Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Certain respiratory tract infections are transmitted through air. Coughing and sneezing by an infected person can emit pathogen-containing particles with diameters less than 10 microm that can reach the alveolar region. Based on our analysis of the sparse literature on respiratory aerosols, we estimated that emitted particles quickly decrease in diameter due to water loss to one-half the initial values, and that in one cough the volume in particles with initial diameters less than 20 microm is 60 x 10(-8) mL. The pathogen emission rate from a source case depends on the frequency of expiratory events, the respirable particle volume, and the pathogen concentration in respiratory fluid. Viable airborne pathogens are removed by exhaust ventilation, particle settling, die-off, and air disinfection methods; each removal mechanism can be assigned a first-order rate constant. The pathogen concentration in well-mixed room air depends on the emission rate, the size distribution of respirable particles carrying pathogens, and the removal rate constants. The particle settling rate and the alveolar deposition fraction depend on particle size. Given these inputs plus a susceptible person's breathing rate and exposure duration to room air, an expected alveolar dosemicrois estimated. If the infectious dose is one organism, as appears to be true for tuberculosis, infection risk is estimated by the expression: R = 1-exp(-micro). Using published tuberculosis data concerning cough frequency, bacilli concentration in respiratory fluid, and die-off rate, we illustrate the model via a plausible scenario for a person visiting the room of a pulmonary tuberculosis case. We suggest that patients termed "superspreaders" or "dangerous disseminators" are those infrequently encountered persons with high values of cough and/or sneeze frequency, elevated pathogen concentration in respiratory fluid, and/or increased respirable aerosol volume per expiratory event such that their pathogen emission rate is much higher than average.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Previous authors have noted that the viral load of human-emitted infectious aerosols may depend on sputum volume [31,42].”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atmospheric Chemistry and Physics: From Air Pollution to Climate Change
Seinfeld, J. H., Pandis, S. N., & Noone, K. (1998) · Physics Today · doi:10.1063/1.882420 · Cited by 8,731 · cited 3×
“However, if the infec-tious dose is 10 organisms, infection risk is only 1.1 × 10 −7 according to the above expression based on Equation 14 .”
BackgroundInfluentialGuideline for Isolation Precautions in Hospitals
Garner, J. S., & the Hospital Infection Control Practices Advisory Committee (1996) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700006123 · Cited by 994
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850 · cited 1×
“These studies were published by Duguid (15) in 1946, Louden and Roberts ( eq 4) in 1967, and Papineni and Rosenthal (16) in 1997.”
BackgroundThe size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 10×
“The Papineni and Rosenthal findings substantially differ from the data reported by Duguid and by Louden and Roberts (hereafter denoted L&R).”
BackgroundInfluential(2001) · Cited by 666
WELLS, W. F. (1934) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a118097 · Cited by 602 · cited 1×
“W.F. Wells (4) argued that droplets derived from respiratory fluid with d a < 100 µm rapidly evaporate to become droplet nuclei before they can be removed from air by gravitational settling.”
BackgroundDilution of Respiratory Solutes in Exhaled Condensates
EFFROS, R. M., HOAGLAND, K. W., BOSBOUS, M., CASTILLO, D., FOSS, B., DUNNING, M., GARE, M., LIN, W., & SUN, F. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2101018 · Cited by 386 · cited 2×
“The regression equation did not account for water loss from the larger particles prior to deposition onto bond paper,(13) and there was no adjustment for evaporative water loss from the smaller particles collected on the Millipore filter.”
BackgroundRiley, R. L., MILLS, C. C., O'Grady, F., SULTAN, L. U., Wittstadt, F. B., & Shivpuri, D. (1962) · PubMed · doi:10.1164/arrd.1962.85.4.511 · Cited by 313
Airborne Contagion and Air Hygiene
Phair, J. J. (1955) · American Journal of Public Health and the Nations Health · doi:10.2105/ajph.45.11.1495-c · Cited by 257
Murray, D. M., & Burmaster, D. E. (1995) · Risk Analysis · doi:10.1111/j.1539-6924.1995.tb00338.x · Cited by 250 · cited 1×
“5 ach is a typical residential air exchange rate.(31) Airborne M.”
Background
Research works printed but not linked: 6
- 4. Wells, W.F.: Onair-borne infection. Study II. Droplets and droplet nuclei. Am. J. Hyg. 20 :611-618 (1934).
- 5. Hinds, W.C.: Aerosol Technology . New York: John Wiley & Sons, Inc., 57-58:211-221 (1982).
- 7. Sonkin, L.S.: The role of particle size in experimental airborne infection. Am. J. Hyg. 53 :337-354 (1951).
