Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Certain respiratory tract infections are transmitted through air. Coughing and sneezing by an infected person can emit pathogen-containing particles with diameters less than 10 microm that can reach the alveolar region. Based on our analysis of the sparse literature on respiratory aerosols, we estimated that emitted particles quickly decrease in diameter due to water loss to one-half the initial values, and that in one cough the volume in particles with initial diameters less than 20 microm is 60 x 10(-8) mL. The pathogen emission rate from a source case depends on the frequency of expiratory events, the respirable particle volume, and the pathogen concentration in respiratory fluid. Viable airborne pathogens are removed by exhaust ventilation, particle settling, die-off, and air disinfection methods; each removal mechanism can be assigned a first-order rate constant. The pathogen concentration in well-mixed room air depends on the emission rate, the size distribution of respirable particles carrying pathogens, and the removal rate constants. The particle settling rate and the alveolar deposition fraction depend on particle size. Given these inputs plus a susceptible person's breathing rate and exposure duration to room air, an expected alveolar dosemicrois estimated. If the infectious dose is one organism, as appears to be true for tuberculosis, infection risk is estimated by the expression: R = 1-exp(-micro). Using published tuberculosis data concerning cough frequency, bacilli concentration in respiratory fluid, and die-off rate, we illustrate the model via a plausible scenario for a person visiting the room of a pulmonary tuberculosis case. We suggest that patients termed "superspreaders" or "dangerous disseminators" are those infrequently encountered persons with high values of cough and/or sneeze frequency, elevated pathogen concentration in respiratory fluid, and/or increased respirable aerosol volume per expiratory event such that their pathogen emission rate is much higher than average.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Previous authors have noted that the viral load of human-emitted infectious aerosols may depend on sputum volume [31,42].”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atmospheric Chemistry and Physics: From Air Pollution to Climate Change
Seinfeld, J. H., Pandis, S. N., & Noone, K. (1998) · Physics Today · doi:10.1063/1.882420 · Cited by 8,731 · cited 3×
“However, if the infec-tious dose is 10 organisms, infection risk is only 1.1 × 10 −7 according to the above expression based on Equation 14 .”
BackgroundInfluentialGuideline for Isolation Precautions in Hospitals
Garner, J. S., & the Hospital Infection Control Practices Advisory Committee (1996) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700006123 · Cited by 994
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850 · cited 1×
“These studies were published by Duguid (15) in 1946, Louden and Roberts ( eq 4) in 1967, and Papineni and Rosenthal (16) in 1997.”
BackgroundThe size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 10×
“The Papineni and Rosenthal findings substantially differ from the data reported by Duguid and by Louden and Roberts (hereafter denoted L&R).”
BackgroundInfluential(2001) · Cited by 666
WELLS, W. F. (1934) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a118097 · Cited by 602 · cited 1×
“W.F. Wells (4) argued that droplets derived from respiratory fluid with d a < 100 µm rapidly evaporate to become droplet nuclei before they can be removed from air by gravitational settling.”
BackgroundDilution of Respiratory Solutes in Exhaled Condensates
EFFROS, R. M., HOAGLAND, K. W., BOSBOUS, M., CASTILLO, D., FOSS, B., DUNNING, M., GARE, M., LIN, W., & SUN, F. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2101018 · Cited by 386 · cited 2×
“The regression equation did not account for water loss from the larger particles prior to deposition onto bond paper,(13) and there was no adjustment for evaporative water loss from the smaller particles collected on the Millipore filter.”
BackgroundRiley, R. L., MILLS, C. C., O'Grady, F., SULTAN, L. U., Wittstadt, F. B., & Shivpuri, D. (1962) · PubMed · doi:10.1164/arrd.1962.85.4.511 · Cited by 313
Airborne Contagion and Air Hygiene
Phair, J. J. (1955) · American Journal of Public Health and the Nations Health · doi:10.2105/ajph.45.11.1495-c · Cited by 257
Murray, D. M., & Burmaster, D. E. (1995) · Risk Analysis · doi:10.1111/j.1539-6924.1995.tb00338.x · Cited by 250 · cited 1×
“5 ach is a typical residential air exchange rate.(31) Airborne M.”
