Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Certain respiratory tract infections are transmitted through air. Coughing and sneezing by an infected person can emit pathogen-containing particles with diameters less than 10 microm that can reach the alveolar region. Based on our analysis of the sparse literature on respiratory aerosols, we estimated that emitted particles quickly decrease in diameter due to water loss to one-half the initial values, and that in one cough the volume in particles with initial diameters less than 20 microm is 60 x 10(-8) mL. The pathogen emission rate from a source case depends on the frequency of expiratory events, the respirable particle volume, and the pathogen concentration in respiratory fluid. Viable airborne pathogens are removed by exhaust ventilation, particle settling, die-off, and air disinfection methods; each removal mechanism can be assigned a first-order rate constant. The pathogen concentration in well-mixed room air depends on the emission rate, the size distribution of respirable particles carrying pathogens, and the removal rate constants. The particle settling rate and the alveolar deposition fraction depend on particle size. Given these inputs plus a susceptible person's breathing rate and exposure duration to room air, an expected alveolar dosemicrois estimated. If the infectious dose is one organism, as appears to be true for tuberculosis, infection risk is estimated by the expression: R = 1-exp(-micro). Using published tuberculosis data concerning cough frequency, bacilli concentration in respiratory fluid, and die-off rate, we illustrate the model via a plausible scenario for a person visiting the room of a pulmonary tuberculosis case. We suggest that patients termed "superspreaders" or "dangerous disseminators" are those infrequently encountered persons with high values of cough and/or sneeze frequency, elevated pathogen concentration in respiratory fluid, and/or increased respirable aerosol volume per expiratory event such that their pathogen emission rate is much higher than average.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Previous authors have noted that the viral load of human-emitted infectious aerosols may depend on sputum volume [31,42].”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atmospheric Chemistry and Physics: From Air Pollution to Climate Change
Seinfeld, J. H., Pandis, S. N., & Noone, K. (1998) · Physics Today · doi:10.1063/1.882420 · Cited by 8,731 · cited 3×
“However, if the infec-tious dose is 10 organisms, infection risk is only 1.1 × 10 −7 according to the above expression based on Equation 14 .”
BackgroundInfluentialGuideline for Isolation Precautions in Hospitals
Garner, J. S., & the Hospital Infection Control Practices Advisory Committee (1996) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700006123 · Cited by 994
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850 · cited 1×
“These studies were published by Duguid (15) in 1946, Louden and Roberts ( eq 4) in 1967, and Papineni and Rosenthal (16) in 1997.”
BackgroundThe size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 10×
“The Papineni and Rosenthal findings substantially differ from the data reported by Duguid and by Louden and Roberts (hereafter denoted L&R).”
BackgroundInfluential(2001) · Cited by 666
WELLS, W. F. (1934) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a118097 · Cited by 602 · cited 1×
“W.F. Wells (4) argued that droplets derived from respiratory fluid with d a < 100 µm rapidly evaporate to become droplet nuclei before they can be removed from air by gravitational settling.”
BackgroundDilution of Respiratory Solutes in Exhaled Condensates
EFFROS, R. M., HOAGLAND, K. W., BOSBOUS, M., CASTILLO, D., FOSS, B., DUNNING, M., GARE, M., LIN, W., & SUN, F. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2101018 · Cited by 386 · cited 2×
“The regression equation did not account for water loss from the larger particles prior to deposition onto bond paper,(13) and there was no adjustment for evaporative water loss from the smaller particles collected on the Millipore filter.”
BackgroundRiley, R. L., MILLS, C. C., O'Grady, F., SULTAN, L. U., Wittstadt, F. B., & Shivpuri, D. (1962) · PubMed · doi:10.1164/arrd.1962.85.4.511 · Cited by 313
Airborne Contagion and Air Hygiene
Phair, J. J. (1955) · American Journal of Public Health and the Nations Health · doi:10.2105/ajph.45.11.1495-c · Cited by 257
Murray, D. M., & Burmaster, D. E. (1995) · Risk Analysis · doi:10.1111/j.1539-6924.1995.tb00338.x · Cited by 250 · cited 1×
“5 ach is a typical residential air exchange rate.(31) Airborne M.”
Background
Research works printed but not linked: 6
- 4. Wells, W.F.: Onair-borne infection. Study II. Droplets and droplet nuclei. Am. J. Hyg. 20 :611-618 (1934).
- 5. Hinds, W.C.: Aerosol Technology . New York: John Wiley & Sons, Inc., 57-58:211-221 (1982).
