Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Certain respiratory tract infections are transmitted through air. Coughing and sneezing by an infected person can emit pathogen-containing particles with diameters less than 10 microm that can reach the alveolar region. Based on our analysis of the sparse literature on respiratory aerosols, we estimated that emitted particles quickly decrease in diameter due to water loss to one-half the initial values, and that in one cough the volume in particles with initial diameters less than 20 microm is 60 x 10(-8) mL. The pathogen emission rate from a source case depends on the frequency of expiratory events, the respirable particle volume, and the pathogen concentration in respiratory fluid. Viable airborne pathogens are removed by exhaust ventilation, particle settling, die-off, and air disinfection methods; each removal mechanism can be assigned a first-order rate constant. The pathogen concentration in well-mixed room air depends on the emission rate, the size distribution of respirable particles carrying pathogens, and the removal rate constants. The particle settling rate and the alveolar deposition fraction depend on particle size. Given these inputs plus a susceptible person's breathing rate and exposure duration to room air, an expected alveolar dosemicrois estimated. If the infectious dose is one organism, as appears to be true for tuberculosis, infection risk is estimated by the expression: R = 1-exp(-micro). Using published tuberculosis data concerning cough frequency, bacilli concentration in respiratory fluid, and die-off rate, we illustrate the model via a plausible scenario for a person visiting the room of a pulmonary tuberculosis case. We suggest that patients termed "superspreaders" or "dangerous disseminators" are those infrequently encountered persons with high values of cough and/or sneeze frequency, elevated pathogen concentration in respiratory fluid, and/or increased respirable aerosol volume per expiratory event such that their pathogen emission rate is much higher than average.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Previous authors have noted that the viral load of human-emitted infectious aerosols may depend on sputum volume [31,42].”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atmospheric Chemistry and Physics: From Air Pollution to Climate Change
Seinfeld, J. H., Pandis, S. N., & Noone, K. (1998) · Physics Today · doi:10.1063/1.882420 · Cited by 8,731 · cited 3×
“However, if the infec-tious dose is 10 organisms, infection risk is only 1.1 × 10 −7 according to the above expression based on Equation 14 .”
BackgroundInfluentialGuideline for Isolation Precautions in Hospitals
Garner, J. S., & the Hospital Infection Control Practices Advisory Committee (1996) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700006123 · Cited by 994
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850 · cited 1×
“These studies were published by Duguid (15) in 1946, Louden and Roberts ( eq 4) in 1967, and Papineni and Rosenthal (16) in 1997.”
BackgroundThe size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 10×
“The Papineni and Rosenthal findings substantially differ from the data reported by Duguid and by Louden and Roberts (hereafter denoted L&R).”
BackgroundInfluential(2001) · Cited by 666
WELLS, W. F. (1934) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a118097 · Cited by 602 · cited 1×
“W.F. Wells (4) argued that droplets derived from respiratory fluid with d a < 100 µm rapidly evaporate to become droplet nuclei before they can be removed from air by gravitational settling.”
BackgroundDilution of Respiratory Solutes in Exhaled Condensates
EFFROS, R. M., HOAGLAND, K. W., BOSBOUS, M., CASTILLO, D., FOSS, B., DUNNING, M., GARE, M., LIN, W., & SUN, F. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2101018 · Cited by 386 · cited 2×
“The regression equation did not account for water loss from the larger particles prior to deposition onto bond paper,(13) and there was no adjustment for evaporative water loss from the smaller particles collected on the Millipore filter.”
BackgroundRiley, R. L., MILLS, C. C., O'Grady, F., SULTAN, L. U., Wittstadt, F. B., & Shivpuri, D. (1962) · PubMed · doi:10.1164/arrd.1962.85.4.511 · Cited by 313
Airborne Contagion and Air Hygiene
Phair, J. J. (1955) · American Journal of Public Health and the Nations Health · doi:10.2105/ajph.45.11.1495-c · Cited by 257
Murray, D. M., & Burmaster, D. E. (1995) · Risk Analysis · doi:10.1111/j.1539-6924.1995.tb00338.x · Cited by 250 · cited 1×
“5 ach is a typical residential air exchange rate.(31) Airborne M.”