Background
Research works printed but not linked: 6
- 4. Wells, W.F.: Onair-borne infection. Study II. Droplets and droplet nuclei. Am. J. Hyg. 20 :611-618 (1934).
- 5. Hinds, W.C.: Aerosol Technology . New York: John Wiley & Sons, Inc., 57-58:211-221 (1982).
- 7. Sonkin, L.S.: The role of particle size in experimental airborne infection. Am. J. Hyg. 53 :337-354 (1951).
- 21. Jennison, M.W.: Atomizing of mouth and nose secretions into the air as revealed by high-speed photography. In Aerobiology (Pub. No. 17). Washington, D.C.: American Association for the Advancement of Science, 1942. pp. 106-128.
- 33. Office of Research and Development: Exposure Factors Handbook (Draft). Washington, D.C.: U.S. Environmental Protection Agency, 1996. pp. 5-22.
- 36. Riley, R.L., C.C. Mills, F. O'Grady, L.U. Sultan, F. Wittstadt, and D.N. Shivpuri: Infectiousness of air from a tuberculosis ward. Am. Rev. Resp. Dis. 85 :511-525 (1962).
Cited by
Items 501–600 of 942
The effect of body position while coughing on the airborne transmission of pathogens
Amjadimanesh, H., Norouzi, M. H., Johnson, M. S., Sadrizadeh, S., & Abouali, O. (2022) · Physics of Fluids · doi:10.1063/5.0086241 · Cited by 12
Evaluation of the Influenza Risk Reduction from Antimicrobial Spray Application on Porous Surfaces
Chabrelie, A., Mitchell, J., Rose, J. B., Charbonneau, D. L., & Ishida, Y. (2017) · Risk Analysis · doi:10.1111/risa.12952 · Cited by 12
“44 [mL] Point value Highest volume(61) taken from literature.”
BackgroundToghraei, A., & Romanić, D. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113335 · Cited by 11
SARS-CoV-2 and the nose: Risks and implications for primary care
Campbell, R. G. (2020) · Australian Journal of General Practice · doi:10.31128/ajgp-05-20-5452 · Cited by 11
Zhong, Z., Pan, Z., Tang, H., Wang, J., Liu, F., & Wang, J. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110670 · Cited by 12
D’Alicandro, A. C., Capozzoli, A., & Mauro, A. (2023) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2023.106285 · Cited by 11
Oh, W., Ooka, R., Kikumoto, H., & Lee, S. (2023) · Aerosol Science and Technology · doi:10.1080/02786826.2023.2271954 · Cited by 11
“The droplets and droplet nuclei consist of 98.2% H 2 O and 1.8% nuclei (mass ratio) (Nicas, Nazaroff, and Hubbard 2005), and the ejected particles evaporate rapidly.”
MethodInfluentialReissner, J., Siller, P., Bartel, A., Roesler, U. H., & Friese, A. (2023) · Scientific Reports · doi:10.1038/s41598-023-49361-1 · Cited by 11
“The particle diameter that distinguishes larger droplets from droplet nuclei is usually considered to be 5 µm, although some studies have used a cut-off size of 10 µm as these particles are able to deposit in the lower respiratory tract 6,17 .”
BackgroundZhang, P., Su, X., Lu, J. W. Z., He, K., Gao, G., & Wu, F. (2025) · Physics of Fluids · doi:10.1063/5.0247620 · Cited by 11
Human Research Study of Particulate Propagation Distance From Human Respiratory Function
Reyes, J., Stiehl, B., Delgado, J., Kinzel, M., & Ahmed, K. A. (2022) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiab609 · Cited by 11
Experimental Evaluation of a Markov Multizone Model of Particulate Contaminant Transport
Jones, R. M., & Nicas, M. (2014) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meu056 · Cited by 11
“Sajo experiment and model The environment studied by Sajo et al. (2002) was the two-story lobby of a university building, which contained no furniture or human activity.”
