New Respirator Fit Test Panels Representing the Current U.S. Civilian Work Force
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The fit test panels currently used for respirator research, design, and certification are 25-subject panels developed by Los Alamos National Laboratory (LANL) and are based on data from the 1967 and 1968 anthropometric surveys of U.S. Air Force personnel. Military data do not represent the great diversity in face size and shape seen in civilian populations. In addition, the demographics of the U.S. population have changed over the last 30 years. Thus, it is necessary to assess and refine the LANL fit test panels. This paper presents the development of new respirator fit test panels representative of current U.S. civilian workers based on an anthropometric survey of 3,997 respirator users conducted in 2003. One panel was developed using face length and face width (bivariate approach) and weighting subjects to match the age and race distribution of the U.S. population as determined from the 2000 census. Another panel was developed using the first two principal components obtained from a set of 10 facial dimensions (age and race adjusted). These 10 dimensions are associated with respirator fit and leakage and can predict the remaining face dimensions well. Respirators designed to fit these panels are expected to accommodate more than 95% of the current U.S. civilian workers. Both panels are more representative of the U.S. population than the existing LANL panel and may be appropriate for testing both half-masks and full-face piece respirators. Respirator manufacturers, standards development organizations, and government respirator certification bodies need to select the appropriate fit test panel for their particular needs. The bivariate panel is simpler to use than the principal component analysis (PCA) panel and is most similar to the LANL panel currently used. The inclusion of the eight additional facial measurements allows the PCA panel to provide better criteria for excluding extreme face sizes from being used. Because the boundaries of the two new panels are significantly different from the LANL panel, it may be necessary to develop new respirator sizing systems. A new five-category sizing system is proposed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Based on the bivariate panel described by [95] for facial size distribution, five subjects were of smaller facial sizes, four were of medium facial sizes, and two were larger facial sizes.”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [95]
Citations
Cites
The application of electronic computers to factor analysis
Kaiser, H. F. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000116 · Cited by 12,459 · cited 1×
“, only PCs with eigenvalues greater than 1) was used to determine how many PCs to retain.(22) In essence, this is like saying that unless a PC extracts at least as much variation as the equivalent of one original variable, it is dropped.”
MethodFundamentals of Biostatistics.
(1969) · Annals of Internal Medicine · doi:10.7326/0003-4819-70-4-873 · Cited by 4,575
Head-and-Face Anthropometric Survey of U.S. Respirator Users
Zhuang, Z., & Bradtmiller, B. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500324727 · Cited by 195 · cited 4×
“The 2003 NIOSH survey was a nationwide anthropometric survey of respirator users across the United States.”
BackgroundMethodSelf-citationThe Effect of Subject Characteristics and Respirator Features on Respirator Fit
Zhuang, Z., Coffey, C. C., & Ann, R. B. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500391668 · Cited by 93 · cited 5×
“The variation of respirator fit in each cell has not been investigated in the past; however, at least one study found that a single size facepiece does not fit the population well.(18)”
BackgroundMethodResultSelf-citationOESTENSTAD, R. K., DILLION, H. K., & PERKINS, L. L. (1990) · American Industrial Hygiene Association Journal · doi:10.1080/15298669091369664 · Cited by 83
Respirator protection factors: Part I — Development of an anthropometric test panel
HACK, A. L., & McConville, J. T. (1978) · American Industrial Hygiene Association Journal · doi:10.1080/0002889778507897 · Cited by 62 · cited 1×
“( 3 , 4 ) The upper limit of the panel was defined by the mean value of male population plus two standard deviations, and the lower limit was defined by the mean value of the female population minus two standard deviations.”