- 21. Jennison, M.W.: Atomizing of mouth and nose secretions into the air as revealed by high-speed photography. In Aerobiology (Pub. No. 17). Washington, D.C.: American Association for the Advancement of Science, 1942. pp. 106-128.
- 33. Office of Research and Development: Exposure Factors Handbook (Draft). Washington, D.C.: U.S. Environmental Protection Agency, 1996. pp. 5-22.
- 36. Riley, R.L., C.C. Mills, F. O'Grady, L.U. Sultan, F. Wittstadt, and D.N. Shivpuri: Infectiousness of air from a tuberculosis ward. Am. Rev. Resp. Dis. 85 :511-525 (1962).
Cited by
Items 401–500 of 942
Xu, J., Wang, C., & Guo, H. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.109016 · Cited by 19
Indoor Air Quality Control for Airborne Diseases: A Review on Portable UV Air Purifiers
Sankurantripati, S., & Duchaine, F. (2024) · Fluids · doi:10.3390/fluids9120281 · Cited by 19
“Exhaled droplets from infected individuals typically contain soluble, non-volatile matter (Na + , K + , Cl − , lactate, and glycoprotein) comprising up to an approximately 0.71% mole fraction, in addition to viral particles [50].”
InfluentialGuo, L., Wang, M., Zhang, L., Mao, N., An, C., Xu, L., & Long, E. (2021) · Infectious Diseases Now · doi:10.1016/j.idnow.2020.11.001 · Cited by 19
Risbeck, M. J., Bazant, M. Z., Jiang, Z., Lee, Y. M., Drees, K. H., & Douglas, J. D. (2021) · Science and Technology for the Built Environment · doi:10.1080/23744731.2021.1984171 · Cited by 19
“The basic premise of the Wells-Riley model and its various extensions (Gammaitoni and Nucci, 1997; Beggs et al., 2003; Nicas et al., 2005; Noakes and Sleigh, 2009; Stilianakis and Drossinos, 2010; Bazant and Bush, 2021) is to estimate the average concentration of infectious particles in the air, calculate a total dose…”
BackgroundSobolik, J. S., Sajewski, E. T., Jaykus, L., Cooper, D. K., Lopman, B. A., Kraay, A. N. M., Ryan, P. B., & León, J. S. (2021) · Food Control · doi:10.1016/j.foodcont.2021.108632 · Cited by 19
“%) of the fluid volume expelled during a cough event (66).”
An update on ATP synthase inhibitors: A unique target for drug development in M. tuberculosis
Kelam, L. M., Wani, M. A., & Dhaked, D. K. (2023) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2023.04.009 · Cited by 19
Yu, H. C., Mui, K., & Wong, L. T. (2017) · The Journal of Computational Multiphase Flows · doi:10.1177/1757482x17746919 · Cited by 19
Wu, Y. L., Niu, J., & Liu, X. (2017) · Building Simulation · doi:10.1007/s12273-017-0388-6 · Cited by 19
“Airborne transmission is responsible for the spread of various respiratory infectious diseases, such as tuberculosis, measles, influenza, smallpox, and SARS (Riley 1974; Riley et al. 1978; Nicas et al. 2005; Li et al. 2007).”
BackgroundNie, Z., Chen, Y., & Deng, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-26837-0 · Cited by 18
Ong, S., Coleman, K. K., Chia, P. Y., Thoon, K., Pada, S., Venkatachalam, I., Fisher, D. A., Yk, T., Tan, B. H., Ng, O. T., et al. (2020) · Singapore Medical Journal · doi:10.11622/smedj.2020114 · Cited by 18
“(39) Furthermore, airborne transmission is strongly influenced by environmental factors such as airflow, ventilation, temperature and humidity, which can affect droplet desiccation and movement as well as virus stability.(40) Several studies have attempted to detect SARS-CoV-2 in air samples (Table II).”
BackgroundNumerical Modeling of Face Shield Protection against a Sneeze
Ugarte-Anero, A., Fernández‐Gámiz, U., Aramendía, Í., Zulueta, E., & López-Guede, J. M. (2021) · Mathematics · doi:10.3390/math9131582 · Cited by 18
“[27] summarizes the composition of saliva in water and non-volatile solids.”
