The spatial variation of the refractive index in biological cells
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
With a phase microscope the phase shift of cells from type L 929 fibroblast and mitochondria from liver cells was measured. Compared to the total phase shift caused by the cell relative to vacuum (approximately 1400 nm) the single phase shift of the mitochondria (approximately 180 nm) is small. Only the nucleus and the membrane of the cell give a visibly different phase shift relative to the mean value of the cell. The Fraunhofer diffraction of the measured phase object is calculated. With a simplified scattering theory, i.e. Rayleigh-Gans Scattering, different phase objects are investigated and their differential cross section is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light Scattering by Small Particles
van de Hulst, H. C. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,938
New Contributions to the Optics of Intensely Light-Scattering Materials Part I
Kubelka, P. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000448 · Cited by 2,681
Light distributions in artery tissue: Monte Carlo simulations for finite‐diameter laser beams
Keijzer, M., Jacques, S. L., Prahl, S. A., & Welch, A. J. (1989) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900090210 · Cited by 311
Modelling the distribution of laser light in port-wine stains with the Monte Carlo method
Smithies, D. J., & Butler, P. H. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/5/001 · Cited by 67
Ferrari, M. (1993) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2283780 · Cited by 4
Cited by
van der Pol, E., Coumans, F. A. W., Grootemaat, A. E., Gardiner, C., Sargent, I. L., Harrison, P., Sturk, A., van Leeuwen, T. G., & Nieuwland, R. (2014) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12602 · Cited by 917
Speckle in Optical Coherence Tomography
Schmitt, J. M., Xiang, S. H., & Yung, K. M. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429925 · Cited by 837
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 681
Rappaz, B., Marquet, P., Cuche, E., Emery, Y., Depeursinge, C., & Magistretti, P. J. (2005) · Optics Express · doi:10.1364/opex.13.009361 · Cited by 674
Time-resolved fluorescence microscopy
Suhling, K., French, P. M. W., & Phillips, D. (2005) · Photochemical & Photobiological Sciences · doi:10.1039/b412924p · Cited by 548
Perelman, L. T., Backman, V., Wallace, M., Zonios, G., Manoharan, R., Nusrat, A., Shields, S., Seiler, M., Lima, C., Hamano, T., et al. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.627 · Cited by 491
Müller cells are living optical fibers in the vertebrate retina
Franze, K., Grosche, J., Skatchkov, S. N., Schinkinger, S., Foja, C., Schild, D., Uckermann, O., Travis, K., Reichenbach, A., & Guck, J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611180104 · Cited by 426
Single vs. swarm detection of microparticles and exosomes by flow cytometry
Van Der POL, E., Van GEMERT, M. J. C., STURK, A., NIEUWLAND, R., & Van LEEUWEN, T. G. (2012) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2012.04683.x · Cited by 421
Optical scattering properties of soft tissue: a discrete particle model
Schmitt, J. M., & Kumar, G. (1998) · Applied Optics · doi:10.1364/ao.37.002788 · Cited by 408
Resonant Waveguide Grating Biosensor for Living Cell Sensing
Fang, Y., Ferrie, A. M., Fontaine, N. H., Mauro, J., & Balakrishnan, J. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.077818 · Cited by 383
Investigation of living pancreas tumor cells by digital holographic microscopy
Kemper, B., Carl, D., Schnekenburger, J., Bredebusch, I., Schäfer, M., Domschke, W., & von Bally, G. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2204609 · Cited by 364
Susaki, E. A., & Ueda, H. R. (2016) · Cell Chemical Biology · doi:10.1016/j.chembiol.2015.11.009 · Cited by 295
Mueller polarimetric imaging for surgical and diagnostic applications: a review
Qi, J., & Elson, D. S. (2017) · Journal of Biophotonics · doi:10.1002/jbio.201600152 · Cited by 268
Light scattering from cells: the contribution of the nucleus and the effects of proliferative status
Mourant, J. R., Canpolat, M., Brocker, C., Esponda-Ramos, O., Johnson, T. M., Matanock, A., Stetter, K., & Freyer, J. P. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429979 · Cited by 261
Imaging the Environment of Green Fluorescent Protein
Suhling, K., Siegel, J., Phillips, D., French, P. M. W., Lévêque-Fort, S., Webb, S. E. D., & Davis, D. M. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75359-9 · Cited by 252
Gardiner, C., Shaw, M., Hole, P., Smith, J., Tannetta, D., Redman, C. W., & Sargent, I. L. (2014) · Journal of Extracellular Vesicles · doi:10.3402/jev.v3.25361 · Cited by 186
“the nucleus), which differ in RI as demonstrated by phase contrast microscopy (6).”
Johnsen, S., & Widder, E. A. (1999) · Journal of Theoretical Biology · doi:10.1006/jtbi.1999.0948 · Cited by 140
“…in this "eld are primarily interested in either correlating the scattering properties of tissue with various disorders or in determining the distance that (therapeutic) light will penetrate into a tissue (Wilson et al., 1987; Beauvoit et al., 1995, Beuthan et al., 1996; Mourant et al., 1998).”
BackgroundPolarized light imaging of white matter architecture
Larsen, L., Griffin, L. D., GRäßel, D., Witte, O. W., & Axer, H. (2007) · Microscopy Research and Technique · doi:10.1002/jemt.20488 · Cited by 96
Metadata
- Authors
- Beuthan, J., Minet, O., Helfmann, J., Herrig, M., & Müller, G.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1996-03-01
- Volume
- 41
- Issue
- 3
- Pages
- 369-382
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2009663935
- Cited by
- 316
- References
- 5
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.