REMOVAL OF ARSENATES FROM CONTAMINATED WATER BY COAGULATION–DIRECT FILTRATION
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The present study has been directed towards the removal of arsenic, applying a modification of conventional coagulation/flocculation process. The modifications refer to the introduction of “pipe flocculation” process in the first stage of the technique, whereas the second step has been performed by direct filtration with sand filters, instead of separation by sedimentation. Alum or ferric chloride was the coagulant agent used, enhanced in certain cases by the presence of cationic or anionic polyelectrolytes (organic polymers). The efficiency of coagulant/polymer addition was investigated, using different ratios and for different initial As(V) concentrations. The effect of linear velocity during sand filtration was also examined. In general, both the coagulants were found to be efficient regarding arsenic removal and in both cases the use of coagulant aids increased the overall efficiency of the method—reaching in some cases arsenic removals up to 99%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the arsenic cycle in natural waters
Ferguson, J. F., & Gavis, J. (1972) · Water Research · doi:10.1016/0043-1354(72)90052-8 · Cited by 1,013
An overview of arsenic removal processes
Kartinen, E. O., & Martin, C. J. (1995) · Desalination · doi:10.1016/0011-9164(95)00089-5 · Cited by 393
Cited by
Arsenic removal from water/wastewater using adsorbents—A critical review
Mohan, D., & Pittman, C. U. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.01.006 · Cited by 3,536
“oagulation/electrocoagulation/coprecipitation: [405,442,479–499] Alum coagulation Durable powder chemicals are ava and simple in operation; effective Iron coagulation Common chemicals are available; coagulation on weigh basis Lime softening Chemicals are available commerc”
BackgroundArsenic toxicity, health hazards and removal techniques from water: an overview
Choong, T. S. Y., Chuah, T. G., Robiah, Y., Gregory Koay, F. L., & Azni, I. (2007) · Desalination · doi:10.1016/j.desal.2007.01.015 · Cited by 912
Removal of arsenic from water by supported nano zero-valent iron on activated carbon
Zhu, H., Jia, Y., Wu, X., & Wang, H. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.08.031 · Cited by 688
Ungureanu, G., Santos, S., Boaventura, R., & Botelho, C. (2015) · Journal of Environmental Management · doi:10.1016/j.jenvman.2014.12.051 · Cited by 660
Roberts, L. C., Hug, S. J., Ruettimann, T., Billah, M. M., Khan, A. W., & Rahman, M. T. (2004) · Environmental Science & Technology · doi:10.1021/es0343205 · Cited by 509
Wang, C., Luo, H., Zhang, Z., Wu, Y., Zhang, J., & Chen, S. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.01.009 · Cited by 389
Application of biological processes for the removal of arsenic from groundwaters
Katsoyiannis, I. A., & Zouboulis, A. I. (2004) · Water Research · doi:10.1016/j.watres.2003.09.011 · Cited by 384
“Several treatment technologies have been applied in the removal of arsenic from waters, such as coagulation/ filtration, ion exchange, lime softening, adsorption on iron oxides or activated alumina and reverse osmosis [10–12].”
MethodSelf-citationBilici Baskan, M., & Pala, A. (2010) · Desalination · doi:10.1016/j.desal.2009.12.016 · Cited by 231
Rathi, B. S., & Kumar, P. S. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.126299 · Cited by 219
Kumari, P., Sharma, P., Srivastava, S., & Srivastava, M. M. (2006) · International Journal of Mineral Processing · doi:10.1016/j.minpro.2005.10.001 · Cited by 209
Removal of arsenic from drinking water using modified natural zeolite
Bilici Baskan, M., & Pala, A. (2011) · Desalination · doi:10.1016/j.desal.2011.08.015 · Cited by 142
“Various technologies are available for the removal of arsenic from contaminated water including chemical precipitation or coagulation, adsorption, lime softening, ion exchange, and membrane separation [21–29].”
BackgroundTresintsi, S., Simeonidis, K., Vourlias, G., Stavropoulos, G., & Mitrakas, M. (2012) · Water Research · doi:10.1016/j.watres.2012.06.049 · Cited by 112
Katsoyiannis, I. A., Zouboulis, A. I., & Jekel, M. (2004) · Industrial & Engineering Chemistry Research · doi:10.1021/ie030525a · Cited by 107
Self-citationEffect of aluminum speciation on arsenic removal during coagulation process
Hu, C., Liu, H., Chen, G., & Qu, J. (2012) · Separation and Purification Technology · doi:10.1016/j.seppur.2011.10.017 · Cited by 104
“The obtained optimum pH range for As(V) removal with Al based coagulants from this study is in good agreement with the values given in literature [5,33,34] .”
ResultKatsoyiannis, I. A., Zikoudi, A., & Hug, S. J. (2008) · Desalination · doi:10.1016/j.desal.2007.06.014 · Cited by 81
Self-citationAndrianisa, H. A., Ito, A., Sasaki, A., Aizawa, J., & Umita, T. (2008) · Water Research · doi:10.1016/j.watres.2008.08.027 · Cited by 75
Metadata
- Authors
- Zouboulis, A., & Katsoyiannis, I.
- Venue
- Separation Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2002-08-26
- Volume
- 37
- Issue
- 12
- Pages
- 2859-2873
- ISSN
- 0149-6395 (ISSN-L)
- 1520-5754
- OpenAlex
- W2058347125
- Cited by
- 122
- References
- 2
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.