Robust principal component analysis-based four-dimensional computed tomography
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
The purpose of this paper for four-dimensional (4D) computed tomography (CT) is threefold. (1) A new spatiotemporal model is presented from the matrix perspective with the row dimension in space and the column dimension in time, namely the robust PCA (principal component analysis)-based 4D CT model. That is, instead of viewing the 4D object as a temporal collection of three-dimensional (3D) images and looking for local coherence in time or space independently, we perceive it as a mixture of low-rank matrix and sparse matrix to explore the maximum temporal coherence of the spatial structure among phases. Here the low-rank matrix corresponds to the 'background' or reference state, which is stationary over time or similar in structure; the sparse matrix stands for the 'motion' or time-varying component, e.g., heart motion in cardiac imaging, which is often either approximately sparse itself or can be sparsified in the proper basis. Besides 4D CT, this robust PCA-based 4D CT model should be applicable in other imaging problems for motion reduction or/and change detection with the least amount of data, such as multi-energy CT, cardiac MRI, and hyperspectral imaging. (2) A dynamic strategy for data acquisition, i.e. a temporally spiral scheme, is proposed that can potentially maintain similar reconstruction accuracy with far fewer projections of the data. The key point of this dynamic scheme is to reduce the total number of measurements, and hence the radiation dose, by acquiring complementary data in different phases while reducing redundant measurements of the common background structure. (3) An accurate, efficient, yet simple-to-implement algorithm based on the split Bregman method is developed for solving the model problem with sparse representation in tight frames.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704 · cited 1×
“For comparison of models, L 2 regularization and total variation (TV) regularization (Rudin et al 1992) will be employed, i.e. the following with i the spatial index: In the second equation of (2 .”
MethodRobust principal component analysis?
Candès, E. J., Li, X., Ma, Y., & Wright, J. (2011) · Journal of the ACM · doi:10.1145/1970392.1970395 · Cited by 6,921 · cited 5×
“In Candès et al (2009), a model to recover principal component X1 (modeled by a low-rank matrix) from data X with outliers X2 (modeled by a sparse matrix) is converted to the following minimization problem when certain incoherence conditions are satisfied: (2.13) where r is shown to be the…”
BackgroundMethodInfluentialA Singular Value Thresholding Algorithm for Matrix Completion
Cai, J.-F., Candès, E. J., & Shen, Z. (2010) · SIAM Journal on Optimization · doi:10.1137/080738970 · Cited by 5,809 · cited 1×
“17) can be exactly solved by the so-called singular value thresholding (SVT) algorithm (Cai et al 2010).”
BackgroundSelf-citationNonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265 · cited 4×
“To alleviate the view-aliasing artifacts due to the reduced number of projections, the image registration based on a deformable model of respiratory motion can be used either in image space [9], or in data space with an artifact-free reference image [10].”
MethodInfluentialThe Split Bregman Method for L1-Regularized Problems
Goldstein, T., & Osher, S. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/080725891 · Cited by 4,282 · cited 2×
“…measurements of the common background structure; while being accurate, the split Bregman method offers an extremely efficient, yet simple-to-implement strategy for solving a class of general l1-type problems, including the proposed RPCA-4DCT model (Goldstein and Osher 2009, Cai et al 2009).”
MethodInfluentialSignal Recovery by Proximal Forward-Backward Splitting
Combettes, P. L., & Wajs, V. R. (2005) · Multiscale Modeling & Simulation · doi:10.1137/050626090 · Cited by 2,678 · cited 2×
“Note that if only a single iteration is used in CG, (2.17) can be viewed as a typical example of operator splitting methods (Combettes and Wajs 2005, Hale et al 2008, Zhang et al 2009).”
BackgroundMethodInfluentialAn Iterative Regularization Method for Total Variation-Based Image Restoration
Osher, S., Burger, M., Goldfarb, D., Xu, J., & Yin, W. (2005) · Multiscale Modeling & Simulation · doi:10.1137/040605412 · Cited by 1,787 · cited 2×
“16), namely split Bregman method, that is essentially equivalent to augmented Lagrangian method, however was independently developed from a different perspective to improve the ROF model [16, 45].”
MethodInfluentialRobust Subspace Segmentation by Low-Rank Representation
Liu, G., Lin, Z., & Yu, Y. H. (2010) · Cited by 1,534
Fixed-Point Continuation for $\ell_1$-Minimization: Methodology and Convergence
Hale, E. T., Yin, W., & Zhang, Y. (2008) · SIAM Journal on Optimization · doi:10.1137/070698920 · Cited by 909 · cited 1×
“Note that if only a single iteration is used in CG, (2.17) can be viewed as a typical example of operator splitting methods (Combettes and Wajs 2005, Hale et al 2008, Zhang et al 2009).”
