Passive vortex currents in magneto- and electrocardiography: comparison of magnetic and electric signal strengths
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Vortex currents may be of importance in the early diagnosis of myocardial infarction caused by an occlusion of a coronary artery. We investigated the influence of a passive vortex current distribution, modelled by different conductivities in a hollow cylinder, on the localization error and on the signal strength in both the magnetocardiogram and the electrocardiogram. The hollow cylinder was mounted in a realistically shaped physical torso phantom. A platinum dipole was inserted into the cylinder. The compartment boundaries were modelled with two special ionic exchange membranes. The conductivity ratio of the cylinder compartment to the torso compartment was varied from 0.25 to 100. We compared the simultaneously measured magnetic and electric signal strengths as a function of this conductivity ratio. We found that an increasing conductivity ratio causes only a slight increase (about 19%) of the magnetic signal strength but a strong decrease (about 81%) of the electric signal strength. Using a homogeneous torso model, the dipole localization errors were, depending on the conductivity ratio, up to 16 mm. In conclusion, passive vortex currents might partially explain the differences between magnetocardiographic and electrocardiographic recordings observed both experimentally and clinically.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905
Wood, C. C., Cohen, D., Cuffin, B. N., Yarita, M., & Allison, T. (1985) · Science · doi:10.1126/science.3975600 · Cited by 320
Myocardial infarct size and location in relation to the coronary vascular bed at risk in man.
Lee, J. T., Ideker, R. E., & Reimer, K. A. (1981) · Circulation · doi:10.1161/01.cir.64.3.526 · Cited by 155
BROCKMEIER, K., SCHMITZ, L., CHAVEZ, J. D. J. B., BURGHOFF, M., KOCH, H., ZIMMERMANN, R., & TRAHMS, L. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb01824.x · Cited by 99 · cited 2×
“Recent clinical observations indicate a diverging of MCG and ECG recordings during exercise (Takala et al 2001, Brockmeier et al 1997, Monteiro et al 1997).”
BackgroundReimer, K. A., & Ideker, R. E. (1987) · Human Pathology · doi:10.1016/s0046-8177(87)80031-x · Cited by 99
Possible sources of new information in the magnetocardiogram
Wikswo, J. P., & Barach, J. P. (1982) · Journal of Theoretical Biology · doi:10.1016/0022-5193(82)90350-2 · Cited by 68
Electrically silent magnetic fields
Roth, B. J., & Wikswo, J. P. (1986) · Biophysical Journal · doi:10.1016/s0006-3495(86)83513-5 · Cited by 57
Current multipole expansion to estimate lateral extent of neuronal activity: a theoretical analysis
Nolte, G., & Curio, G. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.871408 · Cited by 56
Magnetocardiographic and Electrocardiographic Exercise Mapping in Healthy Subjects
Takala, P., Hänninen, H., Montonen, J., Mäkijärvi, M., Nenonen, J., Oikarinen, L., Simelius, K., Toivonen, L., & Katila, T. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1376388 · Cited by 42
Vortex Shaped Current Sources in a Physical Torso Phantom
Liehr, M., Haueisen, J., Goernig, M., Seidel, P., Nenonen, J., & Katila, T. E. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8983-6 · Cited by 36
Self-citation
Cited by
Etemadi, H., & Plieger, P. G. (2020) · Advanced Therapeutics · doi:10.1002/adtp.202000061 · Cited by 136
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Optical multichannel room temperature magnetic field imaging system for clinical application
Lembke, G., Erné, S. N., Nowak, H., Menhorn, B., Pasquarelli, A., & Bison, G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.000876 · Cited by 53
Girão, H., & Pereira, P. (2003) · PubMed · Cited by 54
Can magnetocardiography detect patients with non‐ST‐segment elevation myocardial infarction?
