Performance evaluation of the ECAT HRRT: an LSO-LYSO double layer high resolution, high sensitivity scanner
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The ECAT high resolution research tomograph (HRRT) is a dedicated brain and small animal PET scanner, with design features that enable high image spatial resolution combined with high sensitivity. The HRRT is the first commercially available scanner that utilizes a double layer of LSO/LYSO crystals to achieve photon detection with depth-of-interaction information. In this study, the performance of the commercial LSO/LYSO HRRT was characterized, using the NEMA protocol as a guideline. Besides measurement of spatial resolution, energy resolution, sensitivity, scatter fraction, count rate performance, correction for attenuation and scatter, hot spot recovery and image quality, a clinical evaluation was performed by means of a HR+/HRRT human brain comparison study. Point source resolution varied across the field of view from approximately 2.3 to 3.2 mm (FWHM) in the transaxial direction and from 2.5 to 3.4 mm in the axial direction. Absolute line-source sensitivity ranged from 2.5 to 3.3% and the NEMA-2001 scatter fraction equalled 45%. Maximum NECR was 45 kcps and 148 kcps according to the NEMA-2001 and 1994 protocols, respectively. Attenuation and scatter correction led to a volume uniformity of 6.3% and a system uniformity of 3.1%. Reconstructed values deviated up to 15 and 8% in regions with high and low densities, respectively, which can possibly be assigned to inaccuracies in scatter estimation. Hot spot recovery ranged from 60 to 94% for spheres with diameters of 1 to 2.2 cm. A high quantitative agreement was met between HR+ and HRRT clinical data. In conclusion, the ECAT HRRT has excellent resolution and sensitivity properties, which is a crucial advantage in many research studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exact and approximate rebinning algorithms for 3-D PET data
Defrise, M., Kinahan, P. E., Townsend, D. W., Michel, C., Sibomana, M., & Newport, D. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563660 · Cited by 758
MicroPET: a high resolution PET scanner for imaging small animals
Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J. W., Jones, W., Moyers, J. C., Newport, D., et al. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.596981 · Cited by 609
New, faster, image-based scatter correction for 3D PET
Watson, C. C. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873020 · Cited by 519
Brix, G., Zaers, J., Adam, L.-E., Bellemann, M. E., Ostertag, H. J., Trojan, H., Haberkorn, U., Doll, J., Oberdorfer, F., & Lorenz, W. J. (1997) · PubMed · Cited by 479
Chatziioannou, A. F., Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Farquhar, T. H., Pedarsani, M., & Phelps, M. E. (1999) · PubMed · Cited by 347
Performance evaluation of the microPET P4: a PET system dedicated to animal imaging
Tai, Y. C., Chatziioannou, A., Siegel, S., Young, J., Newport, D., Goble, R. N., Nutt, R. E., & Cherry, S. R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/7/308 · Cited by 308
High-resolution SPECT using multipinhole collimation
Schramm, N. U., Ebel, G., Engeland, U., Schurrat, T., Behe, M., & Behr, T. M. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.812437 · Cited by 298
PET performance measurements using the NEMA NU 2-2001 standard.
Daube-Witherspoon, M. E., Karp, J. S., Casey, M., DiFilippo, F. P., Hines, H., Muehllehner, G., Simcic, V. J., Stearns, C. W., Adam, L.-E., Kohlmyer, S. G., et al. (2002) · PubMed · Cited by 222
Seidel, J., Vaquero, J. J., & Green, M. V. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.817282 · Cited by 166
A method for measuring the absolute sensitivity of positron emission tomographic scanners
Bailey, D. L., Jones, T., & Spinks, T. J. (1991) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf02258426 · Cited by 136
Cited by
Fundamental limits of spatial resolution in PET
Moses, W. W. (2011) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2010.11.092 · Cited by 565
Hamelin, L., Lagarde, J., Dorothée, G., Leroy, C., Labit, M., Comley, R. A., de Souza, L. C., Corne, H., Dauphinot, L., Bertoux, M., et al. (2016) · Brain · doi:10.1093/brain/aww017 · Cited by 519
Neumeister, A., Normandin, M. D., Pietrzak, R. H., Piomelli, D., Zheng, M. Q., Gujarro-Anton, A., Potenza, M. N., Bailey, C. R., Lin, S. F., Najafzadeh, S., et al. (2013) · Molecular Psychiatry · doi:10.1038/mp.2013.61 · Cited by 361
Effects of Expectation on Placebo-Induced Dopamine Release in Parkinson Disease
Lidstone, S. C., Schulzer, M., Dinelle, K., Mak, E., Sossi, V., Ruth, T. J., de la Fuente-Fernández, R., Phillips, A. G., & Stoessl, A. J. (2010) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2010.88 · Cited by 323
In vivo measurement of widespread synaptic loss in Alzheimer’s disease with SV2A PET
Mecca, A. P., Chen, M., O'Dell, R. S., Naganawa, M., Toyonaga, T., Godek, T. A., Harris, J. E., Bartlett, H. H., Zhao, W., Nabulsi, N. B., et al. (2020) · Alzheimer's & Dementia · doi:10.1002/alz.12097 · Cited by 288
Down Syndrome, Partial Trisomy 21, and Absence of Alzheimer’s Disease: The Role of APP
Doran, E., Keator, D., Head, E., Phelan, M. J., Kim, R., Totoiu, M., Barrio, J. R., Small, G. W., Potkin, S. G., & Lott, I. T. (2017) · Journal of Alzheimer’s Disease · doi:10.3233/jad-160836 · Cited by 244
“Research Tomograph (HRRT, Siemen’s Medical Sys159 tems) [31, 32].”
