Some Recent Designs and Developments of Screen‐Printed Carbon Electrochemical Sensors/Biosensors for Biomedical, Environmental, and Industrial Analyses
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
This review describes the design and fabrication of electrochemical sensors/biosensors based on screen-printing technology and their applications in pharmaceutical, biomedical, environmental, and industrial analyses. Specific emphasis is placed on naturally-occurring biomolecules, drugs, and potential environmental and industrial pollutants or toxins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal Nanoparticle-Based Electrochemical Stripping Potentiometric Detection of DNA Hybridization
Wang, J., Xu, D., Kawde, A.-N., & Polsky, R. (2001) · Analytical Chemistry · doi:10.1021/ac0107148 · Cited by 526 · cited 10×
“2,4,6-Trinitrotoluene Wang et al.[77] have described the characterization and performance of SPCEs for the electrochemical measurement of 2,4,6-trinitrotoluene (TNT).”
MethodInfluentialRadic, Z., Pickering, N. A., Vellom, D. C., Camp, S., & Taylor, P. (1993) · Biochemistry · doi:10.1021/bi00096a018 · Cited by 437 · cited 2×
“The substrates and organophosphate inhibitors bind to three distinct binding sites on the enzyme, as described by Radic et al.[98] (1) The size of the acyl pocket determines substrate specificity and mediates sensitivity towards the transition-state analogous inhibitors (organophosphates and carbamates) of different s…”
BackgroundAn Electrochemical Metalloimmunoassay Based on a Colloidal Gold Label
Dequaire, M., Degrand, C., & Limoges, B. (2000) · Analytical Chemistry · doi:10.1021/ac000781m · Cited by 379 · cited 1×
“42 used colloidal gold to label the detection antibody in a heterogeneous non‐competitive immunoassay for IgG.”
MethodRicci, F., Amine, A., Palleschi, G., & Moscone, D. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00169-0 · Cited by 349
PEN-SIZED DIGITAL 30-SECOND BLOOD GLUCOSE METER
Matthews, D. R., Bown, E., Watson, A., Holman, R. R., Steemson, J., Hughes, S., & Scott, D. (1987) · The Lancet · doi:10.1016/s0140-6736(87)92802-9 · Cited by 300 · cited 1×
“2 The large market for this product has prompted numerous other endeavours in a number of diverse areas.”
BackgroundHart, J. P., & Wring, S. A. (1997) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(96)00097-0 · Cited by 280 · cited 3×
“Many research laboratories have developed prototype devices and applied them to a wide variety of applications areas.([1]) The potential of this method of fabrication for the production of commercial devices is exemplified by the personal glucose biosensor used widely by diabetics.”
BackgroundMethodSelf-citationKröger, S., Turner, A. P. F., Mosbach, K., & Haupt, K. (1999) · Analytical Chemistry · doi:10.1021/ac9811827 · Cited by 267 · cited 1×
“A sensor based on a MIP-SPCE has recently been developed for the determination of the herbicide, 2,4-dichlorophenoxyacetic acid (2,4-D).([84]) The SPCEs used in this study were solvent-resistant three electrode systems printed onto polyester sheets, the design and production of which has been previously described by t…”
MethodMarrazza, G., Chianella, I., & Mascini, M. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00102-x · Cited by 237
Disposable DNA electrochemical biosensors for environmental monitoring
Marrazza, G., Chianella, I., & Mascini, M. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00051-3 · Cited by 212 · cited 1×
“This approach has been applied to detection of DNA from Chlamydia trachomatis,([64]) for detection of genetic polymorphisms of Apolipoprotein E in human blood samples([65]) and for geneticallymodified organisms (GMO).”
MethodBiomonitors and Biomarkers as Indicators of Environmental Change 2: A Handbook
(2001) · Springer eBooks · doi:10.1007/978-1-4615-1305-6 · Cited by 206
DNA electrochemical biosensors
Mascini, M., Palchetti, I., & Marrazza, G. (2001) · Fresenius' Journal of Analytical Chemistry · doi:10.1007/s002160000629 · Cited by 204 · cited 1×
“61 62 63 have based their DNA sensors on electrochemical detection of daunomycin, following its intercalation into hybridized double strands on the SPCE surface.”