Lim, H. K., Chung, N., Kim, K., Ko, Y., Kwon, H., Lee, Y., Kim, J., Joung, B., Kim, J., Yu, K. K., et al. (2007) · Annals of Medicine · doi:10.1080/07853890701538040 · Cited by 38
Detection of patients with coronary artery disease using cardiac magnetic field mapping at rest
Gapelyuk, A., Wessel, N., Fischer, R., Zacharzowsky, U. B., Koch, L., Selbig, D., Schütt, H., Sawitzki, B., Luft, F. C., Dietz, R., et al. (2007) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2007.03.013 · Cited by 31
Steinisch, M., Torke, P. R., Haueisen, J., Hailer, B., Grönemeyer, D. H. W., Leeuwen, P. V., & Comani, S. (2012) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2012.11.014 · Cited by 29
Self-citationHan, X., Pang, J., Xu, D., Wang, R., Xie, F., Yang, Y., Sun, J., Li, Y., Li, R., Yin, X., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/ad0f70 · Cited by 25
Mace, S. E., Peacock, W. F., Stopyra, J. P., Mahler, S. A., Pearson, C., Pena, M. E., & Clark, C. L. (2024) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2024.100372 · Cited by 31
Kyoon Lim, H., Kim, K., Lee, Y.-H., & Chung, N. (2009) · Annals of Medicine · doi:10.1080/07853890903107883 · Cited by 22
Roth, B. J. (2024) · Biophysics Reviews · doi:10.1063/5.0201950 · Cited by 24
Liehr, M., & Haueisen, J. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/1/017 · Cited by 18
Self-citationEquivalent Moving Dipole Localization of Cardiac Ectopic Activity in a Swine Model During Pacing
Lai, D., Liu, C., Eggen, M. D., Iaizzo, P. A., & He, B. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2051448 · Cited by 17
Quantitative evaluation of signal integrity for magnetocardiography
Zhang, S., Wang, Y., Wang, H., Jiang, S., & Xie, X. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/15/010 · Cited by 16
Tao, R., Zhang, S., Zhang, R., Shen, C., Ma, J., Cui, J., Chen, Y., Wang, B., Li, H., Xie, X., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-90615-x · Cited by 14
Advances of magnetocardiography in application of adult and fetal cardiac diseases
Li, J., Shen, Y., Shen, C., Ning, X., & Xiang, M. (2025) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2025.1522467 · Cited by 16
Ashokprabhu, N. D., Ziada, K. M., Daher, E., Cho, L., Schmidt, C. W., Alvarez, Y. R., Palmer, C., Kaur, S., Henry, T. D., Pepine, C. J., et al. (2024) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2024.100424 · Cited by 14
Wetterling, F., Liehr, M., Schimpf, P. H., Liu, H., & Haueisen, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/18/003 · Cited by 13
Self-citationAutomated magnetocardiography classification using a deformable convolutional block attention module
Wang, R., Pang, J., Han, X., Xiang, M., & Ning, X. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.107602 · Cited by 9
Magnetocardiography in the Evaluation of Sudden Cardiac Death Risk: A Systematic Review
Lachlan, T., He, H., KUSANO, K. F., Aiba, T., Brisinda, D., Fenici, R., & Osman, F. (2024) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.70028 · Cited by 9
Real-Time Magnetocardiography with Passive Miniaturized Coil Array in Earth Ambient Field
Zhu, K., & Kiourti, A. (2023) · Sensors · doi:10.3390/s23125567 · Cited by 8
Fenici, R., Picerni, M., Fenici, P., & Brisinda, D. (2025) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2025.100514 · Cited by 13
Brisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6
New clinical application of magnetocardiography: diagnosis of left ventricular hypertrophy
Chen, X., Li, L., Xu, X., Xia, L., Liu, C., Shen, C., & Luo, Y. (2025) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2025.1577662 · Cited by 7
He, W., Zeng, L., Xie, N.-S., Liu, H., Cui, W.-M., Wang, Y., Zhang, Z., Ye, G.-L., Qin, Z.-Y., Guo, Z., et al. (2025) · Frontiers in Medical Technology · doi:10.3389/fmedt.2025.1611046 · Cited by 5
