New Respirator Fit Test Panels Representing the Current U.S. Civilian Work Force
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The fit test panels currently used for respirator research, design, and certification are 25-subject panels developed by Los Alamos National Laboratory (LANL) and are based on data from the 1967 and 1968 anthropometric surveys of U.S. Air Force personnel. Military data do not represent the great diversity in face size and shape seen in civilian populations. In addition, the demographics of the U.S. population have changed over the last 30 years. Thus, it is necessary to assess and refine the LANL fit test panels. This paper presents the development of new respirator fit test panels representative of current U.S. civilian workers based on an anthropometric survey of 3,997 respirator users conducted in 2003. One panel was developed using face length and face width (bivariate approach) and weighting subjects to match the age and race distribution of the U.S. population as determined from the 2000 census. Another panel was developed using the first two principal components obtained from a set of 10 facial dimensions (age and race adjusted). These 10 dimensions are associated with respirator fit and leakage and can predict the remaining face dimensions well. Respirators designed to fit these panels are expected to accommodate more than 95% of the current U.S. civilian workers. Both panels are more representative of the U.S. population than the existing LANL panel and may be appropriate for testing both half-masks and full-face piece respirators. Respirator manufacturers, standards development organizations, and government respirator certification bodies need to select the appropriate fit test panel for their particular needs. The bivariate panel is simpler to use than the principal component analysis (PCA) panel and is most similar to the LANL panel currently used. The inclusion of the eight additional facial measurements allows the PCA panel to provide better criteria for excluding extreme face sizes from being used. Because the boundaries of the two new panels are significantly different from the LANL panel, it may be necessary to develop new respirator sizing systems. A new five-category sizing system is proposed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Based on the bivariate panel described by [95] for facial size distribution, five subjects were of smaller facial sizes, four were of medium facial sizes, and two were larger facial sizes.”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [95]
Citations
Cites
The application of electronic computers to factor analysis
Kaiser, H. F. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000116 · Cited by 12,459 · cited 1×
“, only PCs with eigenvalues greater than 1) was used to determine how many PCs to retain.(22) In essence, this is like saying that unless a PC extracts at least as much variation as the equivalent of one original variable, it is dropped.”
MethodFundamentals of Biostatistics.
(1969) · Annals of Internal Medicine · doi:10.7326/0003-4819-70-4-873 · Cited by 4,575
Head-and-Face Anthropometric Survey of U.S. Respirator Users
Zhuang, Z., & Bradtmiller, B. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500324727 · Cited by 195 · cited 4×
“The 2003 NIOSH survey was a nationwide anthropometric survey of respirator users across the United States.”
BackgroundMethodSelf-citationThe Effect of Subject Characteristics and Respirator Features on Respirator Fit
Zhuang, Z., Coffey, C. C., & Ann, R. B. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500391668 · Cited by 93 · cited 5×
“The variation of respirator fit in each cell has not been investigated in the past; however, at least one study found that a single size facepiece does not fit the population well.(18)”
BackgroundMethodResultSelf-citationOESTENSTAD, R. K., DILLION, H. K., & PERKINS, L. L. (1990) · American Industrial Hygiene Association Journal · doi:10.1080/15298669091369664 · Cited by 83
Respirator protection factors: Part I — Development of an anthropometric test panel
HACK, A. L., & McConville, J. T. (1978) · American Industrial Hygiene Association Journal · doi:10.1080/0002889778507897 · Cited by 62 · cited 1×
“( 3 , 4 ) The upper limit of the panel was defined by the mean value of male population plus two standard deviations, and the lower limit was defined by the mean value of the female population minus two standard deviations.”