BackgroundSelf-citationWu, Y. L., Tung, T. C. W., & Niu, J. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.01.028 · Cited by 11
Attachment of human adenovirus onto household paints
Dang, H. T. T., & Tarabara, V. V. (2021) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2021.111812 · Cited by 11
Bayram, A., & Korobenko, A. (2021) · Atmospheric Environment · doi:10.1016/j.atmosenv.2021.118857 · Cited by 11
Katal, A., Albettar, M., & Wang, L. L. (2021) · medRxiv · doi:10.1101/2021.01.19.21250046 · Cited by 11
“The aerosol infection risk calculation is based on the modified Wells-Riley formulation [30,31].”
MethodWu, D., Chen, J., Fu, X., Li, Z., Tan, F., & Lin, H. (2023) · PLoS ONE · doi:10.1371/journal.pone.0290288 · Cited by 10
“9kg/m(3), 37 ̊Cand 92% respectively [30].”
Armand, P., & Tâche, J. (2025) · Scientific Reports · doi:10.1038/s41598-024-84411-2 · Cited by 10
Xu, R., Wu, F., Shen, L., Pan, X., Yu, J., & Huang, Y. (2025) · Physics of Fluids · doi:10.1063/5.0260987 · Cited by 10
Saad, M. A., Hassan, A. A., Hanafy, A., Salem, M. H., & William, M. A. (2025) · Scientific Reports · doi:10.1038/s41598-025-08394-4 · Cited by 10
Avian and swine influenza viruses
Tang, C. Y., Ramesh, A. K., & Wan, X. (2024) · Elsevier eBooks · doi:10.1016/b978-0-12-818619-0.00093-9 · Cited by 10
Luo, D., Luo, Z., Zheng, X., & Qian, H. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111406 · Cited by 10
Nagy, A., Czitrovszky, A., Lehoczki, A., Farkas, Á., Füri, P., Osán, J., Groma, V., Kugler, S., Micsinai, A., Horváth, A. Z., et al. (2024) · GeroScience · doi:10.1007/s11357-024-01379-7 · Cited by 10
“Many studies presented numerical models that tried to describe the interplay of sedimentation and evaporation of the particles emitted from the respiratory tract (e.g., [52, 80, 82, 83]).”
Park, S., & Rim, D. (2024) · Scientific Reports · doi:10.1038/s41598-024-75245-z · Cited by 10
“Our study focused specifically on 1 μm with a density of 1000 kg·m − 3 , as this size is predominant during talking, and particles in the 1–4 μm range exhibit similar behavior in the air 26,29,31 .”
BackgroundEstimating the reduction in SARS-CoV-2 viral load by common face masks with a simple leak model
Freitag, S., Howell, S. G., & Jim, K. T. C. (2022) · Aerosol Science and Technology · doi:10.1080/02786826.2022.2053656 · Cited by 10
Li, H., Lan, Y., Ma, X., Kong, X., & Fan, M. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105728 · Cited by 10
“The diameter of exhaled aerosols ranges from 1μm to 1000μm, with most droplet nuclei falling in the 1-10μm size range([36]).”
The effects of desk-partition layout on cough droplet dynamics relating to seasonal influenza
Norvihoho, L. K., Yin, J. H., Liu, Y., Yu, H.-T., Jiang, Y., Zhou, Z., & Chen, B. (2024) · Physics of Fluids · doi:10.1063/5.0186922 · Cited by 10
Mao, S., & Celik, I. B. (2010) · Computers & Fluids · doi:10.1016/j.compfluid.2010.03.010 · Cited by 10
“Bio-aerosols have been referred as an important mode of transmission of influenza by many researchers (Tellier, 2006, and references therein; Nicas et al., 2005; Beggs, 2003; Brachman, 1990; Riley, 1974).”