- 7. Sonkin, L.S.: The role of particle size in experimental airborne infection. Am. J. Hyg. 53 :337-354 (1951).
- 21. Jennison, M.W.: Atomizing of mouth and nose secretions into the air as revealed by high-speed photography. In Aerobiology (Pub. No. 17). Washington, D.C.: American Association for the Advancement of Science, 1942. pp. 106-128.
- 33. Office of Research and Development: Exposure Factors Handbook (Draft). Washington, D.C.: U.S. Environmental Protection Agency, 1996. pp. 5-22.
- 36. Riley, R.L., C.C. Mills, F. O'Grady, L.U. Sultan, F. Wittstadt, and D.N. Shivpuri: Infectiousness of air from a tuberculosis ward. Am. Rev. Resp. Dis. 85 :511-525 (1962).
Cited by
Items 301–400 of 942
Liu, H., Liu, Z., He, J., Hu, C., Rong, R., Han, H., Wang, L., & Wang, D. (2023) · Environmental Research · doi:10.1016/j.envres.2023.116952 · Cited by 33
Wurie, F. B., de Waroux, O. L. P., Brande, M., DeHaan, W. H., Holdgate, K., Mannan, R., Milton, D. K., Swerdlow, D. I., & Hayward, A. C. (2013) · F1000Research · doi:10.12688/f1000research.2-14.v1 · Cited by 33
Lai, A. C. K., Nunayon, S. S., Tan, T. F., & Li, W. S. (2018) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2018.07.003 · Cited by 33
“Primary pathway infection occurs by direct inhalation of pathogenic airborne droplets [14] [15] [16] .”
BackgroundMirbod, P., Haffner, E., Bagheri, M., & Higham, J. (2021) · Journal of The Royal Society Interface · doi:10.1098/rsif.2020.0967 · Cited by 33
Perimeter leakage of face masks and its effect on the mask's efficacy
Solano, T., Ni, C., Mittal, R., & Shoele, K. (2022) · Physics of Fluids · doi:10.1063/5.0086320 · Cited by 33
Dubler, S., Zimmermann, S., Fischer, M., Schnitzler, P., Bruckner, T., Weigand, M. A., Frank, U., Hofer, S., & Heininger, A. (2016) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.12768 · Cited by 33
Multiscale Airborne Infectious Disease Transmission
Dillon, C. F., & Dillon, M. B. (2020) · Applied and Environmental Microbiology · doi:10.1128/aem.02314-20 · Cited by 33
“In the medical context, near-range airborne disease spread (,5 m) is common and occurs when infected individuals generate large quantities of infectious droplet particles (and droplet nuclei) when coughing or sneezing (8, 9).”
BackgroundA tool to model the Fate and Transport of Indoor Microbiological Aerosols (FaTIMA)
Dols, W. S., Polidoro, B. J., Poppendieck, D. G., & Emmerich, S. J. (2020) · doi:10.6028/nist.tn.2095 · Cited by 33
“These bioeffluents include aqueous droplets on the order of 10 μm or larger and smaller droplet nuclei often considered to be about 5 μm or less in diameter [19].”
BackgroundHeuer, J. F., Crozier, T. A., Howard, G., & Quintel, M. (2013) · PubMed Central · doi:10.3205/dgkh000209 · Cited by 32
“Themain transmissionmode for the influenza virus is via aerosols that can remain airborne for more than 60 minutes because of their low settling velocity [8], [9].”
BackgroundComparison of COVID-19 infection risks through aerosol transmission in supermarkets and small shops
Li, C., & Tang, H. (2021) · Sustainable Cities and Society · doi:10.1016/j.scs.2021.103424 · Cited by 32
Song, Y., Lee, Y.-K., Lee, Y., Hwang, W., Lee, J., Park, S., Park, N., Song, H., Kim, H., Lee, K. G., et al. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.144224 · Cited by 32
Engineering control of respiratory infection and low-energy design of healthcare facilities
Li, Y., Tang, J. W.-T., Noakes, C. J., & Hodgson, M. J. (2014) · Science and Technology for the Built Environment · doi:10.1080/10789669.2014.965557 · Cited by 33
Leung, W. T., Sze-To, G. N., Chao, C. Y. H., Yu, S. C. T., & Kwan, J. K. C. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00797.x · Cited by 32
“…were added to distilled water to prepare 1 l of simulated human respiratory fluid with E. coli concentrations of between 1 · 105 and 106 CFU/ml. Glycerol was added to the artificial saliva solution to represent the non-volatile materials in the saliva (Nicas et al., 2005; Chao and Wan, 2006).”
