1H NMR chemical shift selective (CHESS) imaging
The DOI matches its Crossref record.
Abstract
1 H NMR images of human or animal tissues reflect the spatial distribution of both water (H 2 O) and methylene (CH 2 ) proton resonance signals. There are several reasons for a separation of these contributions: (i) the large chemical shift dispersion in high magnetic fields (>or=1.5 T) which leads to an apparent spatial shift in 'composite' images between the superimposed H 2 O and CH 2 images; (ii) the evaluation and interpretation of proton H 2 O and CH 2 relaxation times from NMR images; and (iii) the physiological implications of 'water' and 'fat' distributions for medical diagnosis. The authors describe a chemical shift selective (CHESS) imaging technique which destroys the unwanted signal component by means of a selective 90 degrees excitation pulse and a subsequent magnetic field gradient ('homogeneity spoiling gradient') prior to imaging of the wanted component. The new method allows the creation of either a pure 'water' or 'fat' image.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Simultaneousin vivo spectral editing and water suppression
Mescher, M., Merkle, H., Kirsch, J., Garwood, M., & Gruetter, R. (1998) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199810)11:6<266::aid-nbm530>3.0.co;2-j · Cited by 1,015
Frahm, J., Bruhn, H., Gyngell, M. L., Merboldt, K. D., Hänicke, W., & Sauter, R. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090110 · Cited by 709
Self-citationYu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging
Haase, A. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130109 · Cited by 693
Self-citationThree‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Evidence of Axonal Damage in the Early Stages of Multiple Sclerosis and Its Relevance to Disability
De Stefano, N., Narayanan, S., Francis, G. S., Arnaoutelis, R., Tartaglia, M. C., Antel, J. P., Matthews, P. M., & Arnold, D. L. (2001) · Archives of Neurology · doi:10.1001/archneur.58.1.65 · Cited by 505
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
MR Pulse Sequences: What Every Radiologist Wants to Know but Is Afraid to Ask
Bitar, R., Leung, G., Perng, R., Tadros, S., Moody, A. R., Sarrazin, J., McGregor, C., Christakis, M., Symons, S., Nelson, A., et al. (2006) · RadioGraphics · doi:10.1148/rg.262055063 · Cited by 383
Fat and water magnetic resonance imaging
Bley, T. A., Wieben, O., François, C. J., Brittain, J. H., & Reeder, S. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21895 · Cited by 372
Barzó, P., Marmarou, A., Fatouros, P., Hayasaki, K., & Corwin, F. (1997) · Journal of Neurosurgery · doi:10.3171/jns.1997.87.6.0900 · Cited by 371
Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System
Del Grande, F., Santini, F., Herzka, D. A., Aro, M. R., Dean, C. W., Gold, G. E., & Carrino, J. A. (2014) · RadioGraphics · doi:10.1148/rg.341135130 · Cited by 370
Keshari, K. R., & Wilson, D. M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60124b · Cited by 358
Hernando, D., Kellman, P., Haldar, J. P., & Liang, Z. ‐. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22177 · Cited by 336
Dual‐echo Dixon imaging with flexible choice of echo times
Eggers, H., Brendel, B., Duijndam, A., & Herigault, G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22578 · Cited by 320
Barker, P. B., Soher, B. J., Blackband, S. J., Chatham, J. C., Mathews, V. P., & Bryan, R. N. (1993) · NMR in Biomedicine · doi:10.1002/nbm.1940060114 · Cited by 299
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Quantification of liver iron with MRI: State of the art and remaining challenges
Hernando, D., Levin, Y. S., Sirlin, C. B., & Reeder, S. B. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24584 · Cited by 280
Garnett, M. R. (2000) · Brain · doi:10.1093/brain/123.10.2046 · Cited by 275
In vivo magnetic resonance spectroscopy: basic methodology and clinical applications
van der Graaf, M. (2010) · European Biophysics Journal · doi:10.1007/s00249-009-0517-y · Cited by 275
Quantitative proton MR spectroscopic imaging of the human brain
Soher, B. J., van Zijl, P. C. M., Duyn, J. H., & Barker, P. B. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350313 · Cited by 271
Proton magnetic resonance spectroscopic imaging of human breast cancer: A preliminary study
Jacobs, M. A., Barker, P. B., Bottomley, P. A., Bhujwalla, Z., & Bluemke, D. A. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10427 · Cited by 248
“Water suppression was accomplished with three sequential CHESS pulses with a bandwidth of 75 Hz, applied on-resonance with the water signal (11).”
MethodAutomated single‐voxel proton MRS: Technical development and multisite verification
Webb, P. G., Sailasuta, N., Kohler, S. J., Raidy, T., Moats, R. A., & Hurd, R. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310404 · Cited by 246
“The pulse sequence we used is the stimulated echo (STEAM) sequence (2-7), with chemical-shift-selective [CHESS) water suppression (8, 9).”
MethodCardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
Magnetic resonance imaging with ultrashort TE (UTE) PULSE sequences: Technical considerations
Tyler, D. J., Robson, M. D., Henkelman, R. M., Young, I. R., & Bydder, G. M. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20851 · Cited by 223
Increased Anterior Cingulate/Medial Prefrontal Cortical Glutamate and Creatine in Bipolar Depression
Frye, M. A., Watzl, J., Banakar, S., O'Neill, J., Mintz, J., Davanzo, P., Fischer, J., Chirichigno, J. W., Ventura, J., Elman, S., et al. (2007) · Neuropsychopharmacology · doi:10.1038/sj.npp.1301387 · Cited by 222
“…images (TR/TE¼ 800/ 8 ms, 35 slices, 4 mm thickness with no gap for MRS voxel Neuropsychopharmacology placement, (3) Single-voxel water-suppressed (Haase et al, 1985) PRESS (Bottomley, 1987) 1HMRS (TR/TE¼ 3s/30 ms, number of averages¼ 256, voxel size 3 3 3 cm3) of anterior cingulated/medial…”
Van Zijl, P. C., Moonen, C. T., Faustino, P., Pekar, J., Kaplan, O., & Cohen, J. S. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.8.3228 · Cited by 220
Comparison of single‐shot localization methods (steam and press) for In vivo proton NMR spectroscopy
Moonen, C. T. W., Kienlin, M. V., Van Zijl, P. C. M., Cohen, J., Gillen, J., Daly, P., & Wolf, G. (1989) · NMR in Biomedicine · doi:10.1002/nbm.1940020506 · Cited by 216
Blamire, A. M., Anthony, D. C., Rajagopalan, B., Sibson, N. R., Perry, V. H., & Styles, P. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-21-08153.2000 · Cited by 210
“Suppression of the water signal was achieved using an inversion recovery technique (water-eliminated Fourier transform; Patt and Sykes, 1972) and a chemical shift-selective pulse (Haase et al., 1985) during the TM period.”
MethodSingle‐voxel proton MRS of the human brain at 1.5T and 3.0T
Barker, P. B., Hearshen, D. O., & Boska, M. D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1104 · Cited by 208
MR Spectroscopy and Spectroscopic Imaging of the Brain
Zhu, H., & Barker, P. B. (2011) · Methods in Molecular Biology · doi:10.1007/978-1-61737-992-5_9 · Cited by 208
Magnetic Resonance Neurography
Howe, F. A., Filler, A. G., Bell, B. A., & Griffiths, J. R. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280215 · Cited by 199
Quantitative proton spectroscopy of canine brain: in Vivo and in Vitro correlations
Barker, P. B., Breiter, S. N., Soher, B. J., Chatham, J. C., Forder, J. R., Samphilipo, M. A., Magee, C. A., & Anderson, J. H. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320202 · Cited by 187
Fast image reconstruction with L2‐regularization
Bilgic, B., Chatnuntawech, I., Fan, A. P., Setsompop, K., Cauley, S. F., Wald, L. L., & Adalsteinsson, E. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24365 · Cited by 185
De Stefano, N., Narayanan, S., Francis, S. J., Smith, S., Mortilla, M., Tartaglia, M. C., Bartolozzi, M. L., Guidi, L., Federico, A., & Arnold, D. L. (2002) · Archives of Neurology · doi:10.1001/archneur.59.10.1565 · Cited by 184
“Water suppression was achieved by placing frequency-selective excitation pulses at the beginning of the MRS imaging sequence.(31) Before the water-suppressed acquisition, another MRS image was acquired without water suppression (repetition time, 850 milliseconds; echo time, 272 milliseconds; 250-mm field of view; and…”
MethodOdéen, H., & Parker, D. L. (2019) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2019.01.003 · Cited by 182
On the application of ultra‐fast rare experiments
Norris, D. G., Börnert, P., Reese, T., & Leibfritz, D. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270114 · Cited by 179
Haroon, E., Woolwine, B. J., Chen, X., Pace, T. W., Parekh, S., Spivey, J. R., Hu, X. P., & Miller, A. H. (2014) · Neuropsychopharmacology · doi:10.1038/npp.2014.25 · Cited by 154
Human brain: Proton diffusion MR spectroscopy
Posse, S., Cuenod, C. A., & Le Bihan, D. (1993) · Radiology · doi:10.1148/radiology.188.3.8351339 · Cited by 122
Machann, J., Bachmann, O. P., Brechtel, K., Dahl, D. B., Wietek, B., Klumpp, B., Häring, H., Claussen, C. D., Jacob, S., & Schick, F. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10255 · Cited by 73
“Superior selectivity of frequency-selective excitation compared to inversion recovery or saturation techniques have been described in the literature (21,30), thus being better suited for visualization of low amounts of lipids in human musculature.”
BackgroundIn Vivo Brain GSH: MRS Methods and Clinical Applications
Bottino, F., Lucignani, M., Napolitano, A., Dellepiane, F., Visconti, E., Rossi Espagnet, M. C., & Pasquini, L. (2021) · Antioxidants · doi:10.3390/antiox10091407 · Cited by 50
Krauspe, B. M., Dreher, W., Beyer, C., Baumgartner, W., Denecke, B., Janssen, K., Langhans, C.-D., Clarner, T., & Kipp, M. (2015) · Journal of Molecular Neuroscience · doi:10.1007/s12031-014-0412-6 · Cited by 22
“The dominant water signal was suppressed by three consecutive chemical shift selective saturation pulses (CHESS) (Haase et al., 1985).”
BackgroundMethod
Metadata
- Authors
- Haase, A., Frahm, J., Hanicke, W., & Matthaei, D.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1985-04-01
- Volume
- 30
- Issue
- 4
- Pages
- 341-344
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2000229085
- Cited by
- 1,062
- References
- 0
- FWCI
- 8.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.