Optical imaging in medicine: I. Experimental techniques
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The overwhelming scatter which occurs when optical radiation propagates through tissue severely limits the ability to image internal structure using measurements of transmitted intensity. A broad range of methods has been proposed during the past decade or so in order to improve imaging performance. Direct methods involve isolating an unscattered or least-scattered component of transmitted scattered light. Indirect methods generally involve measuring some characteristic of the temporal distribution of transmitted light, or an equivalent in the frequency domain, and obtaining a computational solution to the inverse problem. In this paper, we review the experimental techniques which have been proposed in order to explore both direct and indirect imaging. The relative merits and limitations of the various experimental methods are discussed, and we consider the future directions and likelihood of success of optical imaging in medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Self-citationCope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Self-citationBallistic 2-D Imaging Through Scattering Walls Using an Ultrafast Optical Kerr Gate
Wang, L., Ho, P. P., Liu, C., Zhang, G., & Alfano, R. R. (1991) · Science · doi:10.1126/science.253.5021.769 · Cited by 552
Optical imaging in medicine: II. Modelling and reconstruction
Arridge, S. R., & Hebden, J. C. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/008 · Cited by 495
Self-citationExperimental images of heterogeneous turbid media by frequency-domain diffusing-photon tomography
O’Leary, M. A., Boas, D. A., Chance, B., & Yodh, A. G. (1995) · Optics Letters · doi:10.1364/ol.20.000426 · Cited by 440
Fishkin, J. B., & Gratton, E. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.000127 · Cited by 385
Polarization memory of multiply scattered light
MacKintosh, F. C., Zhu, J. X., Pine, D. J., & Weitz, D. A. (1989) · Physical Review B · doi:10.1103/physrevb.40.9342 · Cited by 370
Cited by
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
Self-citationIn vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Self-citationNon-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903
Tissue polarimetry: concepts, challenges, applications, and outlook
Ghosh, N. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3652896 · Cited by 740
Imaging the body with diffuse optical tomography
Boas, D. A., Brooks, D. H., Miller, E. L., DiMarzio, C. A., Kilmer, M., Gaudette, R. J., & Zhang, Q. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962278 · Cited by 718
Optical tomography: forward and inverse problems
Arridge, S. R., & Schotland, J. C. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123010 · Cited by 625
Self-citationProgress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Optical imaging in medicine: II. Modelling and reconstruction
Arridge, S. R., & Hebden, J. C. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/008 · Cited by 495
Self-citationNonuniqueness in diffusion-based optical tomography
Arridge, S. R., & Lionheart, W. R. B. (1998) · Optics Letters · doi:10.1364/ol.23.000882 · Cited by 336
Self-citationHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Oxyphor R2 and G2: phosphors for measuring oxygen by oxygen-dependent quenching of phosphorescence
Dunphy, I., Vinogradov, S. A., & Wilson, D. F. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00384-6 · Cited by 288
Some applications of persistent random walks and the telegrapher's equation
Weiss, G. H. (2002) · Physica A: Statistical Mechanics and its Applications · doi:10.1016/s0378-4371(02)00805-1 · Cited by 278
Okada, E., & Delpy, D. T. (2003) · Applied Optics · doi:10.1364/ao.42.002906 · Cited by 274
Self-citationA 32-channel time-resolved instrument for medical optical tomography
Schmidt, F. E. W., Fry, M. E., Hillman, E. M. C., Hebden, J. C., & Delpy, D. T. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150191 · Cited by 260
Self-citationChitosan-based systems for molecular imaging
Agrawal, P., Strijkers, G. J., & Nicolay, K. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.09.007 · Cited by 250
Combined Optical and X-ray Tomosynthesis Breast Imaging
Fang, Q., Selb, J., Carp, S. A., Boverman, G., Miller, E. L., Brooks, D. H., Moore, R. H., Kopans, D. B., & Boas, D. A. (2011) · Radiology · doi:10.1148/radiol.10082176 · Cited by 207
Gauss–Newton method for image reconstruction in diffuse optical tomography
Schweiger, M., Arridge, S. R., & Nissilä, I. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/10/013 · Cited by 206
“…type of solutions being sought, the physical model assumed for light propagation, and in the algorithmic details; for reviews see Arridge (1993, 1999), Yodh and Chance (1995), Hebden et al (1997), Arridge and Hebden (1997), Hawysz and Sevick-Muraca (2000), Boas et al (2001) and Gibson et al (2005).”
BackgroundSelf-citationOptical biopsy: A new frontier in endoscopic detection and diagnosis
Wang, T. D., & Van Dam, J. (2004) · Clinical Gastroenterology and Hepatology · doi:10.1016/s1542-3565(04)00345-3 · Cited by 202
Brooksby, B. A., Dehghani, H., Pogue, B. W., & Paulsen, K. D. (2003) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2003.813304 · Cited by 174
“An optical fiber on the tissue surface delivers an optical signal [either continuous wave (CW) [19], amplitude modulated [20], or ultra short pulses [21]] and other fibers located on the tissue surface pass transmitted photons to some well-developed light-detection device [ 21 ].”
BackgroundQuality control and assurance in functional near infrared spectroscopy (fNIRS) experimentation
Orihuela-Espina, F., Leff, D. R., James, D. R. C., Darzi, A. W., & Yang, G. Z. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/13/009 · Cited by 164
“The theory or model adopted to solve this inverse problem varies according to the imaging modality and requires a trade-off between assumptions made, complexity and computational burden (Arridge et al 1997, Hebden et al 1997, Dehghani et al 2009a).”
MethodHigher-Order Brain Function Analysis by Trans-Cranial Dynamic Near-Infrared Spectroscopy Imaging
Koizumi, H., Yamashita, Y., Maki, A., Yamamoto, T., Ito, Y., Itagaki, H., & Kennan, R. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429959 · Cited by 164
Image reconstruction in optical tomography
Arridge, S. R., & Schweiger, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0054 · Cited by 160
“This paper is of the nature of a review, but since we have recently published quite detailed reviews of both measurement techniques (Hebden & Arridge 1997), and modelling and reconstruction (Arridge & Hebden 1997) some of the more detailed comparison is truncated, with the reader referred to these…”
MethodSelf-citationGibson, A., & Dehghani, H. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0080 · Cited by 159
Near‐Infrared Diffuse Optical Tomography
Hielscher, A. H., Bluestone, A. Y., Abdoulaev, G. S., Klose, A. D., Lasker, J., Stewart, M., Netz, U., & Beuthan, J. (2002) · Disease Markers · doi:10.1155/2002/164252 · Cited by 159
Metadata
- Authors
- Hebden, J. C., Arridge, S. R., & Delpy, D. T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1997-05-01
- Volume
- 42
- Issue
- 5
- Pages
- 825-840
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2051492340
- Cited by
- 402
- References
- 26
- FWCI
- 18.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.