Habchi, C., Ghali, K., & Ghaddar, N. (2014) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2014.05.009 · Cited by 32
Modeling unsteady filtration performance of pleated filter
Feng, Z., & Long, Z. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1172058 · Cited by 31
“Airborne particles can carry viruses and other microorganisms that cause a variety of health problems (Mangili and Gendreau 2005; Nicas et al. 2005; Morawska 2006).”
BackgroundRemington, W. D., Ott, B. C., & Hartka, T. R. (2021) · The Journal of the American Dental Association · doi:10.1016/j.adaj.2021.08.011 · Cited by 31
“We recognize that particles smaller than 10 mm are capable of reaching lower parts of the airway system and are therefore more likely to be involved in disease transmission.(12,13) Methods of filtering particulates out of the air have been examined previously in the dental setting.”
BackgroundPan, S., Xu, C., Yu, C. W., & Liu, L. (2022) · Indoor and Built Environment · doi:10.1177/1420326x221110975 · Cited by 31
“15,28,50,51 So to reduce the evaporation of droplets before entering the APS, the funnel was directly connected to the APS.”
BackgroundSurface rheological properties alter aerosol formation from mucus mimetic surfaces
Hamed, R., Schenck, D. M., & Fiegel, J. (2020) · Soft Matter · doi:10.1039/d0sm01232g · Cited by 31
van Beest, M., Arpino, F., Hlinka, O., Sauret, E., van Beest, N., Humphries, R. S., Buonanno, G., Morawska, L., Governatori, G., & Motta, N. (2022) · Atmospheric Pollution Research · doi:10.1016/j.apr.2022.101473 · Cited by 31
Liu, Z., Ma, J., Lv, J., Wang, Y., He, J., Yao, G., & Cao, G. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.130650 · Cited by 30
Magnitude of initial default in pulmonary tuberculosis.
Rao, N. A., Anwer, T., & Saleem, M. (2009) · PubMed · Cited by 30
The Infectious Dose of Variola (Smallpox) Virus
Nicas, M., Hubbard, A., Jones, R. M., & Reingold, A. L. (2004) · Applied Biosafety · doi:10.1177/153567600400900302 · Cited by 30
Self-citationBarbosa, B. P. P., & Brum, N. D. C. L. (2021) · Journal of the Brazilian Society of Mechanical Sciences and Engineering · doi:10.1007/s40430-021-03029-x · Cited by 29
Habchi, C., Ghali, K., Ghaddar, N., & Shihadeh, A. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.10.019 · Cited by 29
Dontwi, I. K., Obeng–Denteh, W., & Andam, E. A. (2014) · British Journal of Mathematics & Computer Science · doi:10.9734/bjmcs/2014/4681 · Cited by 29
“Each one of these droplets may transmit the disease, since the infectious dose of tuberculosis is very low, the inhalation of fewer than 10 bacteria may cause an infection [6].”
BackgroundSobolik, J. S., Sajewski, E. T., Jaykus, L., Cooper, D. K., Lopman, B. A., Kraay, A. N. M., Ryan, P. B., Guest, J. L., Girard, A. W., & León, J. S. (2021) · Food Control · doi:10.1016/j.foodcont.2022.108845 · Cited by 28
Salinas, J. S., Krishnaprasad, K. A., Zgheib, N., & Balachandar, S. (2022) · Physical Review Fluids · doi:10.1103/physrevfluids.7.064309 · Cited by 28
A CFD-based framework to assess airborne infection risk in buildings
Vita, G., Woolf, D., Avery-Hickmott, T., & Rowsell, R. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110099 · Cited by 28
“In order to calculate the intake fraction, a calculation of the respiratory volume at the emission source is needed so that the correct infectious dose emitted, as measured and reported in literature, is calculated [11,60].”
Quantifying the size-resolved dynamics of indoor bioaerosol transport and control
Kunkel, S. A., Azimi, P., Zhao, H., Stark, B. C., & Stephens, B. (2017) · Indoor Air · doi:10.1111/ina.12374 · Cited by 28
“Given that the mass fraction of nonvolatile components is approximately 1%, the fully desiccated particle diameter would be expected to be only ~22% of the original emitted particle diameter.(9) This suggests that most of the mass of TABLE 1 Specific qPCR primers used in this study”
BackgroundBekking, C., Yip, L., Groulx, N., Doggett, N., Finn, M., & Mubareka, S. (2019) · Influenza and Other Respiratory Viruses · doi:10.1111/irv.12678 · Cited by 28
“[3] [4] [5] [6] Lower respiratory tract infection is associated with increased disease severity and mortality compared to infection of the upper respiratory tract.”
