Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Certain respiratory tract infections are transmitted through air. Coughing and sneezing by an infected person can emit pathogen-containing particles with diameters less than 10 microm that can reach the alveolar region. Based on our analysis of the sparse literature on respiratory aerosols, we estimated that emitted particles quickly decrease in diameter due to water loss to one-half the initial values, and that in one cough the volume in particles with initial diameters less than 20 microm is 60 x 10(-8) mL. The pathogen emission rate from a source case depends on the frequency of expiratory events, the respirable particle volume, and the pathogen concentration in respiratory fluid. Viable airborne pathogens are removed by exhaust ventilation, particle settling, die-off, and air disinfection methods; each removal mechanism can be assigned a first-order rate constant. The pathogen concentration in well-mixed room air depends on the emission rate, the size distribution of respirable particles carrying pathogens, and the removal rate constants. The particle settling rate and the alveolar deposition fraction depend on particle size. Given these inputs plus a susceptible person's breathing rate and exposure duration to room air, an expected alveolar dosemicrois estimated. If the infectious dose is one organism, as appears to be true for tuberculosis, infection risk is estimated by the expression: R = 1-exp(-micro). Using published tuberculosis data concerning cough frequency, bacilli concentration in respiratory fluid, and die-off rate, we illustrate the model via a plausible scenario for a person visiting the room of a pulmonary tuberculosis case. We suggest that patients termed "superspreaders" or "dangerous disseminators" are those infrequently encountered persons with high values of cough and/or sneeze frequency, elevated pathogen concentration in respiratory fluid, and/or increased respirable aerosol volume per expiratory event such that their pathogen emission rate is much higher than average.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Previous authors have noted that the viral load of human-emitted infectious aerosols may depend on sputum volume [31,42].”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atmospheric Chemistry and Physics: From Air Pollution to Climate Change
Seinfeld, J. H., Pandis, S. N., & Noone, K. (1998) · Physics Today · doi:10.1063/1.882420 · Cited by 8,731 · cited 3×
“However, if the infec-tious dose is 10 organisms, infection risk is only 1.1 × 10 −7 according to the above expression based on Equation 14 .”
BackgroundInfluentialGuideline for Isolation Precautions in Hospitals
Garner, J. S., & the Hospital Infection Control Practices Advisory Committee (1996) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700006123 · Cited by 994
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850 · cited 1×
“These studies were published by Duguid (15) in 1946, Louden and Roberts ( eq 4) in 1967, and Papineni and Rosenthal (16) in 1997.”
BackgroundThe size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 10×
“The Papineni and Rosenthal findings substantially differ from the data reported by Duguid and by Louden and Roberts (hereafter denoted L&R).”
BackgroundInfluential(2001) · Cited by 666
WELLS, W. F. (1934) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a118097 · Cited by 602 · cited 1×
“W.F. Wells (4) argued that droplets derived from respiratory fluid with d a < 100 µm rapidly evaporate to become droplet nuclei before they can be removed from air by gravitational settling.”
BackgroundDilution of Respiratory Solutes in Exhaled Condensates
EFFROS, R. M., HOAGLAND, K. W., BOSBOUS, M., CASTILLO, D., FOSS, B., DUNNING, M., GARE, M., LIN, W., & SUN, F. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2101018 · Cited by 386 · cited 2×
“The regression equation did not account for water loss from the larger particles prior to deposition onto bond paper,(13) and there was no adjustment for evaporative water loss from the smaller particles collected on the Millipore filter.”
BackgroundRiley, R. L., MILLS, C. C., O'Grady, F., SULTAN, L. U., Wittstadt, F. B., & Shivpuri, D. (1962) · PubMed · doi:10.1164/arrd.1962.85.4.511 · Cited by 313
Airborne Contagion and Air Hygiene
Phair, J. J. (1955) · American Journal of Public Health and the Nations Health · doi:10.2105/ajph.45.11.1495-c · Cited by 257
Murray, D. M., & Burmaster, D. E. (1995) · Risk Analysis · doi:10.1111/j.1539-6924.1995.tb00338.x · Cited by 250 · cited 1×
“5 ach is a typical residential air exchange rate.(31) Airborne M.”
Background
Research works printed but not linked: 6
- 4. Wells, W.F.: Onair-borne infection. Study II. Droplets and droplet nuclei. Am. J. Hyg. 20 :611-618 (1934).
- 5. Hinds, W.C.: Aerosol Technology . New York: John Wiley & Sons, Inc., 57-58:211-221 (1982).
- 7. Sonkin, L.S.: The role of particle size in experimental airborne infection. Am. J. Hyg. 53 :337-354 (1951).