BackgroundFlorez, F. L. E., Thibodeau, T., Oni, T. M., Floyd, E. L., KHAJOTIA, S. S., & Cai, C. (2021) · Physics of Fluids · doi:10.1063/5.0056229 · Cited by 10
Jung, M., Chung, W. J., Sung, M., Jo, S., & Hong, J. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19052512 · Cited by 10
Yılmaz, B. Ç., & Yılmaz, Y. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109227 · Cited by 10
Vega, P. J. O., Lucesoli, A., Mosca, G., Giulietti, R. A., D’Errico, M. M., & Gambale, A. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111557 · Cited by 9
Khamar, P. M., Shetty, R., Balakrishnan, N., Kabi, P., Roy, D., Basu, S., & Roy, A. S. (2020) · Journal of Cataract & Refractive Surgery · doi:10.1097/j.jcrs.0000000000000326 · Cited by 9
“Theoretically, even a single virus might be sufficient to transmit a respiratory infection.(27) The excimer laser ablation plume did not seem to transmit the human immunodeficiency virus, herpes virus, and varicella zoster virus because they did not seem to survive the ablation.”
BackgroundTRANSPORT OF AEROSOL BY COUGHING IN AN AIR-CONDITIONED SPACE
Zhang, B., Guo, G., Zhu, C., & Ji, Z. (2019) · Proceeding of Second Thermal and Fluids Engineering Conference · doi:10.1615/tfec2019.hbe.028480 · Cited by 9
Hofer, S., Hofstätter, N., Duschl, A., & Himly, M. (2021) · Journal of Personalized Medicine · doi:10.3390/jpm11050431 · Cited by 9
“However, it is proposed for other viral respiratory infections that a single virus can serve for disease initiation [39].”
BackgroundNumerical Simulation of the Novel Coronavirus Spread in Commercial Aircraft Cabin
Zhang, M., Yu, N., Zhang, Y., Zhang, X., & Cui, Y. (2021) · Processes · doi:10.3390/pr9091601 · Cited by 9
“Most of the droplets from coughing change to droplet nuclei (≤5 μm) in less than 1 s, and the diameter becomes about 1/3 of the original [26].”
BackgroundConcept Design of a High-Voltage Electrostatic Sanitizer to Prevent Spread of COVID-19 Coronavirus
Behjat, V., Rezaei‐Zare, A., Fofana, I., & Jahromi, A. N. (2021) · Energies · doi:10.3390/en14227808 · Cited by 9
Anand, S., Krishan, J., Sreekanth, B., & Mayya, Y. S. (2022) · Scientific Reports · doi:10.1038/s41598-022-17693-z · Cited by 9
Air curtain as a SARS-CoV-2 spreading mitigation method in a small aircraft cabin
Kurec, K., Olszański, B. M., Gumowski, K., Klamka, M., Remer, M., Piechna, J. R., & Kubacki, S. (2023) · Proceedings of the Institution of Mechanical Engineers Part G Journal of Aerospace Engineering · doi:10.1177/09544100231153703 · Cited by 9
“It translates into a 3–5 times reduction in the droplet’s initial diameter.(70) On the other hand, through neglection of the evaporation process, which slightly lowers the computational cost of each iteration, all droplet trajectories (even the smallest ones with their initial diameter held constant) can still be trac…”
BackgroundYoo, S., Yamauchi, S., Park, H.-G., & Ito, K. (2023) · Fluids · doi:10.3390/fluids8090253 · Cited by 9
Zhao, Y., Gu, C., Song, X., Luo, Z., & Wang, J. (2023) · Atmospheric Pollution Research · doi:10.1016/j.apr.2023.102006 · Cited by 9
An Analysis on the Detection of Biological Contaminants Aboard Aircraft
Hwang, G. M., DiCarlo, A. A., & Lin, G. C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0014520 · Cited by 9
“Prior calculations by Nicas [32], using data from Loudon and Rosenthal, estimated a V20 of 6610 - 8 ml for one cough.”