BackgroundThe University of Alabama at Birmingham
Bland, K. I. (2002) · Archives of Surgery · doi:10.1001/archsurg.137.10.1095 · Cited by 57
Anthropometry of air force women
(1973) · Applied Ergonomics · doi:10.1016/0003-6870(73)90105-1 · Cited by 56
Facial Dimensions and Predictors of Fit for Half-Mask Respirators in Koreans
Han, D.-H., & Choi, K.-L. (2003) · AIHA Journal · doi:10.1080/15428110308984877 · Cited by 53
AN ASSESSMENT OF CRITICAL ANTHROPOMETRIC DIMENSIONS FOR PREDICTING THE FIT OF A HALF-MASK RESPIRATOR
Oestenstad, R. K., & Perkins, L. L. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360283 · Cited by 50
Research works printed but not linked: 6
- Harry G, 1986, A Collation of United States Air Force Anthropometry, by K.W. Kennedy (Technical Report AAMRL-TR-85-062)
- Los Alamos Scientific Laboratory:, 1973, Selection of Respirator Test Panels Representative of U.S. Adult Facial Sizes by A.L. Hack, E.C. Hyatt, B.J. Held, T.O. Moore, C.P. Richards, and J.T. McConville (Report, LA5488)
- Zhuang Z., 2002, J. Int. Soc. Resp. Prot., 19, 42
- Zhuang Z., 2004, J. Int. Soc. Resp. Prot., 21, 83
- U.S. Census Bureau:, 2002, Census 2000 Basics
- Armstrong Laboratory:, 1993, A Multivariate Anthropometric Method for Crew Station Design: Abridged (U) by G.F. Zehner, R.S. Meindl, and J.A. Hudson (Technical Report AL-TR-1992-0164)
Cited by
Items 101–185 of 185
Human head modeling and applications
Yang, J., & Lei, Z. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816713-7.00018-0 · Cited by 4
Designing the half-masks of filter respirators for workers of mining enterprises
Holіnko, V., Чеберячко, І. М., Symanovych, H., & Kicki, J. (2019) · E3S Web of Conferences · doi:10.1051/e3sconf/201912301001 · Cited by 4
Fakherpour, A., Jahangiri, M., & Banaee, S. (2021) · Industrial Health · doi:10.2486/indhealth.2020-0199 · Cited by 4
A Shape-based Sizing System for Facial Wearable Product Design
Lee, W., Goto, L., Molenbroek, J. F. M., Goossens, R., & Wang, C. C. L. (2017) · Cited by 4
Comparison of N95 Respiratory Mask Fit Testing
Han, S.-H., Cha, K., Yoo, S.-Y., & Han, J. O. (2021) · Korean Journal of Healthcare-Associated Infection Control and Prevention · doi:10.14192/kjicp.2021.26.2.108 · Cited by 4
“The face width and length were measured using a sliding caliper, whereas the vertical length from the root of the nose to the tip of the chin was measured in terms of face length [15].”
Inward leakage variability between respirator fit test panels – Part II. Probabilistic approach
Liu, Y., Zhuang, Z., Coffey, C. C., Rengasamy, S., & Niezgoda, G. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2016.1161198 · Cited by 4
“Head and face anthropometric measurements were performed for each candidate to check if he/she would fall within the NIOSH bivariate respirator fit test panel.[8] Distribution of the study subjects, by the bivariate panel cell, is shown in Table 1.”
MethodSelf-citationRespiratory protective device: One size to fit them all?
Santandréa, A., & Chazelet, S. (2023) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2023.2205466 · Cited by 5
“In these panels, facial dimensions are classified in cells: the bivariate panel, divided into 10 cells, is based on the face width and length, while the principal component analysis (PCA) panel is divided into eight cells and is established from a set of 10 facial dimensions (Zhuang et al. 2007).”
MethodZhang, M. M., Hackett, L., Smith, J., Pritchard, Z., Casey, M., Low, C. S., & Buntine, P. (2023) · Antimicrobial Stewardship & Healthcare Epidemiology · doi:10.1017/ash.2023.503 · Cited by 4
Respiratory Protective Equipment
Birkner, J. S., & Colton, C. E. (2011) · Wiley eBooks · doi:10.1002/0471435139.hyg032.pub2 · Cited by 4
Fu, L., Guo, J., Zhang, Y., Jing, X., Lu, L., Wang, Y., Jiang, R., & Liu, L. (2024) · Building Simulation · doi:10.1007/s12273-024-1144-3 · Cited by 4
“The number of subjects was chosen according to NIOSH bivariate panel (Zhuang et al. 2007) and Chinese bivariate panel (Chen et al. 2009).”
Hobbs-Murphy, K., Brazile, W. J., Morris, K. D., & Rosecrance, J. C. (2025) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxaf012 · Cited by 3
“PC1 and PC2 described 58.87% of the variability in the dataset and were used as the new coordinate system (Zhuang et al. 2007) to plot each observation (i.e. each participant).”
