Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
The tracer-kinetic models developed in the early 1990s for dynamic contrast-enhanced MRI (DCE-MRI) have since become a standard in numerous applications. At the same time, the development of MRI hardware has led to increases in image quality and temporal resolution that reveal the limitations of the early models. This in turn has stimulated an interest in the development and application of a second generation of modelling approaches. They are designed to overcome these limitations and produce additional and more accurate information on tissue status. In particular, models of the second generation enable separate estimates of perfusion and capillary permeability rather than a single parameter K(trans) that represents a combination of the two. A variety of such models has been proposed in the literature, and development in the field has been constrained by a lack of transparency regarding terminology, notations and physiological assumptions. In this review, we provide an overview of these models in a manner that is both physically intuitive and mathematically rigourous. All are derived from common first principles, using concepts and notations from general tracer-kinetic theory. Explicit links to their historical origins are included to allow for a transfer of experience obtained in other fields (PET, SPECT, CT). A classification is presented that reveals the links between all models, and with the models of the first generation. Detailed formulae for all solutions are provided to facilitate implementation. Our aim is to encourage the application of these tools to DCE-MRI by offering researchers a clearer understanding of their assumptions and requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data
Patlak, C. S., Blasberg, R. G., & Fenstermacher, J. D. (1983) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1983.1 · Cited by 3,567
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Self-citationModeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Tofts, P. S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070113 · Cited by 1,478
Tofts, P. S., & Kermode, A. G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170208 · Cited by 1,456
Textbook of Medical Physiology
Iatridis, P. G. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03470200123049 · Cited by 1,275
Compartmental analysis in Biology and Medicine
Anderson, D. H. (1986) · Mathematical Biosciences · doi:10.1016/0025-5564(86)90168-9 · Cited by 988
Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles
Renkin, E. M. (1959) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1959.197.6.1205 · Cited by 723
Boxerman, J. L., Schmainda, K. M., & Weisskoff, R. M. (2006) · PubMed · Cited by 686
Parker, G. J. M., Roberts, C., Macdonald, A., Buonaccorsi, G. A., Cheung, S., Buckley, D. L., Jackson, A., Watson, Y., Davies, K., & Jayson, G. C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21066 · Cited by 660
Self-citationPharmacokinetic Parameters in CNS Gd-DTPA Enhanced MR Imaging
Brix, G., Semmler, W., Port, R., Schad, L. R., Layer, G., & Lorenz, W. J. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199107000-00018 · Cited by 659
Cited by
Classic models for dynamic contrast‐enhanced MRI
Sourbron, S. P., & Buckley, D. L. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2940 · Cited by 434
Self-citationHeye, A. K., Culling, R. D., Valdés Hernández, M. D. C., Thrippleton, M. J., & Wardlaw, J. M. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.09.002 · Cited by 406
Models and methods for analyzing DCE‐MRI: A review
Khalifa, F., Soliman, A., El‐Baz, A., Abou El‐Ghar, M., El‐Diasty, T., Gimel'farb, G., Ouseph, R., & Dwyer, A. C. (2014) · Medical Physics · doi:10.1118/1.4898202 · Cited by 322
Perfusion and vascular permeability: Basic concepts and measurement in DCE-CT and DCE-MRI
Cuenod, C. A., & Balvay, D. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.10.010 · Cited by 312
Thrippleton, M. J., Backes, W. H., Sourbron, S., Ingrisch, M., van Osch, M. J. P., Dichgans, M., Fazekas, F., Ropele, S., Frayne, R., van Oostenbrugge, R. J., et al. (2019) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2019.01.013 · Cited by 252
“Several pharmacokinetic models are commonly used to analyze DCE-MRI images in a range of tissues and pathologies, and it is critical to select amodel appropriate to the acquisition protocol, the tissue microstructure, and the likely ranges of the pharmacokinetic parameters [7,8,83].”
Self-citationCardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
“Choice of acquisition pulse sequence In DCE-MRI the image appearance changes significantly between contiguous frames due to the passage of the contrast agent through the heart so multi-shot k-space imaging strategies that fill k-space over multiple cardiac cycles [1] are not applicable.”
InfluentialCT Perfusion of the Liver: Principles and Applications in Oncology
Kim, S. H., Kamaya, A., & Willmann, J. K. (2014) · Radiology · doi:10.1148/radiol.14130091 · Cited by 200
“To obtain additional perfusion parameters, several kinetic model-based approaches have been developed (39,40).”
MethodTracer kinetic modelling for DCE-MRI quantification of subtle blood–brain barrier permeability
Heye, A. K., Thrippleton, M. J., Armitage, P. A., Valdés Hernández, M. D. C., Makin, S. D., Glatz, A., Sakka, E., & Wardlaw, J. M. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.018 · Cited by 187
“We obtained a vascular input function (VIF) from a voxel located on the superior sagittal sinus (SS) since partial volume effects and inflow artefact were reduced at that location compared with obtaining the AIF from a feeding artery (Lavini and Verhoeff, 2010); the delay between arterial and venous responses is expec…”
BackgroundMethodRamamonjisoa, N., & Ackerstaff, E. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00003 · Cited by 93
“, are either derived from semiquantitative measures of signal enhancement (220, 239–241) or from pharmacokinetic modeling of signal-versus-time curves (222, 242) with the underlying principle based on standard tracerkinetic theory of linear and stationary systems (221, 243) and the model adjusted to account for variat…”
Method
Metadata
- Authors
- Sourbron, S. P., & Buckley, D. L.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2011-12-15
- Volume
- 57
- Issue
- 2
- Pages
- R1-R33
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2074145540
- Cited by
- 361
- References
- 58
- FWCI
- 21.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.