- 21. Jennison, M.W.: Atomizing of mouth and nose secretions into the air as revealed by high-speed photography. In Aerobiology (Pub. No. 17). Washington, D.C.: American Association for the Advancement of Science, 1942. pp. 106-128.
- 33. Office of Research and Development: Exposure Factors Handbook (Draft). Washington, D.C.: U.S. Environmental Protection Agency, 1996. pp. 5-22.
- 36. Riley, R.L., C.C. Mills, F. O'Grady, L.U. Sultan, F. Wittstadt, and D.N. Shivpuri: Infectiousness of air from a tuberculosis ward. Am. Rev. Resp. Dis. 85 :511-525 (1962).
Cited by
Items 201–300 of 942
Liu, H., Liu, Z., Wang, Y., Hu, C., & Rong, R. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109690 · Cited by 62
“Considering the evaporation of droplets, glycerol was added to the artificial saliva to represent the non-volatile substances in the droplets [43,44].”
Chen, C., Zhao, B., Yang, X., & Li, Y. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0486 · Cited by 62
Fuehner, T., Dierich, M. G., Duesberg, C., DeWall, C., Welte, T., Haverich, A., Warnecke, G., Simon, A. R., & Gottlieb, J. (2011) · Antiviral Therapy · doi:10.3851/imp1811 · Cited by 62
“Additional goals in PV management are prevention of infection and the future development of effective vaccines [30].”
BackgroundWurie, F. B., Lawn, S. D., Booth, H., Sonnenberg, P., & Hayward, A. C. (2016) · Thorax · doi:10.1136/thoraxjnl-2015-207295 · Cited by 52
“Nicas et al21 defined super-spreaders, ‘as those infrequently encountered persons with high cough and/or sneeze frequency, elevated pathogen concentration in respiratory fluid, and/or increased respirable aerosol volume per expiratory event such that their pathogen emission rate is much higher than average’.”
The transport of gaseous pollutants due to stack and wind effect in high-rise residential buildings
Mao, J., Yang, W., & Gao, N. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.10.012 · Cited by 62
Zuraimi, M. S., Nilsson, G., & Magee, R. J. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.06.008 · Cited by 62
COVID-19: An Aerosol’s Point of View from Expiration to Transmission to Viral-mechanism
Hsiao, T.-C., Chuang, H., Griffith, S. M., Chen, S., & Young, L. (2020) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2020.04.0154 · Cited by 61
“Once expelled, respiratory droplets rapidly evaporate (< 1 s) to an equilibrium size that is dependent on ambient relative humidity and original droplet size before falling away (Nicas et al. , 2005; Xie et al. , 2007; Morawska et al. , 2009).”
Chen, C., Liu, W., Lin, C., & Chen, Q. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1079587 · Cited by 61
“Exhalation activities by an infected person, such as breathing, coughing, and sneezing, can generate particles carrying infectious viruses (Nicas et al. 2005).”
BackgroundRole of viral bioaerosols in nosocomial infections and measures for prevention and control
Bing-Yuan, Zhang, Y., Leung, N., Cowling, B. J., & Yang, Z. (2017) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2017.11.011 · Cited by 65
“Furthermore, respiratory droplets < 20 µm at expulsion could transform into droplet nuclei by evaporation and shrinks to a little less than half of the initial diameter (Nicas, Nazaroff, & Hubbard, 2005; Tellier, 2009; Xie, Li, Chwang, Ho, & Seto, 2007) .”
BackgroundMu, D., Gao, N., & Zhu, T. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.051 · Cited by 61
“Such long-distance routes of transmission are called airborne transmission, which is reported to be one of the major respiratory syndrome transmission routes by numerous engineering and epidemiological studies [2] [3] [4] [5] .”
BackgroundA dynamical overview of droplets in the transmission of respiratory infectious diseases
Zhou, M., & Zou, J. T. (2021) · Physics of Fluids · doi:10.1063/5.0039487 · Cited by 62
Park, S., Mistrick, R. G., & Rim, D. (2022) · Sustainable Cities and Society · doi:10.1016/j.scs.2022.104048 · Cited by 60
A hybrid model for investigating transient particle transport in enclosed environments
Chen, C., Liu, W., Li, F., Lin, C., Liu, J., Pei, J., & Chen, Q. (2013) · Building and Environment · doi:10.1016/j.buildenv.2012.12.020 · Cited by 60
“Breathing, coughing, talking, and sneezing by an infected person can generate pathogen-carrying particles and can cause the transmission of infectious diseases [2,3].”