InfluentialLeppänen, M., Wu, B., Corey, J., Yermakov, M. V., & Grinshpun, S. A. (2018) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1479065 · Cited by 3
Lee, A. L., Cui, X., Jung, H., Kim, H.-E., Jeon, E. J., Na, H., Kim, E., & You, H. (2023) · Safety and Health at Work · doi:10.1016/j.shaw.2023.11.003 · Cited by 4
Virtual fit and design improvements of a filtering half-mask for sub-adult wearers
Čuta, M., Jurda, M., Kováčová, V., Jandová, M., Bezděková, V., Černý, D., & Urbanová, P. (2024) · Ergonomics · doi:10.1080/00140139.2023.2298984 · Cited by 4
“These are bizygomatic width and facial height for full-face masks, and facial height along with mouth width for half-face masks (Zhuang, Bradtmiller, and Shaffer 2007).”
InfluentialQuantitative analysis of facial shape in children to support respirator design.
Nemeth, C., Hoskens, H., Wilson, G., Jones, M., DiPietrantonio, J., Salami, B., Harnish, D., Claes, P., Weinberg, S. M., Shriver, M., et al. (2024) · Applied Ergonomics · doi:10.1016/j.apergo.2024.104375 · Cited by 2
Gakhal, M., Bakshi, A., Gu, M., & Khambay, B. (2024) · Scientific Reports · doi:10.1038/s41598-024-80001-4 · Cited by 4
Grinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T. A., McKay, R. T., & Lee, S.-A. (2021) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2021.1877051 · Cited by 5
Resolution Influence on 3D Anthropometric Data Clustering for Fitting Design
Niu, J., Li, Z., & Salvendy, G. (2009) · Industrial Health · doi:10.2486/indhealth.47.578 · Cited by 3
Han, D., & Kim, D. S. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.877143 · Cited by 3
“Recently, two new respirator fit-test panels were developed by Zhuang et al.(12) for U.”
MethodProject BREATHE – Prototype Respirator Evaluation Utilizing Newly Proposed Respirator Test Criteria
Kim, J.-H., Roberge, R. J., Shaffer, R. E., Zhuang, Z., Powell, J. B., Bergman, M. S., & Palmiero, A. J. (2017) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.166832 · Cited by 3
“…17 women (anthropometrics, 32.9±12.4 yrs, height 165.3±6.2 cm, weight 77.2±21.4 kg, BMI 28.4±8.2 kg/m 2 ), representative of the cells in the NIOSH respirator fit test panel (Zhuang and Bradtmiller, 2007), underwent quantitative fit testing (OSHA, Appendix A, 2003) on each of the four prototypes.”
InfluentialSelf-citationFinite Element Analysis for the Interface of a Respirator and the Human Face -A Pilot Study
Dai, J., Yang, J., & Zhuang, Z. (2009) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2009-01-2271 · Cited by 3
Self-citationHondjeu, A. R. M., Ng, W. C. K., Anwari, V., Xiao, M. Z. X., Rozenberg, D., Kazlovich, K., Afenu, E., Hiansen, J. Q., & Mashari, A. (2021) · Research Square · doi:10.21203/rs.3.rs-456096/v1 · Cited by 3
“34 Face length, mean (SD), mm 120 (9) 120 (7) 121 (12) 0.”
Coffey, C. C., Miller, C., & Szalajda, J. V. (2021) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2021.1976411 · Cited by 5
“The ASTM RFC standard uses 25 subjects forming a bivariate fit test panel based on the anthropometric facial survey of U.S. civilian respirator wearers conducted in 2003 (Figure 4) (Zhuang et al. 2007).”
Respiratory fit test panel representing population of Malaysia
Lim, Y. C., Soelar, S. A., Shakor, A. S. A., Mohamad, N., Pahrol, M. A., Ismail, R., Danaee, M., & Shaharudin, R. (2024) · BMC Pulmonary Medicine · doi:10.1186/s12890-024-02919-9 · Cited by 2
“A respiratory fit test is select candidates to serve as representative test subjects [1].”