BackgroundAirborne Transmission of Influenza Virus in a Hospital of Qinhuangdao During 2017–2018 Flu Season
Zhao, X., Nie, W., Zhou, C., Cheng, M., Wang, C., Liu, Y., Li, J., Qian, Y., Ma, X., Zhang, L., et al. (2019) · Food and Environmental Virology · doi:10.1007/s12560-019-09404-1 · Cited by 28
Tuttle, R. S., Sosna, W. A., Daniels, D. E., Hamilton, S. B., & Lednicky, J. A. (2010) · Virology Journal · doi:10.1186/1743-422x-7-135 · Cited by 28
“First, it is important to distinguish between the initial diameter of particles and the diameter after evaporation of water in ambient air [the resulting desiccated particles are termed 'droplet nuclei'; for particles with an initial diameter <20 μm the evaporation occurs in <1 s [26,27] and the diameter shrinks to a…”
BackgroundDegois, J., Veillette, M., Poulin, P., Lévesque, B., Aubin, D., Ouazia, B., Brisson, M., Maltais, F., & Duchaine, C. (2021) · Indoor Air · doi:10.1111/ina.12857 · Cited by 27
Pairetti, C. I., Villiers, R., & Zaleski, S. (2021) · Computers & Fluids · doi:10.1016/j.compfluid.2021.105125 · Cited by 27
Numerical evaluation of face masks for prevention of COVID-19 airborne transmission
Liu, J., Hao, M., Chen, S., Yang, Y., Li, J., Mei, Q., Bian, X., & Liu, K. (2022) · Environmental Science and Pollution Research · doi:10.1007/s11356-022-18587-3 · Cited by 27
Indian Guidelines on Nebulization Therapy
Katiyar, S. K., Gaur, S. N., Solanki, R., Sarangdhar, N., Suri, J. C., Kumar, R., Khilnani, G., Chaudhary, D., Singla, R., Koul, P. A., et al. (2022) · Indian Journal of Tuberculosis · doi:10.1016/j.ijtb.2022.06.004 · Cited by 27
Yoo, S., Kurokawa, A., Matsunaga, K., & Ito, K. (2023) · Experimental and Computational Multiphase Flow · doi:10.1007/s42757-022-0146-6 · Cited by 27
“8%), assuming a saliva/phlegm droplet (Nicas et al., 2005).”
BackgroundInfluentialDispersion of expectorated cough droplets with seasonal influenza in an office
Norvihoho, L. K., Li, H., Zhou, Z., Yin, J. H., Chen, S.-Y., Zhu, D.-Q., & Chen, B. (2023) · Physics of Fluids · doi:10.1063/5.0160579 · Cited by 27
Chen, C., Zhu, J., Qu, Z., Lin, C., Jiang, Z. L., & Chen, Q. (2013) · Science and Technology for the Built Environment · doi:10.1080/10789669.2013.834778 · Cited by 27
“Exhalation activities, such as breathing, coughing, talking, and sneezing, by an infected person can generate pathogen-carrying particles (Nicas et al. 2005).”
BackgroundGuan, J., Fu, Q., Chan, M. K. H., & Spencer, J. L. (2013) · Avian Diseases · doi:10.1637/10486-010913-reg.1 · Cited by 27
“Viruses may be transported in the air with aerosols (particles less than 5 mm in size) or in large droplets (6).”
BackgroundInfluenza Infection Risk and Predominate Exposure Route: Uncertainty Analysis
Jones, R. M., & Adida, E. (2011) · Risk Analysis · doi:10.1111/j.1539-6924.2011.01600.x · Cited by 27
“(20,32−34) Nicas et al.(22) estimated 0.”
BackgroundInfluentialJohnson, G. R., Knibbs, L. D., Kidd, T. J., Wainwright, C. E., Wood, M., Ramsay, K. A., Bell, S. C., & Morawska, L. (2016) · PLoS ONE · doi:10.1371/journal.pone.0158763 · Cited by 27
“This equilibrium size depends on both the dry volume of any non-volatile material in the DN, and the amount of water retained by that material after evaporative equilibrium is established [17].”