Prussian Blue bulk modified screen-printed electrodes for H2O2 detection and for biosensors
O'Halloran, M. P., Pravda, M., & Guilbault, G. G. (2001) · Talanta · doi:10.1016/s0039-9140(01)00469-6 · Cited by 196 · cited 2×
“T u rn er [4 9 ]”
Mulchandani, P., Mulchandani, A., Kaneva, I., & Chen, W. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00096-7 · Cited by 191
Bachmann, T. T., Leca‐Bouvier, B. D., Villatte, F., Marty, J., Fournier, D. D., & Schmid, R. D. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00055-5 · Cited by 179 · cited 3×
“SPCE systems have successfully used carbon electrodes crosslinked with AChE using glutaraldehyde([94]) or photocrosslinkable polyvinyl alcohol (PVA).([95]) SPCE modification has been achieved through the addition of electrochemical mediators such as 7,7,8,8-tetracyanoquinodimethane (TCNQ),([92]) hexacyanoferrate (III)…”
MethodInfluentialAzek, F., Grossiord, C., Joannes, M., Limoges, B., & Brossier, P. (2000) · Analytical Biochemistry · doi:10.1006/abio.2000.4692 · Cited by 164 · cited 2×
“[59] Azek et al.[60] used a related approach to detect the presence of human cytomegalovirus (HCMV) DNA in human serum samples, following extraction and polymerase chain reaction (PCR) amplification.”
MethodDetection of Human Apolipoprotein E Genotypes by DNA Electrochemical Biosensor Coupled with PCR
Marrazza, G., Chiti, G., Mascini, M., & Anichini, M. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.1.31 · Cited by 163 · cited 1×
“This approach has been applied to detection of DNA from Chlamydia trachomatis,([64]) for detection of genetic polymorphisms of Apolipoprotein E in human blood samples([65]) and for geneticallymodified organisms (GMO).”
MethodRicci, F., Amine, A., Tuță, C. S., Ciucu, A. A., Lucarelli, F., Palleschi, G., & Moscone, D. (2003) · Analytica Chimica Acta · doi:10.1016/s0003-2670(03)00403-3 · Cited by 137
Separation-free electrochemical immunosensor for rapid determination of atrazine
Keay, R. W., & McNeil, C. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00008-6 · Cited by 131 · cited 2×
“Keay and McNeil([104]) developed a competitive immunoassay incorporating disposable screen-printed HRP-modified carbon electrodes.”
BackgroundNovel electrochemical immunosensors for seafood toxin analysis
Kreuzer, M. P., Pravda, M., O’Sullivan, C. K., & Guilbault, G. G. (2002) · Toxicon · doi:10.1016/s0041-0101(02)00132-0 · Cited by 122 · cited 3×
“Kreuzer et al.[39] described an electrochemical method for IgE based on either competitive or displacement assay formats using SPCEs with surfaceimmobilized anti-IgE antibody, ALP-labeled second antibody and electrochemical detection of 4-aminophenol atþ300mV vs. Ag/AgCl.”
MethodAmperometric biosensors for detection of the prostate cancer marker (PSA)
Sarkar, P., Pal, P. S., Ghosh, D., Setford, S., & Tothill, I. E. (2002) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(02)00015-7 · Cited by 122
Screen Printing of Nucleic Acid Detecting Carbon Electrodes
Dequaire, M., & Heller, A. (2002) · Analytical Chemistry · doi:10.1021/ac025541g · Cited by 112 · cited 2×
“Dequaire and Heller[68] have reported the preparation of SPCEs for DNA detection by cross-linking and electro-depositing a polycationic electronconducting redox polymer onto the surface of screen-printed hydrophilic carbon inks on polyester sheets.”
