The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Performance evaluation of the ECAT HRRT: an LSO-LYSO double layer high resolution, high sensitivity scanner
Open accessAbstract
The ECAT high resolution research tomograph (HRRT) is a dedicated brain and small animal PET scanner, with design features that enable high image spatial resolution combined with high sensitivity. The HRRT is the first commercially available scanner that utilizes a double layer of LSO/LYSO crystals to achieve photon detection with depth-of-interaction information. In this study, the performance of the commercial LSO/LYSO HRRT was characterized, using the NEMA protocol as a guideline. Besides measurement of spatial resolution, energy resolution, sensitivity, scatter fraction, count rate performance, correction for attenuation and scatter, hot spot recovery and image quality, a clinical evaluation was performed by means of a HR+/HRRT human brain comparison study. Point source resolution varied across the field of view from approximately 2.3 to 3.2 mm (FWHM) in the transaxial direction and from 2.5 to 3.4 mm in the axial direction. Absolute line-source sensitivity ranged from 2.5 to 3.3% and the NEMA-2001 scatter fraction equalled 45%. Maximum NECR was 45 kcps and 148 kcps according to the NEMA-2001 and 1994 protocols, respectively. Attenuation and scatter correction led to a volume uniformity of 6.3% and a system uniformity of 3.1%. Reconstructed values deviated up to 15 and 8% in regions with high and low densities, respectively, which can possibly be assigned to inaccuracies in scatter estimation. Hot spot recovery ranged from 60 to 94% for spheres with diameters of 1 to 2.2 cm. A high quantitative agreement was met between HR+ and HRRT clinical data. In conclusion, the ECAT HRRT has excellent resolution and sensitivity properties, which is a crucial advantage in many research studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exact and approximate rebinning algorithms for 3-D PET data
Defrise, M., Kinahan, P. E., Townsend, D. W., Michel, C., Sibomana, M., & Newport, D. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563660 · Cited by 758
MicroPET: a high resolution PET scanner for imaging small animals
Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J. W., Jones, W., Moyers, J. C., Newport, D., et al. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.596981 · Cited by 609
New, faster, image-based scatter correction for 3D PET
Watson, C. C. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873020 · Cited by 519
Brix, G., Zaers, J., Adam, L.-E., Bellemann, M. E., Ostertag, H. J., Trojan, H., Haberkorn, U., Doll, J., Oberdorfer, F., & Lorenz, W. J. (1997) · PubMed · Cited by 479
Chatziioannou, A. F., Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Farquhar, T. H., Pedarsani, M., & Phelps, M. E. (1999) · PubMed · Cited by 347
Performance evaluation of the microPET P4: a PET system dedicated to animal imaging
Tai, Y. C., Chatziioannou, A., Siegel, S., Young, J., Newport, D., Goble, R. N., Nutt, R. E., & Cherry, S. R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/7/308 · Cited by 308
High-resolution SPECT using multipinhole collimation
Schramm, N. U., Ebel, G., Engeland, U., Schurrat, T., Behe, M., & Behr, T. M. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.812437 · Cited by 298
PET performance measurements using the NEMA NU 2-2001 standard.
Daube-Witherspoon, M. E., Karp, J. S., Casey, M., DiFilippo, F. P., Hines, H., Muehllehner, G., Simcic, V. J., Stearns, C. W., Adam, L.-E., Kohlmyer, S. G., et al. (2002) · PubMed · Cited by 222
Seidel, J., Vaquero, J. J., & Green, M. V. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.817282 · Cited by 166
OSEM-3D Reconstruction Strategies for the ECAT HRRT
Comtat, Bataille, F., Michel, C. J., Jones, J. P., Sibomana, M., Janeiro, L., & Trébossen, R. (2005) · IEEE Symposium Conference Record Nuclear Science 2004. · doi:10.1109/nssmic.2004.1466639 · Cited by 133
Brambilla, M., Secco, C., Dominietto, M. D., Matheoud, R., Sacchetti, G., & Inglese, E. (2005) · PubMed · Cited by 131
A method for measuring the absolute sensitivity of positron emission tomographic scanners
Bailey, D. L., Jones, T., & Spinks, T. J. (1991) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf02258426 · Cited by 121
The Second Generation HRRT - a Multi Centre Scanner Performance Investigation
Sossi, V., de Jong, H. W. A. M., Barker, W. C., Bloomfield, P. M., Burbar, Z., Camborde, M.-L., Comtat, C., Eriksson, L. A., Houle, S., Keator, D. B., et al. (2006) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2005.1596770 · Cited by 104
Self-citationNuyts, J. L., Michel, C. J., & Dupont, P. J. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.925290 · Cited by 90
NEMA NU 2 performance tests for scanners with intrinsic radioactivity.
