Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
The tracer-kinetic models developed in the early 1990s for dynamic contrast-enhanced MRI (DCE-MRI) have since become a standard in numerous applications. At the same time, the development of MRI hardware has led to increases in image quality and temporal resolution that reveal the limitations of the early models. This in turn has stimulated an interest in the development and application of a second generation of modelling approaches. They are designed to overcome these limitations and produce additional and more accurate information on tissue status. In particular, models of the second generation enable separate estimates of perfusion and capillary permeability rather than a single parameter K(trans) that represents a combination of the two. A variety of such models has been proposed in the literature, and development in the field has been constrained by a lack of transparency regarding terminology, notations and physiological assumptions. In this review, we provide an overview of these models in a manner that is both physically intuitive and mathematically rigourous. All are derived from common first principles, using concepts and notations from general tracer-kinetic theory. Explicit links to their historical origins are included to allow for a transfer of experience obtained in other fields (PET, SPECT, CT). A classification is presented that reveals the links between all models, and with the models of the first generation. Detailed formulae for all solutions are provided to facilitate implementation. Our aim is to encourage the application of these tools to DCE-MRI by offering researchers a clearer understanding of their assumptions and requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data
Patlak, C. S., Blasberg, R. G., & Fenstermacher, J. D. (1983) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1983.1 · Cited by 3,567
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Self-citationModeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Tofts, P. S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070113 · Cited by 1,478
Tofts, P. S., & Kermode, A. G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170208 · Cited by 1,456
Textbook of Medical Physiology
Iatridis, P. G. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03470200123049 · Cited by 1,275
Compartmental analysis in Biology and Medicine
Anderson, D. H. (1986) · Mathematical Biosciences · doi:10.1016/0025-5564(86)90168-9 · Cited by 988
Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles
Renkin, E. M. (1959) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1959.197.6.1205 · Cited by 723
Boxerman, J. L., Schmainda, K. M., & Weisskoff, R. M. (2006) · PubMed · Cited by 686
Parker, G. J. M., Roberts, C., Macdonald, A., Buonaccorsi, G. A., Cheung, S., Buckley, D. L., Jackson, A., Watson, Y., Davies, K., & Jayson, G. C. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21066 · Cited by 660
Self-citationPharmacokinetic Parameters in CNS Gd-DTPA Enhanced MR Imaging
Brix, G., Semmler, W., Port, R., Schad, L. R., Layer, G., & Lorenz, W. J. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199107000-00018 · Cited by 659
Rempp, K. A., Brix, G., Wenz, F., Becker, C. R., Gückel, F., & Lorenz, W. J. (1994) · Radiology · doi:10.1148/radiology.193.3.7972800 · Cited by 639
Tracer kinetic methods in medical physiology
Lassen, N. A., & Perl, W. (1979) · Raven Press eBooks · Cited by 540
Leach, M. O., Brindle, K. M., Evelhoch, J. L., Griffiths, J. R., Horsman, M. R., Jackson, A., Jayson, G. C., Judson, I. R., Knopp, M. V., Maxwell, R. J., et al. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602550 · Cited by 513
DCE-MRI biomarkers in the clinical evaluation of antiangiogenic and vascular disrupting agents
O'Connor, J. P. B., Jackson, A., Parker, G. J. M., & Jayson, G. C. (2007) · British Journal of Cancer · doi:10.1038/sj.bjc.6603515 · Cited by 484
Calamante, F., Gadian, D. G., & Connelly, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<466::aid-mrm18>3.0.co;2-m · Cited by 458
Larsson, H. B. W., Stubgaard, M., Frederiksen, J. L., Jensen, M., Henriksen, O., & Paulson, O. B. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160111 · Cited by 431
Perfusion CT: a worthwhile enhancement?
