Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility study
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
The feasibility and limits in performing tomographic bioluminescence imaging with a combined optical-PET (OPET) system were explored by simulating its image formation process. A micro-MRI based virtual mouse phantom was assigned appropriate tissue optical properties to each of its segmented internal organs at wavelengths spanning the emission spectrum of the firefly luciferase at 37 degrees C. The TOAST finite-element code was employed to simulate the diffuse transport of photons emitted from bioluminescence sources in the mouse. OPET measurements were simulated for single-point, two-point and distributed bioluminescence sources located in different organs such as the liver, the kidneys and the gut. An expectation maximization code was employed to recover the intensity and location of these simulated sources. It was found that spectrally resolved measurements were necessary in order to perform tomographic bioluminescence imaging. The true location of emission sources could be recovered if the mouse background optical properties were known a priori. The assumption of a homogeneous optical property background proved inadequate for describing photon transport in optically heterogeneous tissues and led to inaccurate source localization in the reconstructed images. The simulation results pointed out specific methodological challenges that need to be addressed before a practical implementation of OPET-based bioluminescence tomography is achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Physiological Parameter Values for Physiologically Based Pharmacokinetic Models
Brown, R. P., Delp, M. D., Lindstedt, S. L., Rhomberg, L. R., & Beliles, R. P. (1997) · Toxicology and Industrial Health · doi:10.1177/074823379701300401 · Cited by 1,415
A finite element approach for modeling photon transport in tissue
Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T. (1993) · Medical Physics · doi:10.1118/1.597069 · Cited by 635
A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors
Hebert, T., & Leahy, R. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.24868 · Cited by 622
Boas, D. A., Culver, J. P., Stott, J. J., & Dunn, A. K. (2002) · Optics Express · doi:10.1364/oe.10.000159 · Cited by 599
Bioluminescent indicators in living mammals
Contag, P. R., Olomu, I. N., Stevenson, D. K., & Contag, C. H. (1998) · Nature Medicine · doi:10.1038/nm0298-245 · Cited by 517
Kienle, A., Lilge, L., Patterson, M. S., Hibst, R., Steiner, R., & Wilson, B. C. (1996) · Applied Optics · doi:10.1364/ao.35.002304 · Cited by 495
Development of a 4-D digital mouse phantom for molecular imaging research
SEGARS, W. (2004) · Molecular Imaging & Biology · doi:10.1016/j.mibio.2004.03.002 · Cited by 420
Troy, T., Jekic-McMullen, D., Sambucetti, L., & Rice, B. (2004) · Molecular Imaging · doi:10.1162/153535004773861688 · Cited by 418 · cited 3×
“However, most bioluminescence probes currently in use emit the bulk of their optical signal at green wavelengths and are therefore attenuated very strongly if they are located deep in tissues (Troy et al 2004).”
BackgroundMethodInfluentialDoornbos, R. M. P., Lang, R., Aalders, M. C., Cross, F. W., & Sterenborg, H. J. C. M. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/4/012 · Cited by 380
Imaging tri-fusion multimodality reporter gene expression in living subjects
Ray, P., De, A., Min, J.-J., Tsien, R. Y., & Gambhir, S. S. (2004) · Cancer Research · doi:10.1158/0008-5472.can-03-1816 · Cited by 329 · cited 1×
“New PET tracers that allow monitoring of previously inaccessible physiological processes or simply ones that confer increased specificity of detection in small animals can subsequently be tested on humans in the clinic without modification (Ray et al 2004).”