BackgroundThe University of Alabama at Birmingham
Bland, K. I. (2002) · Archives of Surgery · doi:10.1001/archsurg.137.10.1095 · Cited by 57
Anthropometry of air force women
(1973) · Applied Ergonomics · doi:10.1016/0003-6870(73)90105-1 · Cited by 56
Facial Dimensions and Predictors of Fit for Half-Mask Respirators in Koreans
Han, D.-H., & Choi, K.-L. (2003) · AIHA Journal · doi:10.1080/15428110308984877 · Cited by 53
AN ASSESSMENT OF CRITICAL ANTHROPOMETRIC DIMENSIONS FOR PREDICTING THE FIT OF A HALF-MASK RESPIRATOR
Oestenstad, R. K., & Perkins, L. L. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360283 · Cited by 50
Research works printed but not linked: 6
- Harry G, 1986, A Collation of United States Air Force Anthropometry, by K.W. Kennedy (Technical Report AAMRL-TR-85-062)
- Los Alamos Scientific Laboratory:, 1973, Selection of Respirator Test Panels Representative of U.S. Adult Facial Sizes by A.L. Hack, E.C. Hyatt, B.J. Held, T.O. Moore, C.P. Richards, and J.T. McConville (Report, LA5488)
- Zhuang Z., 2002, J. Int. Soc. Resp. Prot., 19, 42
- Zhuang Z., 2004, J. Int. Soc. Resp. Prot., 21, 83
- U.S. Census Bureau:, 2002, Census 2000 Basics
- Armstrong Laboratory:, 1993, A Multivariate Anthropometric Method for Crew Station Design: Abridged (U) by G.F. Zehner, R.S. Meindl, and J.A. Hudson (Technical Report AL-TR-1992-0164)
Cited by
Grinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T., McKay, R. T., & Lee, S.-A. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903120086 · Cited by 353
“(8) The test population comprised healthy adults between 19 and 49 years of age, including 15 males and 10 females; 11 Caucasians, 3 African Americans, 1 Hispanic American, and 10 Asians/Asian Americans.”
BackgroundFacial Anthropometric Differences among Gender, Ethnicity, and Age Groups
(2010) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meq007 · Cited by 209
Self-citationEffectiveness of face masks used to protect Beijing residents against particulate air pollution
Cherrie, J. W., Apsley, A., Cowie, H., Steinle, S., Mueller, W., Lin, C., Horwell, C. J., Sleeuwenhoek, A., & Loh, M. (2018) · Occupational and Environmental Medicine · doi:10.1136/oemed-2017-104765 · Cited by 174
“Volunteers were classified as either small/ medium or large face sizes by National Institute for Occupational Safety and Health (NIOSH) guidelines based on face length and width 21 and through the assessment of lip length and face depth.”
MethodThe Role of Fit Testing N95/Ffp2/Ffp3 Masks: A Narrative Review
Regli, A., Sommerfield, A., & von Ungern‐Sternberg, B. S. (2021) · Anaesthesia · doi:10.1111/anae.15261 · Cited by 117
“In the USA, an N95mask must provide adequate fit to at least 95% of a defined fit test panel to meet the National Institute for Occupational Safety and Health (NIOSH) standard [33, 34].”
BackgroundDigital 3-D headforms with facial features representative of the current US workforce
Zhuang, Z., Benson, S. M., & Viscusi, D. J. (2010) · Ergonomics · doi:10.1080/00140130903581656 · Cited by 92
“Over 15% of NIOSH survey subjects were excluded from the full-face piece respirator fit test panel, resulting in the creation of new fit test panels (Zhuang et al. 2007).”
BackgroundMethodSelf-citationLei, Z., Yang, J., Zhuang, Z., & Roberge, R. J. (2012) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mes085 · Cited by 97
“In 2003, the National Institute for Occupational Safety and Health (NIOSH) conducted an anthropometric survey of 3997 US civilian workers and developed new respirator fit test panels including a bivariate panel and a principal component analysis (PCA) panel (Zhuang and Bradtmiller, 2005; Zhuang et al., 2007).”
BackgroundMethodSelf-citationMcMahon, E., Wada, K., & Dufresne, A. (2008) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.10.014 · Cited by 74
“Using facial length and width measurements, it may be possible to plot these dimensions against the NIOSH bivariate panel used to help manufacturers determine optimum respirator design, as described by Zhuang et al.(10)”
MethodDuncan, S., Bodurtha, P., & Naqvi, S. (2021) · PLOS ONE · doi:10.1371/journal.pone.0258191 · Cited by 75
Head-and-Face Anthropometric Survey of Chinese Workers
Du, L., Zhuang, Z., Guan, H., Xing, J., Tang, X., Wang, L., Wang, Z., Wang, H., Liu, Y., Su, W., et al. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men056 · Cited by 75
“These 5 dimensions (face length, face width, nose protrusion, bigonial breadth and nasal root breadth) are a subset of the 10 dimensions that were selected for principal component analyses by Zhuang et al. (2007) .”
MethodSelf-citationLei, Z., Yang, J., & Zhuang, Z. (2011) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2011.635130 · Cited by 74
Self-citationAnthropometric Procedures for Protective Equipment Sizing and Design
Hsiao, H. (2012) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720812465640 · Cited by 62
“Cell boundaries were then adjusted so that the population can be distributed among cells as uniformly as possible while maintaining that each cell has at least two models and that at least 95% of the population was included in the panel (Zhuang et al., 2007).”