BackgroundBorgelink, B. T. H., Carchia, A. E., Hernández-Sánchez, J. F., Caputo, D., Gardeniers, H. J. G. E., & Susarrey‐Arce, A. (2021) · Separation and Purification Technology · doi:10.1016/j.seppur.2021.120049 · Cited by 18
Numerical Investigation of Bioaerosol Transport in a Compact Lavatory
Wan, J., Wei, J., Lin, Y., & Zhang, T. (2021) · Buildings · doi:10.3390/buildings11110526 · Cited by 18
Occupants contribute to pathogens and probiotics in indoor environments
Liu, M., Gan, Z., Shen, B., Liu, L., Zeng, W., Li, Q., & Liu, H. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.108863 · Cited by 18
Yan, Y., Fang, X. Z., Li, X., Tao, Y., Yan, P., & Tu, J. Y. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109272 · Cited by 18
Ahlawat, A., Mishra, S. K., Herrmann, H., Rajeev, P., Gupta, T., Goel, V., Sun, Y., & Wiedensohler, A. (2022) · Viruses · doi:10.3390/v14071497 · Cited by 18
The effect of room air cleaners on infection control in day care centres
Vartiainen, V. A., Hela, J., Luoto, A., Nikuri, P., Sanmark, E., Taipale, A., Ehder-Gahm, I., Lastovets, N., Sormunen, P., Kulmala, I. K., et al. (2024) · Indoor Environments · doi:10.1016/j.indenv.2024.100007 · Cited by 18
Isa, M. A. (2018) · Computational Biology and Chemistry · doi:10.1016/j.compbiolchem.2018.11.002 · Cited by 18
Thomas, R. J., Webber, D. M., Collinge, A., Stagg, A. J., Bailey, S. C., Núñez, A., Gates, A. J., Jayasekera, P. N., Taylor, R. R., Eley, S., et al. (2009) · Infection and Immunity · doi:10.1128/iai.01473-08 · Cited by 18
Study on Surface Tension and Evaporation Rate of Human Saliva, Saline, and Water Droplets
Zhang, T. (2011) · The Research Repository @ WVU (West Virginia University) · doi:10.33915/etd.2271 · Cited by 18
Flattening the curve in COVID-19 using personalised protective equipment: lessons from air pollution
Rajagopalan, S., Huang, S., & Brook, R. D. (2020) · Heart · doi:10.1136/heartjnl-2020-317104 · Cited by 18
Li, Z., Ma, X., & Liao, Y. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.109351 · Cited by 17
Risk modeling for ASHRAE Standard 241-2023 — Control of infectious aerosols
Jones, B., Iddon, C. R., Zaatari, M., Wargocki, P. L., & Bruns, R. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113318 · Cited by 17
Factors affecting aerosol SARS-CoV-2 transmission via HVAC systems; a modeling study
Cotman, Z. J., Bowden, M. J., Richter, B. P., Phelps, J. H., & Dibble, C. (2021) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1009474 · Cited by 17
“5–500 μm) have been shown to carry pathogens [57].”
BackgroundMethodInfluentialExhaled Jet and Viral-Laden Aerosol Transport from Nasal Sneezing
Salati, H., Fletcher, D. F., Khamooshi, M., Dong, J., Ito, K., Vahaji, S., & Inthavong, K. (2022) · Aerosol and Air Quality Research · doi:10.4209/aaqr.210338 · Cited by 17
“, 50% of the original size for a solute content of 88 g L (Nicas et al., 2005; Anand and Phuleria, 2021)).”
SARS-CoV-2 Droplet and Airborne Transmission Heterogeneity
Baselga, M., Güemes, A., Alba, J. J., & Schuhmacher, A. J. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11092607 · Cited by 17
“The airborne model of COVID-19 disease transmission has been demonstrated [16] among small animals [17–19], from viral superspreading events [20], in long-distance transmission scenarios where infected individuals do not come into direct contact [21], by transmission in asymptomatic individuals [22], and by the preval…”
BackgroundInfluentialTzoutzas, I. G., Karoussis, I. K., & Maltezou, H. C. (2022) · Vaccines · doi:10.3390/vaccines10060847 · Cited by 17
“Large droplets can contribute to the spread of pathogens and subsequently to infection through direct contact with a contaminated surface or when an infectious patient coughs, sneezes or talks intensely [20,21].”
BackgroundInfluentialUnanswered questions on the airborne transmission of COVID-19
Gu, Z., Han, J., Zhang, L., Wang, H., Luo, X., Meng, X., Zhang, Y., Niu, X., Lan, Y., Wu, S., et al. (2023) · Environmental Chemistry Letters · doi:10.1007/s10311-022-01557-z · Cited by 17
“While biological factors Most respiratory droplets from human respiratory activities are small enough to evaporate into droplet nuclei, of less than 5 μm, within a few seconds (Johnson et al. 2009; Morawska 2006; Nicas et al. 2005; Vejerano et al. 2018).”