BackgroundMethodInfluentialNasiru, A., Hafsat, I. G., Mohammad, M., & Sabo, A. (2012) · International Journal of Bioscience Biochemistry and Bioinformatics · doi:10.7763/ijbbb.2012.v2.131 · Cited by 9
Improving Filtration Efficacy of Medical Face Masks
Kulmala, I. K., Heinonen, K., & Salo, S. (2021) · Aerosol and Air Quality Research · doi:10.4209/aaqr.210043 · Cited by 9
“The viral particles emitted during coughing and sneezing by a person with respiratory infection are mainly in large droplets (Nicas et al., 2005).”
Ge, T., & Cheng, S. (2021) · PubMed Central · doi:10.3877/cma.j.issn.2096-112x.2021.01.003 · Cited by 9
You, S., Chen, S., Wang, C.-H., & Liao, C. (2013) · Journal of Epidemiology · doi:10.2188/jea.je20120031 · Cited by 9
Dembry, L., & Torres‐Viera, C. (2011) · Wiley eBooks · doi:10.1002/9781118063842.ch3 · Cited by 9
Conceição, S. T. (2012) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.3.2012.tde-13062013-164203 · Cited by 9
Housing as a determinant of health in The Sayisi Dene First Nation, Tadoule Lake, Manitoba
Boutilier, D. (2013) · Mspace (University of Manitoba) · Cited by 9
Development of Multi-Scale City Building Energy Model for Urban Climate Resilience
Katal, A. (2020) · Spectrum Research Repository (Concordia University) · Cited by 9
Li, J. H., Yang, Y., Zhang, M., Wen, Y., & Zhang, Y. (2025) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2025.107356 · Cited by 8
Xu, R., Wu, F., Shen, L., Pan, X., Huang, Z., Yu, J., & Huang, Y. (2025) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2025.107387 · Cited by 8
A physicist's approach to COVID-19 transmission via expiratory droplets
Carelli, P. (2020) · Medical Hypotheses · doi:10.1016/j.mehy.2020.109997 · Cited by 8
Lv, Y., Chen, X., Wu, W., Wu, F., Wu, X., Yuan, W., & Qu, C. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112108 · Cited by 8
Source Case Identification and Control of Tuberculosis by Molecular Epidemiology
Asgharzadeh, M., Kafil, H. S., & poorostadi, M. (2014) · Majallah-i dānishgāh-i ̒ulūm-i pizishkī-i Māzandarān/Journal of Mazandaran University of Medical Sciences · Cited by 8
Coronavirus Infection Prevention by Wearing Masks
Vo, T. S., Vo, T. T. T. N., & Vo, T. T. B. C. (2020) · Eurasian Journal of Medicine · doi:10.5152/eurasianjmed.2020.20056 · Cited by 8
“According to some references, the velocity of the exhaled air in sneezing is much larger than that of breathing and coughing [18-20], and the created total number of droplets during the sneeze is also larger than that of other respiratory activities [21]; one can refer to some references of the distribution of size of…”
BackgroundPersonal Protective Equipment for COVID-19
Gopalakrishnan, M., Punitha, V., Prema, R., Niveathitha, S., & Saravanan, D. (2021) · Environmental footprints and eco-design of products and processes · doi:10.1007/978-981-16-3856-5_7 · Cited by 8
The aerodynamic behavior of respiratory aerosols within a general patient room
Grosskopf, K., & Herstein, K. (2012) · Science and Technology for the Built Environment · doi:10.1080/10789669.2011.587586 · Cited by 8
“Since infections in the alveolar region of the lung are generally caused by pathogencarrying particles da < 10 µm, only droplets da < 20 µm can produce nuclei capable of causing infections in the alveoli (Nicas et al. 2005).”
