Model-based elastography: a survey of approaches to the inverse elasticity problem
Open accessThe DOI matches its Crossref record; 99 of the 99 references it cites were found in a registry or an index.
Abstract
Elastography is emerging as an imaging modality that can distinguish normal versus diseased tissues via their biomechanical properties. This paper reviews current approaches to elastography in three areas--quasi-static, harmonic and transient--and describes inversion schemes for each elastographic imaging approach. Approaches include first-order approximation methods; direct and iterative inversion schemes for linear elastic; isotropic materials and advanced reconstruction methods for recovering parameters that characterize complex mechanical behavior. The paper's objective is to document efforts to develop elastography within the framework of solving an inverse problem, so that elastography may provide reliable estimates of shear modulus and other mechanical parameters. We discuss issues that must be addressed if model-based elastography is to become the prevailing approach to quasi-static, harmonic and transient elastography: (1) developing practical techniques to transform the ill-posed problem with a well-posed one; (2) devising better forward models to capture the complex mechanical behavior of soft tissues and (3) developing better test procedures to evaluate the performance of modulus elastograms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Timoshenko, S. P., & Goodier, J. N. (1934) · Virtual Defense Library (Ministerio de Defensa) · Cited by 13,717
Gmsh: A 3‐D finite element mesh generator with built‐in pre‐ and post‐processing facilities
Geuzaine, C., & Remacle, J. (2009) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.2579 · Cited by 7,814
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Concepts and Applications of Finite Element Analysis
Cook, R. D., Malkus, D. S., Plesha, M. E., & Witt, R. J. (1974) · UCLA Biblioteca de Ingenieria Civil · Cited by 5,000
Concepts and applications of finite element analysis
Sieveka, E. (1985) · Finite Elements in Analysis and Design · doi:10.1016/0168-874x(85)90020-4 · Cited by 3,781
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Introduction to the Finite Element Method
(2021) · Finite Element Method for Solids and Structures · doi:10.1017/9781108683982.002 · Cited by 2,933
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Computational Methods for Inverse Problems
Vogel, C. R. (2002) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898717570 · Cited by 2,370
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116 · cited 4×
“Like its quasi-static counterpart, harmonic elastography was first proposed as an ultrasound imaging method (Lerner and Parker 1987, Lerner et al 1988, Parker et al 1990, Yamakoshi et al 1990), but was later extended to magnetic resonance imaging (MRI) (Muthupillai et al 1995), and is now the prevailing approach to ma…”
MethodInfluentialShear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
An introduction to the Finite Element Method
van Kan, J. (1992) · Springer eBooks · doi:10.1007/978-94-011-1814-9_2 · Cited by 1,392
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Fundamentals of Physical Acoustics
Blackstock, D. T., & Atchley, A. A. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1354982 · Cited by 761
Samani, A., Zubovits, J., & Plewes, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/6/002 · Cited by 707
Internal displacement and strain imaging using ultrasonic speckle tracking
O'Donnell, M., Skovoroda, A. R., Shapo, B. M., & Emelianov, S. Y. (1994) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.285465 · Cited by 699
Selected Methods for Imaging Elastic Properties of Biological Tissues
Greenleaf, J. F., Fatemi, M., & Insana, M. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121623 · Cited by 671
Ultrasound-Stimulated Vibro-Acoustic Spectrography
Fatemi, M., & Greenleaf, J. F. (1998) · Science · doi:10.1126/science.280.5360.82 · Cited by 642
Comparing Reconstruction Algorithms for Electrical Impedance Tomography
