The DOI matches its Crossref record; 72 of the 74 references it cites were found in a registry or an index.
Optical properties of biological tissues: a review
Open accessAbstract
A review of reported tissue optical properties summarizes the wavelength-dependent behavior of scattering and absorption. Formulae are presented for generating the optical properties of a generic tissue with variable amounts of absorbing chromophores (blood, water, melanin, fat, yellow pigments) and a variable balance between small-scale scatterers and large-scale scatterers in the ultrastructures of cells and tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“For the scattering, the average number density (a) is 8.54 ± 1.4 and the average effective particle size (b) is 0.75 ± 0.24, for the relationship derived from the Mie model (Jacques 2013).”
From Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle (2018) · cites this paper as Jacques 2013
Experimental — accuracy not yet measuredIn the citing paper
“In particular, obesity can lead to changes in skin thickness, blood flow, and oxygen saturation. This affects the optical properties of skin in addition to the distance light has to travel to reach a target vessel or vessels [48,59,60].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [48]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,479
Optical-Thermal Response of Laser-Irradiated Tissue
Welch, A. J., & van Gemert, M. J. C. (2011) · Springer eBooks · doi:10.1007/978-90-481-8831-4 · Cited by 1,455
PhotochemCAD††: A Computer-Aided Design and Research Tool in Photochemistry
Du, H., Fuh, R.-C. A., Li, J., Corkan, L. A., & Lindsey, J. S. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb02480.x · Cited by 897
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
Bashkatov, A. N., Genina, E. A., & Tuchin, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 765
Optical-Thermal Response of Laser-Irradiated Tissue
Welch, A. J., & van Gemert, M. J. C. (1995) · Springer eBooks · doi:10.1007/978-1-4757-6092-7 · Cited by 705
Simpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
Salomatina, E. V., Jiang, B., Novak, J., & Yaroslavsky, A. N. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2398928 · Cited by 599
The complex refractive index of water
Segelstein, D. J. (1981) · MOspace Institutional Repository (University of Missouri) · Cited by 547
Beekvelt, M. C. P. V., Colier, W. N. J. M., Wevers, R. A., & van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 526
Spectroscopic optical coherence tomography
Morgner, U., Drexler, W., Käertner, F. X., Li, X. D., Pitris, C., Ippen, E. P., & Fujimoto, J. G. (2000) · Optics Letters · doi:10.1364/ol.25.000111 · Cited by 518
Research works printed but not linked: 11
- Anderson R R, 1982, chapter 6, pp 147–94
- Biswas T K, 2011, Internet. J. Radiol., 13, No 1
- Du H, 1998, Photochem. Photobiol., 68, 141
- Jacques S L, 1987, Lasers Life Sci., 1, 309
- Kim A, 2011, Optical-Thermal Response of Laser-Irradiated Tissue
- Ma X, 2005, Opt. Lett., 30
- Newman C, 1991, Lasers Surg. Med., 75
- Prahl S A, 1988, PhD Dissertation
- Solonenko M, 2002, Phys. Med. Biol., 47, 857
- van Veen R L P Sterenborg H J C M Pifferi A Torricelli A Cubeddu R, 2004, OSA Annual BIOMED Topical Meeting
- Zolotarev V M, 1969, Opt. Spectrosc., 27, 430
Cited by
Sorted by citations
Items 701–800 of 1,000
Optoacoustic image formation approaches—a clinical perspective
Deán‐Ben, X. L., & Razansky, D. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab3522 · Cited by 34
Zalev, J., Richards, L. M., Clingman, B. A., Harris, J., Cantu, E., Menezes, G. L. G., Avila, C. A., Bertrand, A., Saenz, X., Miller, S. C., et al. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.12.121915 · Cited by 34
Reconstruction for Fluorescence Molecular Tomography via Adaptive Group Orthogonal Matching Pursuit
Kong, L., An, Y., Liang, Q. Y., Yin, L., Du, Y., & Tian, J. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2963815 · Cited by 34
Geissler, C. F., Schneider, J., & Frings, C. (2021) · Scientific Reports · doi:10.1038/s41598-020-80477-w · Cited by 34
Cancer theranostic platforms based on injectable polymer hydrogels
Wang, F., Chen, J., Liu, J., & Zeng, H. (2021) · Biomaterials Science · doi:10.1039/d0bm02149k · Cited by 34
Paviolo, C., & Cognet, L. (2021) · Neurobiology of Disease · doi:10.1016/j.nbd.2021.105328 · Cited by 35
White, B. E., & Langdon, C. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118324 · Cited by 41
Optical sampling depth in the spatial frequency domain.
