Abstract
The overwhelming scatter which occurs when optical radiation propagates through tissue severely limits the ability to image internal structure using measurements of transmitted intensity. A broad range of methods has been proposed during the past decade or so in order to improve imaging performance. Direct methods involve isolating an unscattered or least-scattered component of transmitted scattered light. Indirect methods generally involve measuring some characteristic of the temporal distribution of transmitted light, or an equivalent in the frequency domain, and obtaining a computational solution to the inverse problem. In this paper, we review the experimental techniques which have been proposed in order to explore both direct and indirect imaging. The relative merits and limitations of the various experimental methods are discussed, and we consider the future directions and likelihood of success of optical imaging in medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Self-citationCope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Self-citationBallistic 2-D Imaging Through Scattering Walls Using an Ultrafast Optical Kerr Gate
Wang, L., Ho, P. P., Liu, C., Zhang, G., & Alfano, R. R. (1991) · Science · doi:10.1126/science.253.5021.769 · Cited by 552
Optical imaging in medicine: II. Modelling and reconstruction
Arridge, S. R., & Hebden, J. C. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/008 · Cited by 495
Self-citationExperimental images of heterogeneous turbid media by frequency-domain diffusing-photon tomography
O’Leary, M. A., Boas, D. A., Chance, B., & Yodh, A. G. (1995) · Optics Letters · doi:10.1364/ol.20.000426 · Cited by 440
Fishkin, J. B., & Gratton, E. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.000127 · Cited by 385
Polarization memory of multiply scattered light
MacKintosh, F. C., Zhu, J. X., Pine, D. J., & Weitz, D. A. (1989) · Physical Review B · doi:10.1103/physrevb.40.9342 · Cited by 370
Matcher, S. J., Cope, M., & Delpy, D. T. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/1/011 · Cited by 323
Self-citationUse of polarized light to discriminate short-path photons in a multiply scattering medium
Schmitt, J. M., Gandjbakhche, A. H., & Bonner, R. F. (1992) · Applied Optics · doi:10.1364/ao.31.006535 · Cited by 292
High-resolution optical coherence tomographic imaging using a mode-locked Ti:Al_2O_3 laser source
Bouma, B., Brezinski, M. E., Fujimoto, J. G., Tearney, G. J., Boppart, S. A., & Hee, M. R. (1995) · Optics Letters · doi:10.1364/ol.20.001486 · Cited by 283
Optical Time-of-Flight and Absorbance Imaging of Biologic Media
Benaron, D. A., & Stevenson, D. K. (1993) · Science · doi:10.1126/science.8451643 · Cited by 230
Femtosecond transillumination optical coherence tomography
Hee, M. R., Swanson, E. A., Izatt, J. A., Jacobson, J. M., & Fujimoto, J. G. (1993) · Optics Letters · doi:10.1364/ol.18.000950 · Cited by 182
Yoo, K. M., Xing, Q., & Alfano, R. R. (1991) · Optics Letters · doi:10.1364/ol.16.001019 · Cited by 164
(1993) · SPIE Proceedings · doi:10.1117/12.2283746 · Cited by 163
Time-gated transillumination of biological tissues and tissuelike phantoms
Mitić, G., Kölzer, J., Otto, J., Plies, E., Sölkner, G., & Zinth, W. (1994) · Applied Optics · doi:10.1364/ao.33.006699 · Cited by 133
Femtosecond transillumination tomography in thick tissues
Hee, M. R., Swanson, E. A., Fujimoto, J. G., & Izatt, J. A. (1993) · Optics Letters · doi:10.1364/ol.18.001107 · Cited by 94
Transmission of a pulsed polarized light beam through thick turbid media: numerical results
Bruscaglioni, P., Zaccanti, G., & Wei, Q. (1993) · Applied Optics · doi:10.1364/ao.32.006142 · Cited by 83
Evaluating the spatial resolution performance of a time-resolved optical imaging system
Hebden, J. C. (1992) · Medical Physics · doi:10.1118/1.596826 · Cited by 74
Self-citationTime-resolved Fourier spectrum and imaging in highly scattering media
Wang, L., Ho, P. P., & Alfano, R. R. (1993) · Applied Optics · doi:10.1364/ao.32.005043 · Cited by 60
A novel approach to laser tomography
Gratton, E., Mantulin, W. W., vandeVen, M., Fishkin, J. B., Maris, M. B., & Chance, B. (1993) · Bioimaging · doi:10.1002/1361-6374(199303)1:1<40::aid-bio7>3.3.co;2-m · Cited by 59
Upconverting time gate for imaging through highly scattering media
Faris, G. W., & Banks, M. (1994) · Optics Letters · doi:10.1364/ol.19.001813 · Cited by 53
Frequency domain imaging of absorbers obscured by scattering
Sevick, E., Lakowicz, J. R., Szmacinski, H., Nowaczyk, K., & Johnson, M. L. (1992) · Journal of Photochemistry and Photobiology B Biology · doi:10.1016/1011-1344(92)80007-i · Cited by 50
Imaging in diffuse media with ultrafast degenerate optical parametric amplification
Watson, J. M., Georges, P., Lépine, T., et al. (1995) · Optics Letters · doi:10.1364/ol.20.000231 · Cited by 38
Cited by
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
Self-citationIn vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Self-citationNon-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903
Metadata
- Authors
- Hebden, J. C., Arridge, S. R., & Delpy, D. T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1997-05-01
- Volume
- 42
- Issue
- 5
- Pages
- 825-840
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2051492340
- Cited by
- 402
- References
- 26
- FWCI
- 18.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.