Yorkey, T. J., Webster, J. G., & Tompkins, W. J. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326032 · Cited by 596
Fung, Y. C. (1981) · Springer eBooks · doi:10.1007/978-1-4757-1752-5 · Cited by 580
An Analysis of the Unconfined Compression of Articular Cartilage
Armstrong, C. G., Lai, W. M., & Mow, V. C. (1984) · Journal of Biomechanical Engineering · doi:10.1115/1.3138475 · Cited by 552
Phantom materials for elastography
Hall, T. J., Bilgen, M., Insana, M. F., & Krouskop, T. A. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.656639 · Cited by 516
Viscoelastic shear properties of in vivo breast lesions measured by MR elastography
Sinkus, R., Tanter, M., Xydeas, T., Catheline, S., Bercoff, J., & Fink, M. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.11.060 · Cited by 503
“Sonoelasticity” images derived from ultrasound signals in mechanically vibrated tissues
Lerner, R. M., Huang, S. R., & Parker, K. J. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90002-t · Cited by 493
High-resolution tensor MR elastography for breast tumour detection
Sinkus, R., Lorenzen, J., Schrader, D., Lorenzen, M., Dargatz, M., & Holz, D. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/317 · Cited by 481
Tissue response to mechanical vibrations for “sonoelasticity imaging”
Parker, K. J., Huang, S. R., Musulin, R. A., & Lerner, R. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90003-u · Cited by 478
Imaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
Self-citationUltrasonic imaging of internal vibration of soft tissue under forced vibration
Yamakoshi, Y., Sato, J., & Sato, T. (1990) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.46969 · Cited by 474
EIT reconstruction algorithms: pitfalls, challenges and recent developments
Lionheart, W. R. B. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/1/021 · Cited by 447
A Least-Squares Strain Estimator for Elastography
Kallel, F., & Ophir, J. (1997) · Ultrasonic Imaging · doi:10.1177/016173469701900303 · Cited by 432
The impact of aging and gender on brain viscoelasticity
Sack, I., Beierbach, B., Wuerfel, J., Klatt, D., Hamhaber, U., Papazoglou, S., Martus, P., & Braun, J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.040 · Cited by 423
Catheline, S., Gennisson, J.-L., Delon, G., Fink, M., Sinkus, R., Abouelkaram, S., & Culioli, J. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1815075 · Cited by 409
EIT reconstruction algorithms: pitfalls, challenges and recent developmentsPreprint
Lionheart, W. R. B. (2004) · Cited by 386
Imaging anisotropic and viscous properties of breast tissue by magnetic resonance‐elastography
Sinkus, R., Tanter, M., Catheline, S., Lorenzen, J., Kuhl, C., Sondermann, E., & Fink, M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20355 · Cited by 380
Tissue elasticity reconstruction using linear perturbation method
Kallel, F., & Bertrand, M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.500139 · Cited by 329
Plewes, D. B., Bishop, J., Samani, A., & Sciarretta, J. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/314 · Cited by 318
Magnetic resonance elastography of skeletal muscle
Dresner, M. A., Rose, G. H., Rossman, P. J., Muthupillai, R., Manduca, A., & Ehman, R. L. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200102)13:2<269::aid-jmri1039>3.0.co;2-1 · Cited by 307
Biophysical Bases of Elasticity Imaging
Sarvazyan, A. P., Skovoroda, A. R., Emelianov, S. Y., Fowlkes, J. B., Pipe, J. G., Adler, R. S., Buxton, R. B., & Carson, P. L. (1995) · Acoustical Imaging · doi:10.1007/978-1-4615-1943-0_23 · Cited by 301
Assessment of liver viscoelasticity using multifrequency MR elastography
Asbach, P., Klatt, D., Hamhaber, U., Braun, J., Somasundaram, R., Hamm, B., & Sack, I. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21636 · Cited by 264
Evaluation of an iterative reconstruction method for quantitative elastography
Doyley, M. M., Meaney, P. M., & Bamber, J. C. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/309 · Cited by 251
Self-citationInitial in vivo experience with steady‐state subzone‐based MR elastography of the human breast