BackgroundAcetylcholinesterase engineering for detection of insecticide residues
Boublik, Y., Saint-Aguet, P., Brisson-Lougarre, A. A., Arnaud, M., Villatte, F., Estrada‐Mondaca, S., & Fournier, D. D. (2002) · Protein Engineering Design and Selection · doi:10.1093/protein/15.1.43 · Cited by 111 · cited 2×
“For example, Boublik et al.([100]) discovered that a combination of D.”
BackgroundNewman, J. D., White, S. F., Tothill, I. E., & Turner, A. P. F. (1995) · Analytical Chemistry · doi:10.1021/ac00120a027 · Cited by 109 · cited 1×
“This mediator is able to greatly reduce the operating potential, although it is expensive and has a high electrocatalytic activity for many other substances, including reducing sugars.([30]) This drawback necessitates the addition of a perm-selective membrane, and thus complicates the fabrication procedure.”
BackgroundГоголь, Э. В. (2000) · Talanta · doi:10.1016/s0039-9140(00)00507-5 · Cited by 109 · cited 1×
“SPCE systems have successfully used carbon electrodes crosslinked with AChE using glutaraldehyde([94]) or photocrosslinkable polyvinyl alcohol (PVA).”
MethodRemote Biosensor for In-Situ MOnitoring of Organophosphate Nerve Agents
Wang, J., Chen, L., Mulchandani, A., Mulchandani, P., & Chen, W. (1999) · Electroanalysis · doi:10.1002/(sici)1521-4109(199908)11:12<866::aid-elan866>3.0.co;2-1 · Cited by 95 · cited 10×
“2,4,6-Trinitrotoluene Wang et al.[77] have described the characterization and performance of SPCEs for the electrochemical measurement of 2,4,6-trinitrotoluene (TNT).”
MethodInfluentialDisposable tyrosinase-peroxidase bi-enzyme sensor for amperometric detection of phenols
Chang, S., Rawson, K., & McNeil, C. J. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00094-5 · Cited by 90 · cited 1×
“80 The base SPCEs were prepared from a carbon ink, with Ag/AgCl reference and counter electrodes printed onto a 1 mm thick PVC substrate.”
MethodErtl, P., Wagner, M. J., Cortón, E., & Mikkelsen, S. R. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00206-3 · Cited by 79 · cited 1×
“70 have recently reported an electrochemical array method for identification of E.”
MethodVasilescu, A., Noguer, T., Avramescu, M. E., & Marty, J. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01580-x · Cited by 75 · cited 5×
“SPCE based biosensors have been reported for the detection of acetaldehyde[109,110] and D-lactate[110] in wine.”
BackgroundMethodInfluentialChen, L.-Q., Zhang, X., Xie, W., Zhou, Y., Zhang, Z., & Cass, A. E. G. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00051-9 · Cited by 61
Chronoamperometric determination of d-lactate using screen-printed enzyme electrodes
Vasilescu, A., Noguer, T., Magearu, V., & Marty, J. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)01386-6 · Cited by 60 · cited 2×
“@Lactate is an important marker compound in many biomedical, food, and beverage applications. Blood lactate is monitored in exercise control and sports medicine, and D ‐lactate is an indicator of bacterial activity in wine fermentation. 25 26 27 Lactate produced from anaerobic respiration of cattle muscle subsequent t…”
BackgroundDisposable amperometric glucose sensor electrode with enzyme-immobilized nitrocellulose strip
Cui, G. (2001) · Talanta · doi:10.1016/s0039-9140(01)00377-0 · Cited by 60
Simultaneous determination of maltose and glucose using a screen-printed electrode system
Ge, F., Zhang, X., Zhang, Z.-P., & Xiao-Mei, Z. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00122-x · Cited by 50
̆ić, E. T., Kalcher, K., Schachl, K., Komersová, A., Bartos, M., Moderegger, H., Švancara, I., & Vytřas, K. (2001) · Analytical Letters · doi:10.1081/al-100108410 · Cited by 47
LACCASE-BASED SCREEN PRINTED ELECTRODE FOR AMPEROMETRIC DETECTION OF PHENOLIC COMPOUNDS
Freire, R. S., Durán, N., Wang, J., & Kubota, L. T. (2002) · Analytical Letters · doi:10.1081/al-120002359 · Cited by 40 · cited 1×
“A SPCE laccase-based biosensor has recently been reported for monitoring phenolic compounds in environmental samples.([81]) Laccase was immobilized on the electrode surface by simultaneous cross-linking and covalent binding methods.”