BackgroundInfluentialPrevention of COVID-19 Infection with Personal Protective Equipment
Shimasaki, N., & Morikawa, H. (2021) · Journal of Disaster Research · doi:10.20965/jdr.2021.p0061 · Cited by 8
Сафатов, А. С., Алексеевна, Б. Г., Андреева, И. С., Olkin, S. E., Константиновна, Р. И., An, S., Belan, B. D., & Panchenko, M. V. (2010) · Wiley eBooks · doi:10.1002/9783527630134.ch14 · Cited by 8
Φλώρου, Ζ. (2020) · doi:10.12681/eadd/48166 · Cited by 8
The Impact of Vocalization Loudness on COVID-19 Transmission in Indoor SpacesPreprint
Barreda, S., Asadi, S., Cappa, C. D., Wexler, A. S., Bouvier, N. M., & Ristenpart, W. D. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2009.04060 · Cited by 8
Mukherjee, D., & Wadhwa, G. (2022) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2022.115485 · Cited by 7
Wang, Y.-Y., Chen, K., Wen, Z., & Jiang, Z. (2024) · Environmental and Sustainability Indicators · doi:10.1016/j.indic.2024.100424 · Cited by 7
Jiang, C., Liu, Z., Wang, Y., Yao, G., He, J., Li, S., Rong, R., Liang, Z., Chu, J., & Liu, J. (2024) · Sustainable Cities and Society · doi:10.1016/j.scs.2024.106003 · Cited by 7
Li, T., Katz, A. S., Osei-Twum, J.-A., James, L., Leung, V., Bozek, P. R., Persaud, N., O'Campo, P. J., & Siegel, J. A. (2025) · Journal of Infection and Public Health · doi:10.1016/j.jiph.2024.102650 · Cited by 7
Xu, J., Zhai, H., So, L. K., Wang, C., & Guo, H. (2025) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2025.138446 · Cited by 7
Global Epidemiology of Tuberculosis: Past, Present and Future
Ejeta, E., Legesse, M., Ameni, G., & Hallur, R. L. S. (2013) · Science Technology and Arts Research Journal · doi:10.4314/star.v2i2.98895 · Cited by 7
“People with prolonged, frequent, or intense contact with patient are at particularly high risk of becoming infected, with an estimated infection rate of 22% (Nicas et al., 2005, CDC, 2005, and Waddington, 2004).”
BackgroundFrequency of Smear-Negative Tuberculosis in Northwest Iran.
Pourostadi, M., Rashedi, J., Poor, B. M., Kafil, H. S., Hariri-Akbari, M., & Asgharzadeh, M. (2018) · PubMed Central · Cited by 7
Raghava, N., & Vidovic, B. (2021) · International Journal of Dentistry and Oral Health · doi:10.16966/2378-7090.362 · Cited by 7
Fouqueau, A., Pourchez, J., Leclerc, L., Peyron, A., Montigaud, Y., Verhoeven, P. O., Macé, T., Bescond, A., Thomas, D., Charvet, A., et al. (2023) · Aerosol and Air Quality Research · doi:10.4209/aaqr.220252 · Cited by 8
“These activities can generate both sub-and supermicron particles (Nicas et al. , 2005).”
Zhang, T., Wei, G., & Liu, S. (2023) · Applied Sciences · doi:10.3390/app13137400 · Cited by 7
Gao, W., Xie, X., Liu, Y., Chen, X., & Zhu, C. (2024) · Powder Technology · doi:10.1016/j.powtec.2024.119543 · Cited by 7
Wang, Y., Liu, Z., Liu, H., Xiao, X., He, J., Li, S., & Liang, Z. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111761 · Cited by 7
Nawaz, R., Long, N. M. A. N., & Shohaimi, S. (2024) · Malaysian Journal of Mathematical Sciences · doi:10.47836/mjms.18.4.14 · Cited by 7
Umar, S., Munir, M., Kaboudi, K., Rehman, A., Asif, S., Usman, M., Ali, A., Shahzad, M. K., Subhan, S., & Shah, M. A. A. (2016) · British Poultry Science · doi:10.1080/00071668.2016.1174979 · Cited by 7
“Aerosols can stay in the air longer and travel farther than large droplets and hence are more likely to be responsible for airborne transmission of viruses (Nicas et al., 2005).”