Background
Research works printed but not linked: 6
- 4. Wells, W.F.: Onair-borne infection. Study II. Droplets and droplet nuclei. Am. J. Hyg. 20 :611-618 (1934).
- 5. Hinds, W.C.: Aerosol Technology . New York: John Wiley & Sons, Inc., 57-58:211-221 (1982).
- 7. Sonkin, L.S.: The role of particle size in experimental airborne infection. Am. J. Hyg. 53 :337-354 (1951).
- 21. Jennison, M.W.: Atomizing of mouth and nose secretions into the air as revealed by high-speed photography. In Aerobiology (Pub. No. 17). Washington, D.C.: American Association for the Advancement of Science, 1942. pp. 106-128.
- 33. Office of Research and Development: Exposure Factors Handbook (Draft). Washington, D.C.: U.S. Environmental Protection Agency, 1996. pp. 5-22.
- 36. Riley, R.L., C.C. Mills, F. O'Grady, L.U. Sultan, F. Wittstadt, and D.N. Shivpuri: Infectiousness of air from a tuberculosis ward. Am. Rev. Resp. Dis. 85 :511-525 (1962).
Cited by
Items 701–800 of 942
A hemophilic patient presented with an abdominal mass, fever and cough
Rahman, M. M., Khan, L., Islam, M. S., Islam, M. M., & Saha, D. (2018) · Bangabandhu Sheikh Mujib Medical University Journal · doi:10.3329/bsmmuj.v11i1.35585 · Cited by 2
A 65–year–old male with moderate anemia, low-grade fever and weight loss
Rahman, M. M., Islam, M. M., & Islam, M. S. (2020) · Bangabandhu Sheikh Mujib Medical University Journal · doi:10.3329/bsmmuj.v13i3.49254 · Cited by 2
Fernandez, K. B., Dalisay, J. D. E., & Berana, M. S. (2021) · Philippine Engineering Journal · Cited by 2
Sussman, R. A., Golberstein, E., & Polosa, R. (2022) · Environmental Science and Pollution Research · doi:10.1007/s11356-022-20499-1 · Cited by 2
“to provide a more meaningful context, our risk model incorporates into the risk model results 77 from Sussman et al. (2020) and BMS to evaluate viral quanta emissions, not only from vaping, 78 but also from speaking and coughing, all compared with respect to a control state of unavoidable 79 emissions from continuous…”
Faktor-faktor Determinan Perilaku Mencuci Tangan Setelah Masa ‘Adaptasi Kebiasaan Baru’
Widawati, M., Pradani, F. Y., Fuadiyah, M. E. A., Fuadzy, H., & Nurindra, R. W. (2022) · Buletin Penelitian Sistem Kesehatan · doi:10.22435/hsr.v25i1.4786 · Cited by 2
Investigating toothbrushing behavior and its aerosol emissions from using electric toothbrushes
Tang, W., Li, Y., Du, B., & Ye, W. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110594 · Cited by 2
Piller, M., Bulian, G., & Stival, C. A. (2023) · Journal of Building Performance Simulation · doi:10.1080/19401493.2023.2232341 · Cited by 2
“However, the shrinkage time from the original respiratory aerosols to particles is rapid (about 0.5 s), especially for particles whose size is smaller than 20 μm (Nicas, Nazaroff, and Hubbard 2005).”
BackgroundInfluentialWu, T. Y., Liu, Y., Lin, F.-H., Liu, Y., Liu, J., Jung, J., Yu, W. Z., Liu, Q., Shin, R. Y. C., & Teo, T. L. (2023) · Aerosol Science and Engineering · doi:10.1007/s41810-023-00190-9 · Cited by 2
Ji, S., Jones, R. M., & Lei, H. (2023) · Risk Analysis · doi:10.1111/risa.14227 · Cited by 2
“…and number distribution of respiratory aerosols during different respiratory activities, yet there has been limited research comparing these distributions since Nicas et al. (2005) described and compared the studies of Duguid (1946), Loudon and Roberts (1967), and Papineni and Rosenthal (1997).”