Van Houten, E. E. W., Doyley, M. M., Kennedy, F. E., Weaver, J. B., & Paulsen, K. D. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10232 · Cited by 224
Self-citationLerner, R. M., Parker, K. J., Holen, J., Gramiak, R., & Waag, R. C. (1988) · Acoustical Imaging · doi:10.1007/978-1-4613-0725-9_31 · Cited by 220
An overlapping subzone technique for MR-based elastic property reconstruction
Van Houten, E. E. W., Paulsen, K. D., Miga, M. I., Kennedy, F. E., & Weaver, J. B. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199910)42:4<779::aid-mrm21>3.0.co;2-z · Cited by 214
Elastographic characterization of HIFU-induced lesions in canine livers
Righetti, R., Kallel, F., Stafford, R. J., Price, R. E., Krouskop, T. A., Hazle, J. D., & Ophir, J. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00044-7 · Cited by 193
Nonlinear Theory of Elasticity - Applications in Biomechanics
Taber, L. A. (2004) · WORLD SCIENTIFIC eBooks · doi:10.1142/9789812794222 · Cited by 185
Three‐dimensional subzone‐based reconstruction algorithm for MR elastography
Van Houten, E. E. W., Miga, M. I., Weaver, J. B., Kennedy, F. E., & Paulsen, K. D. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1111 · Cited by 179
Local multiscale frequency and bandwidth estimation
Knutsson, H., Westin, C.-F., & Granlund, G. (2002) · Proceedings of 1st International Conference on Image Processing · doi:10.1109/icip.1994.413270 · Cited by 175
de Korte, C. L., Carlier, S. G., Mastik, F., Doyley, M. M., van der Steen, A. F. W., Serruys, P. W., & Bom, N. (2002) · European Heart Journal · doi:10.1053/euhj.2001.2806 · Cited by 175
Self-citationQuantitative elasticity imaging: what can and cannot be inferred from strain images
Barbone, P. E., & Bamber, J. C. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/12/310 · Cited by 171
Ophir, J., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., Righetti, R., & Varghese, T. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00156-3 · Cited by 166
Linear and nonlinear elasticity imaging of soft tissuein vivo: demonstration of feasibility
Oberai, A. A., Gokhale, N. H., Goenezen, S., Barbone, P. E., Hall, T. J., Sommer, A. M., & Jiang, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/006 · Cited by 162
Fundamental mechanical limitations on the visualization of elasticity contrast in elastography
Ponnekanti, H., Ophir, J., Huang, Y., & Céspedes, I. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)00136-2 · Cited by 156
OCT-based elastography for large and small deformations
Kirkpatrick, S. J., Wang, R. K., & Duncan, D. D. (2006) · Optics Express · doi:10.1364/oe.14.011585 · Cited by 153
Fundamental limitations on the contrast-transfer efficiency in elastography: An analytic study
Kallel, F., Bertrand, M., & Ophir, J. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(95)02079-9 · Cited by 153
Elasticity reconstructive imaging by means of stimulated echo MRI
Chenevert, T. L., Skovoroda, A. R., O’Donnell, M., & Emelianov, S. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390319 · Cited by 149
Cédric Schmitt, A., Soulez, G., Maurice, R. L., Giroux, M.-F., & Cloutier, G. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.05.020 · Cited by 146
Poroelastography: imaging the poroelastic properties of tissues
Konofagou, E. E., Harrigan, T. P., Ophir, J., et al. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00433-1 · Cited by 135
The feasibility of using elastography for imaging the Poisson's ratio in porous media
Righetti, R., Ophir, J., Srinivasan, S., et al. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.10.022 · Cited by 126
Optical Coherence Elastography of Engineered and Developing Tissue
Ko, H.-J., Tan, W., Stack, R. A., & Boppart, S. A. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.63 · Cited by 124
Quantitative viscoelastic parameters measured by harmonic motion imaging
Vappou, J., Maleke, C., & Konofagou, E. E. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/11/020 · Cited by 120
In vivo elasticity measurements of extremity skeletal muscle with MR elastography
Uffmann, K., Maderwald, S., Ajaj, W., Galban, C. G., Mateiescu, S., Quick, H. H., & Ladd, M. E. (2004) · NMR in Biomedicine · doi:10.1002/nbm.887 · Cited by 116