BackgroundHu, N., Feng, Y., Gram, A., Yao, R., & Sadrizadeh, S. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110994 · Cited by 26
Pan, Y., Xia, T., Guo, K., An, Y., & Chen, C. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109792 · Cited by 26
Norvihoho, L. K., Yin, J. H., Zhou, Z., Han, J., Chen, B., Fan, L., & Lichtfouse, É. (2023) · Environmental Chemistry Letters · doi:10.1007/s10311-023-01579-1 · Cited by 26
Liu, Z., Han, Z., Hu, L., Hu, C., & Rong, R. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.111065 · Cited by 26
Xu, J., Fu, S. C., & Chao, C. Y. H. (2020) · Indoor and Built Environment · doi:10.1177/1420326x20951245 · Cited by 26
“The numerous pathogenladen droplets that are released from human respiratory activities, such as coughing, sneezing, talking and breathing, are the major source of airborne disease transmission.(4,5) Since people spend most of their time indoors; if the ventilation system of an indoor environment is poorly designed or…”
BackgroundPerformance comparison of heat recovery systems to reduce viral contagion in indoor environments
Schibuola, L., & Tambani, C. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.116843 · Cited by 26
“The majority of these droplets evaporates and it is quickly reduced to half of their initial size [3].”
BackgroundInvestigation on the evaporation and dispersion of human respiratory droplets with COVID-19 virus
Yin, J. H., Norvihoho, L. K., Zhou, Z., Chen, B., & Wu, W. (2021) · International Journal of Multiphase Flow · doi:10.1016/j.ijmultiphaseflow.2021.103904 · Cited by 26
“However, the droplet evaporation is of vital importance in the eventual fate of a droplet (Nicas et al., 2005; Wells, 1934), especially for medium size droplets (e.”
Shen, Y., Courtney, J. M., Anfinrud, P., & Bax, A. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2203086119 · Cited by 26
Yousefimashouf, M., Yousefimashouf, R., Alikhani, M. S., Hashemi, H., Karami, P., Rahimi, Z., & Hosseini, S. M. (2022) · New Microbes and New Infections · doi:10.1016/j.nmni.2023.101090 · Cited by 26
“Despite all these research fi ndings, the global community did not take the aerial transmission of diseases seriously until the acute respiratory syndrome occurred in 2003 and the human swine fl u in 2009 [4, 5].”
Park, S., Mistrick, R. G., Sitzabee, W. E., & Rim, D. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.165454 · Cited by 25
de Sousa, N. R., Shen, L., Silcott, D. B., Call, C. J., & Rothfuchs, A. G. (2020) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxaa053 · Cited by 25
“Bioaerosols are produced during coughing or sneezing (Nicas et al., 2005; Yang et al., 2007; Fernstrom and Goldblatt, 2013) and at lower concentrations during talking or breathing (Diffey, 2011; Fernstrom and Goldblatt, 2013).”
BackgroundHow coronavirus survives for hours in aerosols
Chatterjee, S., Murallidharan, J. S., Agrawal, A., & Bhardwaj, R. (2021) · Physics of Fluids · doi:10.1063/5.0059908 · Cited by 25
Coldrick, S., Kelsey, A., Ivings, M. J., Foat, T. G., Parker, S. T., Noakes, C. J., Bennett, A., Rickard, H., & Moore, G. (2022) · Indoor Air · doi:10.1111/ina.13000 · Cited by 25
“Source and number (1) Speakinga (2) Modified speakingb (3) Singingc (4) Modified singingd (5) Coughinge”
BackgroundHow do temperature, humidity, and air saturation state affect the COVID-19 transmission risk?
Mao, N., Zhang, D., Li, Y., Li, Y., Li, J. H., Zhao, L., Wang, Q., Zhu, C., Zhang, Y., & Long, E. (2022) · Environmental Science and Pollution Research · doi:10.1007/s11356-022-21766-x · Cited by 26
Classroom aerosol dispersion: desk spacing and divider impacts
Dacunto, P. J., Moser, D. H., Ng, A., & Benson, M. J. (2021) · International Journal of Environmental Science and Technology · doi:10.1007/s13762-021-03564-z · Cited by 24
Liang, Z., Chan, W. L., Tian, X., Lai, A. C. K., Lee, P. K. H., & Chan, C. K. (2022) · Atmospheric Environment · doi:10.1016/j.atmosenv.2022.119066 · Cited by 24
Wang, J., Wu, Z., Wang, H., Zhong, M., Mao, Y., Li, Y., Wang, M., & Yao, S. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.129697 · Cited by 24
“assessed as those after evaporation because evaporation could be ignored for droplet-based aerosol particles at the measured scales (Shao et al., 2021; Narayanan and Yang, 2021; Nicas et al., 2005); (3).”