BackgroundMethodResultInfluentialSilva, E. C., Castellucci, H. I., Valenzuela, S., Rodríguez, A. A., Escanilla, D. E., Caroca, L. A., Molenbroek, J. F. M., Huysmans, T., & Viviani, C. (2025) · Work · doi:10.1177/10519815241303337 · Cited by 2
Silva, E., Castellucci, H. I., Camberes, R., Lira, J., Marabolí, J., Viviani, C., Molenbroek, J. F. M., Huysmans, T., Rodríguez, A., Caroca, L. A., et al. (2025) · Applied Ergonomics · doi:10.1016/j.apergo.2025.104594 · Cited by 3
Cremasco, M. M., Vigoroso, L., Solinas, C., & Caffaro, F. (2023) · Safety · doi:10.3390/safety9020040 · Cited by 2
Inolopú-Cucche, J., Mayma-Aguirre, K. J., Curisinche-Rojas, M., Aylas, R., Flores, J. A., & Rosales‐Rimache, J. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20166618 · Cited by 1
Facial Shape Variation of U.S. Respirator Users
Zhuang, Z., Slice, D. E., Benson, S. M., Landsittel, D. P., & Viscusi, D. J. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02809-0_61 · Cited by 2
“This suggests the bivariate approach used in constructing fit panels may be ignoring a substantial and important aspect of total sample variability as previously reported [5].”
BackgroundMethodSelf-citationLane, M. A., Kraft, C. S., Ayers, M., Love, K. L., Brownsword, E. A., & Sexton, M. E. (2020) · American Journal of Infection Control · doi:10.1016/j.ajic.2020.11.001 · Cited by 2
Yoon, N., Ari, M. D., Yorio, P. L., Iskander, J. K., & D’Alessandro, M. (2022) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2022.2063875 · Cited by 2
“…panel cell and respirator size, determine panel size or number of test subjects, inter-panel variability, and pass/fail performance requirements for respirator fit capability test of half-mask air-purifying respirators (Zhuang et al. 2007, 2008; Landsittel et al. 2014; Zhuang et al. 2016, 2017).”
BackgroundOnline Virtual Simulation Course Design for VR Glasses Fit Analysis
Qiu, M., Wang, H., Du, Y., & Ju, Y. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-05897-4_33 · Cited by 2
Automated Generation of Custom Fit PPE Inserts
Vazquez, A. N., & Chen, L. (2021) · ACADIA quarterly · doi:10.52842/conf.acadia.2021.048 · Cited by 2
The Respirator Fit Capability Test: Enhancing the Efficacy of Filtering Facepiece Respirators.
Coffey, C. C., & Miller, C. (2019) · PubMed · Cited by 2
Designing of Half-Masks of Filtering Respirators
Чеберячко, С. І., Cheberiachko, Y., & Shaikhlislamova, I. (2020) · Nauka ta innovacii · doi:10.15407/scin16.05.097 · Cited by 2
“the following components are calculated by the formulas [22]:”
MethodMainstreaming in New Zealand physical education.
Hanrahan, S. J. (1991) · Taiiku no kagaku · Cited by 3
Purpose and performance of respiratory protective devices in a pandemic
Li, R., Joshi, A., Wu, Y., & Zhang, M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95316-0.00003-7 · Cited by 2
Vollmer, B., Bergman, M. S., Boyles, H., Meyers, J., Payne, N. Y., Pollard, J., & Zhuang, Z. (2025) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2025.2540829 · Cited by 2
“Within the PCA panel, the first principal component primarily captures the overall size of the face, while the second principal component captures key nasal features (Zhuang et al. 2007).”
Self-citationFit prediction for filtering facepiece respirator using 3D face shape
Yu, M., & Griffin, L. (2025) · Applied Ergonomics · doi:10.1016/j.apergo.2025.104667 · Cited by 2
3D female breasts aging patterns integrating age and BMI for ergonomic fashion design
Shi, X., Cai, Z., Zhang, J., & Yang, Y. (2026) · Fashion and Textiles · doi:10.1186/s40691-026-00474-x · Cited by 2
“Referencing the approaches proposed by Zhuang et al. (2007) and Goto et al. (2021) used in head and face products, the first two principal components of the breast SSM can be utilized in the design of breast-related products to enable mass customization of bras, garments, and related products.”