Viral kinetics and exhaled droplet size affect indoor transmission dynamics of influenza infection
CHEN, S. C., Chio, C., Jou, L., & Liao, C. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00603.x · Cited by 60
“A droplet nucleus is the airborne residue of a potentially infectious (microorganism bearing) aerosol from which most of the liquid has evaporated (Nicas et al., 2005; Wells, 1934).”
BackgroundMethodAi, Z., Huang, T., & Melikov, A. K. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106328 · Cited by 59
Transmission and prevention of SARS-CoV-2
Wang, Z., Fu, Y., Guo, Z., Li, J., Li, J., Cheng, H., Lu, B., & Sun, Q. (2020) · Biochemical Society Transactions · doi:10.1042/bst20200693 · Cited by 58
Wu, Y., Tung, T. C. W., & Niu, J. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.01.013 · Cited by 58
Open questions on the physical properties of aerosols
Bzdek, B. R., Reid, J. P., & Cotterell, M. I. (2020) · Communications Chemistry · doi:10.1038/s42004-020-00342-9 · Cited by 58
Susceptibility of an Airborne Common Cold Virus to Relative Humidity
Niazi, S., Groth, R., Cravigan, L. T., He, C., Tang, J. W.-T., Spann, K. M., & Johnson, G. R. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c06197 · Cited by 57
Rothamer, D. A., Sanders, S. T., Reindl, D. T., & Bertram, T. H. (2021) · Science and Technology for the Built Environment · doi:10.1080/23744731.2021.1944665 · Cited by 58
Bioaerosol sampling for the detection of aerosolized influenza virus
Blachère, F. M., Lindsley, W. G., Slaven, J. E., Green, B. J., Anderson, S. E., Chen, B. T., & Beezhold, D. H. (2007) · Influenza and Other Respiratory Viruses · doi:10.1111/j.1750-2659.2007.00020.x · Cited by 57
“3, 4 Given the epidemic potential and public health concern of newly emerging diseases such as avian influenza (H5N1) and severe acute respiratory syndrome (SARS), 5, 6 it is important to develop methods to study aerosolized viral particles.”
BackgroundAirborne Infection Isolation Rooms – A Review of Experimental Studies
Hyttinen, M., Rautio, A., Pasanen, P. O., Reponen, T. A., Earnest, G. S., Streifel, A. J., & Kalliokoski, P. (2011) · Indoor and Built Environment · doi:10.1177/1420326x11409452 · Cited by 56
Niazi, S., Short, K. R., Groth, R., Cravigan, L. T., Spann, K. M., Ristovski, Z., & Johnson, G. R. (2021) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.1c00253 · Cited by 56
Cummins, C., Ajayi, O., Mehendale, F. V., Gabl, R., & Viola, I. M. (2020) · Physics of Fluids · doi:10.1063/5.0021427 · Cited by 56
Modelling airborne transmission of SARS-CoV-2 using CARA: risk assessment for enclosed spaces
Henriques, A., Mounet, N., Aleixo, L., Elson, P., Devine, J., Azzopardi, G., Andreini, M., Rognlien, M., Tarocco, N., & Tang, J. W.-T. (2022) · Interface Focus · doi:10.1098/rsfs.2021.0076 · Cited by 56
“In this paper, a physical model is proposed, adapted from previous implementations of other infectious models such as the Wells–Riley approach [5,6], to simulate the concentration of infectious viruses in an enclosed indoor volume, wherein infectious occupants with COVID-19 are shedding SARSCoV-2 viruses.”
MethodA Novel Nonhuman Primate Model for Influenza Transmission
Moncla, L. H., Ross, T. M., Dinis, J. M., Weinfurter, J. T., Mortimer, T. D., SCHULTZ‐DARKEN, N. J., Brunner, K. G., Capuano, S., Boettcher, C., Post, J., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0078750 · Cited by 55
“Sneezing generates a large number of particles that can vary substantially in size [19]; upon expulsion into the air, small particles can rapidly evaporate and shrink, allowing them to float in air currents without settling for long periods of time [18].”
BackgroundTransmission of influenza A in human beings
Tellier, R. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70269-4 · Cited by 55
A Comprehensive Breath Plume Model for Disease Transmission via Expiratory Aerosols
Halloran, S. K., Wexler, A. S., & Ristenpart, W. D. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037088 · Cited by 40
“At relative humidities greater than the deliquescence relative humidity, aerosols will begin to grow through the acquisition of water from their surroundings [32].”
BackgroundMethodSusceptibility of monkeypox virus aerosol suspensions in a rotating chamber
Verreault, D., Killeen, S. Z., Redmann, R. K., & Roy, C. J. (2012) · Journal of Virological Methods · doi:10.1016/j.jviromet.2012.10.009 · Cited by 54
“The induction of the infectious process through aerosol exposure begins with the transport of the viral-laden particles to the susceptible host and depends on the effects of physiochemical factors on the integrity of the virus (Nicas et al., 2005).”