Hayakawa, C. K., Karrobi, K., Pera, V., Roblyer, D. M., & Venugopalan, V. (2018) · eScholarship (California Digital Library) · Cited by 34
Bollati, E., Lyndby, N. H., D’Angelo, C., Kühl, M., Wiedenmann, J., & Wangpraseurt, D. (2022) · eLife · doi:10.7554/elife.73521 · Cited by 34
Zhao, Y., Maher, J. R., Kim, J., Selim, M. A., Levinson, H., & Wax, A. P. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003339 · Cited by 34
Lan, Y., & Humayun, M. S. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.8.088001 · Cited by 34
Ma, L., Tan, J., Zhao, J., Wang, F., Wang, C.-A., & Wang, Y. Y. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.03.039 · Cited by 34
Increased light penetration due to ultrasound-induced air bubbles in optical scattering media
Kim, H., & Chang, J. H. (2017) · Scientific Reports · doi:10.1038/s41598-017-16444-9 · Cited by 34
Quantifying Direct DNA Damage in the Basal Layer of Skin Exposed to UV Radiation from Sunbeds
Barnard, I. R. M., Tierney, P., Campbell, C. L., McMillan, L., Moseley, H., Eadie, E., Brown, C. T. A., & Wood, K. (2018) · Photochemistry and Photobiology · doi:10.1111/php.12935 · Cited by 34
Pardo, A., Gutiérrez-Gutiérrez, J. A., Lihacova, I., Higuera, J. M. L., & Conde, O. M. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.006283 · Cited by 34
Functional Photoacoustic and Ultrasonic Assessment of Osteoporosis: A Clinical Feasibility Study
Feng, T., Zhu, Y., Morris, R. F., Kozloff, K. M., & Wang, X. (2020) · BME Frontiers · doi:10.34133/2020/1081540 · Cited by 34
Photobiomodulation in dental extraction therapy
Sourvanos, D., Lander, B., Sarmiento, H., Carroll, J. D., Hall, R. D., Zhu, T. C., & Fiorellini, J. P. (2023) · The Journal of the American Dental Association · doi:10.1016/j.adaj.2023.03.004 · Cited by 33
Photothermal Effects of High-Energy Photobiomodulation Therapies: An In Vitro Investigation
Cronshaw, M., Parker, S. P. A., Grootveld, M. C., & Lynch, E. J. (2023) · Biomedicines · doi:10.3390/biomedicines11061634 · Cited by 33
Goerdt, L., Swain, T. A., Kar, D., McGwin, G., Berlin, A., Clark, M. E., Owsley, C. J., Sloan, K. R., & Curcio, C. A. (2024) · Translational Vision Science & Technology · doi:10.1167/tvst.13.12.19 · Cited by 33
Linero-Artiaga, A., Servos, L.-M., Rodrı́guez, V., Ruiz, J., & Karges, J. (2025) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.5c00431 · Cited by 33
Effects of short-pulsed laser radiation on transient heating of superficial human tissues
Randrianalisoa, J., Dombrovsky, L. A., Lipiński, W., & Timchenko, V. (2014) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2014.07.011 · Cited by 33
Kazakevičiūtė, A., Ho, C. J. H., & Olivo, M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2550624 · Cited by 33
Deán‐Ben, X. L., Stiel, A. C., Jiang, Y., Ntziachristos, V., Westmeyer, G. G., & Razansky, D. (2015) · Optics Letters · doi:10.1364/ol.40.004691 · Cited by 33
Li, W., Du, T., Lan, J., Guo, C., Cheng, Y., Xu, H., Zhu, C., Wang, F., Luo, Z., & Caï, Z. (2017) · Optics Letters · doi:10.1364/ol.42.000671 · Cited by 33
Angiographic and structural imaging using high axial resolution fiber-based visible-light OCT
Pi, S., Camino, A., Zhang, M., Cepurna, W. O., Liu, G., Huang, D., Morrison, J., & Jia, Y. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.004595 · Cited by 33
Bondu, M., Marques, M. J. M., Moselund, P. M., Lall, G. S., Bradu, A., & Podoleanu, A. G. (2017) · Photoacoustics · doi:10.1016/j.pacs.2017.11.002 · Cited by 33
Rapid Aqueous Photouncaging by Red Light
Wang, X., & Kalow, J. A. (2018) · Organic Letters · doi:10.1021/acs.orglett.8b00100 · Cited by 33