Shear modulus reconstruction in dynamic elastography: time harmonic case
Park, E., & Maniatty, A. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/007 · Cited by 114
Magnetic resonance elastography using 3D gradient echo measurements of steady‐state motion
Weaver, J. B., Van Houten, E. E. W., Miga, M. I., Kennedy, F. E., & Paulsen, K. D. (2001) · Medical Physics · doi:10.1118/1.1386776 · Cited by 111
Klatt, D., Friedrich, C., Korth, Y., Vogt, R., Braun, J., & Sack, I. (2010) · Biorheology · doi:10.3233/bir-2010-0565 · Cited by 110
Khalil, A. S., Chan, R. C., Chau, A. H., Bouma, B. E., & Mofrad, M. R. K. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-6766-3 · Cited by 99
Magnetic‐resonance imaging techniques for detection of elasticity variation
Fowlkes, J. B., Emelianov, S., Pipe, J. G., Skovoroda, A. R., Carson, P. L., Adler, R. S., & Sarvazyan, A. P. (1995) · Medical Physics · doi:10.1118/1.597633 · Cited by 97
A new approach to elastography using mutual information and finite elements
Miga, M. I. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/4/304 · Cited by 91
Reconstructive elasticity imaging for large deformations
Skovoroda, A. R., Lubinski, L. A., Emelianov, S., & O’Donnell, M. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.764839 · Cited by 90
Modeling of Soft Poroelastic Tissue in Time-Harmonic MR Elastography
Perriñez, P. R., Kennedy, F. E., Houten, E. E. W. V., Weaver, J. B., & Paulsen, K. D. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2009928 · Cited by 90
Advancing intravascular ultrasonic palpation toward clinical applications
Doyley, M. M., Mastik, F., de Korte, C. L., et al. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00457-4 · Cited by 88
Self-citationAn inverse approach to determining myocardial material properties
Moulton, M. J., Creswell, L. L., Actis, R. L., Myers, K. W., Vannier, M. W., Szabo, B. A., & Pasque, M. K. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00144-s · Cited by 87
Elastographic Imaging of Low-Contrast Elastic Modulus Distributions in Tissue
Kallel, F., Ophir, J., Magee, K., & Krouskop, T. A. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00287-1 · Cited by 87
Quantitative three-dimensional elasticity imaging from quasi-static deformation: a phantom study
Richards, M. S., Barbone, P. E., & Oberai, A. A. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/3/019 · Cited by 85
Wu, Z., Hoyt, K., Rubens, D. J., & Parker, K. J. (2006) · The Journal of the Acoustical Society of America · doi:10.1121/1.2203594 · Cited by 84
Righetti, R., Garra, B. S., Mobbs, L. M., Kraemer-Chant, C. M., Jonathan Ophir, A., & Krouskop, T. A. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/21/013 · Cited by 74
Viscoelasticity imaging using ultrasound: parameters and error analysis
Sridhar, M., Liu, J., & Insana, M. F. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/9/007 · Cited by 74
The nonstationary strain filter in elastography: Part II. Lateral and elevational decorrelation
Kallel, F., Varghese, T., Ophir, J., & Bilgen, M. (1997) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00196-8 · Cited by 73
Vascular wall elasticity measurement by magnetic resonance imaging
Woodrum, D. A., Romano, A. J., Lerman, A., Pandya, U., Brosh, D., Rossman, P. J., Lerman, L. O., & Ehman, R. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20991 · Cited by 73
Souchon, R., Salomir, R., Beuf, O., Milot, L. M., Grenier, D., Lyonnet, D., Chapelon, J., & Rouvière, O. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21718 · Cited by 70
Sack, I., Bernarding, J., & Braun, J. (2002) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(02)00474-5 · Cited by 69
Perriez, P. R., Kennedy, F. E., Houten, E. E. W. V., Weaver, J. B., & Paulsen, K. D. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035309 · Cited by 68
Thresholds for detecting and characterizing focal lesions using steady‐state MR elastography
Doyley, M. M., Weaver, J. B., Houten, E. E. W. V., Kennedy, F. E., & Paulsen, K. D. (2003) · Medical Physics · doi:10.1118/1.1556607 · Cited by 57
Self-citationFreehand Elasticity Imaging Using Speckle Decorrelation Rate