Model Analysis of Fomite Mediated Influenza Transmission
Zhao, J., Eisenberg, J., Spicknall, I. H., Li, S., & Koopman, J. S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0051984 · Cited by 54
“99%) of cough excretions being so large that they settle from the air rapidly [4,14].”
BackgroundAganović, A., Cao, G., Kurnitski, J., & Wargocki, P. L. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109924 · Cited by 53
“where Dmax and Dmin denote the bin’s lower and upper diameter values, according to Nicas [40].”
Structural stability of SARS-CoV-2 virus like particles degrades with temperature
Sharma, A. R., Preece, B., Swann, H., Fan, X., McKenney, R. J., Ori-McKenney, K. M., Saffarian, S., & Vershinin, M. D. (2020) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2020.11.080 · Cited by 53
“The bioaerosol droplets tend to dry out quickly due to high surface area and small volume [11,12].”
Schade, W., Reimer, V., Seipenbusch, M., & Willer, U. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18063037 · Cited by 52
Revisiting physical distancing threshold in indoor environment using infection-risk-based modeling
Liu, F., Luo, Z., Li, Y., Zheng, X., Zhang, C., & Qian, H. (2021) · Environment International · doi:10.1016/j.envint.2021.106542 · Cited by 52
“Studies on airborne transmission indicated that infections via aerosols were most likely to originate in the lower respiratory tract, specifically the alveoli (Nicas et al., 2005).”
BackgroundXu, R., Wu, F., Li, X., Yu, C., Li, H., Wu, R., & Wu, Y. (2022) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/j.jweia.2022.105240 · Cited by 52
The Infectious Dose of Francisella Tularensis (Tularemia)
Jones, R. M., Nicas, M., Hubbard, A., Sylvester, M. D., & Reingold, A. L. (2005) · Applied Biosafety · doi:10.1177/153567600501000405 · Cited by 52
Self-citationEmmerich, S. J., Heinzerling, D., Choi, J., & Persily, A. K. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.11.013 · Cited by 50
Can extraoral suction units minimize droplet spatter during a simulated dental procedure?
Chavis, S. E., Hines, S. E., Dyalram, D., Wilken, N. C., & Dalby, R. N. (2021) · The Journal of the American Dental Association · doi:10.1016/j.adaj.2020.10.010 · Cited by 50
Aganović, A., Bi, Y., Cao, G., Kurnitski, J., & Wargocki, P. L. (2022) · Scientific Reports · doi:10.1038/s41598-022-15703-8 · Cited by 50
Assessing Infection Control Measures for Pandemic Influenza
Wein, L. M., & Atkinson, M. P. (2009) · Risk Analysis · doi:10.1111/j.1539-6924.2009.01232.x · Cited by 51
“, hands, tissues) due to the infected’s efforts to protect the sneeze or cough,(16) instantaneous deposition for particles >20 μm in diameter,(17) decay in the air, settling from the air to the surfaces, and air”
BackgroundMousavi, E. S., & Grosskopf, K. (2015) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mev048 · Cited by 50
“…or airborne ‘droplet nuclei’ (Tang et al., 2006) and was again consistent with other studies (Papineni and Rosenthal, 1997; Fennelly et al., 2004; Nicas et al., 2005; Xie et al., 2007; Yang et al., 2007) which suggest that human respiratory activity (e.g. coughing, sneezing, etc.) generates as…”
Properties of materials considered for improvised masks
Rogak, S. N., Sipkens, T. A., Guan, M., Nikookar, H., Figueroa, D. V., & Wang, J. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2020.1855321 · Cited by 50
“The majority of the mass is contained in the larger droplets, which typically settle on the order of several meters of the source but could be carried further by winds or the momentum from a powerful sneeze (Bahl et al. 2020; Nicas, Nazaroff, and Hubbard 2005; Bourouiba 2020).”
BackgroundMethodInfluentialTurbulence role in the fate of virus-containing droplets in violent expiratory events
Rosti, M. E., Cavaiola, M., Olivieri, S., Seminara, A., & Mazzino, A. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.013091 · Cited by 49
Droplets and aerosols: An artificial dichotomy in respiratory virus transmission
Drossinos, Y., Weber, T. P., & Stilianakis, N. I. (2021) · Health Science Reports · doi:10.1002/hsr2.275 · Cited by 49
“Respiratory droplets are aqueous droplets containing nonvolatile species like organic and inorganic salts, surfactants and proteins, and microbes.(10) The equilibrium droplet size”
BackgroundWhat is suitable social distancing for people wearing face masks during the COVID‐19 pandemic?