Zhang, S., Ma, X., Wang, Y., Wu, M., Meng, H., Chai, W., Wang, X., Wei, S., & Tian, J. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2825102 · Cited by 33
Evaluating the effects of causes of death on postmortem interval estimation by ATR-FTIR spectroscopy
Zhang, K., Wang, Q., Liu, R., Wei, X., Li, Z., Fan, S., & Wang, Z. (2019) · International Journal of Legal Medicine · doi:10.1007/s00414-019-02042-z · Cited by 33
Kato, N. (2019) · Biophysical Reviews · doi:10.1007/s12551-019-00546-x · Cited by 33
Polarized Light-Based Cancer Cell Detection Techniques: A Review
Tukimin, S. N., Karman, S. B., Ahmad, M. Y., & Zaman, W. S. W. K. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2924535 · Cited by 33
Feng, T., Ge, Y., Xie, Y., Xie, W., Liu, C., Li, L., Ta, D., Jiang, Q. Y., & Cheng, Q. (2021) · Photoacoustics · doi:10.1016/j.pacs.2021.100296 · Cited by 33
Bergmann, F., Foschum, F., Marzel, L., & Kienle, A. (2021) · Photonics · doi:10.3390/photonics8090365 · Cited by 33
Polydimethylsiloxane tissue-mimicking phantoms with tunable optical properties
Goldfain, A. M., Lemaillet, P., Allen, D. W., Briggman, K. A., & Hwang, J. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.7.074706 · Cited by 33
Photodynamic treatment of pathogens
Delcanale, P., Abbruzzetti, S., & Viappiani, C. (2022) · Rivista Del Nuovo Cimento · doi:10.1007/s40766-022-00031-4 · Cited by 34
Zhao, M., Zhou, W., Aparanji, S., Mazumder, D., & Srinivasan, V. J. (2022) · Optica · doi:10.1364/optica.472471 · Cited by 33
Tong, S., Zhong, J., Chen, X., Deng, X., Huang, J., Zhang, Y., Qin, M., Li, Z., Cheng, H., Zhang, W., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c10724 · Cited by 33
Maher, J. R., Chuchuen, O., Henderson, M. H., Kim, S., Rinehart, M. T., Kashuba, A. D. M., Wax, A. P., & Katz, D. F. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.002022 · Cited by 32
Simultaneous photoacoustic and optically mediated ultrasound microscopy: an in vivo study
Subochev, P., Orlova, A., Shirmanova, M. V., Postnikova, A. S., & Turchin, I. V. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.000631 · Cited by 32
Wu, T.-H., Chang, C., Vaillant, J., Bruyant, A., & Lin, C. (2016) · Lab on a Chip · doi:10.1039/c6lc01170e · Cited by 32
Intraoperative molecular imaging to identify lung adenocarcinomas
Newton, A. D., Kennedy, G. T., Predina, J. D., Low, P. S., & Singhal, S. K. (2016) · Journal of Thoracic Disease · doi:10.21037/jtd.2016.09.50 · Cited by 32
Photoacoustic imaging features of intraocular tumors: Retinoblastoma and uveal melanoma
Xu, G., Xue, Y., Özkurt, Z., Slimani, N., Hu, Z., Wang, X., Xia, K., Ma, T., Zhou, Q., & Demirci, H. (2017) · PLoS ONE · doi:10.1371/journal.pone.0170752 · Cited by 32
Biobeam—Multiplexed wave-optical simulations of light-sheet microscopy
WEIGERT, M. G., Subramanian, K., Bundschuh, S. T., Myers, E. W., & Kreysing, M. (2018) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1006079 · Cited by 32
He, X., Jiang, X., Fu, X., Gao, Y., & Rao, X. (2018) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2018.05.018 · Cited by 32
Wangpraseurt, D., Jacques, S. L., Lyndby, N. H., Holm, J. B., Ferrier‐Pagès, C., & Kühl, M. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2018.0567 · Cited by 32
Effects of maternal anxiety and depression on fetal neuro-development
Reissland, N., Froggatt, S., Reames, E., & Girkin, J. M. (2018) · Journal of Affective Disorders · doi:10.1016/j.jad.2018.08.047 · Cited by 36
Rowland, R. A., Ponticorvo, A., Lopez, A. J., Li, S., Li, X., Ichii, H., & Durkin, A. J. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.116003 · Cited by 32