BackgroundTherkorn, J., Drewry, D., Pilholski, T., Shaw‐Saliba, K., Bova, G., Maragakis, L. L., Garibaldi, B. T., & Sauer, L. M. (2018) · Indoor Air · doi:10.1111/ina.12506 · Cited by 17
“44, 45 While it may seem unlikely for a patient to present with smallpox, the potential for F I G U R E 6 Layout plan for the patient room where the fluorescent tracer particles were released.”
BackgroundMandal, A., Basu, M., Das, P., Mukherjee, S., Das, S., & Roy, N. (2015) · South East Asia Journal of Public Health · doi:10.3329/seajph.v4i1.21839 · Cited by 17
Hibstu, D. T., & Bago, B. J. (2016) · Journal of Ancient Diseases & Preventive Remedies · doi:10.4172/2329-8731.1000142 · Cited by 17
“The chance of contact with a person who has an infectious form of TB, the intimacy and length of that contact, the degree of infectiousness of the case, and the divided environment in which the contact happens are all important determinants of the probability of transmission [2,12,13].”
BackgroundDroplets expelled during human expiratory activities and their origin
Morawska, L., Johnson, G. R., Ristovski, Z., Hargreaves, M. H., Mengersen, K. L., Chao, C. Y. H., Wan, M. P., Li, Y., Xie, X., & Katoshevski, D. (2008) · QUT ePrints (Queensland University of Technology) · Cited by 17
Exhaled particles from nanometre to millimetre and their origin in the human respiratory tractPreprint
Bagheri, G., Schlenczek, O., Turco, L., Thiede, B., Stieger, K., Kosub, J. M., Pöhlker, M. L., Pöhlker, C., Moláček, J., Scheithauer, S., et al. (2021) · medRxiv · doi:10.1101/2021.10.01.21264333 · Cited by 17
“This is lower than the swell factor of 6.25 reported for exocytosed airway mucus but it is higher than the value estimated by Nicas et al. (2005)[23], which is based on the rather high ∼ 9% wt solid content taken from the measurements of Effros et al. (2002) [37].”
BackgroundInfluentialXu, C., Zheng, X., Tian, F., Ding, F., & Shen, S. (2025) · Experimental and Computational Multiphase Flow · doi:10.1007/s42757-024-0232-z · Cited by 16
“The respiratory droplets are assumed to contain water, NaCl, and protein (Nicas et al., 2005).”
The SARS-COV-2 outbreak around the Amazon rainforest: The relevance of the airborne transmission.
Crema, E. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.144312 · Cited by 16
“On the other hand, further experiments visualized the production of saliva droplets during a person's normal speech, breathing, sneeze and cough (Anfinrud and Bax, 2020; Stadnytskyi et al., 2020; Nicas et al., 2005).”
Karami, S., Lakzian, E., & Ahmadi, G. (2023) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2023.03.013 · Cited by 16
Quantifying quanta: Determining emission rates from clinical data
Jones, B., Iddon, C. R., & Sherman, M. H. (2024) · Indoor Environments · doi:10.1016/j.indenv.2024.100025 · Cited by 16
Tao, S., Zhu, Y., Chen, M., & Shangguan, W. (2024) · Environment & Health · doi:10.1021/envhealth.4c00100 · Cited by 16
Dynamic assessment of the risk of airborne viral infection
Cammarata, A., & Cammarata, G. (2021) · Indoor Air · doi:10.1111/ina.12862 · Cited by 16
Rocha-Melogno, L., Crank, K. C., Bergin, M., Gray, G. C., Bibby, K. J., & Deshusses, M. A. (2021) · Environmental Technology · doi:10.1080/09593330.2021.1998228 · Cited by 16
“This common lag leads to the use of the classic Wells-Riley model [5,23] and modi fi cations [24] of airborne transmission.”
MethodPantelic, J., & Tham, K. W. (2012) · Science and Technology for the Built Environment · doi:10.1080/10789669.2012.647230 · Cited by 16
Serum Albumin/Globulin ratio in Tuberculosis and HIV Patients any Relationship?
Shingdang, J., & Bot, Y. (2016) · Mycobacterial Diseases · doi:10.4172/2161-1068.1000199 · Cited by 16
“Each one of these droplets may transmit the disease, since the infectious dose of tuberculosis is very low (the inhalation of fewer than 10 bacteria may cause an infection) [5].”