BackgroundModeling Transport of SARS-CoV-2 Inside a Charlotte Area Transit System (CATS) Bus
Goodson, M., Feaster, J., Jones, A., McGowan, G. Z., Agricola, L., Timms, W., & Uddin, M. (2022) · Fluids · doi:10.3390/fluids7020080 · Cited by 7
Narayan, R., Kundu, D., Ghatak, A., Tripathi, S., & Datta, S. (2022) · Journal of Hospital Infection · doi:10.1016/j.jhin.2022.07.021 · Cited by 7
“These droplets initially are about 10 e 100 m m in diameter but dry rapidly depending on the relative humidity of the ambient air to form droplet nuclei (1 e 4 m m) containing micro-organisms [3].”
Mizukoshi, A., Okumura, J., & Azuma, K. (2023) · Risk Analysis · doi:10.1111/risa.14249 · Cited by 7
“Half of the initial diameter was used as the equilibrium size by Nicas et al. (2005), one third by Netz and Eaton (2020), and 30% by Wang, Alipour et al. (2021) and Henriques et al. (2022).”
BackgroundMethodInfluentialLi, Z., Ma, X., & Liao, Y. (2024) · Indoor and Built Environment · doi:10.1177/1420326x231224360 · Cited by 7
“31,49 The surface temperature of the human body was set to 305 K, with all other walls assumed to be adiabatic.”
BackgroundJiang, C., Liu, Z., Xiao, X., Liu, H., He, J., Rong, R., Liu, J., Huang, Z., & Wang, Y. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111263 · Cited by 7
Nichols, J. E., & LeDuc, J. W. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-369408-9.00027-5 · Cited by 7
Surgical Masks vs. N95 Respirator Masks for Protecting Health Care Professionals
Gupta, S. (2010) · The Indian Journal of Pediatrics · doi:10.1007/s12098-010-0264-1 · Cited by 7
“Transmission of this virus occurs by coughing or sneezing where infectious particles of various sizes, ranging from approximately 0.1– 100 μm, may be inhaled [ 1 ].”
BackgroundInfluentialAlonso, C. M., Olson, B. A., Goyal, S. M., Raynor, P. C., Davies, P. R., & Torremorell, M. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1249278 · Cited by 7
“In our study we did not assess the water content of our particles although we speculate that it is unlikely that the airborne particles became completely dry because of vapor pressure depression caused by dissolved materials in the fluids as shown by Nicas et al (2005).”
BackgroundAlzeer, J., & Al-Razem, F. (2021) · Journal of Public Health and Emergency · doi:10.21037/jphe-20-132 · Cited by 7
“number of particles exhaled per cough and sneeze is 5×10(3) and 1×10(6), respectively (14).”
BackgroundAl-Khamesy, K. S. A., Al-Shehari, M. M., Al-Moyed, K. A., Atf-allah, J. Y. Y., Al-Shamahy, H. A., & Al-Haddad, A. M. (2022) · Universal Journal of Pharmaceutical Research · doi:10.22270/ujpr.v7i5.833 · Cited by 7
Palmore, T. N., & Sepkowitz, K. A. (2011) · Wiley eBooks · doi:10.1002/0471435139.hyg111 · Cited by 7
Transmission of influenza A in human beings – Authors' reply
Gardam, M. A., & Lemieux, C. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70271-2 · Cited by 7
On the Formation and Physical Behaviour of Exhaled Particles
Holmgren, H. (2011) · Chalmers Publication Library (Chalmers University of Technology) · Cited by 7
Review of the Role of Aerosols in the Spread of COVID-19
Srivastava, N. (2024) · Springer eBooks · doi:10.1007/978-3-031-55836-8_10 · Cited by 6
Gür, M., & Kılıç, M. (2024) · Applied Sciences · doi:10.3390/app14188362 · Cited by 6
“…of a particle was 4182 J/kgK. Measured numbers of human expired particles during different respiratory activities vary between subjects, with the numbers roughly varying between 1000 and 10,000 for vocalizing, coughing, and breathing, although the numbers could rise up to 350,000 for sneezing [45].”