Feng, Y., Chen, H., Wu, Y., Que, I., Tamburini, F., Baldazzi, F., Chang, Y., & Zhang, H. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119637 · Cited by 32
Borovkova, M. A., Bykov, A. V., Popov, A., & Meglinski, I. V. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.5.057001 · Cited by 32
Challenges in Scaling Down of Free-Floating Implantable Neural Interfaces to Millimeter Scale
Yang, K.-W. K., Oh, K., & Ha, S. (2020) · IEEE Access · doi:10.1109/access.2020.3007517 · Cited by 32
Huet, A. T., Dombrowski, T., Rankovic, V., Thirumalai, A., & Moser, T. (2021) · Frontiers in Molecular Neuroscience · doi:10.3389/fnmol.2021.635897 · Cited by 34
Lopes, J., Ferreira-Gonçalves, T., Figueiredo, I. V., Rodrigues, C. M. P., Ferreira, H. A., Ferreira, D., Viana, A. S., Faísca, P., Gaspar, M. M., Coelho, J. M. P., et al. (2021) · Biomolecules · doi:10.3390/biom11040511 · Cited by 32
Taal, A. J., Lee, C., Choi, J., Hellenkamp, B., & Shepard, K. L. (2022) · Light Science & Applications · doi:10.1038/s41377-022-00708-9 · Cited by 32
Photodynamic Therapeutic Effect of Nanostructured Metal Sulfide Photosensitizers on Cancer Treatment
Diaz-Diestra, D., Gholipour, H. M., Bazian, M., Thapa, B., & Beltran-Huarac, J. (2022) · Nanoscale Research Letters · doi:10.1186/s11671-022-03674-8 · Cited by 23
Observation and motor imagery balance tasks evaluation: An fNIRS feasibility study
Almulla, L., Al-Naib, I. A. I., Ateeq, I. S., & Althobaiti, M. (2022) · PLoS ONE · doi:10.1371/journal.pone.0265898 · Cited by 32
Li, Z., Baker, W. B., Parthasarathy, A. B., Ko, T. S., Wang, D., Schenkel, S. S., Durduran, T., Li, G., & Yodh, A. G. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.12.125005 · Cited by 33
The action spectrum for vitamin D3: initial skin reaction and prolonged exposure
van Dijk, A., den Outer, P. N., van Kranen, H. J., & Slaper, H. (2016) · Photochemical & Photobiological Sciences · doi:10.1039/c6pp00034g · Cited by 32
Spectral contrast optical coherence tomography angiography enables single-scan vessel imaging
Winkelmann, J. A., Eid, A., Spicer, G. L. C., Almassalha, L. M., Nguyen, T., & Backman, V. (2019) · Light Science & Applications · doi:10.1038/s41377-018-0117-7 · Cited by 32
Grancharova, T., Zagorchev, P. I., & Pilicheva, B. (2024) · Journal of Functional Biomaterials · doi:10.3390/jfb15080207 · Cited by 31
Use of optical skin phantoms for preclinical evaluation of laser efficiency for skin lesion therapy
Wróbel, M. S., Szczerska, M., GALLA, S., Piechowski, L., Sawczak, M., Popov, A., Bykov, A. V., Tuchin, V. V., & Cenian, A. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.8.085003 · Cited by 31
Diop, M., Wright, E. A., Toronov, V. Y., Lee, T.-Y., & Lawrence, K. S. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.5.057007 · Cited by 31
Bodenschatz, N., Krauter, P., Liemert, A., Wiest, J., & Kienle, A. (2015) · Applied Optics · doi:10.1364/ao.54.006725 · Cited by 31
Pagano, R., Libertino, S., Sanfilippo, D., Fallica, G., & Lombardo, S. A. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.001183 · Cited by 31
Diffuse Reflectance Spectroscopy for Surface Measurement of Liver Pathology
Nilsson, J. H., Reistad, N., Brange, H., Öberg, C.-F., & Sturesson, C. (2016) · European Surgical Research · doi:10.1159/000449378 · Cited by 31
Forti, R. M. M., Favilla, C. G., Cochran, J. M., Baker, W. B., Detre, J. A., Kasner, S. E., Mullen, M. T., Messe, S. R., Kofke, W. A., Balu, R., et al. (2019) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2019.03.019 · Cited by 31
Glaser, A. K., Chen, Y., Yin, C., Wei, L., Barner, L. A. E., Reder, N. P., & Liu, J. T. C. (2018) · Scientific Reports · doi:10.1038/s41598-018-32367-5 · Cited by 31