MethodInfluentialFramelets: MRA-based constructions of wavelet frames
Daubechies, I., Han, B., Ron, A., & Shen, Z. (2003) · Applied and Computational Harmonic Analysis · doi:10.1016/s1063-5203(02)00511-0 · Cited by 752 · cited 2×
“In this study, we find that the tight frame system derived from Ron and Shen (1997) and Daubechies et al (2003) in general serves the purpose in terms of low-rank and sparse decomposition.”
BackgroundMethodSelf-citationAffine Systems inL2(Rd): The Analysis of the Analysis Operator
Ron, A., & Shen, Z. (1997) · Journal of Functional Analysis · doi:10.1006/jfan.1996.3079 · Cited by 694 · cited 2×
“Here the image sparsity is enforced in the wavelet tight frame domain rather than itself (Ron and Shen 1997).”
BackgroundMethodSelf-citationBregmanized Nonlocal Regularization for Deconvolution and Sparse Reconstruction
Zhang, X., Burger, M., Bresson, X., & Osher, S. (2010) · SIAM Journal on Imaging Sciences · doi:10.1137/090746379 · Cited by 688 · cited 1×
“17) can be viewed as a typical example of operator splitting methods (Combettes and Wajs 2005, Hale et al 2008, Zhang et al 2009).”
MethodSplit Bregman Methods and Frame Based Image Restoration
Cai, J.-F., Osher, S., & Shen, Z. (2010) · Multiscale Modeling & Simulation · doi:10.1137/090753504 · Cited by 670 · cited 4×
“In particular, the tight frame regularized split Bregman method is implemented here (Cai et al 2009).”
MethodInfluentialSelf-citationAspects of Total Variation Regularized L1Function Approximation
Chan, T. F., & Esedoglu, S. (2005) · SIAM Journal on Applied Mathematics · doi:10.1137/040604297 · Cited by 651 · cited 1×
“For example, if the data come with impulse noise, l 1 norm is particularly suitable for characterizing such outliers (Alliney 1992, Nikolova 2002, Chan and Esedoglu 2005, Gao and Zhao 2010).”
BackgroundComputed Tomography From Photon Statistics to Modern Cone-Beam CT
Mihailidis, D. N. (2009) · Medical Physics · doi:10.1118/1.3176026 · Cited by 583
Pan, X., Sidky, E. Y., & Vannier, M. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123009 · Cited by 572 · cited 2×
“Tremendous effort has been devoted to dose reduction (Xing et al 2006, Jiang et al 2008, Pan et al 2009, Fahimian et al 2010, Wang et al 2010).”
BackgroundRobust video denoising using low rank matrix completion
Ji, H., Liu, C., Shen, Z., & Xu, Y. (2010) · 2010 IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2010.5539849 · Cited by 483 · cited 2×
“The similar models have been considered in several applications, such as video surveillance (Cand ` es et al 2009), face recognition (Cand ` es et al 2009), video denoising (Ji et al 2010), and others (Peng et al 2010, Liu et al 2010, Min et al 2010, Zhu et al 2010, Zhang et al 2010, Wu et al 2010).”
BackgroundMethodSelf-citationLow, D. A., Nystrom, M., Kalinin, E., Parikh, P., Dempsey, J. F., Bradley, J. D., Mutic, S., Wahab, S. H., Islam, T., Christensen, G., et al. (2003) · Medical Physics · doi:10.1118/1.1576230 · Cited by 475 · cited 1×
“With time-resolved data acquisition, four-dimensional (4D) CT possesses an unprecedented capability for accurate patient imaging and treatment planning in spite of organ / tumor motion (Vedam et al 2003, Low et al 2003, Keall et al 2004, Rietzel et al 2005, Li et al 2005).”
MethodOverview of image-guided radiation therapy
Xing, L., Thorndyke, B., Schreibmann, E., Yang, Y., Li, T.-F., Kim, G.-Y., Luxton, G., & Koong, A. (2006) · Medical Dosimetry · doi:10.1016/j.meddos.2005.12.004 · Cited by 468 · cited 2×
“Tremendous effort has been devoted to dose reduction (Xing et al 2006, Jiang et al 2008, Pan et al 2009, Fahimian et al 2010, Wang et al 2010).”
BackgroundAcquiring 4D thoracic CT scans using a multislice helical method
Keall, P. J., Starkschall, G., Shukla, H., Forster, K. M., Ortiz, V, Stevens, C. W., Vedam, S. S., George, R., Guerrero, T., & Mohan, R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/10/015 · Cited by 399 · cited 1×
“With time-resolved data acquisition, four-dimensional (4D) CT possesses an unprecedented capability for accurate patient imaging and treatment planning in spite of organ / tumor motion (Vedam et al 2003, Low et al 2003, Keall et al 2004, Rietzel et al 2005, Li et al 2005).”