Transient transmission of droplets and aerosols in a ventilation system with ceiling fans
Li, W., Hasama, T., Chong, A., Hang, J. G., Lasternas, B., Lam, K. P., & Tham, K. W. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.109988 · Cited by 24
Jiang, C., Liu, Z., Wang, Y., Yao, G., Li, S., Rong, R., Liang, Z., Liu, H., Liu, J., Wan, T., et al. (2024) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2024.141796 · Cited by 24
The influenza virus, SARS-CoV-2, and the airways: Clarification for the otorhinolaryngologist
de Gabory, L. L. T., Alharbi, A., Kerimian, M., & Lafon, M. (2020) · European Annals of Otorhinolaryngology Head and Neck Diseases · doi:10.1016/j.anorl.2020.05.015 · Cited by 24
Zhan, J., Liu, Q. S., Sun, Z., Zhou, Q., Hu, L., Qu, G., Zhang, J., Zhao, B., & Jiang, G. (2020) · Environmental Pollution · doi:10.1016/j.envpol.2020.115621 · Cited by 25
“Additionally, humidity can alter the dynamics of virusladen droplets by influencing their evaporation speed and droplet size, resulting in disturbed transmission distance (Nicas et al., 2005).”
Benchmarking of a Markov Multizone Model of Contaminant Transport
Jones, R. M., & Nicas, M. (2014) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meu055 · Cited by 24
“, 2008), or through coughs and sneezes (Nicas et al., 2005).”
BackgroundSelf-citationAlotaibi, S., Chakroun, W. M., Habchi, C., Ghali, K., & Ghaddar, N. (2018) · Building Simulation · doi:10.1007/s12273-018-0437-9 · Cited by 24
“As infected people constitute one of the main sources of contaminated particles (Morawska 2006; Nicas et al. 2005; Fanger et al. 1988), controlling airflows in the micro-environment of the occupants could be an effective strategy for limiting contaminants spread.”
BackgroundHow effective are face coverings in reducing transmission of COVID-19?
Robinson, J. F., de Anda, I. R., Moore, F. J., Gregson, F. K. A., Reid, J. P., Husain, L., Sear, R. P., & Royall, C. P. (2022) · Aerosol Science and Technology · doi:10.1080/02786826.2022.2042467 · Cited by 23
Firle, C., Steinmetz, A., Stier, O., Stengel, D., & Ekkernkamp, A. (2022) · Scientific Reports · doi:10.1038/s41598-022-12529-2 · Cited by 24
Evaporation of Concentrated Polymer Solutions Is Insensitive to Relative Humidity
Huisman, M., Digard, P., Poon, W. C. K., & Titmuss, S. (2023) · Physical Review Letters · doi:10.1103/physrevlett.131.248102 · Cited by 23
Critical Review and Uncertainty Analysis of Factors Influencing Influenza Transmission
Jones, R. M. (2011) · Risk Analysis · doi:10.1111/j.1539-6924.2011.01598.x · Cited by 24
“Nicas et al.(50) favored the results of Loudon and Roberts (51) due to lack of information to support calculation of equilibrium diameters measured by Duguid,(53) and consistency of the Loudon and Roberts(51) distribution with observed streptococci emission(54) and photographically enumerated particle counts.”
BackgroundResultInfluentialVisone, M., Lanzetta, M., Lappa, M., Lanzaro, C., & Polizio, L. (2021) · Physics of Fluids · doi:10.1063/5.0059649 · Cited by 23
Probabilistic indoor transmission modeling for influenza (sub)type viruses
Chen, S., & Liao, C. (2009) · Journal of Infection · doi:10.1016/j.jinf.2009.09.015 · Cited by 23
“We adapted the concept based on Nicas et al.16 in order to estimate quantum for influenza virus (sub)types.”
BackgroundMethodFang, X. Z., Li, X., Yan, Y., Tao, Y., Chen, Z., & Yan, P. (2022) · Experimental and Computational Multiphase Flow · doi:10.1007/s42757-022-0142-x · Cited by 22
“Among these, risk assessment in relation to human exposure to infectious droplets play a vital role in the early stage of the disease transmission investigation (Nicas et al., 2005).”