Jia, Y., Pei, H., Xu, D., Pang, J., Chen, Y., Shen, C., & Xiang, M. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108875 · Cited by 5
Şengül, G., Liehr, M., Haueisen, J., & Baysal, U. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9551-7 · Cited by 3
Self-citationMace, S. E., Pena, M. E., Ahee, D. J., & Takla, R. B. (2024) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2024.100441 · Cited by 8
Bioelectric and biomagnetic measurements are differentially sensitive to spiral currents
Haueisen, J., Dietzel, A., Liehr, M., Weiser, T., Elsarnagawy, T., & Bellemann, M. E. (2011) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2011.104 · Cited by 2
Self-citationChaikovsky, I. A., Kazmirchyk, A., Sofienko, S., Liu, Y.-B., Zhou, Y.-F., Feng, X., Xu, L., & Huang, Y. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.104924 · Cited by 4
Wearable Wireless Dual-Plane OPM-MCG System for Rest/Stress Cardiac Magnetic Field Measurement
Li, T., Cheng, H., Wang, D., Yin, Y., Li, C., Gu, W., Jiang, C., Lyu, B., & Gao, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3595239 · Cited by 3
Qi, Y., Liang, J., Zhang, Y., Yang, J., Cao, F., Zhang, X., Li, H., Cui, X., Zhang, H., & Xiang, M. (2026) · Clinical Cardiology · doi:10.1002/clc.70277 · Cited by 1
Magnetocardiography in the diagnosis of suspected ANOCA: a case series
Xue, X., Zhang, J. Y., Zhou, Y., Cheng, L., Zhu, Y., Liang, J., Tian, K., Xu, D., Xiang, S., Li, Q., et al. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1787320 · Cited by 1
Clinical Use of Electrocardiogram
Lakshmanadoss, U. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.98009 · Cited by 2
Leithäuser, B., Jung, F., & Park, J. W. (2012) · Der Kardiologe · doi:10.1007/s12181-012-0401-3
Electro- and Magnetoencephalographic Measurements
Knösche, T. R., & Haueisen, J. (2022) · Springer eBooks · doi:10.1007/978-3-030-74918-7_3
Self-citationLi, J. (2025) · IEEE International Conference on Imaging Systems and Techniques (IST) · doi:10.1109/ist66504.2025.11268424
Meta-analysis of magnetocardiography in diagnosing coronary artery disease and myocardial ischemia
Li, J., Yan, M., Xiang, M., & Ning, X. (2026) · Next research. · doi:10.1016/j.nexres.2026.101496 · Cited by 1
Qi, Y., Ma, K., & Xiang, M. (2026) · International Conference on Bioinformatics and Biomedical Technology (ICBBT) · doi:10.1145/3822521.3822551
Metadata
- Authors
- Dutz, S., Bellemann, M. E., Leder, U., & Haueisen, J.
- Affiliations
- Ernst Abbe University of Applied Sciences Jena (DE)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-12-15
- Volume
- 51
- Issue
- 1
- Pages
- 145-151
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2166799166
- Semantic Scholar
- 625bf7ab2ceaf20f628aab3eb3227426cad69d22
- Cited by
- 39
- References
- 16
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 5 · 2023: 3 · 2022: 4 · 2020: 1 · 2014: 1 · 2012: 2
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Bundesministerium für Bildung und Forschung
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- magnetocardiography, electrocardiogram, myocardial infarction, conductivity ratio, hollow cylinder model, localization error, signal strength, torso phantom, ion exchange membranes
- MeSH terms
- Computer Simulation, Diagnosis, Computer-Assisted, Electric Conductivity, Electrocardiography, Electrodes, Electromagnetic Fields, Electrophysiology, Heart Conduction System, Humans, Ions, Magnetics, Models, Anatomic, Models, Biological, Models, Cardiovascular, Signal Processing, Computer-Assisted, Magnetoencephalography, Body Surface Potential Mapping, Phantoms, Imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.