BackgroundLi, J., Li, C., & Tang, H. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.104255 · Cited by 16
“16d0 [46]; and Cvirus is the virus concentration in the expelled fluid by the infector, RNA copies/mL.”
BackgroundInfluentialInfluence of Film Dimensions on Film Droplet Formation
Holmgren, H., & Ljungström, E. (2011) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2011.0892 · Cited by 16
Computational modeling of tuberculous meningitis reveals an important role for tumor necrosis
El-Kebir, M., van der Kuip, M., van Furth, A. M., & Kirschner, D. E. (2013) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2013.03.008 · Cited by 16
“Inhalation of a single droplet containing just a few bacteria can lead to pulmonary infection (Nicas et al., 2005; Behr et al., 1999).”
BackgroundLiu, X., Wu, M., An, Z., & Chen, T. (2022) · Sustainable Cities and Society · doi:10.1016/j.scs.2022.103860 · Cited by 15
Aggravated exposure risks of children to multipath transmitted pathogens in indoor environments
Liu, Z., Hu, L., Hu, C., Liu, Q. S., Liang, Z., Rong, R., & Liu, H. (2023) · iScience · doi:10.1016/j.isci.2023.108433 · Cited by 15
Dynamics and Viability of Airborne Respiratory Syncytial Virus under Various Indoor Air Conditions
Niazi, S., Groth, R., Morawska, L., Spann, K. M., & Ristovski, Z. (2023) · Environmental Science & Technology · doi:10.1021/acs.est.3c03455 · Cited by 15
Revisiting the Wells-Riley airborne infection model: A critical analysis of its use and misuse
Sedighi, A. A., Nardell, E. A., Nasiri, F., & Haghighat, F. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113136 · Cited by 15
Chen, W., Kwak, D.-B., Anderson, J. E., Kanna, K., Pei, C., Cao, Q., Ou, Q., Kim, S. C., Kuehn, T. H., & Pui, D. Y. H. (2021) · Aerosol and Air Quality Research · doi:10.4209/aaqr.210232 · Cited by 15
“3 μm which represents airborne coughing droplet size (Nicas et al., 2005; Papineni and Rosenthal, 1997; Zayas et al., 2012).”
BackgroundMethodInfluentialZheng, J., Tao, Q., & Chen, Y. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109586 · Cited by 15
“The impact of the location of louvers on airflow characteristics and pollutant dispersion is evaluated and then the infection risk of SARS-CoV-2 is discussed for different source units.”
BackgroundInfluentialComparison of the survival of different isolates of SARS-CoV-2 in evaporating aerosols
Dabisch, P. A., Wood, S., Holland, B., Boydston, J. A., Beck, K. E., Green, B., & Biryukov, J. (2022) · Aerosol Science and Technology · doi:10.1080/02786826.2022.2128712 · Cited by 15
“…into the environment, water present in the particle is rapidly lost through evaporation, resulting in a decrease to a new equilibrium particle size post-exhalation (Bourouiba 2020; Bourouiba, Dehandschoewercker, and Bush 2014; Liu et al. 2017; Nicas, Nazaroff, and Hubbard 2005; Figure 1).”
BackgroundKwak, D.-B., Fischer, H. D., & Pui, D. Y. H. (2023) · Aerosol and Air Quality Research · doi:10.4209/aaqr.220409 · Cited by 15
“Therefore, both model (Liu et al., 2017; Nicas et al., 2005) needs to be further improved for predicting the ratio of saliva residue size to saliva initial droplet size.”
Kušan, A. C., Baranašić, J., Frka, S., Lucijanić, T., Šribar, A., Knežević, J., Buonanno, G., & Stabile, L. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.164642 · Cited by 15
“For bioaerosols with an initial diameter of <20 μm, desiccation at a relative humidity of 50 % occurs in <1 s (Nicas et al., 2005; Tellier, 2022; Xie et al., 2007) and the infectivity of aerosolized viruses could persist for hours.”
Liu, Z., Huang, Z., Chu, J., Li, H., He, J., Lin, C., Jiang, C., Yao, G., & Fan, S. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110867 · Cited by 15
Size distribution and sites of origin of droplets expelled during expiratory activities
Morawska, L., Johnson, G. R., Ristovski, Z., Hargreaves, M. H., Mengersen, K. L., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · Cited by 15
Numerical Study of the Respiratory Aerosols Transportation in Ventilated Classroom
Feng, G. H., Zhang, Y., & Lan, X. Y. (2012) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.204-208.4298 · Cited by 15
Value of FDG-PET/CT for treatment response in tuberculosis: a systematic review and meta-analysis
Sjölander, H., Strømsnes, T. A., Gerke, O., & Hess, S. (2017) · Clinical and Translational Imaging · doi:10.1007/s40336-017-0259-2 · Cited by 15
“TB spreads via respiratory droplets, and subsequently infects the lower airways and complementary lymphatic system [9].”