BackgroundNeisi, A., Farhadi, M., & Talepour, N. (2023) · Journal of Human Environment and Health Promotion · doi:10.61186/jhehp.9.3.113 · Cited by 2
Nieto–Chaupis, H. (2023) · International Conference on Electrical, Computer and Energy Technologies (ICECET) · doi:10.1109/icecet58911.2023.10389521 · Cited by 2
“At the end of first quarter 2020, it was confirmed that aerosols have been the main mechanism of infection of virus [5-6].”
BackgroundSun, Y., Francisco, P. W., Merrin, Z., & Gilleade, K. (2024) · Indoor Air · doi:10.1155/2024/6685891 · Cited by 2
Yan, Y., Hu, J., Zhong, K., & Jia, H. (2024) · Indoor and Built Environment · doi:10.1177/1420326x241266123 · Cited by 2
The effects of ventilation layout on cough droplet dynamics relating to seasonal influenza
Norvihoho, L. K., Yin, J. H., Zhu, X.-G., Xue, S.-Q., Yu, H.-T., & Zhou, Z. (2024) · Physics of Fluids · doi:10.1063/5.0237623 · Cited by 2
Nayak, S., Mayya, Y. S., & Tirumkudulu, M. S. (2024) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2024.106499 · Cited by 2
Soleimani-Alyar, S., Yarahmadi, R., Jebeli, M. B., Yarahmadi, G., Bokharaei‐Salim, F., Alipour, A., Soleimani-Alyar, M., Monavari, H., Darvishi, M.-M., & Dalvand, S. (2025) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2024.2447317 · Cited by 2
“Some of the larger respiratory droplets may undergo a size reduction following evap-oration and can remain suspended to the same extent (Nicas et al. 2005).”
InfluentialQing, Z., Zhang, W., Zhang, H., Zhang, H., & Xuan, Y. (2025) · Building Simulation · doi:10.1007/s12273-025-1239-5 · Cited by 2
“…and engineering studies have identified airborne transmission, propelled by virus-laden exhalations from infected individuals, as a primary route for spreading various infectious diseases (Nicas et al. 2005; Morawska et al. 2013; Ai et al. 2019; Villafruela et al. 2019; Liu et al. 2020).”
Yi, H., Kang, D. H., Choi, S. H., Park, S. R., Park, H. W., Mehrotra, A., Jang, S. J., Han, J., Yun, H., Park, K.-H., et al. (2025) · Architectural Science Review · doi:10.1080/00038628.2025.2493806 · Cited by 2
Onifade, A. A., Edem, V. F., & Arinola, O. G. (2018) · African Journal of Clinical and Experimental Microbiology · doi:10.4314/ajcem.v19i2.3 · Cited by 2
Effectiveness of Building Systems Strategies for Mitigation of Airborne Transmission of SARS-CoV-2
Kong, M., Shen, J., Dong, B., & Zhang, J. “. (2020) · Syracuse University Libraries (Syracuse University) · Cited by 2
Thanigaiarasu, S., Balamani, G., Bakiya, A., Immaculyne, F., Krishnamurthy, K., & Britto, R. L. J. D. (2022) · Mathematical Problems in Engineering · doi:10.1155/2022/6881712 · Cited by 2
“While some authors consider a size larger than 20 μm as droplets, others consider that only droplets larger than 60 μm can sustain and cause droplet infection [7, 21, 22].”
BackgroundManaging IAQ at Multiple Scales: From Urban to Personal Microenvironments
Zhang, J. “., Shen, J., & Gao, Z. J. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-16-7680-2_57 · Cited by 2
Modeling Tuberculosis in Lung and Central Nervous System
El-Kebir, M. (2010) · Centrum Wiskunde & Informatica (CWI), the national research institute for mathematics and computer science in the Netherlands · Cited by 2
Detection of bacteriophage and respiratory viruses in droplets
Perrott, P. (2011) · Cited by 2
Investigations into human influenza transmission
Killingley, B. (2013) · Nottingham ePrints (University of Nottingham) · Cited by 2
Herrera, V., & María, A. (2013) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 2
Avian influenza and co-infections : investigation of the interactions in the poultry models
Umar, S. (2017) · theses.fr (ABES) · doi:10.70675/b9bdf5c3zf622z46ddz8a52z1e719f27248c · Cited by 2
Celline, P. R. (2017) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.3.2017.tde-11072017-132626 · Cited by 2
Shahzadi, I., Shahzadi, A., Haider, J., Naz, S., Aamir, R. M., Haider, A., Sharif, H. R., Khan, I. M., & Ikram, M. (2020) · medRxiv · doi:10.1101/2020.07.14.20153544 · Cited by 2
“Both cough and 90 sneeze emit viral particles in the form of aerosol droplets where cough based particles having 91 diameter 20 μm quickly loss water and achieve diameter almost less than half of initial size 92 (Nicas et al., 2005).”