BackgroundPerformance evaluation of the microPET P4: a PET system dedicated to animal imaging
Tai, Y. C., Chatziioannou, A., Siegel, S., Young, J., Newport, D., Goble, R. N., Nutt, R. E., & Cherry, S. R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/7/308 · Cited by 308
Self-citationMeasurement of the optical properties of the skull in the wavelength range 650-950 nm
Firbank, M., Hiraoka, M., Essenpreis, M., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/4/002 · Cited by 305
Uniqueness theorems in bioluminescence tomography
Wang, G., Li, Y., & Jiang, M. (2004) · Medical Physics · doi:10.1118/1.1766420 · Cited by 299
Srinivasan, S., Pogue, B. W., Jiang, S., Dehghani, H., Kogel, C., Soho, S., Gibson, J. J., Tosteson, T. D., Poplack, S. P., & Paulsen, K. D. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2032822100 · Cited by 267
Molecular imaging of small animals with dedicated PET tomographs
Chatziioannou, A. F. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0683-3 · Cited by 265
Self-citationModeling optical and thermal distributions in tissue during laser irradiation
Jacques, S. L., & Prahl, S. A. (1987) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900060604 · Cited by 259
Extinction and absorption coefficients and scattering phase functions of human tissues in vitro
Marchesini, R., Bertoni, A., Andreola, S., Melloni, E., & Sichirollo, A. E. (1989) · Applied Optics · doi:10.1364/ao.28.002318 · Cited by 225
Ray, P., Wu, A. M., & Gambhir, S. S. (2003) · PubMed · Cited by 181
Optical properties of rat liver between 350 and 2200 nm
Parsa, P., Jacques, S. L., & Nishioka, N. S. (1989) · Applied Optics · doi:10.1364/ao.28.002325 · Cited by 176
Torricelli, A., Pifferi, A., Taroni, P., Giambattistelli, E., & Cubeddu, R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/8/313 · Cited by 173
In vitro double-integrating-sphere optical properties of tissues between 630 and 1064 nm
Beek, J. F., Blokland, P., Posthumus, P., Aalders, M., Pickering, J. W., Sterenborg, H. J. C. M., & Gemert, M. J. C. V. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/11/017 · Cited by 162
Optical biopsy of bone tissue: a step toward the diagnosis of bone pathologies
Pifferi, A., Torricelli, A., Taroni, P., Bassi, A., Chikoidze, E., Giambattistelli, E., & Cubeddu, R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1691029 · Cited by 137
Time-gated transillumination of biological tissues and tissuelike phantoms
Mitić, G., Kölzer, J., Otto, J., Plies, E., Sölkner, G., & Zinth, W. (1994) · Applied Optics · doi:10.1364/ao.33.006699 · Cited by 133
Measurement of bone mineral density via light scattering
Ugryumova, N., Matcher, S. J., & Attenburrow, D. P. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/009 · Cited by 109
Lualdi, M., Colombo, A., Farina, B., Tomatis, S., & Marchesini, R. (2001) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1044 · Cited by 94
Barnett, A. H., Culver, J. P., Sorensen, A. G., Dale, A. M., & Boas, D. A. (2003) · Applied Optics · doi:10.1364/ao.42.003095 · Cited by 86
Applications of the 1-D diffusion approximation to the optics of tissues and tissue phantoms
Karagiannes, J. L., Zhang, Z., Grossweiner, B., & Grossweiner, L. I. (1989) · Applied Optics · doi:10.1364/ao.28.002311 · Cited by 85
Solonenko, M. G., Cheung, R. M., Busch, T. M., Kachur, A., Griffin, G. M., Vulcan, T., Zhu, T. C., Wang, H. W., Hahn, S. M., & Yodh, A. G. (2002) · PubMed · Cited by 70
Ritz, J., Roggan, A., Germer, C. T., Isbert, C. M., Müller, G., & Buhr, H. J. (2001) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1054 · Cited by 68
Influence of cell shape and aggregate formation on the optical properties of flowing whole blood
Enejder, A. M. K., Swartling, J., Aruna, P. R., & Andersson‐Engels, S. (2003) · Applied Optics · doi:10.1364/ao.42.001384 · Cited by 67
Torricelli, A. M., Quaresima, V., Pifferi, A., Biscotti, G., Spinelli, L., Taroni, P., Ferrari, M., & Cubeddu, R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/5/003 · Cited by 66
Detector concept for OPET-a combined PET and optical imaging system
Prout, D. L., Silverman, R. W., & Chatziioannou, A. F. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.829736 · Cited by 63
Self-citationThe optical properties of lung as a function of respiration
Beek, J. F., van Staveren, H. J., Posthumus, P., Sterenborg, H. J. C. M., & van Gemert, M. J. C. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/11/018 · Cited by 35
Optical properties of human normal small intestine tissue determined by Kubelka-Munk methodin vitro
Wei, H. (2003) · World Journal of Gastroenterology · doi:10.3748/wjg.v9.i9.2068 · Cited by 28
Martelli, F., Sassaroli, A., Zaccanti, G., & Yamada, Y. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/5/013 · Cited by 25
Cited by
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
Optical tomography: forward and inverse problems
Arridge, S. R., & Schotland, J. C. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123010 · Cited by 625
Digimouse: a 3D whole body mouse atlas from CT and cryosection data
Dogdas, B., Stout, D., Chatziioannou, A. F., & Leahy, R. M. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/3/003 · Cited by 524
Self-citationZhan, Q., Qian, J., Liang, H., Somesfalean, G., Wang, D., He, S., Zhang, Z., & Andersson-Engels, S. (2011) · ACS Nano · doi:10.1021/nn200110j · Cited by 523
Corrigendum: Optical properties of biological tissues: a review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/14/5007 · Cited by 430
Metadata
- Authors
- Alexandrakis, G., Rannou, F. R., & Chatziioannou, A. F.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-08-24
- Volume
- 50
- Issue
- 17
- Pages
- 4225-4241
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2017096549
- Cited by
- 465
- References
- 37
- FWCI
- 15.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.