisperse iron oxide particles tagged with 198Au are produced with a spinning top generator in the aerodynamic size range between 1 to 10 micrometers. An aerosol inhalation apparatus enables the subjects to breathe under standardized conditions with respect to tidal volume and breathing frequency. The calculation of total deposition is based upon measurements of the number of in- and exhaled particles per breath by means of photometric methods and pneumotachography. The retention of the radioactive particles present in the body after aerosol administration is measured with a body counter designed and constructed for these experiments. Retention measurements as functions of time after inhalation are carried out in extrathoracic-, chest- and stomach-position. The body counter consists of four shielded NaF(TI)-detectors. The geometrical arrangement, the collimation and the shielding of the four detectors have been optimized by computer calculations in such a way that the response of the counter is independent of the distribution of activity within the chest. Another characteristic feature of the body counter is its low sensitivity to neighboring organs and to neighboring regions within the respiratory tract. For the evaluation of extrathoracic deposition, the activity measured in the stomach immediately after inhalation is added to extrathoracic activity. The elimination of material from the chest (intrathoracic airways) is found to be much slower for the material deposited in the alveolar region (non-ciliated air spaces) than for the amount deposited in the tracheobronchial tree (ciliated airways). This allows the intrathoracic deposition to be divided into tracheobronchial and alveolar deposition by means of the different slopes of the normalized chest retention function. Different normalized chest retention functions are presented and analysed with respect to their different elimination rates belonging to the tracheobronchial and alveolar region. Total, tracheobronchial, alveolar and extrathoracic deposition data are reported in the aerodynamic diameter range between 1 and 10 micrometers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deposition of particles in the human respiratory tract in the size range 0.005–15 μm
Heyder, J., Gebhart, J., Rudolf, G., Schiller, C. F., & Stahlhofen, W. (1986) · Journal of Aerosol Science · doi:10.1016/0021-8502(86)90035-2 · Cited by 1,026
Self-citationDeposition, retention, and clearance of inhaled particles.
Lippmann, M., Yeates, D. B., & Albert, R. E. (1980) · Occupational and Environmental Medicine · doi:10.1136/oem.37.4.337 · Cited by 557
Modelling inhaled particle deposition in the human lung—A review
Hofmann, W. (2011) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2011.05.007 · Cited by 492
Transport and Deposition of Particles in Turbulent and Laminar Flow
Guha, A. (2008) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.40.111406.102220 · Cited by 481
Thoracic and Respirable Particle Definitions for Human Health Risk Assessment
Brown, J. S., Gordon, T., Price, O., & Asgharian, B. (2013) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-10-12 · Cited by 474
“, light exercise [5-7].”
Intercomparison of experimental regional aerosol deposition data
STAHLHOFEN, W., RUDOLF, G., & JAMES, A. C. (1989) · Journal of Aerosol Medicine · doi:10.1089/jam.1989.2.285 · Cited by 423
Self-citationWorkman, A. D., Welling, D. B., Carter, B. S., Curry, W. T., Holbrook, E. H., Gray, S. T., Scangas, G. A., & Bleier, B. S. (2020) · International Forum of Allergy & Rhinology · doi:10.1002/alr.22577 · Cited by 328
Comparison of micro- and nano-size particle depositions in a human upper airway model
Zhang, Z., Kleinstreuer, C., Donohue, J. F., & Kim, C. S. (2005) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2004.08.006 · Cited by 325
The science of nebulised drug delivery
O'Callaghan, C., & Barry, P. W. (1997) · Thorax · doi:10.1136/thx.52.2008.s31 · Cited by 293
Targeted Drug-Aerosol Delivery in the Human Respiratory System
Kleinstreuer, C., Zhang, Z., & Donohue, J. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160544 · Cited by 267
Aerosol deposition considerations in inhalation therapy
Newman, S. P. (1985) · Chest · doi:10.1378/chest.88.2.152s · Cited by 264
Deposition and clearance of inhaled particles.
Stuart, B. O. (1984) · Environmental Health Perspectives · doi:10.1289/ehp.8455369 · Cited by 255
Aerosol Deposition in the Extrathoracic Region
Cheng, Y. S. (2003) · Aerosol Science and Technology · doi:10.1080/02786820300906 · Cited by 245
“Oral deposition efficiency as a function of impaction parameter for an adult human subject (Stahlhofen et al. 1980).”
BackgroundMechanisms of Pharmaceutical Aerosol Deposition in the Respiratory Tract
Cheng, Y. S. (2014) · AAPS PharmSciTech · doi:10.1208/s12249-014-0092-0 · Cited by 244
Regional deposition of inhaled particles in human lungs: comparison between men and women
Kim, C. S., & Hu, S. C. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.6.1834 · Cited by 237
Inhalable nanoparticulate powders for respiratory delivery
Muralidharan, P., Malapit, M., Mallory, E., Hayes, D., & Mansour, H. M. (2015) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2015.01.007 · Cited by 232
In vitro intersubject and intrasubject deposition measurements in realistic mouth–throat geometries
Grgic, B., Finlay, W. H., Burnell, P. K. P., & Heenan, A. F. (2004) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2004.03.003 · Cited by 221
Airway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers
Pauwels, R., Newman, S., & Borgstrom, L. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10092127 · Cited by 198
“Before inhalation, the drug must be aerosolized, as only very fine particles (below approximately 5 μm diameter) will reach the lower airways, and larger particles will to a great extent deposit in the oropharyngeal region before being swallowed [3].”
BackgroundZhang, Y., Huang, W., Cai, T., Fang, D., Wang, Y., Song, J., Hu, M., & Zhang, Y. (2016) · Atmospheric Research · doi:10.1016/j.atmosres.2016.02.003 · Cited by 173
Variability of fine particle deposition in healthy adults: effect of age and gender.
Bennett, W. D., Zeman, K. L., & Kim, C. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.5.8630615 · Cited by 166
Interpretation of "24 Hour Lung Retention" in Studies of Mucociliary Clearance
SMALDONE, G. C., PERRY, R. J., BENNETT, W. D., MESSINA, M. S., ZWANG, J., & ILOWITE, J. (1988) · Journal of Aerosol Medicine · doi:10.1089/jam.1988.1.11 · Cited by 105
Mathematical analysis of particle deposition in human lungs: An improved single path transport model
Choi, J.-I., & Kim, C. S. (2007) · Inhalation Toxicology · doi:10.1080/08958370701513014 · Cited by 101
“shown in the figure are the means of experimental data several studies including the former two as proposed by Stahlhofen et al. (1989). It is noted that the present model predictions agree very well with experimental data, indicating that the present model is sufficiently accurate to use for predicting TB deposition.”
BackgroundResult
Metadata
- Authors
- Stahlhofen, W., Gebhart, J., & Heyder, J.
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1980-06
- Volume
- 41
- Issue
- 6
- Pages
- 385-398a
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2006963172
- Cited by
- 444
- References
- 0
- FWCI
- 16.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.