Miles, K. A., & Griffiths, M. R. (2003) · The British Journal of Radiology · doi:10.1259/bjr/13564625 · Cited by 392
On the scope and interpretation of the Tofts models for DCE‐MRI
Sourbron, S. P., & Buckley, D. L. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22861 · Cited by 371
Self-citationOn the Uptake of Materials by the Intact Liver. THE TRANSPORT AND NET REMOVAL OF GALACTOSE
Goresky, C. A., Bach, G. G., & Nadeau, B. E. (1973) · Journal of Clinical Investigation · doi:10.1172/jci107300 · Cited by 291
Principles of cerebral perfusion imaging by bolus tracking
Østergaard, L. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20460 · Cited by 289
Sourbron, S., Ingrisch, M., Siefert, A., Reiser, M., & Herrmann, K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22005 · Cited by 276
Self-citationSahani, D. V., Kalva, S. P., Hamberg, L. M., Hahn, P. F., Willett, C. G., Saini, S., Mueller, P. R., & Lee, T.-Y. (2005) · Radiology · doi:10.1148/radiol.2343040286 · Cited by 276
Water diffusion and exchange as they influence contrast enhancement
Donahue, K. M., Weisskoff, R. M., & Burstein, D. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070114 · Cited by 270
Temporal sampling requirements for the tracer kinetics modeling of breast disease
Henderson, E., Rutt, B. K., & Lee, T.-Y. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00130-1 · Cited by 263
Brix, G., Kiessling, F., Lucht, R., Darai, S., Wasser, K., Delorme, S., & Griebel, J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20161 · Cited by 252
A model for capillary exchange
Johnson, J., & Wilson, T. (1966) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1966.210.6.1299 · Cited by 248
Assessment of hepatic perfusion parameters with dynamic MRI
Materne, R., Smith, A. M., Peeters, F., Dehoux, J. P., Keyeux, A., Horsmans, Y., & Van Beers, B. E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10045 · Cited by 226
Larsson, H. B. W., Courivaud, F., Rostrup, E., & Hansen, A. E. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22136 · Cited by 224
Schabel, M. C., & Parker, D. L. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/9/010 · Cited by 221
Modelling amyloid fibril formation kinetics: mechanisms of nucleation and growth
Gillam, J. E., & MacPhee, C. E. (2013) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/25/37/373101 · Cited by 215
Brix, G., Bahner, M. L., Hoffmann, U., Horváth, A., & Schreiber, W. (1999) · Radiology · doi:10.1148/radiology.210.1.r99ja46269 · Cited by 186
O’Connor, J. P. B., Carano, R. A. D., Clamp, A. R., Ross, J., Ho, C., Jackson, A., Parker, G. J. M., Rose, C. J., Peale, F. V., Jr., Friesenhahn, M. J., et al. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-09-0731 · Cited by 167
Molecular modeling of protein materials: case study of elastin
Tarakanova, A., & Buehler, M. J. (2013) · Modelling and Simulation in Materials Science and Engineering · doi:10.1088/0965-0393/21/6/063001 · Cited by 160
Ewing, J. R., Brown, S. L., Lu, M., Panda, S., Ding, G., Knight, R. A., Cao, Y., Jiang, Q., Nagaraja, T. N., Churchman, J. L., et al. (2006) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600189 · Cited by 130
Brix, G., Griebel, J., Kiessling, F. M., & Wenz, F. K. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1448-7 · Cited by 124
Lawrence, K. S., Frank, J. A., & McLaughlin, A. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200009)44:3<440::aid-mrm15>3.0.co;2-6 · Cited by 108
Kershaw, L. E., & Buckley, D. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21040 · Cited by 96
Self-citationBassingthwaighte, J. B., Chan, I. S., & Wang, C. Y. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368613 · Cited by 92
Temporal resolution and SNR requirements for accurate DCE‐MRI data analysis using the AATH model
Kershaw, L. E., & Cheng, H. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22573 · Cited by 91
Bolus dynamics: theoretical and experimental aspects.