MethodNational Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O. W., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 380 · cited 2×
“…it has been estimated that although CT studies constitute only 4% of all radiological procedures, they account for 40% of the radiation dose delivered (Shrimpton and Edyvean 1998); furthermore, ‘CT could account for as much as 60% of manmade radiation exposures to Americans’ (Linton et al 2003).”
BackgroundA framelet-based image inpainting algorithm
Cai, J.-F., Chan, R. H., & Shen, Z. (2008) · Applied and Computational Harmonic Analysis · doi:10.1016/j.acha.2007.10.002 · Cited by 338 · cited 2×
“In this study, a multilevel tight framelet decomposition without downsampling under the Neumann (symmetric) boundary condition is used with piecewise linear framelets (Chai and Shen 2007, Cai et al 2008).”
MethodSelf-citationNikolova, M. (2002) · SIAM Journal on Numerical Analysis · doi:10.1137/s0036142901389165 · Cited by 326 · cited 2×
“For example, if the data come with impulse noise, l 1 norm is particularly suitable for characterizing such outliers (Alliney 1992, Nikolova 2002, Chan and Esedoglu 2005, Gao and Zhao 2010).”
BackgroundRobust Photometric Stereo via Low-Rank Matrix Completion and Recovery
Wu, L., Ganesh, A., Shi, B., Matsushita, Y., Wang, Y., & Ma, Y. (2011) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-19318-7_55 · Cited by 298 · cited 1×
“The similar models have been considered in several applications, such as video surveillance (Cand ` es et al 2009), face recognition (Cand ` es et al 2009), video denoising (Ji et al 2010), and others (Peng et al 2010, Liu et al 2010, Min et al 2010, Zhu et al 2010, Zhang et al 2010, Wu et al 2010).”
MethodVariational Optic Flow Computation with a Spatio-Temporal Smoothness Constraint
Weickert, J., & Schnörr, C. (2001) · Journal of Mathematical Imaging and Vision · doi:10.1023/a:1011286029287 · Cited by 247
Image tag refinement towards low-rank, content-tag prior and error sparsity
Zhu, G., Yan, S., & Ma, Y. (2010) · Proceedings of the 18th ACM international conference on Multimedia · doi:10.1145/1873951.1874028 · Cited by 243 · cited 2×
“The similar models have been considered in several applications, such as video surveillance (Candès et al 2009), face recognition (Candès et al 2009), video denoising (Ji et al 2010), and others (Peng et al 2010, Liu et al 2010, Min et al 2010, Zhu et al 2010, Zhang et al 2010, Wu et al 2010).”
BackgroundMethodRASL: Robust alignment by sparse and low-rank decomposition for linearly correlated images
Peng, Y., Ganesh, A., Wright, J., Xu, W., & Ma, Y. (2010) · 2010 IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2010.5540138 · Cited by 242 · cited 1×
“The similar models have been considered in several applications, such as video surveillance (Cand ` es et al 2009), face recognition (Cand ` es et al 2009), video denoising (Ji et al 2010), and others (Peng et al 2010, Liu et al 2010, Min et al 2010, Zhu et al 2010, Zhang et al 2010, Wu et al 2010).”
MethodRobust Video Restoration by Joint Sparse and Low Rank Matrix Approximation
Ji, H., Huang, S., Shen, Z., & Xu, Y. (2011) · SIAM Journal on Imaging Sciences · doi:10.1137/100817206 · Cited by 192 · cited 1×
“Consequently, the overall reconstruction is with respect to the weighted sum of 4D components [36].”
BackgroundSelf-citationShrimpton, P. C., & Edyvean, S. (1998) · The British Journal of Radiology · doi:10.1259/bjr.71.841.9534691 · Cited by 190 · cited 1×
“…it has been estimated that although CT studies constitute only 4% of all radiological procedures, they account for 40% of the radiation dose delivered (Shrimpton and Edyvean 1998); furthermore, ‘CT could account for as much as 60% of manmade radiation exposures to Americans’ (Linton et al 2003).”
BackgroundA General Local Reconstruction Approach Based on a Truncated Hilbert Transform
Ye, Y., Yu, H., Wei, Y., & Wang, G. (2007) · International Journal of Biomedical Imaging · doi:10.1155/2007/63634 · Cited by 176 · cited 1×
“…justified methodology, ‘interior tomography’, an internal region of interest (ROI) can be exactly reconstructed only from local projection data directly associated with this ROI, which would conventionally require the whole body x-ray illumination (Wang et al 2010, Ye et al 2007, Kudo et al 2008).”