BackgroundSteinle, S., Sleeuwenhoek, A., Mueller, W. A., Horwell, C. J., Apsley, A., Davis, A., Cherrie, J. W., & Galea, K. S. (2018) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2018.03.011 · Cited by 63
“Three volunteers were classified as having ‘short-wide’ faces, two were ‘small’, four were ‘medium’, and one was ‘large’ (Zhuang et al., 2007) as reproduced here in Fig.”
MethodInfluentialHead-and-face shape variations of U.S. civilian workers
Zhuang, Z., Shu, C., Xi, P., Bergman, M. S., & Joseph, M. (2013) · Applied Ergonomics · doi:10.1016/j.apergo.2013.01.008 · Cited by 55
“Using this data, ten facial dimensions relevant to respirator fit were chosen for defining a Principal Component Analysis (PCA) model, which divides the user population into five face-size categories (small, medium, large, long/narrow and short/ wide) (Zhuang et al., 2007; Zhuang et al., 2010).”
InfluentialSelf-citationLin, Y.-C., & Chen, C. (2017) · PLoS ONE · doi:10.1371/journal.pone.0188638 · Cited by 60
Factors Affecting the Location and Shape of Face Seal Leak Sites on Half-Mask Respirators
Oestenstad, R. K., & Bartolucci, A. A. (2010) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459621003729909 · Cited by 54
“were within the National Institute for Occupational Safety and Health (NIOSH) Fit Test Panel(17) indicating that this group was representative of a U.”
BackgroundMethodInfluentialDevelopment of an Advanced Respirator Fit-Test Headform
Bergman, M. S., Zhuang, Z., Hanson, D. F., Heimbuch, B. K., McDonald, M. J., Palmiero, A. J., Shaffer, R. E., Harnish, D. A., Husband, M., & Wander, J. D. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.816434 · Cited by 62
“The StAH is of the medium size defined by the NIOSH Principal Component Analysis (PCA) panel.(29) The PCA panel was created using data from a large-scale anthropometric survey of U.”
BackgroundMethodInfluentialSelf-citation3D parametric human face modeling for personalized product design: Eyeglasses frame design case
Chu, C., Wang, I.-J., Wang, J.-B., & Luh, Y.-P. (2017) · Advanced Engineering Informatics · doi:10.1016/j.aei.2017.03.001 · Cited by 49
New Respirator Fit Test Panels Representing the Current Chinese Civilian Workers
Chen, W., Zhuang, Z., Benson, S. M., Du, L., Yu, D., Landsittel, D. P., Wang, L., Viscusi, D. J., & Shaffer, R. E. (2009) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men089 · Cited by 53
Self-citationAnalysis of the facial measurements of Korean Air Force pilots for oxygen mask design
Lee, W., Jeong, J., Park, J., Jeon, E.-J., Kim, H.-E., Jung, D., Park, S., & You, H. (2013) · Ergonomics · doi:10.1080/00140139.2013.816376 · Cited by 45
“Furthermore, anthropometric measurements often significantly differ between military personnel and civilians (Lee et al. 2013; Zhuang, Bradtmiller, and Shaffer 2007).”
BackgroundCorrelation Between Respirator Fit and Respirator Fit Test Panel Cells by Respirator Size
Zhuang, Z., Groce, D. W., Ahlers, H., Iskander, W. H., Landsittel, D. P., Guffey, S. E., Benson, S. M., Viscusi, D. J., & Shaffer, R. E. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802293810 · Cited by 46
“( 11 ) developed criteria for two new fit test panels for both half-mask and full-facepiece respirators ( Figures 3 and 4 ).”
BackgroundSelf-citationDai, J., Yang, J., & Zhuang, Z. (2011) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2011.01.007 · Cited by 39
Self-citationChopra, J., Abiakam, N., Kim, H., Metcalf, C., Worsley, P. R., & Cheong, Y. C. (2021) · BMJ Global Health · doi:10.1136/bmjgh-2021-005537 · Cited by 47
“22 In the UK, BSI standards have been based on the 50th percentile of four dimensions (face length, face width, face depth and mouth width) of the adult white male face shape (figure 1).”
Manganyi, J., Wilson, K. S., & Rees, D. (2017) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxx077 · Cited by 36
“Men achieved a significantly higher proportion of passes than women, a finding consistent with other studies (Han, 2000; Zhuang et al., 2007b), probably because medium respirators fit men better than women.”