BackgroundFace-masks save us from SARS-CoV-2 transmissionPreprint
Bagheri, G., Thiede, B., Hejazi, B., Schlenczek, O., & Bodenschatz, E. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2106.00375 · Cited by 2
Schijven, J. F., Vermeulen, L. C., Swart, A., Meijer, A., Duizer, E., & Husman, A. M. D. R. (2021) · Environmental Health Perspectives · doi:10.1289/ehp10105 · Cited by 2
Palmore, T. N., & Sepkowitz, K. A. (2010) · Wiley eBooks · doi:10.1002/0471125326.hyg111 · Cited by 2
Development of a physiologically-relevant in vitro system to study exhaled bioaerosols
Hamed, R., Peters, T. M., Salem, A. K., Fiegel, J., Flanagan, D. R., & Donovan, M. D. (2011) · doi:10.17077/etd.dxj6ywhh · Cited by 2
OCCUPANT-ORIENTED INDOOR ENVIRONMENTAL CONTROLS IN PUBLIC SPACES
Wang, L. (2023) · University Libraries (University of Maryland) · doi:10.13016/dspace/e3dm-7hs8 · Cited by 2
Vishwakarma, A. K., & Sahu, S. (2024) · Physics of Fluids · doi:10.1063/5.0233820 · Cited by 1
Microdroplet Resuspension Off Surfaces
Wu, Y., Islam, K., Liu, Y., & Jagota, A. (2024) · Langmuir · doi:10.1021/acs.langmuir.4c02833 · Cited by 1
Ayuba, N., Justi, G. H., & Lopes, G. C. (2025) · Revista Principia - Divulgação Científica e Tecnológica do IFPB · doi:10.18265/2447-9187a2025id8833 · Cited by 1
Sankurantripati, S., Duchaine, F., Francois, N., Marshall, S., & Nekolny, P. (2025) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2025.106642 · Cited by 1
Bale, R., Murga, A., Yamamoto, H., & Tsubokura, M. (2025) · Sustainability · doi:10.3390/su17188193 · Cited by 1
Veeravalli, V. E., Blandfort, D., & Buckley, M. (2025) · Physics of Fluids · doi:10.1063/5.0286148 · Cited by 1
Risk of exposure to bioaerosols in clinical environments: Bronchoscopy
Gómez-Sánchez, N., Alcalde, L., Sancho-Chust, J. N., Boira, I., Gálvez, B., Esteban, V., Chiner, E., Yubero, E., Colom, M. F., & Ferrer, C. (2025) · American Journal of Infection Control · doi:10.1016/j.ajic.2025.11.026 · Cited by 1
The influence of glottal and respiratory factors on aerosol emission during phonation
Hilger, A., Stockman, T., Murphey, C., McCurdy, J., & Miller, S. L. (2025) · PLoS ONE · doi:10.1371/journal.pone.0321909 · Cited by 1
The Selective Detection of Individual Respiratory Droplets in Air
Malok, M., Kavšek, D., & Remškar, M. (2025) · ACS Sensors · doi:10.1021/acssensors.5c02057 · Cited by 1
“4,5 Although these droplets begin drying immediately after exhalation, their composition never allows them to dry out completely, 6 as evaporation is governed by multiple phenomena.”
