A photoelectric plethysmograph for the measurement of cutaneous blood flow
The DOI matches its Crossref record.
Abstract
The photodetector used is a cadmium selenide photoconductive cell and allowance is made for the temperature coefficient of the cell by applying a correction factor. Nonlinearity of the photocell response has been shown to be of negligible importance. Heating of the skin by the light source is greatly reduced by the use of fibre optic light guides and the influence on the recording of changes in oxygenation of haemoglobin is kept to a minimum by an infrared filter. The instrument has been shown to be sensitive, atraumatic and applicable to almost any skin area. Quantitative measurements of blood flow are not possible but accurate comparative measurements of changes in flow are easily obtained when the area of skin under study is compared with an adjacent control area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“However, attempts at pulse amplitude quantification (‘calibration’) have been largely unsuccessful (Hertzman 1938, Challoner and Ramsay 1974, Jespersen and Pedersen 1986, Cejnar et al 1993).”
BackgroundSkin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328
Lu, G., Yang, F., Taylor, J. A., & Stein, J. F. (2009) · Journal of Medical Engineering & Technology · doi:10.3109/03091900903150998 · Cited by 324
The 2023 wearable photoplethysmography roadmap
Charlton, P. H., Allen, J., Bailón, R., Baker, S., Behar, J. A., Chen, F., Clifford, G. D., Clifton, D. A., Davies, H. J., Ding, C., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acead2 · Cited by 187
Chow, H.-W., & Yang, C.-C. (2020) · JMIR mHealth and uHealth · doi:10.2196/14707 · Cited by 140
“PPG measures heart rates based on the changes in vascular blood flow during the cardiac cycle [9].”
Validation of photoplethysmography as a method to detect heart rate during rest and exercise
Spierer, D. K., Rosen, Z., Litman, L. L., & Fujii, K. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1047536 · Cited by 139
“PPG is an optical measurement technique that can be used to detect blood volume changes in the microvascular bed of tissue [35].”
MethodMeasuring venous oxygenation using the photoplethysmograph waveform
Walton, Z. D., Kyriacou, P. A., Silverman, D. G., & Shelley, K. H. (2010) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-010-9248-y · Cited by 53
“For example, the PPG waveform provides characteristic responses to cardiovascular shock [14], sedation [15], and changes in vascular sympathetic tone [16,17].”
BackgroundEvaluating the accuracy of heart rate sensors based on photoplethysmography for in-the-wild analysis
Barrios, L., Oldrati, P., Santini, S., & Lutterotti, A. (2019) · Proceedings of the 13th EAI International Conference on Pervasive Computing Technologies for Healthcare · doi:10.1145/3329189.3329215 · Cited by 43
“PPG is a non-invasive technique for monitoring blood volume changes in the microvascular bed of tissue [8].”
MethodPulsatile and steady-state hemodynamics of the human patella bone by diffuse optical spectroscopy
Farzam, P., Zirak, P., Binzoni, T., & Durduran, T. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/8/839 · Cited by 28
Metadata
- Authors
- Challoner, A. V. J., & Ramsay, C. A.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 1974-05-01
- Volume
- 19
- Issue
- 3
- Pages
- 317-328
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2070638661
- Cited by
- 144
- References
- 0
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.