BackgroundResultRespirator Performance against Nanoparticles under Simulated Workplace Activities
Vo, E., Zhuang, Z., Horvatin, M., Liu, Y., He, X., & Rengasamy, S. (2015) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mev042 · Cited by 39
“The NIOSH bivariate panel was used for placement of test subjects in specific face length by face width cells (Zhuang et al., 2007).”
Self-citationDesign customization of respiratory mask based on 3D face anthropometric data
Chu, C., Huang, S.-H., Yang, C., & Tseng, C.-Y. (2015) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-015-0066-5 · Cited by 33
He, X., Grinshpun, S. A., Reponen, T. A., McKay, R. T., Bergman, M. S., & Zhuang, Z. (2013) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/met053 · Cited by 42
“Briefly, the headform is of the medium size defined by the NIOSH Principal Component Analysis panel created using data from a large-scale anthropometric survey of US workers conducted in 2003 (Zhuang et al., 2007).”
MethodSelf-citationRespirator fit of a medium mask on a group of South Africans: a cross-sectional study
Spies, A., Wilson, K. S., & Ferrie, R. T. (2011) · Environmental Health · doi:10.1186/1476-069x-10-17 · Cited by 34
Guha, S., McCaffrey, B., Hariharan, P., & Myers, M. R. (2017) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2016.1237029 · Cited by 36
“[28] One of the models is for small face types (classified based on anthropometric data of the US civilian work force[29] named A1 in this article) and another for large face types (A2).”
BackgroundTemporal changes in filtering-facepiece respirator fit
Zhuang, Z., Bergman, M. S., Brochu, E., Palmiero, A. J., Niezgoda, G., He, X., Roberge, R. J., & Shaffer, R. E. (2015) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1116692 · Cited by 31
Self-citation3D Statistical Head Modeling for Face/head-Related Product Design: A State-of-the-Art Review
Zhang, J., Luximon, Y., Shah, P., & Li, P. (2023) · Computer-Aided Design · doi:10.1016/j.cad.2023.103483 · Cited by 35
Joe, P. S., Ito, Y., Shih, A. M., Oestenstad, R. K., & Lungu, C. T. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2011.640557 · Cited by 29
An anthropometric analysis of Korean male helicopter pilots for helicopter cockpit design
Lee, W., Jung, K., Jeong, J., Park, J., Cho, J., Kim, H.-E., Park, S., & You, H. (2013) · Ergonomics · doi:10.1080/00140139.2013.776703 · Cited by 28
“…Korean Army may be limited because the anthropometric characteristics of the Korean civilian population can be significantly different from those of the Korean helicopter pilot population due to occupational factors (Roebuck 1995; Sanders and McCormick 1998; Zhuang, Bradtmiller, and Shaffer 2007).”
BackgroundDigital 3-D Headforms Representative of Chinese Workers
Yu, Y.-Y., Benson, S. M., Cheng, W., Hsiao, J., Liu, Y., Zhuang, Z., & Chen, W. (2011) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mer074 · Cited by 28
“, 2009) and can predict other dimensions which were not included (Zhuang et al., 2007).”
BackgroundSelf-citationSimulating the Interaction between a Respirator and a Headform Using LS-DYNA
Yang, J., Dai, J., & Zhuang, Z. (2009) · Computer-Aided Design and Applications · doi:10.3722/cadaps.2009.539-551 · Cited by 26
“The criteria for choosing an individual 3-D head scan was based on calculations of principal components one (PC1) and two (PC2) [19].”
BackgroundMethodSelf-citationFit Testing Respirators for Public Health Medical Emergencies
Brosseau, L. M. (2010) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2010.514782 · Cited by 26
“” Test panel characteristics should be based on published scientific standards, such as the NIOSH bivariate or Los Alamos panels, ( 5 ) and must consist of enough subjects to ensure valid statistical analyses.”
Bergman, M. S., Zhuang, Z., Brochu, E., & Palmiero, A. J. (2015) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.166885 · Cited by 33
Self-citationHuh, Y. J., Jeong, H. M., Lim, J., Park, H. Y., Kim, M. Y., Oh, H. S., & Huh, K. (2018) · Infection Control and Hospital Epidemiology · doi:10.1017/ice.2017.271 · Cited by 25
“The facial measurements were used to determine the subjects’ placement according to the NIOSH bivariate panel.(3) The subjects donned an FFR and performed a USC by inhaling and exhaling sharply while cupping both hands over the FFR, according to the manufacturers’ instructions.”
MethodReliability and Accuracy of 2D Photogrammetry: A Comparison With Direct Measurement
Lim, Y. C., Shakor, A. S. A., & Shaharudin, R. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2021.813058 · Cited by 30
“Moreover, the study in the United States showed that respirators designed to fit PCA panel are expected to accommodate more than 95% of current US civilian workers (30).”