Deng, Z., & Chen, Q. (2021) · Indoor Air · doi:10.1111/ina.12935 · Cited by 49
Guo, W., Fu, Y., Jia, R., Guo, Z., Su, C., Li, J., Zhao, X., Jin, Y., Li, P., Fan, J., et al. (2022) · Environment International · doi:10.1016/j.envint.2022.107153 · Cited by 49
Elmaghraby, H. A., Chiang, Y. W., & Aliabadi, A. A. (2017) · Science and Technology for the Built Environment · doi:10.1080/23744731.2017.1387463 · Cited by 48
“Many studies have investigated the characteristics of particles originated from expiratory human activities and their spread in indoor spaces in the last century (Fairchild and Stampfer 1987; Loudon and Roberts 1967; Nicas et al. 2005; Papineni and Rosenthal 1997; Zhao et al. 2005).”
BackgroundSafer Singing During the SARS-CoV-2 Pandemic: What We Know and What We Don't
Naunheim, M. R., Bock, J. M., Doucette, P., Hoch, M., Howell, I. B., Johns, M. M. E., Johnson, A. M., Krishna, P. D., Meyer, D. I., Milstein, C. F., et al. (2020) · Journal of Voice · doi:10.1016/j.jvoice.2020.06.028 · Cited by 50
“Asadi et al(5) demonstrated that certain individuals are “speech superemitters” who exude significantly more aerosol particles than others, and this has been corroborated by previous literature.(29) The same group also demonstrated that louder phonation resulted in greater aerosol generation.”
ResultGao, N., He, Q., & Niu, J. (2012) · Building Simulation · doi:10.1007/s12273-012-0068-5 · Cited by 48
Experimental and numerical study on particle distribution in a two-zone chamber
Lai, A. C. K., Wang, K., & Chen, F. Z. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.11.030 · Cited by 48
“Indoor air quality and healthrisk exposure assessment usually treat indoor microenvironments as well-mixed micro-compartments where the concentrations of particles are determined by a simple material-balance principle (Nardell, 1998; Nicas et al., 2005).”
Aerosol transmission of SARS‐CoV‐2 by children and adults during the COVID‐19 pandemic
Moschovis, P. P., Yonker, L. M., Shah, J., Singh, D., Demokritou, P., & Kinane, T. B. (2021) · Pediatric Pulmonology · doi:10.1002/ppul.25330 · Cited by 48
“large particles emitted from the nose or mouth can evaporate very quickly, decreasing their size and transforming into aerosols (a “droplet nucleus”).(8) The characteristics of the indoor environment (i.”
BackgroundChallenges in simulating and modeling the airborne virus transmission: A state-of-the-art review
Pourfattah, F., Wang, L., Deng, W., Ma, Y., Hu, L., & Yang, B. (2021) · Physics of Fluids · doi:10.1063/5.0061469 · Cited by 48
Risk assessment for long- and short-range airborne transmission of SARS-CoV-2, indoors and outdoors
Poydenot, F., Abdourahamane, I., Caplain, E., Der, S., Haiech, J., Jallon, A., Khoutami, I., Loucif, A., Marinov, E., & Andreotti, B. (2022) · PNAS Nexus · doi:10.1093/pnasnexus/pgac223 · Cited by 48
Levels and particle size distribution of airborne SARS-CoV-2 at a healthcare facility in Kuwait
Stern, R. A., Al-Hemoud, A. M., Alahmad, B., & Koutrakis, P. (2021) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2021.146799 · Cited by 47
“In other respiratory diseases, pathogens on smaller particles require fewer microorganisms to cause an infection than those on larger particles (Thomas, 2013; Nicas et al., 2005; Tellier, 2006).”
Wang, Q., Gu, J., & An, T. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109224 · Cited by 47
“For instance, the major components of mucus include Na, Cl , K, lactate and glycoprotein [46], which would form a droplet nuclei with a diameter of about half of the original droplet size after evaporation [47].”
Relation Between Humidity and Size of Exhaled Particles
Holmgren, H., Bake, B., Olin, A., & Ljungström, E. (2011) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2011.0880 · Cited by 45
“Nicas et al. (8) estimates that expiratory particles quickly decrease to half their diameter, corresponding to an eightfold increase in solute concentration, due to water loss.”
InfluentialAirflow patterns due to door motion and pressurization in hospital isolation rooms
Mousavi, E. S., & Grosskopf, K. (2016) · Science and Technology for the Built Environment · doi:10.1080/23744731.2016.1155959 · Cited by 46
“Certain pathogens are transmitted through air by respiratory droplets that desiccate shortly after emission and form droplet nuclei (Nicas et al. 2005).”
