Iterative image reconstruction for cerebral perfusion CT using a pre-contrast scan induced edge-preserving prior
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Cerebral perfusion x-ray computed tomography (PCT) imaging, which detects and characterizes the ischemic penumbra, and assesses blood-brain barrier permeability with acute stroke or chronic cerebrovascular diseases, has been developed extensively over the past decades. However, due to its sequential scan protocol, the associated radiation dose has raised significant concerns to patients. Therefore, in this study we developed an iterative image reconstruction algorithm based on the maximum a posterior (MAP) principle to yield a clinically acceptable cerebral PCT image with lower milliampere-seconds (mA s). To preserve the edges of the reconstructed image, an edge-preserving prior was designed using a normal-dose pre-contrast unenhanced scan. For simplicity, the present algorithm was termed as 'MAP-ndiNLM'. Evaluations with the digital phantom and the simulated low-dose clinical brain PCT datasets clearly demonstrate that the MAP-ndiNLM method can achieve more significant gains than the existing FBP and MAP-Huber algorithms with better image noise reduction, low-contrast object detection and resolution preservation. More importantly, the MAP-ndiNLM method can yield more accurate kinetic enhanced details and diagnostic hemodynamic parameter maps than the MAP-Huber method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Non-Local Algorithm for Image Denoising
Buades, A., Coll, B., & Morel, J.-M. (2005) · 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) · doi:10.1109/cvpr.2005.38 · Cited by 7,616 · cited 1×
“The notation ‖·‖2,α denotes a Gaussian-weighted Euclidean distance between two similarity patch-windows, where α is the standard deviation of the Gaussian function (Buades et al 2005).”
BackgroundROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642 · cited 1×
“In practice, a variety of pairs of true positive fraction (TPF) and false positive fraction (FPF) can be first generated, and then an ROC curve can be drawn or fitted from the obtained TPF and FPF (Metz 1986).”
An Optimized Blockwise Non Local Means Denoising Filter for 3D Magnetic Resonance Images
Barillot, C., Inserm, H. I., & Barillot, C. (2007) · Cited by 1,211
A generalized Gaussian image model for edge-preserving MAP estimation
Bouman, C., & Sauer, K. (1993) · IEEE Transactions on Image Processing · doi:10.1109/83.236536 · Cited by 884 · cited 2×
“Specifically, in this study, to preserve edges in the reconstructed image, the following potential function is adopted (Bouman and Sauer 1993): φp(t) = ‖t‖pp 1 p 2, (9) where ‖·‖p denotes the p-norm of the discrete magnitude of the image and p can be regarded as a shape factor which controls…”
MethodComputed Tomography and Radiation Risks: What Pediatric Health Care Providers Should Know
Frush, D. P., Donnelly, L. F., & Rosen, N. S. (2003) · Pediatrics · doi:10.1542/peds.112.4.951 · Cited by 625
Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography
Sukovic, P., & Clinthorne, N. H. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.896783 · Cited by 552
Wang, J., Li, T., Lu, H., & Liang, Z. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.882141 · Cited by 533 · cited 2×
“To address this problem, several approaches are proposed (Wang et al 2006, Han et al 2011).”
MethodSelf-citationAddition of a channel mechanism to the ideal-observer model
Myers, K. J., & Barrett, H. H. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.002447 · Cited by 400
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395 · cited 2×
“Up to now, many considerable efforts to reduce the radiation dose in PCT have been performed and several related techniques have been developed (Fleischmann et al 2000, Wintermark et al 2000, Wiesmann et al 2008, Yu et al 2009b Badea et al 2011, Jia et al 2010).”
BackgroundMethodCerebral Perfusion CT: Technique and Clinical Applications
Hoeffner, E. G., Case, I., Jain, R., Gujar, S. K., Shah, G. V., Deveikis, J. P., Carlos, R. C., Thompson, B. G., Harrigan, M. R., & Mukherji, S. K. (2004) · Radiology · doi:10.1148/radiol.2313021488 · Cited by 384
Cited by
Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural Network
Chen, H., Zhang, Y., Kalra, M. K., Lin, F., Chen, Y., Liao, P., Zhou, J., & Wang, G. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2715284 · Cited by 1,866
aLow-dose CT via convolutional neural network
Chen, H., Zhang, Y., Zhang, W., Liao, P., Li, K., Zhou, J., & Wang, G. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000679 · Cited by 755
Li, M., Hsu, W., Xie, X., Cong, J., & Gao, W. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2968472 · Cited by 321
Sparse-view x-ray CT reconstruction via total generalized variation regularization
Niu, S., Gao, Y., Bian, Z., Huang, J., Chen, W., Yu, G., Liang, Z., & Ma, J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/12/2997 · Cited by 291
Self-citation
Metadata
- Authors
- Ma, J., Zhang, H., Gao, Y., Huang, J., Liang, Z., Feng, Q., & Chen, W.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-10-26
- Volume
- 57
- Issue
- 22
- Pages
- 7519-7542
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2072652205
- Cited by
- 163
- References
- 29
- FWCI
- 6.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.