Robust principal component analysis-based four-dimensional computed tomography
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
The purpose of this paper for four-dimensional (4D) computed tomography (CT) is threefold. (1) A new spatiotemporal model is presented from the matrix perspective with the row dimension in space and the column dimension in time, namely the robust PCA (principal component analysis)-based 4D CT model. That is, instead of viewing the 4D object as a temporal collection of three-dimensional (3D) images and looking for local coherence in time or space independently, we perceive it as a mixture of low-rank matrix and sparse matrix to explore the maximum temporal coherence of the spatial structure among phases. Here the low-rank matrix corresponds to the 'background' or reference state, which is stationary over time or similar in structure; the sparse matrix stands for the 'motion' or time-varying component, e.g., heart motion in cardiac imaging, which is often either approximately sparse itself or can be sparsified in the proper basis. Besides 4D CT, this robust PCA-based 4D CT model should be applicable in other imaging problems for motion reduction or/and change detection with the least amount of data, such as multi-energy CT, cardiac MRI, and hyperspectral imaging. (2) A dynamic strategy for data acquisition, i.e. a temporally spiral scheme, is proposed that can potentially maintain similar reconstruction accuracy with far fewer projections of the data. The key point of this dynamic scheme is to reduce the total number of measurements, and hence the radiation dose, by acquiring complementary data in different phases while reducing redundant measurements of the common background structure. (3) An accurate, efficient, yet simple-to-implement algorithm based on the split Bregman method is developed for solving the model problem with sparse representation in tight frames.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704 · cited 1×
“For comparison of models, L 2 regularization and total variation (TV) regularization (Rudin et al 1992) will be employed, i.e. the following with i the spatial index: In the second equation of (2 .”
MethodRobust principal component analysis?
Candès, E. J., Li, X., Ma, Y., & Wright, J. (2011) · Journal of the ACM · doi:10.1145/1970392.1970395 · Cited by 6,921 · cited 5×
“In Candès et al (2009), a model to recover principal component X1 (modeled by a low-rank matrix) from data X with outliers X2 (modeled by a sparse matrix) is converted to the following minimization problem when certain incoherence conditions are satisfied: (2.13) where r is shown to be the…”
BackgroundMethodInfluentialA Singular Value Thresholding Algorithm for Matrix Completion
Cai, J.-F., Candès, E. J., & Shen, Z. (2010) · SIAM Journal on Optimization · doi:10.1137/080738970 · Cited by 5,809 · cited 1×
“17) can be exactly solved by the so-called singular value thresholding (SVT) algorithm (Cai et al 2010).”
BackgroundSelf-citationNonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265 · cited 4×
“To alleviate the view-aliasing artifacts due to the reduced number of projections, the image registration based on a deformable model of respiratory motion can be used either in image space [9], or in data space with an artifact-free reference image [10].”
MethodInfluentialThe Split Bregman Method for L1-Regularized Problems
Goldstein, T., & Osher, S. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/080725891 · Cited by 4,282 · cited 2×
“…measurements of the common background structure; while being accurate, the split Bregman method offers an extremely efficient, yet simple-to-implement strategy for solving a class of general l1-type problems, including the proposed RPCA-4DCT model (Goldstein and Osher 2009, Cai et al 2009).”
MethodInfluentialSignal Recovery by Proximal Forward-Backward Splitting
Combettes, P. L., & Wajs, V. R. (2005) · Multiscale Modeling & Simulation · doi:10.1137/050626090 · Cited by 2,678 · cited 2×
“Note that if only a single iteration is used in CG, (2.17) can be viewed as a typical example of operator splitting methods (Combettes and Wajs 2005, Hale et al 2008, Zhang et al 2009).”
BackgroundMethodInfluentialAn Iterative Regularization Method for Total Variation-Based Image Restoration
Osher, S., Burger, M., Goldfarb, D., Xu, J., & Yin, W. (2005) · Multiscale Modeling & Simulation · doi:10.1137/040605412 · Cited by 1,787 · cited 2×
“16), namely split Bregman method, that is essentially equivalent to augmented Lagrangian method, however was independently developed from a different perspective to improve the ROF model [16, 45].”
MethodInfluentialRobust Subspace Segmentation by Low-Rank Representation
Liu, G., Lin, Z., & Yu, Y. H. (2010) · Cited by 1,534
Fixed-Point Continuation for $\ell_1$-Minimization: Methodology and Convergence
Hale, E. T., Yin, W., & Zhang, Y. (2008) · SIAM Journal on Optimization · doi:10.1137/070698920 · Cited by 909 · cited 1×
“Note that if only a single iteration is used in CG, (2.17) can be viewed as a typical example of operator splitting methods (Combettes and Wajs 2005, Hale et al 2008, Zhang et al 2009).”
MethodInfluentialFramelets: MRA-based constructions of wavelet frames
Daubechies, I., Han, B., Ron, A., & Shen, Z. (2003) · Applied and Computational Harmonic Analysis · doi:10.1016/s1063-5203(02)00511-0 · Cited by 752 · cited 2×
“In this study, we find that the tight frame system derived from Ron and Shen (1997) and Daubechies et al (2003) in general serves the purpose in terms of low-rank and sparse decomposition.”
BackgroundMethodSelf-citation
Cited by
Otazo, R., Candès, E., & Sodickson, D. K. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Zhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203921 · Cited by 295
Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM)
Gao, H., Yu, H., Osher, S., & Wang, G. (2011) · Inverse Problems · doi:10.1088/0266-5611/27/11/115012 · Cited by 264
Self-citationOn the Applications of Robust PCA in Image and Video Processing
Bouwmans, T., Javed, S., Zhang, H., Lin, Z., & Otazo, R. (2018) · Proceedings of the IEEE · doi:10.1109/jproc.2018.2853589 · Cited by 255
Slavakis, K., Giannakis, G. B., & Mateos, G. (2014) · IEEE Signal Processing Magazine · doi:10.1109/msp.2014.2327238 · Cited by 237
Low-Rank Modeling and Its Applications in Image Analysis
Zhou, X., Yang, C., Zhao, H., & Yu, W. (2015) · ACM Computing Surveys · doi:10.1145/2674559 · Cited by 174
“Similar methods based on low-rank modeling have also been applied to image reconstruction for other modalities such as computed tomography (CT) [Cai et al. 2012; Gao et al. 2011] and positron emission tomography (PET) [Rahmim et al. 2009].”
MethodSelf-citationDirect parametric reconstruction from undersampled (k,t)-space data in dynamic contrast enhanced MRI
Dikaios, N., Arridge, S., Hamy, V., Punwani, S., & Atkinson, D. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.05.001 · Cited by 40
Metadata
- Authors
- Gao, H., Cai, J.-F., Shen, Z., & Zhao, H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2011-05-04
- Volume
- 56
- Issue
- 11
- Pages
- 3181-3198
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2111298039
- Cited by
- 181
- References
- 40
- FWCI
- 16.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.