Four-dimensional deformable image registration using trajectory modeling
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
A four-dimensional deformable image registration (4D DIR) algorithm, referred to as 4D local trajectory modeling (4DLTM), is presented and applied to thoracic 4D computed tomography (4DCT) image sets. The theoretical framework on which this algorithm is built exploits the incremental continuity present in 4DCT component images to calculate a dense set of parameterized voxel trajectories through space as functions of time. The spatial accuracy of the 4DLTM algorithm is compared with an alternative registration approach in which component phase to phase (CPP) DIR is utilized to determine the full displacement between maximum inhale and exhale images. A publically available DIR reference database (http://www.dir-lab.com) is utilized for the spatial accuracy assessment. The database consists of ten 4DCT image sets and corresponding manually identified landmark points between the maximum phases. A subset of points are propagated through the expiratory 4DCT component images. Cubic polynomials were found to provide sufficient flexibility and spatial accuracy for describing the point trajectories through the expiratory phases. The resulting average spatial error between the maximum phases was 1.25 mm for the 4DLTM and 1.44 mm for the CPP. The 4DLTM method captures the long-range motion between 4DCT extremes with high spatial accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1981) · Cited by 11,963
Horn, B. K. P., & Schunck, B. G. (1981) · Artificial Intelligence · doi:10.1016/0004-3702(81)90024-2 · Cited by 10,312
Horn, B. K., & Schunck, B. G. (1981) · SPIE Proceedings · doi:10.1117/12.965761 · Cited by 7,394
Finite Volume Methods for Hyperbolic Problems
LeVeque, R. J. (2002) · Cambridge University Press eBooks · doi:10.1017/cbo9780511791253 · Cited by 6,313
Principal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Performance of optical flow techniques
Barron, J. L., Fleet, D. J., & Beauchemin, S. S. (1994) · International Journal of Computer Vision · doi:10.1007/bf01420984 · Cited by 4,305 · cited 2×
“It is known for optical flow algorithms that small displacements result in reduced spatial error versus large displacements due to many factors including the linear approximations made in their formulation (Barron et al., 1994).”
BackgroundMethodA survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Seppenwoolde, Y., Shirato, H., Kitamura, K., Shimizu, S., van Herk, M., Lebesque, J. V., & Miyasaka, K. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02803-1 · Cited by 1,379
The computation of optical flow
Beauchemin, S. S., & Barron, J. L. (1995) · ACM Computing Surveys · doi:10.1145/212094.212141 · Cited by 1,278
HAMMER: hierarchical attribute matching mechanism for elastic registration
Shen, D., & Davatzikos, C. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.803111 · Cited by 1,083
Performance of optical flow techniques
Barron, J. L., Fleet, D. J., Beauchemin, S. S., & Burkitt, T. A. (2003) · Proceedings 1992 IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1992.223269 · Cited by 743
Image deformation using moving least squares
Schaefer, S., McPhail, T., & Warren, J. (2006) · ACM Transactions on Graphics · doi:10.1145/1141911.1141920 · Cited by 674
4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
Pan, T., Lee, T.-Y., Rietzel, E., & Chen, G. T. Y. (2004) · Medical Physics · doi:10.1118/1.1639993 · Cited by 624
Castillo, R., Castillo, E., Guerra, R., Johnson, V. E., McPhail, T., Garg, A. K., & Guerrero, T. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/7/001 · Cited by 592
Self-citation4-dimensional computed tomography imaging and treatment planning
KEALL, P. (2004) · Seminars in Radiation Oncology · doi:10.1053/j.semradonc.2003.10.006 · Cited by 484
Shirato, H., Shimizu, S., Kitamura, K., Nishioka, T., Kagei, K., Hashimoto, S., Aoyama, H., Kunieda, T., Shinohara, N., Dosaka-Akita, H., et al. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00625-8 · Cited by 464
Accuracy of finite element model‐based multi‐organ deformable image registration
Brock, K. K., Sharpe, M. B., Dawson, L. A., Kim, S. M., & Jaffray, D. A. (2005) · Medical Physics · doi:10.1118/1.1915012 · Cited by 375
Dense estimation of fluid flows
Corpetti, T., Memin, E., & Perez, P. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.990137 · Cited by 360
Segmentation, registration, and measurement of shape variation via image object shape
Pizer, S. M., Fritsch, D. S., Yushkevich, P. A., Johnson, V. E., & Chaney, E. L. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811263 · Cited by 340
Reinhardt, J. M., Ding, K., Cao, K., Christensen, G. E., Hoffman, E. A., & Bodas, S. V. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.03.007 · Cited by 322
Real-time 3D computed tomographic reconstruction using commodity graphics hardware
Xu, F., & Mueller, K. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/006 · Cited by 223
Sharp, G. C., Kandasamy, N., Singh, H., & Folkert, M. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/19/003 · Cited by 190
Zen and the art of medical image registration: correspondence, homology, and quality
Crum, W. R., Griffin, L. D., Hill, D. L. G., & Hawkes, D. J. (2003) · NeuroImage · doi:10.1016/j.neuroimage.2003.07.014 · Cited by 186
Image registration and data fusion in radiation therapy
Kessler, M. L. (2006) · The British Journal of Radiology · doi:10.1259/bjr/70617164 · Cited by 165
Assessment of a model-based deformable image registration approach for radiation therapy planning.