Alignment Influence on 3D Anthropometric Data Clustering
Niu, J., Li, Z., & Salvendy, G. (2008) · The Ergonomics Open Journal · doi:10.2174/1875934300801010062 · Cited by 1
“However, the choice of the alignment reference can profoundly influence the shape analytical results.”
BackgroundLayered Pentahedral Mesh Generation for Biomechanical Geometries with Unclosed Surfaces
Lei, Z., & Yang, J. (2012) · Computer-Aided Design and Applications · doi:10.3722/cadaps.2013.231-245 · Cited by 1
“civilian workers and developed a new respirator fit test panel based on two principal components, which in turn are functions of 10 facial dimensions [25],[27].”
BackgroundStudy on Face Classification and Modeling Based on the Fit Problem of Respirator for Chinese Adults
Zhou, X., & Song, X. (2018) · International Conference on Applied Mathematics, Modelling and Statistics Application (AMMSA) · doi:10.2991/ammsa-18.2018.43 · Cited by 1
“According to GB/ T5703-1999 "basic project for human measurement for technical design", the location of measurement points is marked on the head[4-7].”
BackgroundA Comparison Between Representative 3D Faces Based on Bi- and Multi-variate and Shape Based Analysis
Goto, L., Huysmans, T., Lee, W., Molenbroek, J. F. M., & Goossens, R. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-96071-5_137 · Cited by 1
“A principal component analysis was performed on 9 facial dimensions that were considered relevant to mask design based on previous research namely, face length, sellion-promentale length, nose bridge length, mouth width, nose protrusion, nasal root breadth, nose breadth, interpupillary distance and face width [4, 10,…”
MethodChapman, D., Strong, C., Dharmaprani, D., Tiver, K. D., Kaur, P., & Ganesan, A. N. (2024) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2024.2345145 · Cited by 1
“Participants were found to adequately represent each of the panels in the NIOSH Face Panel (Zhuang et al. 2007) (Figure 1) on anthropometric measurement.”
Total outward leakage of face-worn products used by the general public for source control
Yang, W., Myers, W. R., Bergman, M., Fisher, E. M., Ryan, K. J., Vollmer, B., Portnoff, L., & Zhuang, Z. (2024) · American Journal of Infection Control · doi:10.1016/j.ajic.2024.09.020 · Cited by 2
Self-citationJahangiri, M., Fakherpour, A., & Yousefinejad, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95316-0.00004-9 · Cited by 1
Yang, W., Myers, W. R., & Ryan, K. J. (2025) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2025.106586 · Cited by 1
Designing of Half-Masks of Filtering Respirators
Чеберячко, С. І., Cheberiachko, Y., & Shaikhlislamova, I. (2020) · Science and innovation · doi:10.15407/scine16.05.090 · Cited by 1
Du, Y., Wang, H., Qiu, M., & Ju, Y. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-05906-3_23 · Cited by 1
Informing the use of N95 respirators by the general public to reduce wildfire smoke exposure
Kelly, K. R. (2020) · ResearchWorks at the University of Washington (University of Washington) · Cited by 2
Yu, M., & Griffin, L. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4837907 · Cited by 2
Real-time monitoring of total inward leakage of respiratory equipment used by emergency responders :
Butler, K. M., Nyden, M. R., & Bryant, R. A. (2010) · doi:10.6028/nist.sp.1113-bfrl
To the method of development of ergonomic filter half masks
Cheberyachko, S. I., Stolbchenko, O. V., Radchuk, D., & Ziborova, M. O. (2017) · Geo-Technical mechanics · doi:10.15407/geotm2017.134.067
Simulation-based assessment for N95 filtering facepiece respirator
Lei, Z. (2014) · ThinkTech (Texas Tech University)
Respirators, Face Masks, and Diverse Populations: An Analysis of 3D Facial Anthropometrics
Hobbs-Murphy, K., Morris, K. D., BRAZILE, B., & Rosecrance, J. C. (2021) · International Conference on 3D Body Scanning Technologies (3DBST) · doi:10.15221/21.60
Dickson, E. F. G. (2012) · Wiley eBooks · doi:10.1002/9781118422991.refs
Respiratory Protective Equipment
Colton, C. E. (2021) · Wiley eBooks · doi:10.1002/0471435139.hyg032.pub3
