Ordered subsets algorithms for transmission tomography
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The ordered subsets EM (OSEM) algorithm has enjoyed considerable interest for emission image reconstruction due to its acceleration of the original EM algorithm and ease of programming. The transmission EM reconstruction algorithm converges very slowly and is not used in practice. In this paper, we introduce a simultaneous update algorithm called separable paraboloidal surrogates (SPS) that converges much faster than the transmission EM algorithm. Furthermore, unlike the 'convex algorithm' for transmission tomography, the proposed algorithm is monotonic even with nonzero background counts. We demonstrate that the ordered subsets principle can also be applied to the new SPS algorithm for transmission tomography to accelerate 'convergence', albeit with similar sacrifice of global convergence properties as for OSEM. We implemented and evaluated this ordered subsets transmission (OSTR) algorithm. The results indicate that the OSTR algorithm speeds up the increase in the objective function by roughly the number of subsets in the early iterates when compared to the ordinary SPS algorithm. We compute mean square errors and segmentation errors for different methods and show that OSTR is superior to OSEM applied to the logarithm of the transmission data. However, penalized-likelihood reconstructions yield the best quality images among all other methods tested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
Space-alternating generalized expectation-maximization algorithm
Fessler, J. A., & Hero, A. O. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.324732 · Cited by 1,063
Self-citationPenalized weighted least-squares image reconstruction for positron emission tomography
Fessler, J. A. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293921 · Cited by 611
Self-citationA local update strategy for iterative reconstruction from projections
Sauer, K., & Bouman, C. (1993) · IEEE Transactions on Signal Processing · doi:10.1109/78.193196 · Cited by 494
De Pierro, A. R. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370409 · Cited by 475
A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography
Browne, J., & de Pierro, A. B. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538946 · Cited by 424
Convergence of EM image reconstruction algorithms with Gibbs smoothing
Lange, K. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.61759 · Cited by 400
Monotonic algorithms for transmission tomography
Erdogan, H., & Fessler, J. A. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.802758 · Cited by 351
Self-citationGlobally convergent algorithms for maximum a posteriori transmission tomography
Lange, K., & Fessler, J. A. (1995) · IEEE Transactions on Image Processing · doi:10.1109/83.465107 · Cited by 313
Self-citation
Cited by
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
Iterative reconstruction methods in X-ray CT
Beister, M., Kolditz, D., & Kalender, W. A. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.01.003 · Cited by 751
Statistical image reconstruction for polyenergetic X-ray computed tomography
Elbakri, I. A., & Fessler, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993128 · Cited by 691
Self-citationWillemink, M. J., & Noël, P. B. (2019) · European Radiology · doi:10.1007/s00330-018-5810-7 · Cited by 603
Lin, F., Liu, Y., Yu, X., Cheng, L., Singer, A., Shpyrko, O. G., Xin, H. L., Tamura, N., Tian, C., Weng, T.-C., et al. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00007 · Cited by 582
Pan, X., Sidky, E. Y., & Vannier, M. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123009 · Cited by 572
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Kinahan, P. E., Hasegawa, B. H., & Beyer, T. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127307 · Cited by 515
Technical aspects of dental CBCT: state of the art
Pauwels, R., Araki, K., Siewerdsen, J. H., & Thongvigitmanee, S. S. (2015) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20140224 · Cited by 510
STIR: software for tomographic image reconstruction release 2
Thielemans, K., Tsoumpas, C., Mustafovic, S., Beisel, T., Aguiar, P., Dikaios, N., & Jacobson, M. W. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/4/867 · Cited by 466
Sidky, E. Y., Jørgensen, J. H., & Pan, X. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/10/3065 · Cited by 360
Ahn, S., & Fessler, J. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.812251 · Cited by 344
Self-citationLow‐dose CT image and projection dataset
Moen, T. R., Chen, B., Holmes, D. R., Duan, X., Yu, Z., Yu, L., Leng, S., Fletcher, J. G., & McCollough, C. H. (2021) · Medical Physics · doi:10.1002/mp.14594 · Cited by 287
Tang, J., Nett, B. E., & Chen, G.-H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/008 · Cited by 282
A Splitting-Based Iterative Algorithm for Accelerated Statistical X-Ray CT Reconstruction
Ramani, S., & Fessler, J. A. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2175233 · Cited by 257
Self-citationStatistical Image Reconstruction Methods for Transmission Tomography
Fessler, J. (2010) · Handbook of Medical Imaging, Volume 2. Medical Image Processing and Analysis · doi:10.1117/3.831079.ch1 · Cited by 240
Self-citationIncremental Majorization-Minimization Optimization with Application to Large-Scale Machine Learning
Mairal, J. (2015) · SIAM Journal on Optimization · doi:10.1137/140957639 · Cited by 232
“Majorizing surrogates have also been used successfully in the signal processing literature about sparse estimation [11, 16, 26], linear inverse problems in image processing [1, 23], and matrix factorization [37, 40].”
MethodPenalized PET Reconstruction Using Deep Learning Prior and Local Linear Fitting
Kim, K., Wu, D., Gong, K., Dutta, J., Kim, J. H., Son, Y. D., Kim, H. K., El Fakhri, G., & Li, Q. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2832613 · Cited by 194
“To minimize the cost function, we use a majorizer of L(x) using separable quadratic surrogates (SQS) [12]: L(x) ≤ φ(n)L (x) N∑ j=1 φ (n) L , j (x j ), (10) and φ (n) L , j (x j ) M∑ i=1 gi j p (n) i ( ai j gi j (x j − x (n)j ) + [Ax (n)]i ) , (11) where gi j = ai j∑N j ′=1 ai j ′ is a non-negative real value (gi j = 0…”
InfluentialIterative image reconstruction for CBCT using edge‐preserving prior
Wang, J., Li, T., & Xing, L. (2009) · Medical Physics · doi:10.1118/1.3036112 · Cited by 188
Compressive sensing in medical imaging
Graff, C. G., & Sidky, E. Y. (2015) · Applied Optics · doi:10.1364/ao.54.000c23 · Cited by 184
“The ordered subsets for transmission tomography (OSTR) [79] also use the sequential processing strategy and can be applied to the TV-based optimization problems.”
MethodWu, J., Wang, X., Mou, X., Chen, Y., & Liu, S. (2020) · Sensors · doi:10.3390/s20061647 · Cited by 9
“To further accelerate updating Equation (10), we adopt order subset (OS) methods [29], by grouping the projection views into M subsets evenly and using only the subset of measured data to approximate the exact gradient of the cost function.”
Method
Metadata
- Authors
- Erdogan, H., & Fessler, J. A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1999-10-20
- Volume
- 44
- Issue
- 11
- Pages
- 2835-2851
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2032237670
- Cited by
- 556
- References
- 15
- FWCI
- 7.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.