BackgroundAerosol Transmission of Filoviruses
Mekibib, B., & Ariën, K. K. (2016) · Viruses · doi:10.3390/v8050148 · Cited by 45
Transmission of droplet aerosols in an elevator cabin: Effect of the ventilation mode
Li, X., & Feng, B. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110261 · Cited by 44
“The quantity of released droplets for one breath from the nose was set to 500, whereas that for one cough was 5000 [33,34].”
Tang, J. W.-T., Gao, C. X., Cowling, B. J., Koh, G. C., Chu, D. K. W., Heilbronn, C., Lloyd, B. K., Pantelic, J., Nicolle, A. D., Klettner, C. A., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0107338 · Cited by 45
“In the close contact exposure scenario, small droplets generated by an infectious patient can be directly inhaled and deposit in both the upper and the lower airway, whereas large droplets can be also be directly inhaled, but the majority of these will probably deposit in the upper airways only, or directly enter the…”
BackgroundModeling the Effectiveness of Respiratory Protective Devices in Reducing Influenza Outbreak
Yan, J., Guha, S., Hariharan, P., & Myers, M. R. (2018) · Risk Analysis · doi:10.1111/risa.13181 · Cited by 45
Approaches in CFD modeling of respiratory droplet dispersion – issues and challenges
Sedighi, A. A., Haghighat, F., Nasiri, F., Cao, S., & Ren, C. (2023) · Sustainable Cities and Society · doi:10.1016/j.scs.2023.104696 · Cited by 42
Fabregat, A., Gisbert, F., Vernet, A., Ferré, J. A., Mittal, K., Dutta, S., & Pallarès, J. (2021) · Physics of Fluids · doi:10.1063/5.0045416 · Cited by 42
Risbeck, M. J., Bazant, M. Z., Jiang, Z., Lee, Y. M., Drees, K. H., & Douglas, J. D. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111497 · Cited by 42
“For example, the particles naturally deposit onto surfaces (with a size-dependent rate [19,20]) as fomites, thus rendering them unlikely to transmit the disease [21].”
Brown, K. W., Minegishi, T., Allen, J. G., McCarthy, J. F., Spengler, J. D., & MacIntosh, D. L. (2014) · Journal of Asthma · doi:10.3109/02770903.2014.895011 · Cited by 42
“Particle size distributions for viruses were determined from those measured in sneezes and coughs in previous work [27].”
Kanaan, M., Ghaddar, N., Ghali, K., & Araj, G. F. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.01.029 · Cited by 41
Fisher, E. M., Richardson, A. W., Harpest, S. D., Hofacre, K. C., & Shaffer, R. E. (2011) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mer101 · Cited by 41
“To assess the risk posed by the reaerosolization of respiratory viruses such as influenza, various techniques based upon modeling data (Nicas et al., 2005; Nicas and Gang, 2006; To and Chao, 2010) or actual exposure assessment data can be used.”
MethodModeling the factors that influence exposure to SARS‐CoV‐2 on a subway train carriage
Miller, D. N., King, M., Nally, J., Drodge, J., Reeves, G. I., Bate, A. M., Cooper, H., Dalrymple, U., Hall, I., López‐García, M., et al. (2022) · Indoor Air · doi:10.1111/ina.12976 · Cited by 41
“To illustrate this, we plot the predicted close-range doses corresponding to the unmasked scenario in Figure 9 showing the effect of using Duguid 31 or Loudon & Roberts 32,33 vs the default BLO coughing model.”
InfluentialFan, X., Zhang, X., Weerasuriya, A. U., Hang, J., Zeng, L., Luo, Q., Li, C. Y., & Chen, Z. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109261 · Cited by 41
Jones, R. M., Masago, Y., Bartrand, T. A., Haas, C. N., Nicas, M., & Rose, J. B. (2008) · Risk Analysis · doi:10.1111/j.1539-6924.2008.01161.x · Cited by 41
“The volume of saliva in respirable cough particles, V s, is 6 × 10−8 mL.(23) Cough frequency in Mtb patients was measured using an audio recording system for 8 h periods at night: the median cough frequency was 23 coughs per 8 h.”
BackgroundMethodSelf-citationAppert, J., Raynor, P. C., de Abin, M. F., Chander, Y., Guarino, H., Goyal, S. M., Zuo, Z., Ge, S., & Kuehn, T. H. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2011.619224 · Cited by 41
“Tidal breathing, coughing, and sneezing generate particles in a large range of sizes, from droplets that settle quickly, to fine aerosols that are capable of remaining in the air for long periods of time (Duguid 1946; Nicas et al. 2005).”
