Abstract
The desire for a diagnostic optical imaging modality has motivated the development of image reconstruction procedures involving solution of the inverse problem. This approach is based on the assumption that, given a set of measurements of transmitted light between pairs of points on the surface of an object, there exists a unique three-dimensional distribution of internal scatterers and absorbers which would yield that set. Thus imaging becomes a task of solving an inverse problem using an appropriate model of photon transport. In this paper we examine the models that have been developed for this task, and review current approaches to image reconstruction. Specifically, we consider models based on radiative transfer theory and its derivatives, which are either stochastic in nature (random walk, Monte Carlo, and Markov processes) or deterministic (partial differential equation models and their solutions). Image reconstruction algorithms are discussed which are based on either direct backprojection, perturbation methods, nonlinear optimization, or Jacobian calculation. Finally we discuss some of the fundamental problems that must be addressed before optical tomography can be considered to be an understood problem, and before its full potential can be realized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Case, K. M., Zweifel, P. F., & Pomraning, G. C. (1968) · Physics Today · doi:10.1063/1.3034554 · Cited by 1,609
Duderstadt, J. J., & Hamilton, L. J. (1976) · Deep Blue (University of Michigan) · Cited by 1,603
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
A Monte Carlo model for the absorption and flux distributions of light in tissue
Wilson, B. C., & Adam, G. (1983) · Medical Physics · doi:10.1118/1.595361 · Cited by 690
A finite element approach for modeling photon transport in tissue
Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T. (1993) · Medical Physics · doi:10.1118/1.597069 · Cited by 635
Self-citationArridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Self-citationMultiple Scattering in an Infinite Medium
Lewis, H. W. (1950) · Physical Review · doi:10.1103/physrev.78.526 · Cited by 472
Cited by
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
Self-citationFerrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
“This is termed the inverse problem (for reviews: Arridge, 2011; Arridge and Hebden, 1997; Boas et al., 2001a).”
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Self-citationFLUORESCENCE MOLECULAR IMAGING
Ntziachristos, V. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095831 · Cited by 731
Optical tomography: forward and inverse problems
Arridge, S. R., & Schotland, J. C. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123010 · Cited by 625
Self-citationProgress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
The Accuracy of Near Infrared Spectroscopy and Imaging during Focal Changes in Cerebral Hemodynamics
Boas, D. A., Gaudette, T., Strangman, G., Cheng, X., Marota, J. J. A., & Mandeville, J. B. (2001) · NeuroImage · doi:10.1006/nimg.2000.0674 · Cited by 459
Optical imaging in medicine: I. Experimental techniques
Hebden, J. C., Arridge, S. R., & Delpy, D. T. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/007 · Cited by 402
Self-citationOkada, E., & Delpy, D. T. (2003) · Applied Optics · doi:10.1364/ao.42.002915 · Cited by 364
Nonuniqueness in diffusion-based optical tomography
Arridge, S. R., & Lionheart, W. R. B. (1998) · Optics Letters · doi:10.1364/ol.23.000882 · Cited by 336
Self-citationBulk optical properties of healthy female breast tissue
Durduran, T., Choe, R., Culver, J. P., Zubkov, L., Holboke, M. J., Giammarco, J., Chance, B., & Yodh, A. G. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/16/302 · Cited by 291
Some applications of persistent random walks and the telegrapher's equation
Weiss, G. H. (2002) · Physica A: Statistical Mechanics and its Applications · doi:10.1016/s0378-4371(02)00805-1 · Cited by 278
A 32-channel time-resolved instrument for medical optical tomography
Schmidt, F. E. W., Fry, M. E., Hillman, E. M. C., Hebden, J. C., & Delpy, D. T. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150191 · Cited by 260
Self-citationChitosan-based systems for molecular imaging
Agrawal, P., Strijkers, G. J., & Nicolay, K. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.09.007 · Cited by 250
Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues
Tzoumas, S., Nunes, A., Olefir, I., Stangl, S., Symvoulidis, P., Glasl, S., Bayer, C., Multhoff, G., & Ntziachristos, V. (2016) · Nature Communications · doi:10.1038/ncomms12121 · Cited by 248
Combined Optical and X-ray Tomosynthesis Breast Imaging
Fang, Q., Selb, J., Carp, S. A., Boverman, G., Miller, E. L., Brooks, D. H., Moore, R. H., Kopans, D. B., & Boas, D. A. (2011) · Radiology · doi:10.1148/radiol.10082176 · Cited by 207
Gauss–Newton method for image reconstruction in diffuse optical tomography
Schweiger, M., Arridge, S. R., & Nissilä, I. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/10/013 · Cited by 206
“Image reconstruction methods in optical tomography differ in the type of data being considered, the type of solutions being sought, the physical model assumed for light propagation, and in the algorithmic details; for reviews see Arridge (1993, 1999), Yodh and Chance (1995), Hebden et al (1997), Arridge and Hebden (19…”
BackgroundMethodSelf-citationJermyn, M., Ghadyani, H., Mastanduno, M. A., Turner, W., Davis, S. C., Dehghani, H., & Pogue, B. W. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.8.086007 · Cited by 186
Quality control and assurance in functional near infrared spectroscopy (fNIRS) experimentation
Orihuela-Espina, F., Leff, D. R., James, D. R. C., Darzi, A. W., & Yang, G. Z. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/13/009 · Cited by 164
Higher-Order Brain Function Analysis by Trans-Cranial Dynamic Near-Infrared Spectroscopy Imaging
Koizumi, H., Yamashita, Y., Maki, A., Yamamoto, T., Ito, Y., Itagaki, H., & Kennan, R. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429959 · Cited by 164
Unmixing Molecular Agents From Absorbing Tissue in Multispectral Optoacoustic Tomography
Tzoumas, S., Deliolanis, N., Morscher, S., & Ntziachristos, V. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2279994 · Cited by 160
Image reconstruction in optical tomography
Arridge, S. R., & Schweiger, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0054 · Cited by 160
“…of a review, but since we have recently published quite detailed reviews of both measurement techniques (Hebden & Arridge 1997), and modelling and reconstruction (Arridge & Hebden 1997) some of the more detailed comparison is truncated, with the reader referred to these articles for more details.”
MethodSelf-citationGibson, A., & Dehghani, H. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0080 · Cited by 159
Metadata
- Authors
- Arridge, S. R., & Hebden, J. C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1997-05-01
- Volume
- 42
- Issue
- 5
- Pages
- 841-853
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2026592776
- Cited by
- 495
- References
- 21
- FWCI
- 23.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.