BackgroundInfluentialRoberge, M. R., Vojtko, M. R., Roberge, R. J., Vojtko, R. J., & Landsittel, D. P. (2008) · Respiratory Care · doi:10.4187/respcare.08531685 · Cited by 24
The human factors/ergonomics studies for respirators: a review and future work
Chen, Y., Wang, J., & Yang, Z. (2015) · International Journal of Clothing Science and Technology · doi:10.1108/ijcst-06-2014-0077 · Cited by 27
Modeling 3D geometric growth patterns and variations of Children's heads
Zhang, J., Fu, F., Shi, X., & Luximon, Y. (2022) · Applied Ergonomics · doi:10.1016/j.apergo.2022.103933 · Cited by 28
Evaluation of the Benefit of the User Seal Check on N95 Filtering Facepiece Respirator Fit
Viscusi, D. J., Bergman, M. S., Zhuang, Z., & Shaffer, R. E. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.683757 · Cited by 25
“( 27 ) Two of the 11 subjects fell outside the NIOSH panel.”
Self-citationZhuang, Z., Bergman, M. S., Lei, Z., Niezgoda, G., & Shaffer, R. E. (2017) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2017.1296233 · Cited by 25
“[17] In the current study, subject facial characteristics, including face length and face width, were measured to assign test subjects to the 10 cells.”
Self-citationA Novel Algorithm for Determining Contact Area Between a Respirator and a Headform
Lei, Z., Yang, J., & Zhuang, Z. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.858818 · Cited by 24
Self-citationKim, H., Baek, J.-E., Seo, H., Lee, J.-E., Myong, J., Lee, S.-J., & Lee, J.-H. (2015) · Industrial Health · doi:10.2486/indhealth.2014-0259 · Cited by 21
Anthropometry of Brazilian Air Force pilots
da Silva, G. V., Halpern, M., & Gordon, C. C. (2017) · Ergonomics · doi:10.1080/00140139.2017.1301575 · Cited by 19
“A critical, but often overlooked, step in the ergonomic design process is determining the intended users of the equipment, or defining the target population (HFES 300 Committee 2004; Zhuang and Bradtmiller 2005; Zhuang, Bradtmiller, and Shaffer 2007).”
BackgroundCheberyachko, S., Cheberyachko, Y., Naumov, M., & Deryugin, O. V. (2020) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2020.1869429 · Cited by 18
“For example, a database of anthropometric parameters was created, according to which corresponding tables were made [10,11], the influence of a dust respirator on the physiological state of workers was studied [12], the change of protective efficiency depending on operating conditions was estimated [13,14], etc.”
BackgroundCorrelation of Respirator Fit Measured on Human Subjects and a Static Advanced Headform
Bergman, M. S., He, X., Joseph, M., Zhuang, Z., Heimbuch, B. K., Shaffer, R. E., Choe, M., & Wander, J. D. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2014.957832 · Cited by 24
“(7,9) The StAH incorporates a silicone elastomer skin with defined tissue depth at specified facial landmarks.”
Self-citationGao, S., Kim, J. Y., Yermakov, M. V., Elmashae, Y., He, X., Reponen, T. A., Zhuang, Z., Rengasamy, S., & Grinshpun, S. A. (2016) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mew019 · Cited by 20
Self-citationThe Variation in 3D Face Shapes of Dutch Children for Mask Design
Goto, L., Lee, W., Huysmans, T., Molenbroek, J. F. M., & Goossens, R. (2021) · Applied Sciences · doi:10.3390/app11156843 · Cited by 22
Gao, S., McKay, R. T., Yermakov, M. V., Kim, J. Y., Reponen, T. A., He, X., Kimura, K., & Grinshpun, S. A. (2015) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1098780 · Cited by 19
What We Are Learning from COVID-19 for Respiratory Protection: Contemporary and Emerging Issues
Li, R., Zhang, M., Wu, Y., Tang, P., Sun, G. Z., Wang, L., Mandal, S., Wang, L., Lang, J. A., Passalacqua, A., et al. (2021) · Polymers · doi:10.3390/polym13234165 · Cited by 18
“In the US, an N95 respirator must provide an adequate fit for at least 95% of human subjects in a test panel [149,150].”
BackgroundMilosevic, M., Biswas, R. K., Innes, L., Ng, M., Darendeliler, A. M., Wong, A., & Denney‐Wilson, E. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2021.12.016 · Cited by 16
“, FFR design was based on a panel to fit more than 95% of American civilians.(23) Women and individuals with Asian racial backgrounds were under-represented in this panel.”