Kaus, M., Brock, K., Pekar, V., Dawson, L., Nichol, A., & Jaffray, D. (2007) · International Journal of Radiation Oncology, Biology, Physics · doi:10.1016/j.ijrobp.2007.01.056 · Cited by 162
Wolthaus, J., Sonke, J., van Herk, M., & Damen, E. M. F. (2008) · Medical Physics · doi:10.1118/1.2966347 · Cited by 157
Evaluation of deformable registration of patient lung 4DCT with subanatomical region segmentations
Wu, Z., Rietzel, E., Boldea, V., Sarrut, D., & Sharp, G. C. (2008) · Medical Physics · doi:10.1118/1.2828378 · Cited by 151
Sarrut, D., Boldea, V., Miguet, S., & Ginestet, C. (2006) · Medical Physics · doi:10.1118/1.2161409 · Cited by 150
Boldea, V., Sharp, G. C., Jiang, S. B., & Sarrut, D. (2008) · Medical Physics · doi:10.1118/1.2839103 · Cited by 149
Samant, S. S., Xia, J., Muyan-Özçelik, P., & Owens, J. D. (2008) · Medical Physics · doi:10.1118/1.2948318 · Cited by 119
Contact surface and material nonlinearity modeling of human lungs
Al-Mayah, A., Moseley, J., & Brock, K. K. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/1/022 · Cited by 112
Deformable registration of 4D computed tomography data
Rietzel, E., & Chen, G. T. Y. (2006) · Medical Physics · doi:10.1118/1.2361077 · Cited by 102
Deformable registration for image-guided radiation therapy
Sarrut, D. (2006) · Zeitschrift für Medizinische Physik · doi:10.1078/0939-3889-00327 · Cited by 96
Noe, K. Ø., de Senneville, B. D., Elstrøm, U. V., Tanderup, K., & Sørensen, T. S. (2008) · Acta Oncologica · doi:10.1080/02841860802258760 · Cited by 89
Four-dimensional processing of deformable cardiac PET data
Klein, G. J., & Huesman, R. H. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00050-0 · Cited by 75
Pevsner, A., Davis, B., Joshi, S. C., et al. (2006) · Medical Physics · doi:10.1118/1.2161408 · Cited by 63
Fast convolution‐superposition dose calculation on graphics hardware
Hissoiny, S., Ozell, B., & Després, P. (2009) · Medical Physics · doi:10.1118/1.3120286 · Cited by 58
Estimating myocardial motion by 4D image warping
Sundar, H., Litt, H. I., & Shen, D. G. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2009.04.022 · Cited by 54
Hybrid multiscale landmark and deformable image registration.
Paquin, D., Levy, D., & Xing, L. (2007) · Mathematical biosciences and engineering : MBE · doi:10.3934/mbe.2007.4.711 · Cited by 45
Quality Assurance of Serial 3D Image Registration, Fusion, and Segmentation
Sharpe, M., & Brock, K. K. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.06.087 · Cited by 34
Four-Dimensional Image Registration for Image-Guided Radiotherapy
Schreibmann, E., Thorndyke, B., Li, T., Wang, J., & Xing, L. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.01.042 · Cited by 27
Castillo, E. M. (2007) · Rice Research Repository (Rice University) · Cited by 3
Self-citation
Cited by
A deep learning framework for unsupervised affine and deformable image registration
de Vos, B. D., Berendsen, F. F., Viergever, M. A., Sokooti, H., Staring, M., & Išgum, I. (2019) · Medical Image Analysis · doi:10.1016/j.media.2018.11.010 · Cited by 818
“e MR images, we conduct experiments on a diverse set of low-dose chest CTs for inter-patient registration, and we evaluate the method on the publicly available DIR-Lab dataset for image registration (Castillo et al., 2010, 2009). 2. Method In image registration the aim is to nd a coordinate transformation T: I F !I M…”
MethodInfluentialMIND: Modality independent neighbourhood descriptor for multi-modal deformable registration
Heinrich, M. P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F. V., Brady, S. M., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.05.008 · Cited by 707
Respiratory motion models: A review
McClelland, J. R., Hawkes, D. J., Schaeffter, T., & King, A. P. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.09.005 · Cited by 385
MRF-Based Deformable Registration and Ventilation Estimation of Lung CT
Heinrich, H. P., Jenkinson, M., Brady, M., & Schnabel, J. A. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2246577 · Cited by 311
Going Deep in Medical Image Analysis: Concepts, Methods, Challenges, and Future Directions
Altaf, F., Islam, S. M. S., Akhtar, N., & Janjua, N. K. (2019) · IEEE Access · doi:10.1109/access.2019.2929365 · Cited by 286
Metadata
- Authors
- Castillo, E., Castillo, R., Martinez, J., Shenoy, M., & Guerrero, T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2009-12-11
- Volume
- 55
- Issue
- 1
- Pages
- 305-327
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2075559423
- Cited by
- 261
- References
- 42
- FWCI
- 10.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.