Nehmeh, S. A., Erdi, Y. E., Rosenzweig, K. E., Schöder, H. M., Larson, S. M., Squire, O. D., & Humm, J. L. (2003) · PubMed · Cited by 170
Enhanced 4D cone‐beam CT with inter‐phase motion model
Li, T., Koong, A. C., & Xing, L. (2007) · Medical Physics · doi:10.1118/1.2767144 · Cited by 136 · cited 2×
“To alleviate the view-aliasing artifacts due to the reduced number of projections, the image registration based on a deformable model of respiratory motion can be used either in image space (Rueckert et al 1999) or in data space with an artifact-free reference image (Li et al 2007).”
MethodDigital filters as absolute norm regularizers
Alliney, S. (1992) · IEEE Transactions on Signal Processing · doi:10.1109/78.139258 · Cited by 116 · cited 2×
“For example, if the data come with impulse noise, l 1 norm is particularly suitable for characterizing such outliers (Alliney 1992, Nikolova 2002, Chan and Esedoglu 2005, Gao and Zhao 2010).”
BackgroundTILT: Transform Invariant Low-Rank Textures
Zhang, Z., Liang, X., Ganesh, A., & Ma, Y. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-19318-7_25 · Cited by 100
Deconvolution: a wavelet frame approach
Chai, A., & Shen, Z. (2007) · Numerische Mathematik · doi:10.1007/s00211-007-0075-0 · Cited by 99 · cited 2×
“In this study, a multilevel tight framelet decomposition without downsampling under the Neumann (symmetric) boundary condition is used with piecewise linear framelets (Chai and Shen 2007, Cai et al 2008).”
MethodSelf-citationRadiation dose reduction in four‐dimensional computed tomography
Li, T., Schreibmann, E., Thorndyke, B., Tillman, G., Boyer, A. L., Koong, A. C., Goodman, K. A., & Xing, L. (2005) · Medical Physics · doi:10.1118/1.2122567 · Cited by 82 · cited 1×
“With time-resolved data acquisition, four-dimensional (4D) CT possesses an unprecedented capability for accurate patient imaging and treatment planning in spite of organ / tumor motion (Vedam et al 2003, Low et al 2003, Keall et al 2004, Rietzel et al 2005, Li et al 2005).”
MethodFast singular value thresholding without singular value decomposition
Cai, J., & Osher, S. (2013) · Methods and Applications of Analysis · doi:10.4310/maa.2013.v20.n4.a2 · Cited by 69 · cited 1×
“In the case of a large number of phases, the fast SVT without SVD can be used (Cai and Osher 2010).”
MethodSelf-citationLow-dose x-ray phase-contrast and absorption CT using equally sloped tomography
Fahimian, B., Mao, Y. L., Cloetens, P., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/18/008 · Cited by 47 · cited 1×
“Tremendous effort has been devoted to dose reduction (Xing et al 2006, Jiang et al 2008, Pan et al 2009, Fahimian et al 2010, Wang et al 2010).”
BackgroundA knowledge‐based cone‐beam x‐ray CT algorithm for dynamic volumetric cardiac imaging
Wang, G., Zhao, S., & Heuscher, D. J. (2002) · Medical Physics · doi:10.1118/1.1494989 · Cited by 42 · cited 1×
“The cardiac phases are generated according to the model proposed in Wang et al (2002).”
MethodFour-Dimensional Image Registration for Image-Guided Radiotherapy
Schreibmann, E., Thorndyke, B., Li, T., Wang, J., & Xing, L. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.01.042 · Cited by 27 · cited 2×
“The similar ideas also appear in other 4D imaging techniques [11], such as 4D positron emission tomography (PET) [12].”
Background
Cited by
Otazo, R., Candès, E., & Sodickson, D. K. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25240 · Cited by 697
Zhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203921 · Cited by 295
Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM)
Gao, H., Yu, H., Osher, S., & Wang, G. (2011) · Inverse Problems · doi:10.1088/0266-5611/27/11/115012 · Cited by 264
Self-citationOn the Applications of Robust PCA in Image and Video Processing
Bouwmans, T., Javed, S., Zhang, H., Lin, Z., & Otazo, R. (2018) · Proceedings of the IEEE · doi:10.1109/jproc.2018.2853589 · Cited by 255
Slavakis, K., Giannakis, G. B., & Mateos, G. (2014) · IEEE Signal Processing Magazine · doi:10.1109/msp.2014.2327238 · Cited by 237
Metadata
- Authors
- Gao, H., Cai, J.-F., Shen, Z., & Zhao, H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2011-05-04
- Volume
- 56
- Issue
- 11
- Pages
- 3181-3198
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2111298039
- Cited by
- 181
- References
- 40
- FWCI
- 16.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.