Determining Sample Size and a Passing Criterion for Respirator Fit-Test Panels
Landsittel, D. P., Zhuang, Z., Newcomb, W. E., & Ann, R. B. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.843780 · Cited by 16
Self-citationTHE CHINESE FACE: A 3D ANTHROPOMETRIC ANALYSIS
Luximon, Y., Ball, R. M., & Justice, L. (2010) · PolyU Institutional Research Archive (Hong Kong Polytechnic University) · Cited by 16
Fakherpour, A., Jahangiri, M., & Jansz, J. (2023) · PLOS ONE · doi:10.1371/journal.pone.0293129 · Cited by 15
Kim, H., Lee, J., Lee, S., Oh, J., Kang, B., Lim, T. H., & Kang, H. (2019) · Medicine · doi:10.1097/md.0000000000014250 · Cited by 21
Shape Analysis of 3D Head Scan Data for U.S. Respirator Users
Zhuang, Z., Slice, D. E., Benson, S. M., Lynch, S., & Viscusi, D. J. (2010) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/2010/248954 · Cited by 15
“, who performed a PCA using 10 linear dimensions related to respirator fit [5].”
BackgroundMethodInfluentialSelf-citationRESPIRATORY PROTECTIVE DEVICES
Johnson, J. S. (2019) · doi:10.1002/9781119581482.ch16 · Cited by 15
Duncan, S., Bodurtha, P., Bourgeois, C., Dickson, E., Jensen, C., & Naqvi, S. (2020) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2020.1829633 · Cited by 14
Zhuang, Z., Benson, S. M., Lynch, S., Palmiero, A., & Roberge, R. J. (2011) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2011.627294 · Cited by 14
Self-citationRodríguez, A. A., Escanilla, D. E., Caroca, L. A., Albornoz, C. E., Marshall, P. A., Molenbroek, J. F. M., & Castellucci, H. I. (2020) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2020.103015 · Cited by 16
Lei, Z., Ji, X., Li, N., Yang, J., Zhuang, Z., & Rottach, D. R. (2014) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meu064 · Cited by 15
“Small Short/wide Medium Long/narrow Large”
Self-citationNiu, X., Koehler, R. H., Yermakov, M. V., & Grinshpun, S. A. (2022) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxac051 · Cited by 14
“The face dimensions, specifically the width and length, were initially collected from 30 subjects as a prescreening effort aiming at selecting the final study cohort with a broad variety of facial dimensions that fit the latest NIOSH-approved bivariate panel (Zhuang et al., 2007; NIOSH, 2018).”
MethodHead and face anthropometric study for respirators in the multi-ethnic Asian population of Malaysia
Lim, Y. C., Shakor, A. S. A., Mohamad, N., Pahrol, M. A., Ismail, R., Chong, Z. L., Mutalip, M. H. A., Omar, M. A., Danaee, M., Wan, G. T., et al. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.972249 · Cited by 16
If the mask fits: Facial dimensions and mask performance
Winski, T. A., Mueller, W. A., & Graveling, R. A. (2019) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2019.05.011 · Cited by 15
Subject validation of reusable N95 stop-gap filtering facepiece respirators in COVID-19 pandemic
Ng, W. C. K., Hondjeu, A. R. M., Syrett, A., Caragata, R., Rozenberg, D., Xiao, Z., Anwari, V., Trac, J., & Mashari, A. (2020) · PLoS ONE · doi:10.1371/journal.pone.0242304 · Cited by 12
“It divides individuals into 10 different groups based on permutations of their facial length and width [5].”
BackgroundMethodErgonomics and Personalization of Noninvasive Ventilation Masks
Cui, X., Jung, H., Lee, W., Kim, S. H., Yun, R. Y., Kim, S.-Y., You, H., & Huh, S. (2021) · Respiratory Care · doi:10.4187/respcare.08959 · Cited by 11
“24-28 For example, Lee et al 28 developed an ergonomically designed oxygen mask based on an analysis of face shapes and sizes, resulting in a 33–56% decrease in discomfort and a 11–33% decrease in contact pressure compared with existing masks.”