BackgroundTransport and trajectory of cough-induced bimodal aerosol in an air-conditioned space
Zhang, B., Guo, G., Zhu, C., Ji, Z., & Lin, C.-H. (2020) · Indoor and Built Environment · doi:10.1177/1420326x20941166 · Cited by 40
“The three components were water, glycerine and sodium chloride with the mass ratio of 100:76:12.(42) For saliva droplets, only the water component is evaporative.”
BackgroundRisk assessment for airborne disease transmission by poly-pathogen aerosols
Nordsiek, F., Bodenschatz, E., & Bagheri, G. (2021) · PLoS ONE · doi:10.1371/journal.pone.0248004 · Cited by 40
“For example; Nicas, Nazaroff & Hubbard [6] included sink terms for pathogen inactivation, aerosol settling, and deposition as well as less than unitary efficiency of the respiratory tract absorbing infectious aerosols.”
BackgroundInfluentialDhawan, S., & Biswas, P. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.1c00235 · Cited by 40
Killingley, B., Greatorex, J. S., Cauchemez, S., Enstone, J. E., Curran, M. D., Read, R. C., Lim, W., Hayward, A. C., Nicholson, K. G., & Nguyen‐Van‐Tam, J. S. (2010) · Health Technology Assessment · doi:10.3310/hta14460-04 · Cited by 40
Bacteria emitted in ambient air during bronchoscopy—a risk to health care workers?
Marchand, G., Duchaine, C., Lavoie, J., Veillette, M., & Cloutier, Y. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.04.241 · Cited by 39
Potential for occupational exposures to pathogens during bronchoscopy procedures
Zietsman, M., Phan, L. T., & Jones, R. M. (2019) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2019.1649414 · Cited by 39
“Cough generates polydisperse aerosols,([8]) many of which are larger than can be captured by the instruments used in this study.”
BackgroundSamaranayake, L. P., Fakhruddin, K. S., Ngo, H. C., Chang, J. W. W., & Panduwawala, C. (2020) · Acta Odontologica Scandinavica · doi:10.1080/00016357.2020.1810769 · Cited by 39
Is there an airborne component to the transmission of COVID-19? : a quantitative analysis studyPreprint
Beggs, C. B. (2020) · medRxiv · doi:10.1101/2020.05.22.20109991 · Cited by 40
“This was done using the methodology described in Nicas et al [21], where the volume of the average droplet, vi, in each class or ‘bin’ was determined using:”
BackgroundMethodInfluentialSpatial dynamics of airborne infectious diseases
Robinson, M., Stilianakis, N. I., & Drossinos, Y. (2011) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2011.12.015 · Cited by 38
“Generations rates per cough are taken as kd1 ¼ 160 day 1 (Nicas et al., 2005) and kd2 ¼ 240 day 1 (Morawska et al., 2009), the latter based on a cough volume of 400 cm3.”
BackgroundMethodInfluentialA human time dose response model for Q fever
Heppell, C. W., Egan, J. R., & Hall, I. (2017) · Epidemics · doi:10.1016/j.epidem.2017.06.001 · Cited by 38
Spread of SARS-CoV-2 in hospital areas
Grimalt, J. O., Vílchez, H., Fraile-Ribot, P. A., Marco, E., Campins, A. A., Orfila, J., van Drooge, B. L., & Fanjul, F. J. (2021) · Environmental Research · doi:10.1016/j.envres.2021.112074 · Cited by 38
“Infections in a host can even be caused by a single virus (Nicas et al., 2010), so inhalation by susceptible individuals can involve contagion and further spread of the disease (Asadi et al.”
Lednicky, J. A., Fennelly, K. P., Tribby, M., Wu, C., Heil, G. L., Radonovich, L. J., & Loeb, J. C. (2014) · Virus Adaptation and Treatment · doi:10.2147/vaat.s74789 · Cited by 38
Lemos, M. P., McKinney, J. D., & Rhee, K. Y. (2011) · Infection and Immunity · doi:10.1128/iai.00286-10 · Cited by 38
“tuberculosis is most commonly transmitted by inhalation of infectious aerosols into the lung with deposition in the terminal bronchioles and alveoli (28).”