Bathula, S., Anand, S., Thajudeen, T., Mayya, Y. S., Chaudhury, P., & Shashank, C. (2021) · Aerosol and Air Quality Research · doi:10.4209/aaqr.200547 · Cited by 15
“The total number of wet droplets released in a single sneeze is ~106, and the lognormal fit of this Duguid’s sneeze data gives a CMD of 8.1 µm with GSD = 2.3 (Nicas et al., 2005).”
BackgroundInfluentialYarahmadi, R., Bokharaei‐Salim, F., Soleimani-Alyar, S., Moridi, P., MoradiMoghaddam, O., Lahiji, M. N., Darvishi, M.-M., Golmahammadi, S., Mousavi, S. A., Ebrahimi, H., et al. (2021) · International Journal of Environmental Science and Technology · doi:10.1007/s13762-020-03095-z · Cited by 15
Sussman, R. A., Golberstein, E., & Polosa, R. (2021) · Applied Sciences · doi:10.3390/app11146355 · Cited by 15
“01 s) that in practice can be considered as instantaneous, with the emitted droplets being overwhelmingly desiccated droplet nuclei made of salt crystals and lypoproteins and being about roughly half their original diameter (see [88]).”
BackgroundAnalysis of Hazard Rate of Municipalities in Slovakia in Terms of COVID-19
Petrovič, F., Vilinová, K., & Hilbert, R. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18179082 · Cited by 15
“Several studies on the number and size of the saliva droplets and other secretions from the respiratory tract have been published [3,4].”
BackgroundFreeman, A. L. J., Parker, S. T., Noakes, C. J., Fitzgerald, S., Smyth, A., Macbeth, R., Spiegelhalter, D. J., & Rutter, H. (2021) · BMJ Open · doi:10.1136/bmjopen-2021-050869 · Cited by 15
Personal protective equipment and possible routes of airborne spread during the COVID ‐19 pandemic
Brown, J., & Pope, C. (2020) · Anaesthesia · doi:10.1111/anae.15097 · Cited by 15
“9% of the fluid volume ejected during a cough is in large particles [3].”
BackgroundClauß, M., & Clauß, M. (2020) · RePEc: Research Papers in Economics · doi:10.22004/ag.econ.301142 · Cited by 16
“This process has been thoroughly investigated in humans (Duguid 1946, Loudon & Roberts 1967, Papineni & Rosenthal 1997, Nicas et al. 2005, Yang et al. 2007, Gralton et al. 2011).”
BackgroundWagner, J., Macher, J. M., Chen, W., & Kumagai, K. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192315555 · Cited by 14
Otero-Fernandez, M., Thomas, R. J., Oswin, H. P., Alexander, R. C., Haddrell, A. E., & Reid, J. P. (2024) · Atmosphere · doi:10.3390/atmos15040511 · Cited by 14
“…growth conditions, and surface-active compounds in aerosol droplets can influence the viability of microbes, providing some protection against desiccation at a low RH, UV light, oxygen toxicity, high salt concentrations and even the droplet surface forces at the air–particle interface [33,35–37].”
BackgroundNateghi, S., Marashian, S., Kaczmarczyk, J., & Sadrizadeh, S. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112336 · Cited by 14
McKay, B., Ebell, M. H., Dale, A. P., Shen, Y., & Handel, A. (2020) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.2020.0496 · Cited by 14
Ahmed, J., Harker, A. H., & Edirisinghe, M. J. (2020) · Medical Devices & Sensors · doi:10.1002/mds3.10120 · Cited by 14
“The act of coughing or sneezing can generate a substantial number of particles which mostly fall within the 5-10 µm range (Nicas et al., 2005).”
BackgroundPetrosino, F., Mukherjee, D., Coppola, G., Gaudio, M. T., Curcio, S., Calabrò, V., Marra, F., Bhattacharya, P., Pal, U., Khélifi, N., et al. (2021) · Euro-Mediterranean Journal for Environmental Integration · doi:10.1007/s41207-021-00251-w · Cited by 14
“Air turbulence is directly proportional to the time taken for enveloped virus (SARS-CoV-2) to settle down (Nicas et al. 2005).”