Blomley, M. J. K., & Dawson, P. (1997) · British Journal of Radiology · doi:10.1259/bjr.70.832.9166070 · Cited by 85
Brix, G., Zwick, S., Kiessling, F. M., & Griebel, J. (2009) · Medical Physics · doi:10.1118/1.3147145 · Cited by 78
Larsson, H. B. W., & Tofts, P. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240119 · Cited by 78
Donaldson, S. B., Betts, G. N. J., Bonington, S. C., Homer, J. J., Slevin, N. J., Kershaw, L. E., Valentine, H. R., West, C., & Buckley, D. L. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.09.039 · Cited by 77
Self-citationRoberts, C., Little, R. A., Watson, Y., Zhao, S., Buckley, D. L., & Parker, G. J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22593 · Cited by 77
Self-citationProteins as specific polar media for charge transfer processes
Krishtalik, L. I. (2012) · Physics-Uspekhi · doi:10.3367/ufne.0182.201212b.1275 · Cited by 72
On the identifiability of pharmacokinetic parameters in dynamic contrast‐enhanced imaging
Lopata, R. G. P., Backes, W. H., van den Bosch, P. P. J., & van Riel, N. A. W. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21336 · Cited by 62
Schabel, M. C., DiBella, E., Jensen, R. L., & Salzman, K. L. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/16/012 · Cited by 61
Imaging vascular physiology to monitor cancer treatment
Laking, G. R., West, C., Buckley, D. L., Matthews, J. C., & Price, P. (2006) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2005.10.006 · Cited by 58
Self-citationPeeters, F., Annet, L., Hermoye, L., & BEERS, B. E. V. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20032 · Cited by 55
Garpebring, A., Wirestam, R., Östlund, N., & Karlsson, M. C. F. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22760 · Cited by 52
Validity of perfusion parameters obtained using the modified Tofts model: A simulation study
Luypaert, R., Sourbron, S. P., & Mey, J. D. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22728 · Cited by 52
Self-citationde BAZELAIRE, C., Siauve, N., Fournier, L. S., Frouin, F., Robert, P., Clémеnt, O., de Kerviler, É., & Cuénod, C. A. (2005) · European Radiology · doi:10.1007/s00330-005-2873-z · Cited by 50
Quarles, R. P., Mintun, M. A., Larson, K. B., Markham, J., MacLeod, A. M., & Raichle, M. E. (1993) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1993.94 · Cited by 47
Bolus‐tracking MRI with a simultaneous T1‐ and T‐measurement
Sourbron, S. P., Heilmann, M., Biffar, A., Walczak, C., Vautier, J., Volk, A., & Peller, M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22042 · Cited by 42
Self-citationDynamic contrast-enhanced MR imaging to assess physiologic variations of myometrial perfusion
Thomassin‐Naggara, I., Balvay, D., Cuénod, C. A., Daraï, É., Marsault, C., & Bazot, M. (2009) · European Radiology · doi:10.1007/s00330-009-1621-1 · Cited by 41
Luypaert, R., Sourbron, S. P., Makkat, S., & Mey, J. D. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/21/006 · Cited by 32
Self-citationMichoux, N., Huwart, L., Abarca‐Quinones, J., Dorvillius, M., Annet, L., Peeters, F., & BEERS, B. E. V. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21524 · Cited by 27
Artifacts and pitfalls in diffusion MR imaging
Koch, M., & Norris, D. G. (2004) · Cambridge University Press eBooks · doi:10.1017/cbo9780511544958.008 · Cited by 6
Cited by
Classic models for dynamic contrast‐enhanced MRI
Sourbron, S. P., & Buckley, D. L. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2940 · Cited by 434
Self-citationHeye, A. K., Culling, R. D., Valdés Hernández, M. D. C., Thrippleton, M. J., & Wardlaw, J. M. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.09.002 · Cited by 406
Models and methods for analyzing DCE‐MRI: A review
Khalifa, F., Soliman, A., El‐Baz, A., Abou El‐Ghar, M., El‐Diasty, T., Gimel'farb, G., Ouseph, R., & Dwyer, A. C. (2014) · Medical Physics · doi:10.1118/1.4898202 · Cited by 322
Perfusion and vascular permeability: Basic concepts and measurement in DCE-CT and DCE-MRI
Cuenod, C. A., & Balvay, D. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.10.010 · Cited by 312
Thrippleton, M. J., Backes, W. H., Sourbron, S., Ingrisch, M., van Osch, M. J. P., Dichgans, M., Fazekas, F., Ropele, S., Frayne, R., van Oostenbrugge, R. J., et al. (2019) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2019.01.013 · Cited by 252
“Several pharmacokinetic models are commonly used to analyze DCE-MRI images in a range of tissues and pathologies, and it is critical to select amodel appropriate to the acquisition protocol, the tissue microstructure, and the likely ranges of the pharmacokinetic parameters [7,8,83].”
Self-citation
Metadata
- Authors
- Sourbron, S. P., & Buckley, D. L.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2011-12-15
- Volume
- 57
- Issue
- 2
- Pages
- R1-R33
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2074145540
- Cited by
- 361
- References
- 58
- FWCI
- 21.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.