Choi, H., An, S., & Hwang, J. (2026) · Indoor Air · doi:10.1155/ina/5923308 · Cited by 1
Role of hygroscopicity in indoor transmission of exhaled submicron particles
Li, Y., Ma, N., Wiedensohler, A., Guo, L., Xue, Z., Luo, B., Zhu, S., Yang, Z., Hong, J., Tao, J., et al. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114482 · Cited by 1
Idisi, I. O., Oshinubi, K., Omorogie, E. O., Jimoh, F. M., Audu, A. M., Iwa, L. L., & Okeowo, V. I. (2026) · Discover Public Health · doi:10.1186/s12982-026-01851-z · Cited by 1
Wang, Y., Jiang, L., Liu, Z., Cai, D., Liu, J., Rong, R., Li, S., Wu, W., & Cao, G. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114697 · Cited by 1
Liu, D., Zhao, J., Hussain, F., Wu, Y., Liu, J., Gao, F., Fan, Y., & Xu, D. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.115153 · Cited by 1
Detection of Bacteriophage in Droplets
Perrott, P., & Hargreaves, M. H. (2011) · InTech eBooks · doi:10.5772/29223 · Cited by 1
“…interested in the latter, as they are undeniably implicated in the spread of respiratory infections like RSV. Droplets evaporate very quickly once they are released (in the order of milliseconds), and their size decreases to approximately half the original size of the droplet (Nicas et al., 2005).”
InfluentialWood, A., & Wicklin, S. A. V. (2013) · AORN Journal · doi:10.1016/j.aorn.2013.02.008 · Cited by 1
Validation of a Human Exhalation Flow Simulation in a Room with Vertical Ventilation
Olmedo, I., Nielsen, P. V., & de Adana, M. R. (2012) · VBN Forskningsportal (Aalborg Universitet) · Cited by 1
Chair Fans as Energy Efficient Strategy to Aid Localized Ventilation
Habchi, C., Ghali, K., & Ghaddar, N. (2017) · Renewable Energy and Power Quality Journal · doi:10.24084/repqj14.453 · Cited by 1
Nicas, M. (2005) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.167291 · Cited by 1
“…industry respirator standard of the Occupational Safety and Health Administration (OSHA) permits estimating airborne chemical exposure via mathematical modeling in lieu of making direct measurements (OSHA,1998); similar exposure modeling can be applied to airborne pathogens (Nicas, et al., 2005).”
Self-citationNumerical Simulation of Aerosol Particles Distribution in a Classroom
Zhang, Y., Feng, G., Huang, K., & Cao, G. (2013) · Lecture notes in electrical engineering · doi:10.1007/978-3-642-39578-9_22 · Cited by 1
“Links in the Chain” of Disease Transmission
Dunowska, M. (2011) · Wiley eBooks · doi:10.1002/9781119266037.ch3 · Cited by 1
Price, D. N. (2016) · UNM’s Digital Repository (University of New Mexico) · Cited by 1
Aerosol transport by coughing in a depressurized and air-conditioned chamber
Zhang, B. (2017) · Cited by 1
FANA Global Consultancy and Business Limited, U., & Tahir, M. Z. (2018) · National Journal of Health Sciences · doi:10.21089/njhs.34.0132 · Cited by 1
“A person needs to inhale only a few of these germs to become infected [3].”
BackgroundХнувс, & України, К. А. (2019) · Kharkiv National University of Internal Affairs Institutional Repository (Kharkiv National Medical University) · Cited by 1
Miller, E. K. (2019) · UNM’s Digital Repository (University of New Mexico) · Cited by 1
The mask, the aerosol, and the pandemic: The good, the bad, and the ugly
Maheshwari, R. (2020) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_1964_20 · Cited by 1
“Aerosols are so small that buoyant forces overcome gravity, allowing them to stay suspended in the air for long periods, or they evaporate before they hit the floor, leaving the solid particulate (“droplet nuclei”) free to float very long distances, causing what we often refer to as “airborne” transmission.[1,3,4]”
BackgroundCOVID-19: Hava Yolu ile Bulaşıyor mu?
