X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp x-rays
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
A conventional x-ray fluorescence computed tomography (XFCT) technique requires monochromatic synchrotron x-rays to simultaneously determine the spatial distribution and concentration of various elements such as metals in a sample. However, the synchrotron-based XFCT technique appears to be unsuitable for in vivo imaging under a typical laboratory setting. In this study we demonstrated, for the first time to our knowledge, the possibility of performing XFCT imaging of a small animal-sized object containing gold nanoparticles (GNPs) at relatively low concentrations using polychromatic diagnostic energy range x-rays. Specifically, we created a phantom made of polymethyl methacrylate plastic containing two cylindrical columns filled with saline solution at 1 and 2 wt% GNPs, respectively, mimicking tumors/organs within a small animal. XFCT scanning of the phantom was then performed using microfocus 110 kVp x-ray beam and cadmium telluride (CdTe) x-ray detector under a pencil beam geometry after proper filtering of the x-ray beam and collimation of the detector. The reconstructed images clearly identified the locations of the two GNP-filled columns with different contrast levels directly proportional to gold concentration levels. On the other hand, the current pencil-beam implementation of XFCT is not yet practical for routine in vivo imaging tasks with GNPs, especially in terms of scanning time. Nevertheless, with the use of multiple detectors and a limited number of projections, it may still be used to image some objects smaller than the current phantom size. The current investigation suggests several modification strategies of the current XFCT setup, such as the adoption of the quasi-monochromatic cone/fan x-ray beam and XFCT-specific spatial filters or pinhole detector collimators, in order to establish the ultimate feasibility of a bench-top XFCT system for GNP-based preclinical molecular imaging applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanoshell-mediated near-infrared thermal therapy of tumors under magnetic resonance guidance
Hirsch, L. R., Stafford, R. J., Bankson, J. A., Sershen, S. R., Rivera, B., Price, R. E., Hazle, J. D., Halas, N. J., & West, J. L. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2232479100 · Cited by 3,955
Radiobiology for the Radiologist.
(1974) · Annals of Internal Medicine · doi:10.7326/0003-4819-80-3-438_1 · Cited by 3,484
Monotone Piecewise Cubic Interpolation
Fritsch, F. N., & Carlson, R. E. (1980) · SIAM Journal on Numerical Analysis · doi:10.1137/0717021 · Cited by 2,491 · cited 1×
“…function was used to fit the portion of the data for the off-peak ranges (64.5–66.5, 67.5–68.3 and 69.3–71.3 keV), and a piecewise cubic Hermite interpolating polynomial (Fritsch and Carlson 1980) was applied to estimate the background counts for the peak ranges (66.5–67.5 and 68.3–69.3 keV).”
MethodInfluentialIn vivo tumor targeting and spectroscopic detection with surface-enhanced Raman nanoparticle tags
Qian, X., Peng, X.-H., Ansari, D. O., Yin-Goen, Q., Chen, G. Z., Shin, D. M., Yang, L., Young, A. N., Wang, M. D., & Nie, S. (2008) · Nature Biotechnology · doi:10.1038/nbt1377 · Cited by 2,201 · cited 3×
“…passively or actively for therapy and/or imaging purposes during in vivo experiments using various forms (e.g. sphere, shell, rod, etc) of metal, semiconductor and polymer nanoparticles (Sokolov et al 2003, Cai et al 2006, Diagaradjane et al 2008a, McCarthy and Weissleder 2008, Qian et al 2008).”
BackgroundMethodThe use of gold nanoparticles to enhance radiotherapy in mice
Hainfeld, J. F., Slatkin, D. N., & Smilowitz, H. M. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/18/n03 · Cited by 1,638 · cited 2×
“Consequently, over the years, some therapeutic approaches based on these properties have been proposed for the treatment of cancers (Hirsh et al 2003, Hainfeld et al 2004, Cho 2005, Diagaradjane et al 2008a, von Maltzahn et al 2009, Cho et al 2009).”
BackgroundGold nanoparticles: a new X-ray contrast agent
Hainfeld, J. F., Slatkin, D. N., Focella, T. M., & Smilowitz, H. M. (2006) · The British Journal of Radiology · doi:10.1259/bjr/13169882 · Cited by 1,351 · cited 1×
“Micro-computed tomography (CT) could be used to image animal organs loaded with GNPs (Hainfeld et al 2006).”
BackgroundComputationally Guided Photothermal Tumor Therapy Using Long-Circulating Gold Nanorod Antennas
von Maltzahn, G., Park, J.-H., Agrawal, A., Bandaru, N. K., Das, S. K., Sailor, M. J., & Bhatia, S. N. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-4242 · Cited by 1,051 · cited 1×
“Consequently, over the years, some therapeutic approaches based on these properties have been proposed for the treatment of cancers (Hirsh et al 2003, Hainfeld et al 2004, Cho 2005, Diagaradjane et al 2008a, von Maltzahn et al 2009, Cho et al 2009).”
BackgroundPeptide-Labeled Near-Infrared Quantum Dots for Imaging Tumor Vasculature in Living Subjects
Cai, W., Shin, D.-W., Chen, K., Gheysens, O., Cao, Q., Wang, S. X., Gambhir, S. S., & Chen, X. (2006) · Nano Letters · doi:10.1021/nl052405t · Cited by 948 · cited 1×
“…passively or actively for therapy and/or imaging purposes during in vivo experiments using various forms (e.g. sphere, shell, rod, etc) of metal, semiconductor and polymer nanoparticles (Sokolov et al 2003, Cai et al 2006, Diagaradjane et al 2008a, McCarthy and Weissleder 2008, Qian et al 2008).”
BackgroundMultifunctional magnetic nanoparticles for targeted imaging and therapy
MCCARTHY, J., & WEISSLEDER, R. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.014 · Cited by 892 · cited 1×
“…passively or actively for therapy and/or imaging purposes during in vivo experiments using various forms (e.g. sphere, shell, rod, etc) of metal, semiconductor and polymer nanoparticles (Sokolov et al 2003, Cai et al 2006, Diagaradjane et al 2008a, McCarthy and Weissleder 2008, Qian et al 2008).”
BackgroundSokolov, K., Follen, M. M., Aaron, J., Pavlova, I., Malpica, A. L., Lotan, R., & Richards-Kortum, R. R. (2003) · PubMed · Cited by 838
Cited by
Biological mechanisms of gold nanoparticle radiosensitization
Rosa, S., Connolly, C., Schettino, G., Butterworth, K. T., & Prise, K. M. (2017) · Cancer Nanotechnology · doi:10.1186/s12645-017-0026-0 · Cited by 260
Roadmap to Clinical Use of Gold Nanoparticles for Radiation Sensitization
Schuemann, J., Berbeco, R., Chithrani, D. B., Cho, S. H., Kumar, R., McMahon, S. J., Sridhar, S., & Krishnan, S. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.09.032 · Cited by 253
Self-citationAdvances in functional X-ray imaging techniques and contrast agents
Chen, H., Rogalski, M. M., & Anker, J. N. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp41858d · Cited by 168
Metadata
- Authors
- Cheong, S.-K., Jones, B. L., K Siddiqi, A., Liu, F., Manohar, N., & Cho, S. H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2010-01-13
- Volume
- 55
- Issue
- 3
- Pages
- 647-662
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1964569755
- Cited by
- 165
- References
- 23
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.