CoChat

IEN-CsF1 primary frequency standard at INRIM: accuracy evaluation and TAI calibrations

Levi, F, Calonico, D, Lorini, L, Godone, A · 2006 · Metrologia
Cited by 48

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

In this paper we present an accuracy evaluation of the primary frequency standard IEN-CsF1 of the Italian 'Istituto Nazionale di Ricerca Metrologica'. In particular, we discuss the major improvements applied to the frequency standard that have allowed us to reach a total uncertainty of 8 × 10-16 in a measurement period of 20 days to 25 days. The full metrological chain that links the IEN-CsF1 fountain to the International Atomic Time scale is described and characterized, with respect to its noise and performances.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0026-1394/43/6/010

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 48

Metadata

Authors
Levi, F., Calonico, D., Lorini, L., & Godone, A.
Venue
Metrologia
Published
2006-11-30
Volume
43
Issue
6
Pages
545-555
ISSN
  • 0026-1394 (ISSN-L)
  • 1681-7575
OpenAlex
W1981205509
Cited by
48
References
3
FWCI
2.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: IEN-CsF1 primary frequency standard at INRIM: accuracy evaluation and TAI calibrations. https://app.cochat.ai/papers/10.1088/0026-1394/43/6/010
The paper
Levi, F., Calonico, D., Lorini, L., & Godone, A. (2006). IEN-CsF1 primary frequency standard at INRIM: accuracy evaluation and TAI calibrations. Metrologia. https://doi.org/10.1088/0026-1394/43/6/010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.