BackgroundHome quarantine: A numerical evaluation of SARS‐CoV‐2 spread in a single‐family house
Picard, C., Salis, L. C. R., & Abadie, M. (2022) · Indoor Air · doi:10.1111/ina.13035 · Cited by 14
Song, Y., Yang, H., Li, H., Chen, H., Shen, S., Hou, Y., & Wang, J. (2023) · Environmental Science and Pollution Research · doi:10.1007/s11356-023-27614-w · Cited by 14
“Table 1 Droplets properties used in discrete phase model (Nicas et al. 2005; Borro et al. 2020; Gupta et al. 2011)”
MethodRespirable Bacteriophage Aerosols for the Prevention and Treatment of Tuberculosis
Hatfull, G. F., & Vehring, R. (2016) · Wiley eBooks · doi:10.1002/9781118943182.ch14 · Cited by 14
The Potential for Airborne Transmission of SARS-CoV-2 in Sport: A Cricket Case Study
England, R., Peirce, N. S., Wedatilake, T., Torresi, J., Kemp, S. P. T., Cook, M., Mitchell, S., & Harland, A. R. (2021) · International Journal of Sports Medicine · doi:10.1055/a-1342-8071 · Cited by 14
“A large volume of aerosol would be required to match the viral load of a much smaller number of larger droplets [41].”
BackgroundBoundary conditions for exhaled airflow from a cough with a surgical or N95 mask
Pan, Y., Zhang, H., Niu, Z., An, Y., & Chen, C. (2022) · Indoor Air · doi:10.1111/ina.13088 · Cited by 14
A computational framework for transmission risk assessment of aerosolized particles in classrooms
Tan, K., Gao, B., Yang, C.-H., Johnson, E. L., Hsu, M., Passalacqua, A., Krishnamurthy, A., & Ganapathysubramanian, B. (2023) · Engineering With Computers · doi:10.1007/s00366-022-01773-9 · Cited by 13
Webner, F., Shishkin, A., Schmeling, D., & Wagner, C. D. (2024) · Indoor Air · doi:10.1155/2024/9927275 · Cited by 13
Li, X., Mak, C. M., Ai, Z., Ma, K. W., & Wong, H. M. (2024) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2024.135338 · Cited by 13
Du, L., Wan, Z., Guo, L., Chen, T., Yang, C., & Zhu, Z.-L. (2025) · Environmental Pollution · doi:10.1016/j.envpol.2025.125645 · Cited by 13
Data-driven control of airborne infection risk and energy use in buildings
Risbeck, M. J., Cohen, A. E., Douglas, J. D., Jiang, Z., Fanone, C., Bowes, K., Doughty, J., Turnbull, M., DiBerardinis, L. J., Lee, Y. M., et al. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110893 · Cited by 13
Mohaimin, A. Z., Krishnamoorthy, S., & Shivanand, P. (2023) · Brazilian Journal of Microbiology · doi:10.1007/s42770-023-01179-9 · Cited by 13
“…day-to-day activities and also due to coughing, sneezing, talking, and breathing which could expel human respiratory and oral microbiota[221, 275, 417, 616], the skin microbes as a result of skin aberrations and shedding activities [175, 348, 421], and floor dusts rich in pathogenic microbes…”
Liu, Z., Lin, C., Shi, J., Ding, M., Liu, H., Chu, J., Li, H., Huang, Z., Xiao, X., Wan, T., et al. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.109885 · Cited by 13
Yang, Y., Sze-To, G. N., & Chao, C. Y. H. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2011.604108 · Cited by 13
“where d ′ D is the droplet nucleus size, dD is the initial droplet size, and h is the ratio of the droplet nucleus size to the initial droplet size, which is determined from the weighting of the nonvolatile content to the water content of the respiratory fluid and the humidity of air (Nicas et al. 2005).”
BackgroundMethodInfluentialUnderstanding droplets produced by nebulisers and respiratory activities
Li, Y., Chwang, A. T., Seto, W., Ho, P., & Yuen, P. L. (2008) · Hong Kong Medical Journal · Cited by 13
Are tracheal intubation and extubation aerosol‐generating procedures?
Nestor, C. C., Wang, S., & Irwin, M. G. (2020) · Anaesthesia · doi:10.1111/anae.15328 · Cited by 13
“Whether or not these pose a clinically significant risk depends on the number, size and concentration of infectious aerosols [5].”
BackgroundPallarès, J., & Fabregat, A. (2022) · Indoor and Built Environment · doi:10.1177/1420326x211060001 · Cited by 13
“Neglecting the buoyancy effect, expressions for the jet flow are as described by equations (6)–(8)(13,44)”
MethodJones, R. M., & Nicas, M. (2009) · Aerosol Science and Technology · doi:10.1080/02786820903036322 · Cited by 13
“…bacteria are typically less than 0.2 µm and 10 µm in diameter, respectively, they are emitted via coughs and sneezes in association with respiratory fluids: These expiratory particles vary in size by several orders of magnitude (Duguid 1946; Loudon and Roberts 1967; Nicas et al. 2005).”