BackgroundSemi-surrogate modelling of droplets evaporation process via XGBoost integrated CFD simulations
Yan, Y., Li, X., Sun, W., Fang, X. Z., He, F., & Tu, J. Y. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.164968 · Cited by 22
Güleç, F., & Atakan, B. (2021) · IEEE Transactions on Molecular Biological and Multi-Scale Communications · doi:10.1109/tmbmc.2021.3083723 · Cited by 22
Anand, S., Krishan, J., Bathula, S., & Mayya, Y. S. (2021) · Indoor Air · doi:10.1111/ina.12868 · Cited by 22
SARS-CoV-2 aerosol and droplets: an overview
Ranga, U. (2021) · VirusDisease · doi:10.1007/s13337-021-00660-z · Cited by 22
“Several studies found that aerosol particles constitute less than 1% of the total particles emitted in a single expiration event [6, 10, 12].”
BackgroundInfluentialNanomechanics and Morphology of Simulated Respiratory Particles
Groth, R., Niazi, S., Johnson, G. R., & Ristovski, Z. (2022) · Environmental Science & Technology · doi:10.1021/acs.est.2c01829 · Cited by 22
Modeling the Impacts of Physical Distancing and Other Exposure Determinants on Aerosol Transmission
Wagner, J., Sparks, T. L., Miller, S., Chen, W., Macher, J. M., & Waldman, J. M. (2021) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2021.1963445 · Cited by 21
“Supplemental model results were calculated for two special cases.”
BackgroundMethodInfluentialAssessment of the air disinfection effect of low-concentration ozone in a closed environment
Liu, Z., Xiao, X., Jiang, C., Wang, Y., & He, J. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110747 · Cited by 21
Zhao, C.-B., Wu, J.-Z., Wang, B.-F., Chang, T., Zhou, Q., & Chong, K. L. (2024) · Physics of Fluids · doi:10.1063/5.0191573 · Cited by 23
What sizes of droplets contribute to long-range airborne transmission?
Cheng, P., Jia, W., Liu, L., Yen, H., & Li, Y. (2024) · Indoor Environments · doi:10.1016/j.indenv.2024.100045 · Cited by 21
Umar, S., Delverdier, M. E., Delpont, M., Belkasmi, S. F. Z., Teillaud, A., Bleuart, C., Pardo, I., Houadfi, M. E., Guérin, J., & Ducatez, M. (2018) · Avian Pathology · doi:10.1080/03079457.2018.1449942 · Cited by 21
“One way to address the spread of respiratory pathogens in air droplets in experimental conditions is to inoculate birds by aerosol rather than intra-nasal or intra-tracheal route (Nicas et al., 2005; Guan et al., 2013, 2015).”
MethodRetractedAerosol generation during chest compression and defibrillation in a swine cardiac arrest model
Hsu, C. H., Tiba, M. H., Boehman, A. L., McCracken, B. M., Leander, D. C., Francalancia, S. C., Pickell, Z., Sanderson, T. H., Ward, K. R., & Neumar, R. W. (2020) · Resuscitation · doi:10.1016/j.resuscitation.2020.12.004 · Cited by 21
Tang, H., Pan, Z., & Li, C. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109067 · Cited by 21
Aerosol measurement identifies SARS-CoV 2 PCR positive adults compared with healthy controls
Gutmann, D., Scheuch, G., Lehmkühler, T., Herrlich, L., Landeis, A., Hutter, M., Stephan, C., Vehreschild, M. J. G. T., Khodamoradi, Y., Goßmann, A., et al. (2022) · Environmental Research · doi:10.1016/j.envres.2022.114417 · Cited by 22
“Nevertheless, while traveling through air, droplets might evaporate into smaller particles (Infection Prevention and Control of, 2014; Nicas et al., 2005).”
Carroll, G. T., Kirschman, D. L., & Mammana, A. (2022) · Patient Safety in Surgery · doi:10.1186/s13037-022-00343-8 · Cited by 21
Localized air-conditioning with upper-room UVGI to reduce airborne bacteria cross-infection
Kanaan, M., Ghaddar, N., & Ghali, K. (2015) · Building Simulation · doi:10.1007/s12273-015-0250-7 · Cited by 21
“However, the study of Nicas et al. (2005) showed that an exhaled droplet larger than 20 μm cannot become a “droplet nucleus”.”