BackgroundIn situ measurements of human cough aerosol hygroscopicity
Groth, R., Cravigan, L. T., Niazi, S., Ristovski, Z., & Johnson, G. R. (2021) · Journal of The Royal Society Interface · doi:10.1098/rsif.2021.0209 · Cited by 37
Multi-vent module-based adaptive ventilation to reduce cross-contamination among indoor occupants
Zhang, H., Zhang, W., Zhang, W., Xuan, Y., & Yue, Y. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.108836 · Cited by 37
Liu, X., Niu, J., Kwok, K. C. S., Wang, J. H., & Li, B. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.04.106 · Cited by 37
Risk assessment of airborne COVID-19 exposure in social settings
Ooi, C. C., Suwardi, A., Yang, Z., Xu, G. X., Tan, C. K. I., Daniel, D., Li, H., Ge, Z., Leong, F. Y., Marimuthu, K., et al. (2021) · Physics of Fluids · doi:10.1063/5.0055547 · Cited by 38
Berrouk, A. S., Lai, A. C. K., Cheung, A. C. T., & Wong, S. L. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.06.016 · Cited by 36
“[20] and Morawska [21] estimated that the shrinkage time from the original droplet to droplet nuclei is rapid and is in the order of 0.”
BackgroundGuan, J., Fu, Q., & Sharif, S. (2015) · Avian Diseases · doi:10.1637/10972-110714-reg · Cited by 36
Ishmatov, A. N. (2021) · Environmental Research · doi:10.1016/j.envres.2021.112116 · Cited by 35
Armand, P., & Tâche, J. (2022) · Scientific Reports · doi:10.1038/s41598-022-08067-6 · Cited by 35
Groma, V., Kugler, S., Farkas, Á., Füri, P., Madas, B. G., Nagy, A., Erdélyi, T., Horváth, A. Z., Müller, V., Szántó-Egész, R., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-30702-z · Cited by 36
Aerosol emission is increased in professional singingPreprint
Mürbe, D., Kriegel, M., Lange, J., Rotheudt, H., & Fleischer, M. (2020) · OSF Preprints (OSF Preprints) · doi:10.31219/osf.io/znjeh · Cited by 35
Is Office Laryngoscopy an Aerosol‐Generating Procedure?
Rameau, A., Lee, M., Enver, N., & Sulica, L. (2020) · The Laryngoscope · doi:10.1002/lary.28973 · Cited by 34
Liu, W., van Hooff, T., An, Y., Hu, S., & Chen, C. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107323 · Cited by 34
“These airborne infectious particles may be inhaled by the receptors and cause infection [8].”
Shang, Y., Dong, J., Tian, L., He, F., & Tu, J. Y. (2022) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105943 · Cited by 34
Accelerating the Lagrangian Method for Modeling Transient Particle Transport in Indoor Environments
Chen, C., Liu, W., Lin, C., & Chen, Q. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1031724 · Cited by 34
“2013), human exhalation (Nicas et al. 2005), and ozone reactions (Weschler 2006).”
BackgroundCheng, Y., Wang, C.-H., YOU, S.-H., Hsieh, N., Chen, W., Chio, C., & Liao, C. (2015) · Epidemiology and Infection · doi:10.1017/s0950268815001739 · Cited by 34
“Larger droplets are trapped increasingly in the upper respiratory tract; however, small droplets are deposited in the lower respiratory tract and the alveolar region [4, 31].”
Design and characterization of a cough simulator
Zhang, B., Zhu, C., Ji, Z., & Lin, C.-H. (2017) · Journal of Breath Research · doi:10.1088/1752-7163/aa5cc6 · Cited by 34
“The saliva ismade of distilled water, glycerin and sodium chloride with a mass ratio of 1000:76:12, referring to the mucus content reported in Nicas et al (2005).”
Method
Metadata
- Authors
- Nicas, M., Nazaroff, W. W., & Hubbard, A.
- Affiliations
- University of California, Berkeley (US)
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2005-03
- Volume
- 2
- Issue
- 3
- Pages
- 143-154
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- PMC
- PMC7196697
- OpenAlex
- W2160555964
- Cited by
- 867
- References
- 36
- Citations by year
- 2026: 23 · 2025: 55 · 2024: 56 · 2023: 75 · 2022: 100 · 2021: 149 · 2020: 93 · 2019: 12 · 2018: 22 · 2017: 17 · 2016: 20 · 2015: 25 · 2014: 21 · 2013: 34 · 2012: 24
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Centers for Disease Control and Prevention
- National Institute for Occupational Safety and Health
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Keywords
- airborne transmission, respiratory aerosols, respiratory pathogens, tuberculosis, cough, sneezing, particle size distribution, alveolar deposition, air disinfection, ventilation, superspreaders, infection risk, infectious dose, indoor air exposure
- MeSH terms
- Aerosols, Cough, Humans, Models, Theoretical, Particle Size, Pulmonary Alveoli, Risk Factors, Tuberculosis, Pulmonary, Risk Assessment, Inhalation Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.