BackgroundSelf-citationMovement and transmission of human exhaled droplets/droplet nuclei
Dai, H., & Zhao, B. (2020) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/tb-2020-0643 · Cited by 13
Robinson, M., Drossinos, Y., & Stilianakis, N. I. (2013) · Epidemics · doi:10.1016/j.epidem.2013.01.001 · Cited by 13
“dS dt = ψ(1− S − I)− R0 α IS, (26) dI dt = R0 α IS − I, (27)”
BackgroundMethodInfluentialLiu, H., Liu, Z., Yao, G., Dong, Z., Jiang, C., Liu, J., Rong, R., He, J., Hu, C., Li, S., et al. (2025) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2025.137601 · Cited by 12
Girolamo, P. D. (2020) · Bulletin of Atmospheric Science and Technology · doi:10.1007/s42865-020-00024-3 · Cited by 12
“…and the minimum infectious dose necessary to transmit COVID-19, although preliminary ongoing studies on SARS-CoV-2 and previous studies focusing on other viral respiratory pathologies indicated that very low virus loads can initiate infection (Nicas et al. 2005, see Section 4 for more details).”
Evaluation of human walking-induced resuspension of bacteria on different flooring materials
Yang, S. Y., Zhang, H., Hsiao, T.-C., Ferro, A. R., & Lai, A. C. K. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110218 · Cited by 12
Pan, Y., Huang, W., Dai, H. K., Bian, Y., Ho, K., & Chen, C. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.166099 · Cited by 12
Xu, C., Ren, Y., Li, N., Liu, L., Mei, X., & Fan, Y. (2023) · Building Simulation · doi:10.1007/s12273-023-1035-z · Cited by 12
“The evaporation process of exhaled droplets from the breathing was not considered as the evaporation time was indicated extremely fast with an initial diameter of ≤1 m (Nicas et al. 2005).”
BackgroundMyers, M. R., Hariharan, P., Guha, S., & Yan, J. (2016) · Mathematical Medicine and Biology A Journal of the IMA · doi:10.1093/imammb/dqw018 · Cited by 12
Bioaerosol research: Yesterday, today and tomorrow
Zheng, Y., Li, J., Chen, H., Zhang, T., Li, X., Wang, M., & Yao, M. (2018) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/n972018-00121 · Cited by 12
Singleton, M. N., & Soffin, E. M. (2020) · Regional Anesthesia & Pain Medicine · doi:10.1136/rapm-2020-101653 · Cited by 13
“27 Cough, a hallmark feature of COVID-19, is expected to occur throughout a procedure performed under RA with sedation.”
Respiratory droplet resuspension near surfaces: Modeling and analysis
Nikfar, M., Paul, R., Islam, K., Razizadeh, M., Jagota, A., & Liu, Y. (2021) · Journal of Applied Physics · doi:10.1063/5.0050447 · Cited by 12
Fu, L., Yang, M., Niu, J., Ren, W., & You, R. (2021) · Indoor Air · doi:10.1111/ina.12952 · Cited by 12
Metadata
- Authors
- Nicas, M., Nazaroff, W. W., & Hubbard, A.
- Affiliations
- University of California, Berkeley (US)
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2005-03
- Volume
- 2
- Issue
- 3
- Pages
- 143-154
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- PMC
- PMC7196697
- OpenAlex
- W2160555964
- Cited by
- 867
- References
- 36
- Citations by year
- 2026: 23 · 2025: 55 · 2024: 56 · 2023: 75 · 2022: 100 · 2021: 149 · 2020: 93 · 2019: 12 · 2018: 22 · 2017: 17 · 2016: 20 · 2015: 25 · 2014: 21 · 2013: 34 · 2012: 24
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Centers for Disease Control and Prevention
- National Institute for Occupational Safety and Health
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Keywords
- airborne transmission, respiratory aerosols, respiratory pathogens, tuberculosis, cough, sneezing, particle size distribution, alveolar deposition, air disinfection, ventilation, superspreaders, infection risk, infectious dose, indoor air exposure
- MeSH terms
- Aerosols, Cough, Humans, Models, Theoretical, Particle Size, Pulmonary Alveoli, Risk Factors, Tuberculosis, Pulmonary, Risk Assessment, Inhalation Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.