BackgroundYin, S., Sze-To, G. N., & Chao, C. Y. H. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.03.011 · Cited by 21
Bioaerosols in Health-Care Environments
Grosskopf, K., & Mousavi, E. S. (2014) · ASHRAE journal · Cited by 21
Human Respiratory Syncytial Virus Infection
Resch, B. (2011) · InTech eBooks · doi:10.5772/1496 · Cited by 21
Domino, S. P. (2021) · International journal of computational fluid dynamics · doi:10.1080/10618562.2021.1905801 · Cited by 21
“The generation of droplet nuclei, or aerosols in the 5μm range, that arise from coughs, sneezes, breathing or speaking (Nicas, Nazaroff, and Hubbard 2005; Tellier 2005), in addition to the half-time viability estimates of SARS-CoV-2 of approximately 1 h (van Doremalen et al. 2020), suggest…”
BackgroundWestern Cold and Flu (WeCoF) aerosol study – preliminary results
Savory, E., Lin, W. E., Blackman, K., Roberto, M. C., Cuthbertson, L. R., Scott, J. A., & Mubareka, S. (2014) · BMC Research Notes · doi:10.1186/1756-0500-7-563 · Cited by 20
“Evaporation and particle shrinkage are expected since particles typically enter an environment at lower RH than the respiratory tract [14].”
BackgroundMethodWedel, J., Steinmann, P., Štrakl, M., Hriberšek, M., & Ravnik, J. (2021) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09613-7 · Cited by 20
Katal, A., Wang, L. L., & Albettar, M. (2022) · Sustainable Cities and Society · doi:10.1016/j.scs.2022.103810 · Cited by 20
Zonal modeling of air distribution impact on the long-range airborne transmission risk of SARS-CoV-2
Aganović, A., Cao, G., Kurnitski, J., Melikov, A. K., & Wargocki, P. L. (2022) · Applied Mathematical Modelling · doi:10.1016/j.apm.2022.08.027 · Cited by 20
Lai, A. C. K., & Wong, S. L. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2011.571308 · Cited by 20
“The risk of infection depends on the pathogen concentration (Nicas et al. 2005).”
BackgroundChen, C., Zhao, B., Lai, D., & Liu, W. (2018) · Building Simulation · doi:10.1007/s12273-018-0441-0 · Cited by 20
“An infected person can exhale particles carrying infectious viruses when breathing, coughing, or sneezing (Nicas et al.”
BackgroundUnderstanding lifetime and dispersion of cough-emitted droplets in air
Lordly, K., Kober, L., Jadidi, M., Antoun, S., Dworkin, S. B., & Karataş, A. E. (2022) · Indoor and Built Environment · doi:10.1177/1420326x221098753 · Cited by 20
Wang, L., Lin, T., Costa, H. D., Zhu, S., Stockman, T., Kumar, A., Weaver, J. R., Spede, M., Milton, D. K., Hertzberg, J., et al. (2022) · Indoor Air · doi:10.1111/ina.13064 · Cited by 21
Wang, T., Shi, F., Shi, F., Li, C., Zhang, L., Wang, J., Jiang, C. W., Qian, B., Dai, L., & Ji, P. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110117 · Cited by 19
Metadata
- Authors
- Nicas, M., Nazaroff, W. W., & Hubbard, A.
- Affiliations
- University of California, Berkeley (US)
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2005-03
- Volume
- 2
- Issue
- 3
- Pages
- 143-154
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- PMC
- PMC7196697
- OpenAlex
- W2160555964
- Semantic Scholar
- 5f68ff03fcf2875fb3f48dd57dd1160839c8c42a
- Cited by
- 867
- References
- 36
- Citations by year
- 2026: 23 · 2025: 55 · 2024: 56 · 2023: 75 · 2022: 100 · 2021: 149 · 2020: 93 · 2019: 12 · 2018: 22 · 2017: 17 · 2016: 20 · 2015: 25 · 2014: 21 · 2013: 34 · 2012: 24
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Centers for Disease Control and Prevention
- National Institute for Occupational Safety and Health
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Keywords
- airborne transmission, respiratory aerosols, respiratory pathogens, tuberculosis, cough, sneezing, particle size distribution, alveolar deposition, air disinfection, ventilation, superspreaders, infection risk, infectious dose, indoor air exposure
- MeSH terms
- Aerosols, Cough, Humans, Models, Theoretical, Particle Size, Pulmonary Alveoli, Risk Factors, Tuberculosis, Pulmonary, Risk Assessment, Inhalation Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.