BackgroundDisposable potentiometric enzyme sensor for direct determination of organophosphorus insecticides
Gäberlein, S., Knoll, M., Zaborosch, C., & Spener, F. (2000) · The Analyst · doi:10.1039/b006664h · Cited by 37 · cited 2×
“Detection limits for the whole cell system were similar to those achieved for thick-film screen printed electrodes containing 500U of the OPH enzyme by Mulchandani et al.[90] Gäberlein et al.[91] used a disposable Hþ sensitive electrode with a silver carbon ink working electrode using N,N-dioctadecylmethylamine as th…”
MethodWang, J., & Zhang, X. (1999) · Analytical Letters · doi:10.1080/00032719908542929 · Cited by 35
Galán-Vidal, C. A., Muñoz, F. X., Domı́nguez, C., et al. (1998) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(98)00276-7 · Cited by 33 · cited 1×
“It can be seen in Table 1 that potentials of over 1V are required for the oxidation of H2O2 at non-mediated biosensors.([17,18]) Some of the biosensors shown in the same table have used a mediator to re-oxidize the reduced form of GOD [Eq.”
BackgroundCollier, W. A., Lovejoy, P., & Hart, A. L. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00011-0 · Cited by 33 · cited 1×
“The electrochemical mediator described in several recent reports 27 28 29 was platinized carbon.”
BackgroundEstimation of lactate in meat extracts by screen-printed sensors
Hart, A. L., Matthews, C., & Collier, W. A. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00027-6 · Cited by 24
Pravda, M., O'Halloran, M. P., Kreuzer, M. P., & Guilbault, G. G. (2002) · Analytical Letters · doi:10.1081/al-120004548 · Cited by 16
Cited by
Ronkainen, N. J., Halsall, H. B., & Heineman, W. R. (2010) · Chemical Society Reviews · doi:10.1039/b714449k · Cited by 1,945
Gate Dielectrics for Organic Field‐Effect Transistors: New Opportunities for Organic Electronics
Facchetti, A., Yoon, M. ‐., & Marks, T. J. (2005) · Advanced Materials · doi:10.1002/adma.200500517 · Cited by 1,032
Sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
Ricci, F., & Palleschi, G. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.001 · Cited by 781
“An important advantage of screen printed electrodes is that they are inexpensive, simple to prepare, versatile and suitable for the mass-production of disposable electrodes (Albareda-Silvert et al., 2000; Hart et al., 2004).”
InfluentialRecent developments in the field of screen-printed electrodes and their related applications
Renedo, O. D., Alonso-Lomillo, M. A., & Martínez, M. J. A. (2007) · Talanta · doi:10.1016/j.talanta.2007.03.050 · Cited by 647
New directions in screen printed electroanalytical sensors: an overview of recent developments
Metters, J. P., Kadara, R. O., & Banks, C. E. (2011) · The Analyst · doi:10.1039/c0an00894j · Cited by 474
Metadata
- Authors
- Hart, J. P., Crew, A., Crouch, E., Honeychurch, K. C., & Pemberton, R. M.
- Venue
- Analytical Letters
- Publisher
- Informa UK Limited
- Published
- 2004-01
- Volume
- 37
- Issue
- 5
- Pages
- 789-830
- ISSN
- 0003-2719 (ISSN-L)
- 1532-236X
- OpenAlex
- W1995135369
- Cited by
- 229
- References
- 40
- FWCI
- 13.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.