Commentary: A Must for NIOSH: Certify Fit Performance of the Half Mask Particulate Respirator
Lofgren, D. J. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.733578 · Cited by 12
Qualitative fitting characteristics of filtering face-piece respirators on Iranian people
Fakherpour, A., Jahangiri, M., & Seif, M. (2020) · Journal of Environmental Health Science and Engineering · doi:10.1007/s40201-020-00484-x · Cited by 13
“Before undertaking the investigation, we gave the participant a description of his/her responsibilities during the test procedure by playing two videos concerning the steps of QLFT procedure, including sensitivity test, user seal checks (USCs) and respirator fit testing procedures [35, 47].”
MethodA New Approach to Developing Digital 3-D Headforms
Zhuang, Z., & Viscusi, D. J. (2008) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2008-01-1878 · Cited by 11
Self-citationAn exploratory study of fit assessment of the virtual reality glasses
Jin, W., & He, R. (2021) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-021-03335-1 · Cited by 10
Anlysis Methods of the Variation of Facial Size and Shape Based on 3d Face Scan Images
Lee, W., Goto, L., Molenbroek, J. F. M., & Goossens, R. (2017) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1541931213601836 · Cited by 10
“Chen et al. (2009), Goto et al. (2015), and Zhuang et al. (2007) analyzed the variation of head size using principal component analysis (PCA) based on several anthropometric dimensions to develop a sizing system.”
MethodAre quantitative fit factors predictive of respirator fit during simulated healthcare activities?
Sietsema, M., & Brosseau, L. M. (2018) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1515490 · Cited by 12
Roberge, R. J., Palmiero, A. J., Liu, Y., Kim, J., & Zhuang, Z. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.866716 · Cited by 9
Self-citationA Novel Method for Designing and Fabricating Low-cost Facepiece Prototypes
Joe, P. S., Shum, P. C., Brown, D. W., & Lungu, C. T. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2014.908260 · Cited by 9
Development of Headforms for ISO Eye and Face Protection Standards
Niezgoda, G., & Zhuang, Z. (2015) · Procedia Manufacturing · doi:10.1016/j.promfg.2015.07.822 · Cited by 8
Self-citationLee, S., Kim, H., Lim, T. H., Oh, J., Kang, H., Ahn, C., Song, Y., Lee, J., & Shin, H. (2017) · Hong Kong Journal of Emergency Medicine · doi:10.1177/1024907917735088 · Cited by 9
Requirements to respiratory protection for workers (World practices reviewed)
Va, K., & Chirkin, A. V. (2020) · Health Risk Analysis · doi:10.21668/health.risk/2020.4.21 · Cited by 8
Comparison of two quantitative fit-test methods using N95 filtering facepiece respirators
Sietsema, M., & Brosseau, L. M. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2016.1159690 · Cited by 9
Comparison of Fit Factor for Healthcare Workers Before and After Training with the N95 Mask
Kim, H., Baek, J. E., Seo, H. K., Lee, J., Myong, J., Lee, S., & Lee, J. (2014) · Journal of Korean Society of Occupational and Environmental Hygiene · doi:10.15269/jksoeh.2014.24.4.528 · Cited by 8
Qualitative Fit Testing of Medium - Size N95/FFP2 Respirators on Iranian Health Care Workers
Honarbakhsh, M., Jahangiri, M., Ghaem, H., Ghorbani, M., Omidvari, F., khorasani, M. A., & Shabani, F. (2018) · Health Scope · doi:10.5812/jhealthscope.62884 · Cited by 9
“If the length and width were laid on the borders of panel, the person was placed inside the cells with a higher number and larger facial dimensions (19).”
BackgroundMethodInfluentialDavidson, C. S., Green, C. F., Panlilio, A. L., Jensen, P. A., Stover, B. H., Roselle, G. A., Gibbs, S. G., & Scarpino, P. V. (2010) · Indoor and Built Environment · doi:10.1177/1420326x10378805 · Cited by 7
Inward Leakage Variability between Respirator Fit Test Panels – Part I. Deterministic Approach
Zhuang, Z., Liu, Y., Coffey, C. C., Miller, C., & Szalajda, J. V. (2015) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1047025 · Cited by 7
Self-citationImpact of time and assisted donning on respirator fit
Rembialkowski, B., Sietsema, M., & Brosseau, L. M. (2017) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2017.1319569 · Cited by 7
Dellweg, D., Haidl, P., Kerl, J., Maurer, L., & Köhler, D. (2021) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2020.1862417 · Cited by 7
“The head corresponds to medium standard NIOSH head form (Zhuang et al. 2007).”
