Improved scatter correction using adaptive scatter kernel superposition
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Accurate scatter correction is required to produce high-quality reconstructions of x-ray cone-beam computed tomography (CBCT) scans. This paper describes new scatter kernel superposition (SKS) algorithms for deconvolving scatter from projection data. The algorithms are designed to improve upon the conventional approach whose accuracy is limited by the use of symmetric kernels that characterize the scatter properties of uniform slabs. To model scatter transport in more realistic objects, nonstationary kernels, whose shapes adapt to local thickness variations in the projection data, are proposed. Two methods are introduced: (1) adaptive scatter kernel superposition (ASKS) requiring spatial domain convolutions and (2) fast adaptive scatter kernel superposition (fASKS) where, through a linearity approximation, convolution is efficiently performed in Fourier space. The conventional SKS algorithm, ASKS, and fASKS, were tested with Monte Carlo simulations and with phantom data acquired on a table-top CBCT system matching the Varian On-Board Imager (OBI). All three models accounted for scatter point-spread broadening due to object thickening, object edge effects, detector scatter properties and an anti-scatter grid. Hounsfield unit (HU) errors in reconstructions of a large pelvis phantom with a measured maximum scatter-to-primary ratio over 200% were reduced from -90 ± 58 HU (mean ± standard deviation) with no scatter correction to 53 ± 82 HU with SKS, to 19 ± 25 HU with fASKS and to 13 ± 21 HU with ASKS. HU accuracies and measured contrast were similarly improved in reconstructions of a body-sized elliptical Catphan phantom. The results show that the adaptive SKS methods offer significant advantages over the conventional scatter deconvolution technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319 · cited 1×
“…of the beam spectrum, external filtration and bowtie filter, and detector response (Star-Lack et al 2009); (5) FDK convolution and backprojection (Feldkamp et al 1984); (6) Linear scale and offset to convert linear attenuation coefficients to Hounsfield units; (7) Ring correction of the final…”
BackgroundMCNP^ -A General Monte Carlo N-Particle Transport Code, Version 4C
Briesmeister, J. F. (2000) · Medical Entomology and Zoology · Cited by 784
Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter
Siewerdsen, J. H., & Jaffray, D. A. (2001) · Medical Physics · doi:10.1118/1.1339879 · Cited by 612 · cited 1×
“However, even when such approaches are employed, CBCT projection data may still possess very high scatter-to-primary ratios (SPRs) causing severe artifacts if uncorrected (Siewerdsen and Jaffray 2001).”
BackgroundAdvances in Image-Guided Radiation Therapy
Dawson, L. A., & Jaffray, D. A. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.09.9515 · Cited by 420
X‐ray scatter correction algorithm for cone beam CT imaging
Ning, R., Tang, X., & Conover, D. (2004) · Medical Physics · doi:10.1118/1.1711475 · Cited by 322 · cited 1×
“…et al 2006, Zbijewski and Beekman 2006, Rinkel et al 2007, Meyer et al 2010, Wiegert et al 2005), beam modulators (Maltz et al 2006, Zhu et al 2006), beam stop arrays (Ning et al 2004, Maltz et al 2008b), two scans (Virshup et al 2006, Zhu et al 2009) and detector shadowing (Siewerdsen et al 2006).”
BackgroundSiewerdsen, J. H., Daly, M. J., Bakhtiar, B., Moseley, D. J., Richard, S., Keller, H., & Jaffray, D. A. (2006) · Medical Physics · doi:10.1118/1.2148916 · Cited by 283
Scatter Correction Method for X-Ray CT Using Primary Modulation: Theory and Preliminary Results
Zhu, L., Bennett, N. R., & Fahrig, R. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.884636 · Cited by 220 · cited 1×
“…2004, Kyriakou et al 2006, Zbijewski and Beekman 2006, Rinkel et al 2007, Meyer et al 2010, Wiegert et al 2005), beam modulators (Maltz et al 2006, Zhu et al 2006), beam stop arrays (Ning et al 2004, Maltz et al 2008b), two scans (Virshup et al 2006, Zhu et al 2009) and detector shadowing…”
BackgroundDaly, M. J., Siewerdsen, J. H., Moseley, D. J., Jaffray, D. A., & Irish, J. C. (2006) · Medical Physics · doi:10.1118/1.2349687 · Cited by 207 · cited 2×
“…silicon flat panel imagers, cone-beam computed tomography (CBCT) imaging has become practical for many diverse applications including dental imaging, interventional and diagnostic C-arm imaging, and image-guided radiotherapy (IGRT) (Daly et al 2006, Dawson and Jaffray 2007, Oldham et al 2005).”
BackgroundScatter correction for cone‐beam CT in radiation therapy
Zhu, L., Xie, Y., Wang, J., & Xing, L. (2009) · Medical Physics · doi:10.1118/1.3130047 · Cited by 202
Efficient object scatter correction algorithm for third and fourth generation CT scanners
Ohnesorge, B. M., Flohr, T. G., & Klingenbeck-Regn, K. W. (1999) · European Radiology · doi:10.1007/s003300050710 · Cited by 180 · cited 2×
“Previously, the SKS model has been implemented for kV fan-beam CT (Ohnesorge et al 1999), MV-CBCT (Maltz et al 2008a, Petit et al 2008) and kVCBCT (Li et al 2008) with varying degrees of success.”
Method
Cited by
Modelling the physics in the iterative reconstruction for transmission computed tomography
Nuyts, J., De Man, B., Fessler, J. A., Zbijewski, W., & Beekman, F. J. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/12/r63 · Cited by 199
Rührnschopf and, E., & Klingenbeck, K. (2011) · Medical Physics · doi:10.1118/1.3589140 · Cited by 160
Sisniega, A., Zbijewski, W., Badal, A., Kyprianou, I. S., Stayman, J. W., Vaquero, J. J., & Siewerdsen, J. H. (2013) · Medical Physics · doi:10.1118/1.4801895 · Cited by 117
Revolutionizing radiation therapy: the role of AI in clinical practice
Kawamura, M., Kamomae, T., Yanagawa, M., Kamagata, K., Fujita, S., Ueda, D., Matsui, Y., Fushimi, Y., Fujioka, T., Nozaki, T., et al. (2024) · Journal of Radiation Research · doi:10.1093/jrr/rrad090 · Cited by 86
“Recent studieshavebeenconductedtoimproveCBCTimagequalityusingU-Net and CycleGAN [68, 69].”
Maier, J., Sawall, S., Kachelriess, M., & Berker, Y. (2018) · Medical Imaging 2018: Physics of Medical Imaging · doi:10.1117/12.2292919 · Cited by 40
Metadata
- Authors
- Sun, M., & Star-Lack, J. M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2010-10-28
- Volume
- 55
- Issue
- 22
- Pages
- 6695-6720
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1977836277
- Cited by
- 233
- References
- 24
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.