Cough airflow dynamics and droplet transmission: Methods, characteristics, and implications
Xiao, L., Li, K., Wei, J., Cao, Z., Cheng, Y., & Gao, N. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112974 · Cited by 6
Schutzer-Weissmann, J. M., Magee, D. J., & Farquhar-Smith, P. W. (2020) · Anaesthesia · doi:10.1111/anae.15221 · Cited by 6
“Modelling studies confirm that the risk of airborne transmission depends upon cough frequency [48].”
BackgroundInfection risk in cable cars and other enclosed spaces
Lunati, I., & Mucignat, C. (2022) · Indoor Air · doi:10.1111/ina.13094 · Cited by 6
Respiratory Virus Deposition and Resuspension from Indoor Surfaces
Rawat, M. S., & Ferro, A. R. (2022) · Springer eBooks · doi:10.1007/978-981-19-1356-3_7 · Cited by 6
Air Quality Improvement in COVID-19 Pandemic: Numerical Study of ventilation system in a classroom
Yatim, A. S., & Wijaya, E. P. (2023) · CFD letters · doi:10.37934/cfdl.15.1.2638 · Cited by 6
Estimated relative potential for airborne SARS-CoV-2 transmission in a day care centre
Kulmala, I. K., Taipale, A., Sanmark, E., Lastovets, N., Sormunen, P., Nuorti, P., Saari, S. E., Luoto, A., & Säämänen, A. J. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e30724 · Cited by 6
“Nicas and his fellow researchers [8] presented an airborne infection risk model that estimates the inhaled dose by taking into account the pathogen generation and removal mechanisms, and the alveolar deposition fraction of particles of different sizes.”
BackgroundNateghi, S., Kaczmarczyk, J., Zabłocka-Godlewska, E., & Przystaś, W. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112676 · Cited by 6
de Sá-Caputo, D. D. C., Coelho-Oliveira, A. C., Sonza, A., Paineiras-Domingos, L. L., Taïar, R., Das, S., Bello, A. R., & Bernardo-Filho, M. (2021) · Iranian Journal of Public Health · doi:10.18502/ijph.v50i12.7920 · Cited by 6
“Even more, some pathogens could be transmitted through the airborne route (5-8) and numerous droplets containing infectious particles (bacteria and virus) are released during coughing and sneezing (9,10).”
BackgroundGutmann, D., Donath, H., Herrlich, L., Lehmkühler, T., Landeis, A., Ume, E. R., Hutter, M., Goßmann, A., Weis, F., Weiß, M., et al. (2022) · Frontiers in Pediatrics · doi:10.3389/fped.2022.941785 · Cited by 6
“However, bigger “droplet nuclei” can also evaporate into multiple smaller particles (27, 28).”
BackgroundHabchi, C., Ghali, K., & Ghaddar, N. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.07.028 · Cited by 6
“It is well established that one of the main contributors to cross-contamination between occupants in indoor environments are high momentum respiratory activities as sneezing or coughing [5 e 7] which will be studied in the current work.”
Metadata
- Authors
- Nicas, M., Nazaroff, W. W., & Hubbard, A.
- Affiliations
- University of California, Berkeley (US)
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2005-03
- Volume
- 2
- Issue
- 3
- Pages
- 143-154
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- PMC
- PMC7196697
- OpenAlex
- W2160555964
- Cited by
- 867
- References
- 36
- Citations by year
- 2026: 23 · 2025: 55 · 2024: 56 · 2023: 75 · 2022: 100 · 2021: 149 · 2020: 93 · 2019: 12 · 2018: 22 · 2017: 17 · 2016: 20 · 2015: 25 · 2014: 21 · 2013: 34 · 2012: 24
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Centers for Disease Control and Prevention
- National Institute for Occupational Safety and Health
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Keywords
- airborne transmission, respiratory aerosols, respiratory pathogens, tuberculosis, cough, sneezing, particle size distribution, alveolar deposition, air disinfection, ventilation, superspreaders, infection risk, infectious dose, indoor air exposure
- MeSH terms
- Aerosols, Cough, Humans, Models, Theoretical, Particle Size, Pulmonary Alveoli, Risk Factors, Tuberculosis, Pulmonary, Risk Assessment, Inhalation Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.