YILMAZ, G. R. (2020) · Flora the Journal of Infectious Diseases and Clinical Microbiology · doi:10.5578/flora.70500 · Cited by 1
Control de la fuente respiratoria mediante el uso de una mascarilla quirúrgica: un estudio in vitro
Patel, R. B., Skaria, S. D., Mansour, M. M., & Smaldone, G. C. (2021) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2021.1877068 · Cited by 1
“Los nebulizadores se eligieron con base en las caracter ısticas del aerosol reportado en humanos durante la respiraci on peri odica y la tos.([22,23]) Los aerosoles de res-”
BackgroundStatus: nosocomial transmission and prevention of SARS‐CoV‐2 in a Danish context
Calum, H., Sode, L. P., & Pedersen, M. (2021) · Apmis · doi:10.1111/apm.13160 · Cited by 1
Personal Protective Equipment for COVID-19: A Comprehensive Review
Das, D., Nag, S., Naskar, H., Acharya, S., Bakchi, S., Ali, S. S., Roy, R. B., Tudu, B., & Bandyopadhyay, R. (2021) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-030-72752-9_7 · Cited by 1
Fluid Dynamics and Numerical Simulation of Exhaled Droplets Containing Infectious Viruses
Han, J. (2022) · Security and Communication Networks · doi:10.1155/2022/6708401 · Cited by 1
“*ese particles are composed of various microorganisms [1].”
BackgroundRetractedNumerical analysis on temporal size change of expiratory droplets by considering component variation
Bu, Y., Ooka, R., Kikumoto, H., & Oh, W. (2022) · E3S Web of Conferences · doi:10.1051/e3sconf/202235604015 · Cited by 1
“In Scenario 1, the non-volatile part is composed of Na + and Cl - (density: 2200 kg/m 3 , molecular weight: 58.5 kg/kmol) [12].”
BackgroundInfluentialBahramian, A., & Ahmadi, G. (2023) · International Journal of Multiphase Flow · doi:10.1016/j.ijmultiphaseflow.2023.104422 · Cited by 1
RetractedSandhiya, L., Aggarwal, R., Senthilkumar, K., & Upadhayay, A. (2023) · Environmental Science Advances · doi:10.1039/d3va00016h · Cited by 1
Kado, M. J., Perttula, K., Noth, E. M., Moore, D., Nguyen, P. K., Perrino, C. T., Nicas, M., & Hammond, S. K. (2023) · Indoor Air · doi:10.1155/2023/7664472 · Cited by 1
“This assumption is based upon previous literature that suggested that some of the larger PM rapidly decrease in aerosol diameter due to water loss to create droplet nuclei and more PM 2 by count [7, 47].”
BackgroundMethodSelf-citationSensitivity analysis for calculating the risk of viral infection
Cammarata, A., & Cammarata, G. (2023) · International Journal of Fuzzy Logic and Intelligent Systems · doi:10.5391/ijfis.2023.23.4.448 · Cited by 1
Numerical Evaluation of Aerosol Propagation in Wind Instruments Using Computational Fluid Dynamics
Soubrié, T., Néchab, J., Viala, R., Creton, M., & Jousserand, M. (2024) · Air · doi:10.3390/air2030017 · Cited by 1
Inactivation of porcine reproductive and respiratory syndrome (PRRS) virus
Cutler, T. D. (2011) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/etd-180810-1566 · Cited by 1
“…of Coccidioides immitis (CDC 2009), Mycobacterium tuberculosis (de la Rua-Domenech 2006), Legionella spp. (Diedern 2007), smallpox virus (Feigel et al. 2006), and a variety of other pathogenic fungi, bacteria, and viruses (Douwes et al. 2007; Fransworth et al. 2006; Nicas et al. 2005; Stärk 1999).”
BackgroundInfluentialThum, C. (2008) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 1
Burden of Influenza in Children
Silvennoinen, H. (2012) · UTUPub (University of Turku) · Cited by 1
The Use of Simulation Methods to Understand and Control Pandemic Influenza
Michael, B. (2012) · TSpace (University of Toronto) · Cited by 1
The building science of office surfaces: Implications for microbial community succession
Zare, M. (2015) · TSpace (University of Toronto) · Cited by 1
On the epidemiology, clinical presentation and transmission of respiratory viral infections
Sundell, N. (2020) · Gothenburg University Publications Electronic Archive (Gothenburg University) · Cited by 1
Control of particle dispersion from enclosed spaces
Kokkonen, A. (2018) · UEF eRepo (University of Eastern Finland) · Cited by 1
Sussman, R. A., Golberstein, E., & Polosa, R. (2021) · Research Square · doi:10.21203/rs.3.rs-340115/v1 · Cited by 1
Droplet and Particle Dynamics in Aerosol Reactors and Environmental System
Dhawan, S. (2021) · Open Scholarship Institutional Repository (Washington University in St. Louis) · doi:10.7936/cjqm-gb62 · Cited by 1
Detecting infectious and biological contaminants aboard aircraft - Is it feasible?