Short: A data-driven respirator fit test model via human speech signal
Chen, J., Zhang, Z., Zhao, S., Fang, S., Peters, T. M., Floyd, E. L., & Cai, C. (2023) · Smart Health · doi:10.1016/j.smhl.2023.100400
Bergman, M. S., Grinshpun, S. A., Yermakov, M. V., Zhuang, Z., Vollmer, B., & Yoon, K. N. (2023) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2023.2226180
Self-citationZhang, X., Xu, Q., Yang, M., Liu, X., Jia, N., Wang, Z., & Sun, X. (2023) · Research Square · doi:10.21203/rs.3.rs-3340100/v1
Hondjeu, A. R. M., Ng, W., Anwari, V., Kazlovich, K., Xiao, M. Z. X., Rozenberg, D., Zalewski, A., Afenu, E., Hiansen, J. Q., & Mashari, A. (2023) · European Journal of Anaesthesiology Intensive Care · doi:10.1097/ea9.0000000000000038
ВИКОРИСТАННЯ АНТРОПОМЕТРИЧНИХ ДАНИХ РОБІТНИКІВ ДЛЯ ПРОЄКТУВАННЯ ЗАСОБІВ ІНДИВІДУАЛЬНОГО ЗАХИСТУ
Грідяєв, В. В., Манідіна, Є. А., Карпенко, Г. В., & Русаков, О. О. (2024) · Scientific Journal Metallurgy · doi:10.26661/2071-3789-2023-2-06
Forensic Analysis of Sexual Dimorphism from Facial Photographs
Panwar, P., Sharma, T., Gautam, A. S., & Sankhla, M. S. (2024) · Journal of Forensic Science and Medicine · doi:10.4103/jfsm.jfsm_122_23
Evaluation of N95 Respirator Fit Changes in Nurses Working in High-risk Airborne Infection Units
Han, S.-H., Cha, K., Lee, H., & Choung, Y. (2024) · Korean Journal of Healthcare-Associated Infection Control and Prevention · doi:10.14192/kjicp.2024.29.2.137
Silva, V. D. E., Abele, M., Bercovitz, I., & Ferguson, S. (2025) · Workplace Health & Safety · doi:10.1177/21650799241230039
“This model was selected because it is common among frontline workers and approved by the CSA and the National Institute for Occupational Safety and Health and it represents the sizes that fit most male faces (Zhuang et al., 2007).”
Silva, E., Castellucci, H. I., Camberes, R., Lira, J., Marabolí, J., Viviani, C., Molenbroek, J. F. M., Huysmans, T., Rodríguez, A., Caroca, L. A., et al. (2025) · Applied Ergonomics · doi:10.1016/j.apergo.2025.104551
Cao, Y., Yu, R., He, R., & Wang, H. (2025) · Ergonomics · doi:10.1080/00140139.2025.2519877
“…the force exerted by the device’s support mechanism and the diversity in human head and ear sizes and shapes (ellena et al. 2016; Jung and Jung 2003; Zhuang, Bradtmiller, and shaffer 2007), potentially leading to discomfort if there is a misfit. hence, considering the variations in head and…”
Head and face dimensions of Black South African respirator users
Manganyi, J., Rees, D., Brosseau, L. M., & Wilson, K. S. (2025) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxaf053
A new bivariate respirator fit test panel representing Black South African respirator users
Manganyi, J., Rees, D., Brosseau, L. M., & Wilson, K. S. (2025) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxaf083
Additional file 2 of Respiratory fit test panel representing population of Malaysia
Lim, Y. C., Soelar, S. A., Shakor¹, A. S. A., Mohamad, N., Pahrol, M. A., Ismail, R., Danaee, M., & Shaharudin, R. (2024) · Figshare · doi:10.6084/m9.figshare.25367507
Additional file 1 of Respiratory fit test panel representing population of Malaysia
Lim, Y. C., Soelar, S. A., Shakor¹, A. S. A., Mohamad, N., Pahrol, M. A., Ismail, R., Danaee, M., & Shaharudin, R. (2024) · Figshare · doi:10.6084/m9.figshare.25367358
Reassessing nasal geometry: A PCA-based comparison of 2D dimensions and 3D point net
Wang, J., Summerskill, S. J., & Mohammed, M. I. (2026) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2026.103895
Filtering facepiece respirator use among farm youth in the US: A review
Gibbs, J. L., Vollmer, B., Sheridan, C., Pinkerton, K. E., Anthony, R. T., Holm, S. M., Karr, C. J., Proctor, A., & Swenson, A. V. R. (2026) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2025.2589137
“…are predominantly organized for adult occupational settings, leaving a critical gap in evidence-based guidance for youth/pediatric FFR use (Part 84—Approval of Respiratory Protective Devices 1995; Zhuang et al. 2005, 2007; Zhuang and Bradtmiller 2005; ASTM International 2021, 2022; NIOSH 2024).”