BackgroundVariation in the fitted filtration efficiency of disposable face masks by sex
Pennington, E. R., Griffin, J. S., Mcinroe, E. M., Steinhardt, W., Chen, H., Samet, J. M., & Prince, S. E. (2024) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-024-00697-4 · Cited by 6
Deriving statistical fit contours and shape of an aerosol mask from 3D head scans
Krishnamurthy, H., & Sen, D. (2011) · International Journal of Human Factors Modelling and Simulation · doi:10.1504/ijhfms.2011.045001 · Cited by 6
Yang, L., Wei, R., & Shen, H. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2016.1207778 · Cited by 6
Effect of the tight fitting net on fit performance in single-use filtering facepieces for Koreans
Han, D., Yesol, P. A. R. K., & Jae-Jong, W. O. O. (2017) · Industrial Health · doi:10.2486/indhealth.2017-0069 · Cited by 6
Assessment of respirator fit capability test criteria for full-facepiece air-purifying respirators
Bergman, M. S., Zhuang, Z., Xu, S. S., Rengasamy, S., Lawrence, R. B., Boutin, B. K., & Harris, J. R. (2019) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2019.1609006 · Cited by 6
Self-citationIntra-rater and inter-rater reliability of 3D facial measurements
Hobbs-Murphy, K., Olmedo-Nockideneh, I., Brazile, W. J., Morris, K. D., & Rosecrance, J. C. (2024) · Applied Ergonomics · doi:10.1016/j.apergo.2023.104218 · Cited by 5
Marchais, G., Arbane, M., Topilko, B., Brousseau, J., Brochot, C., Yaddaden, Y., Bahloul, A., & Maldague, X. (2024) · IEEE Access · doi:10.1109/access.2024.3522562 · Cited by 7
Yu, M., Griffin, L., Durfee, W. K., & Arnold, S. F. (2024) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxae005 · Cited by 8
Computer-Aided Customized Shape Design of an N95 Filtering Facepiece Respirator
Lei, Z., & Yang, J. (2013) · ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference (IDETC/CIE) · doi:10.1115/detc2013-13251 · Cited by 5
Manomaipiboon, A., Pupipatpab, S., Chomdee, P., Chitsomkasem, A., Apichatbutr, Y., Boonyapatkul, P., & Trakarnvanich, T. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237206 · Cited by 7
“[9], who developed respirator fit test panels by the bivariate distribution of face length and lip length in 3,997 of respirator users demonstrated that 95% of the subjects were included in the panel.”
BackgroundA Topic Modeling Analysis of the Crisis Response Stage during the COVID-19 Pandemic
Cha, K., & Kim, E.-M. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19148331 · Cited by 5
“In particular, masks are an essential type of PPE for preventing respiratory infections in employees, and N95 masks used in the care of patients with COVID-19 must be fully attached to the face of the user to be effective, thus they should be selected and utilized only after performing a fitting test [32].”
BackgroundGrinshpun, S. A., Yermakov, M. V., & Kano, M. (2020) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxaa116 · Cited by 5
“The face width (bizygomatic breadth) and face length (menton–sellion length) data were collected from each subject and compared with the facial dimensions of the NIOSH 25-member bivariate panel (Zhuang et al., 2007).”
MethodQualitative fit test outcomes for N95 filtering facepiece respirators in health care workers
Wardhan, R., Patel, V., Neff, A. B., Cook, R., White, J. D., & Vasilopoulos, T. (2022) · American Journal of Infection Control · doi:10.1016/j.ajic.2022.05.022 · Cited by 4
A Method for Generation of a Sizing System and Representative Models for a Facial Mask Design
Lee, W., Lee, B., Yang, X., & You, H. (2022) · Applied Sciences · doi:10.3390/app122312387 · Cited by 4
Metadata
- Authors
- Zhuang, Z., Bradtmiller, B., & Shaffer, R. E.
- Affiliations
- National Institute for Occupational Safety and Health (US)
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2007-07-23
- Volume
- 4
- Issue
- 9
- Pages
- 647-659
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2129506957
- Cited by
- 187
- References
- 16
- Citations by year
- 2026: 13 · 2025: 11 · 2024: 19 · 2023: 12 · 2022: 10 · 2021: 16 · 2020: 15 · 2019: 7 · 2018: 8 · 2017: 12 · 2016: 5 · 2015: 9 · 2014: 6 · 2013: 9 · 2012: 7
- FWCI
- 23.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Performance
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- respirator fit, facial anthropometry, civilian workers, principal component analysis, half-mask respirators, demographics
- MeSH terms
- Anthropometry, Cephalometry, Equipment Design, Face, Female, Humans, Male, National Institute for Occupational Safety and Health, U.S., Respiratory Protective Devices, United States, Occupational Exposure, Inhalation Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.