Hwang, G. M., DiCarlo, A. A., Teig, L. J., Lin, G., & Harkin, M. (2009) · IEEE Conference on Technologies for Homeland Security (HST) · doi:10.1109/ths.2009.5168076 · Cited by 1
Ali, A. R. I., Mohee, F. M., & Freire-Gormaly, M. (2024) · Research Square · doi:10.21203/rs.3.rs-3912531/v1 · Cited by 1
Pratt, A. (2022) · Iowa Research Online (The University of Iowa) · doi:10.25820/etd.007230 · Cited by 1
Clauß, M., & Clauß, M. (2020) · RePEc: Research Papers in Economics · doi:10.22004/ag.econ.301141 · Cited by 1
Essien, D. (2020) · Mspace (University of Manitoba) · Cited by 1
The Microbiological Efficiency of HEPA Filtration and Its Use in Medical Facilities
Laine, J. M. (2025) · Tampere University Institutional Repository (Tampere University) · Cited by 1
Portugal, B. (2014) · Americanae (AECID Library) · Cited by 1
Estimates of risk associated with a tuberculosis patient and air travel
Masago, Y., Jones, R. M., Bartrand, T. A., Haas, C. N., Nicas, M., & Rose, J. B. (2007)
Self-citationHaine, S. (2014) · Espace ÉTS (ETS)
Enviromental Infection Transmission: Routes of Transmission for Influenza and Other Agents
Spicknall, I. H. (2011) · Deep Blue (University of Michigan)
Sittmann, M. (2014) · SUNScholar (Stellenbosch University)
He, Q., Gao, N., Zhu, T., & Jia-zheng, W. (2010) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2010.5515154
“However, the diameters of exhaled droplets may span a wide range from O(1μm) to O(1000μm)[4].”
BackgroundSong, J.-X., Jang, J., Cho, Y., Jeong, W., Park, D. S., Jang, A., & Kwon, S.-B. (2013) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2013.11.008
Clynes, N. D., & Bitar, R. A. (2010)
Shakri, M. R. A., Zakaria, R. B., Samad, B. H. A., Yahya, K., Zin, R. M., Mustaffar, M., Majid, M. Z. A., & Tarekh, N. A. M. (2018) · Malaysian Journal of Civil Engineering · doi:10.11113/mjce.v23.15820
Predicting Transient Particle Transport In Enclosed Environments Based On Markov Chain
Chen, C., Lin, C., & Chen, Q. (2013) · Building Simulation Conference proceedings · doi:10.26868/25222708.2013.1202
Zhang, H. (2008) · SUNY Digital Repository Support (State University of New York System)
Borges, C. B. (2011) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Metadata
- Authors
- Nicas, M., Nazaroff, W. W., & Hubbard, A.
- Affiliations
- University of California, Berkeley (US)
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2005-03
- Volume
- 2
- Issue
- 3
- Pages
- 143-154
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- PMC
- PMC7196697
- OpenAlex
- W2160555964
- Cited by
- 867
- References
- 36
- Citations by year
- 2026: 23 · 2025: 55 · 2024: 56 · 2023: 75 · 2022: 100 · 2021: 149 · 2020: 93 · 2019: 12 · 2018: 22 · 2017: 17 · 2016: 20 · 2015: 25 · 2014: 21 · 2013: 34 · 2012: 24
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Centers for Disease Control and Prevention
- National Institute for Occupational Safety and Health
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Keywords
- airborne transmission, respiratory aerosols, respiratory pathogens, tuberculosis, cough, sneezing, particle size distribution, alveolar deposition, air disinfection, ventilation, superspreaders, infection risk, infectious dose, indoor air exposure
- MeSH terms
- Aerosols, Cough, Humans, Models, Theoretical, Particle Size, Pulmonary Alveoli, Risk Factors, Tuberculosis, Pulmonary, Risk Assessment, Inhalation Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.