Fit testing of N95 respirators: A pilot study on respirator design and demographic factors
Niu, X., Yermakov, M. V., Grinshpun, S. A., & Wang, J. J. (2026) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2026.2650644
“These measured facial dimensions were then plotted onto the NIOSH-approved bivariate panel to achieve the distribution of the 20 subjects within the panel (Zhuang et al. 2007; NIOSH 2018).”
Lam, S. C., Yu, I. T. S., O'Donoghue, M. M., Leung, K. K., Chong, A. C. Y., Lena Lok Ki, S. U. N. G., Odetayo, A., & Suen, L. K. P. (2026) · Infection Prevention in Practice · doi:10.1016/j.infpip.2026.100561
Hosseinabadi, M. B., Yu, M., Petersen, A. J., Griffin, L., Durfee, W. K., & Arnold, S. F. (2026) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxag050
“The current fit test panels developed by the National Institute for Occupational Safety and Health (NIOSH) are matched with the 2000 US census population which may not reflect today's more diverse population (Zhuang et al. 2007).”
Seo, H., Jang, H., & Kim, S. (2026) · Safety and Health at Work · doi:10.1016/j.shaw.2026.06.002
“The earliest test panel was the bivariate panel developed by the U.S. Air Force through anthropometric surveys conducted at the Los Alamos National Laboratory [9,10].”
Gx, H., Li, L., 樊茹, (7081), W. L., Sheng, Z. J., & Zhang, W. H. (2026) · Frontiers in Public Health · doi:10.3389/fpubh.2026.1911331
Chan, W.-Y., Ng, S.-P., Leung, S.-H. M., Yick, K., Loh, A. W.-K., Ng, S.-Y., & Lam, K. C. (2026) · Applied Sciences · doi:10.3390/app16168197
Anthropometric Face Measurements for Ergonomic Sizing of Respiratory Protective EquipmentPreprint
Dāboliņa, I., & Lapkovska, E. (2026) · Research Square · doi:10.21203/rs.3.rs-10624364/v1
Nguyen, T. T. P., Gopaldasani, V., Phung, S. L., Whitelaw, J. L., Le, H. T., & Bouzerdoum, A. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3729043
“However, they mainly relied on traditional anthropometric instruments, such as calipers and measuring tape, to obtain facial dimensions for RFTP development [6], [7], [8].”
InfluentialOrji, I., Beseler, C. L., Maass, B., Lowe, J., & Nonnenmann, M. (2026) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2026.2722301
Dellagrotta, K., Richards, H., Chang, J., Henderson, T., Kessee, D., Leadon, L., Mathis, J., & Berkheiser, M. L. (2026) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2026.2722261
Metadata
- Authors
- Zhuang, Z., Bradtmiller, B., & Shaffer, R. E.
- Affiliations
- National Institute for Occupational Safety and Health (US)
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2007-07-23
- Volume
- 4
- Issue
- 9
- Pages
- 647-659
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2129506957
- Cited by
- 187
- References
- 16
- Citations by year
- 2026: 13 · 2025: 11 · 2024: 19 · 2023: 12 · 2022: 10 · 2021: 16 · 2020: 15 · 2019: 7 · 2018: 8 · 2017: 12 · 2016: 5 · 2015: 9 · 2014: 6 · 2013: 9 · 2012: 7
- FWCI
- 23.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Performance
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- respirator fit, facial anthropometry, civilian workers, principal component analysis, half-mask respirators, demographics
- MeSH terms
- Anthropometry, Cephalometry, Equipment Design, Face, Female, Humans, Male, National Institute for Occupational Safety and Health, U.S., Respiratory Protective Devices, United States, Occupational Exposure, Inhalation Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.