PET and SPECT in epilepsy: a critical review.
la Fougère, C., Rominger, A., Förster, S., Geisler, J., & Bartenstein, P. (2009) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2009.02.025 · Cited by 224
“radiopharmaceutical has ideal properties for PET imaging and will allow with state-of-the-art equipment to image benzodiazepine– GABAA receptor binding with a spatial resolution of approximately 3 mm [40].”
BackgroundLatest Advances in Molecular Imaging Instrumentation
Pichler, B. J., Wehrl, H. F., & Judenhofer, M. S. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.045880 · Cited by 223
“The only exceptions are animal PET systems such as the eXplore VISTA (GE Healthcare) (35) and the LabPET (Gamma Medica) (36), as well as the high-resolution brain scanner HRRT (37) (Siemens Medical Solutions), which uses 2 layers of different crystal types stacked together—the phoswich design (Fig.”
Varrone, A., Sjöholm, N., Eriksson, L., Gulyás, B., Halldin, C., & Farde, L. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1156-3 · Cited by 206
“The HRRT system The in plane resolution with OP-3D-OSEM reconstruction was 2.3 mm FWHM in the centre of the FOV and 3.1 mm at 10 cm off-centre directions.”
MethodInfluentialMecca, A. P., O'Dell, R. S., Sharp, E. S., Banks, E. R., Bartlett, H. H., Zhao, W., Lipior, S., Diepenbrock, N. G., Chen, M., Naganawa, M., et al. (2022) · Alzheimer's & Dementia · doi:10.1002/alz.12582 · Cited by 186
Exercise increases caudate dopamine release and ventral striatal activation in Parkinson's disease
Sacheli, M. A., Neva, J. L., Lakhani, B., Murray, D. K., Vafai, N., Shahinfard, E., English, C., McCormick, S., Dinelle, K., Neilson, N., et al. (2019) · Movement Disorders · doi:10.1002/mds.27865 · Cited by 196
“4 mm(3)) full width at half maximum.(24) To investigate DA release in the dorsal striatum, participants underwent 2 PET scans (baseline and post rTMS stimulus) following intravenous bolus administration of [(11)C] RAC ( 185 MBq per scan).”
MethodHamelin, L., Lagarde, J., Dorothée, G., Potier, M. C., Corlier, F., Kuhnast, B., Caillé, F., Dubois, B., Fillon, L., Chupin, M., et al. (2018) · Brain · doi:10.1093/brain/awy079 · Cited by 177
Rissanen, E., Tuisku, J., Rokka, J., Paavilainen, T., Parkkola, R., Rinne, J. O., & Airas, L. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.131698 · Cited by 171
Ding, Y.-S., Singhal, T., Planeta-Wilson, B., Gallezot, J.-D., Nabulsi, N., Labaree, D., Ropchan, J., Henry, S., Williams, W., Carson, R. E., et al. (2010) · Synapse · doi:10.1002/syn.20696 · Cited by 168
Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET
Rapisarda, E., Bettinardi, V, Thielemans, K., & Gilardi, M. C. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/14/012 · Cited by 142
“Other authors have used a line source in a warm radioactive background to measure the spatial resolution of a PET system (De Jong et al 2007).”
BackgroundPretreatment Brain States Identify Likely Nonresponse to Standard Treatments for Depression
McGrath, C. L., Kelley, M. E., Dunlop, B. W., Holtzheimer III, P. E., Craighead, W. E., & Mayberg, H. S. (2014) · Biological Psychiatry · doi:10.1016/j.biopsych.2013.12.005 · Cited by 139
“FDG-PET images were attenuation corrected (32).”
MethodNatalizumab treatment reduces microglial activation in the white matter of the MS brain
Sucksdorff, M., Tuisku, J., Matilainen, M., Vuorimaa, A., Smith, S., Keitilä, J., Rokka, J., Parkkola, R., Nylund, M., Rinne, J., et al. (2019) · Neurology Neuroimmunology & Neuroinflammation · doi:10.1212/nxi.0000000000000574 · Cited by 71
Angarita, G. A., Worhunsky, P. D., Naganawa, M., Toyonaga, T., Nabulsi, N. B., Li, C. R., Esterlis, I., Skosnik, P. D., Radhakrishnan, R., Pittman, B., et al. (2022) · Addiction Biology · doi:10.1111/adb.13123 · Cited by 38
Cervenka, S., Frick, A., Bodén, R., & Lubberink, M. (2022) · Translational Psychiatry · doi:10.1038/s41398-022-01990-2 · Cited by 32
van Dyck, C. H., Mecca, A. P., O’Dell, R. S., Bartlett, H. H., Diepenbrock, N. G., Huang, Y., Hamby, M. E., Grundman, M., Catalano, S. M., Caggiano, A. O., et al. (2024) · Alzheimer's Research & Therapy · doi:10.1186/s13195-024-01382-2 · Cited by 29
Metadata
- Authors
- Jong, H. W. A. M. D., Velden, F. H. P. V., Kloet, R. W., Buijs, F. L., Boellaard, R., & Lammertsma, A. A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2007-02-14
- Volume
- 52
- Issue
- 5
- Pages
- 1505-1526
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2092821152
- Cited by
- 349
- References
- 21
- FWCI
- 16.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.