Watson, C. C., Casey, M., Eriksson, L., Mulnix, T., Adams, D., & Bendriem, B. (2004) · PubMed · Cited by 90
Metabolic rates in small brain nuclei determined by high-resolution PET.
Heiss, W., Habedank, B., Klein, J. C., Herholz, K., Wienhard, K., Lenox, M., & Nutt, R. (2004) · PubMed · Cited by 80
The ECAT HRRT: NEMA NEC evaluation of the HRRT system, the new high-resolution research tomograph
Eriksson, L. I., Wienhard, K., Eriksson, M., Casey, M. E., Knoess, C., Bruckbauer, T., Hamill, J. J., Schmand, M. J., Gremillion, T., Lenox, M., et al. (2002) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2002.803784 · Cited by 69
Performance of the Fourier rebinning algorithm for PET with large acceptance angles
Matej, S., Karp, J. S., Lewitt, R. M., & Becher, A. J. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/008 · Cited by 67
Evaluation of the TierPET system
Weber, S., Herzog, H. R., Cremer, M., Engels, R., Hamacher, K., Kehren, F., Mühlensiepen, H., Ploux, L., Reinartz, R., Reinhart, P., et al. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.790853 · Cited by 60
PET/SPECT: functional imaging beyond flow
Lammertsma, A. A. (2001) · Vision Research · doi:10.1016/s0042-6989(00)00262-5 · Cited by 52
Self-citationCorrection methods for missing data in sinograms of the HRRT PET scanner
de Jong, H. W. A. M., Boellaard, R., Knoess, C., Lenox, M., Michel, C. J., Casey, M. E., & Lammertsma, A. A. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.817366 · Cited by 50
Self-citation
Cited by
Fundamental limits of spatial resolution in PET
Moses, W. W. (2011) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2010.11.092 · Cited by 565
Hamelin, L., Lagarde, J., Dorothée, G., Leroy, C., Labit, M., Comley, R. A., de Souza, L. C., Corne, H., Dauphinot, L., Bertoux, M., et al. (2016) · Brain · doi:10.1093/brain/aww017 · Cited by 519
Neumeister, A., Normandin, M. D., Pietrzak, R. H., Piomelli, D., Zheng, M. Q., Gujarro-Anton, A., Potenza, M. N., Bailey, C. R., Lin, S. F., Najafzadeh, S., et al. (2013) · Molecular Psychiatry · doi:10.1038/mp.2013.61 · Cited by 361
Effects of Expectation on Placebo-Induced Dopamine Release in Parkinson Disease
Lidstone, S. C., Schulzer, M., Dinelle, K., Mak, E., Sossi, V., Ruth, T. J., de la Fuente-Fernández, R., Phillips, A. G., & Stoessl, A. J. (2010) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2010.88 · Cited by 323
In vivo measurement of widespread synaptic loss in Alzheimer’s disease with SV2A PET
Mecca, A. P., Chen, M., O'Dell, R. S., Naganawa, M., Toyonaga, T., Godek, T. A., Harris, J. E., Bartlett, H. H., Zhao, W., Nabulsi, N. B., et al. (2020) · Alzheimer's & Dementia · doi:10.1002/alz.12097 · Cited by 288
Metadata
- Authors
- Jong, H. W. A. M. D., Velden, F. H. P. V., Kloet, R. W., Buijs, F. L., Boellaard, R., & Lammertsma, A. A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2007-02-14
- Volume
- 52
- Issue
- 5
- Pages
- 1505-1526
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2092821152
- Cited by
- 349
- References
- 21
- FWCI
- 16.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.