Bamber, J. C., & Bush, N. L. (1996) · Acoustical imaging · doi:10.1007/978-1-4419-8772-3_45 · Cited by 57
Two-dimensional waveform analysis in MR elastography of skeletal muscles
Papazoglou, S., Braun, J., Hamhaber, U., & Sack, I. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/6/018 · Cited by 56
Investigating the impact of spatial priors on the performance of model-based IVUS elastography
Richards, M. S., & Doyley, M. M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/22/014 · Cited by 47
Self-citationIn vivo magnetic resonance elastography of human brain at 7 T and 1.5 T
Hamhaber, U., Klatt, D., Papazoglou, S., Hollmann, M., Stadler, J., Sack, I., Bernarding, J., & Braun, J. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22294 · Cited by 47
Righetti, R., Righetti, M., Ophir, J., & Krouskop, T. A. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/11/020 · Cited by 42
Cédric Schmitt, A., Henni, A. H., & Cloutier, G. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.06.007 · Cited by 40
Evaluation of 3D modality-independent elastography for breast imaging: a simulation study
Ou, J. J., Ong, R. E., Yankeelov, T. E., & Miga, M. I. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/1/010 · Cited by 38
Doyley, M. M., Srinivasan, S., Dimidenko, E., et al. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/1/007 · Cited by 37
Self-citationShear Modulus Estimation Using Parallelized Partial Volumetric Reconstruction
Doyley, M. M., VanHouten, E. E., Weaver, J. B., Poplack, S. P., Duncan, L., Kennedy, F. E., & Paulsen, K. D. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.834624 · Cited by 32
Self-citationElastographie: Quantitative Bildgebung der elastischen Gewebeeigenschaften
Lorenzen, J., Sinkus, R., & Adam, G. (2003) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2003-39199 · Cited by 26
Doyley, M. M., Perreard, I. M., Patterson, A. J., Weaver, J. B., & Paulsen, K. M. (2010) · Medical Physics · doi:10.1118/1.3454738 · Cited by 23
Self-citationPerreard, I. M., Pattison, A. J., Doyley, M. M., McGarry, M., Baráni, Z., Houten, E. E. W. V., Weaver, J. B., & Paulsen, K. D. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/013 · Cited by 21
Self-citationA finite-element mesh generator based on growing neural networks
Triantafyllidis, D. G., & Labridis, D. P. (2002) · IEEE Transactions on Neural Networks · doi:10.1109/tnn.2002.804223 · Cited by 18
Performance analysis of steady-state harmonic elastography
Doyley, M. M., Feng, Q., Weaver, J. B., & Paulsen, K. D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/10/002 · Cited by 12
Self-citationTransient MR Elastography: Modeling Traumatic Brain Injury
McCracken, P. J., Manduca, A., Felmlee, J. P., & Ehman, R. L. (2004) · Lecture notes in computer science · doi:10.1007/978-3-540-30136-3_146 · Cited by 10
Cited by
Bamber, J., Cosgrove, D., Dietrich, C., Fromageau, J., Bojunga, J., Calliada, F., Cantisani, V., Correas, J.-M., D'Onofrio, M., Drakonaki, E., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335205 · Cited by 1,198
Analyses of internal structures and defects in materials using physics-informed neural networks
Zhang, E., Dao, M., Karniadakis, G. E., & Suresh, S. (2022) · Science Advances · doi:10.1126/sciadv.abk0644 · Cited by 393
A Review of Optical Coherence Elastography: Fundamentals, Techniques and Prospects
Kennedy, B. F., Kennedy, K. M., & Sampson, D. D. (2014) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2013.2291445 · Cited by 334
Kennedy, K. M., Chin, L., McLaughlin, R. A., Latham, B., Saunders, C. M., Sampson, D. D., & Kennedy, B. F. (2015) · Scientific Reports · doi:10.1038/srep15538 · Cited by 261
Magnetic resonance elastography from fundamental soft-tissue mechanics to diagnostic imaging
Sack, I. (2022) · Nature Reviews Physics · doi:10.1038/s42254-022-00543-2 · Cited by 162
Metadata
- Authors
- Doyley, M. M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-01-06
- Volume
- 57
- Issue
- 3
- Pages
- R35-R73
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2087944072
- Cited by
- 319
- References
- 99
- FWCI
- 16.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.