Inyushin, M. Y., Мешалкина, Д. А., Zueva, L. V., & Zayas‐Santiago, A. (2019) · Molecules · doi:10.3390/molecules24132388 · Cited by 33
Applications of the femtosecond laser-induced impulse to cell research
Hosokawa, Y. (2019) · Japanese Journal of Applied Physics · doi:10.7567/1347-4065/ab4749 · Cited by 31
Pominova, D. V., Proydakova, V. Y., Romanishkin, I. D., Ryabova, A. V., Кузнецов, С. В., Уваров, О. В., Федоров, П. П., & Loschenov, V. B. (2020) · Nanomaterials · doi:10.3390/nano10101992 · Cited by 32
Aref, M. H., Sharawi, A. A., & El-Sharkawy, Y. H. (2021) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2021.102190 · Cited by 31
A brief review of reporter gene imaging in oncolytic virotherapy and gene therapy
Concilio, S. C., Russell, S. J., & Peng, K.-W. (2021) · Molecular Therapy — Oncolytics · doi:10.1016/j.omto.2021.03.006 · Cited by 30
Chenot, Q., Lepron, E., Boissezon, X. D., & Scannella, S. (2021) · Frontiers in Neuroergonomics · doi:10.3389/fnrgo.2021.718176 · Cited by 38
Skin optical properties in the obese and their relation to body mass index: a review
Rodriguez, A. J., Boonya-Ananta, M. T., Gonzalez, M., Le, V. N. D., Fine, J. N., Palacios, C. S., McShane, M. J., Coté, G. L., & Ramella‐Roman, J. C. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.3.030902 · Cited by 34
Wu, Y., Xu, Z., Yang, W., Ning, Z., & Dong, H. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.906728 · Cited by 31
A Review of Image Reconstruction Algorithms for Diffuse Optical Tomography
Okawa, S., & Hoshi, Y. (2023) · Applied Sciences · doi:10.3390/app13085016 · Cited by 31
Wu, Z., Deng, B., Zhou, Y., Xie, H., Zhang, Y., Lin, L., & Ye, J. (2023) · Advanced Science · doi:10.1002/advs.202301721 · Cited by 30
Effects of skin tone on photoacoustic imaging and oximetry
Else, T. R., Hacker, L., Gröhl, J., Bunce, E. V., Tao, R., & Bohndiek, S. E. (2023) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.s1.s11506 · Cited by 32
van Vliet‐Pérez, S. M., van de Berg, N. J., Manni, F., Lai, M., Rijstenberg, L. L., Hendriks, B. H. W., Dankelman, J., Ewing‐Graham, P. C., Boer, G. M. N.-D., & van Beekhuizen, H. J. (2022) · Cancers · doi:10.3390/cancers14061422 · Cited by 30
Rare earth-doped nanocrystals for bioimaging in the near-infrared region
Meng, J., Cui, Y., & Wang, Y. (2022) · Journal of Materials Chemistry B · doi:10.1039/d2tb01731h · Cited by 30
Kaub, L., & Schmitz, C. (2022) · Biomedicines · doi:10.3390/biomedicines10123204 · Cited by 30
Zhu, J., Huynh, N. T., Ogunlade, O. O., Ansari, R., Lucka, F. F., Cox, B., & Beard, P. C. (2023) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2023.3271390 · Cited by 30
Full-view LED-based optoacoustic tomography
Liu, X., Kalva, S. K., Lafci, B., Nozdriukhin, D. V., Deán‐Ben, X. L., & Razansky, D. (2023) · Photoacoustics · doi:10.1016/j.pacs.2023.100521 · Cited by 30
Hirshfield, L., Wickens, C. D., Doherty, E. J., Spencer, C. A., Williams, T., & Hayne, L. (2023) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2023.2266242 · Cited by 31
An autonomous implantable device for the prevention of death from opioid overdose
Ciatti, J. L., Vázquez‐Guardado, A., Brings, V. E., Park, J., Ruyle, B. C., Ober, R. A., McLuckie, A. J., Talcott, M., Carter, E. A., Burrell, A. R., et al. (2024) · Science Advances · doi:10.1126/sciadv.adr3567 · Cited by 30
Characterisation of a fibre optic Raman probe within a hypodermic needle
Petterson, I. E. I., Day, J. C. C., Fullwood, L. M., Gardner, B., & Stone, N. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-9021-7 · Cited by 30
Time-resolved subtraction method for measuring optical properties of turbid media
Milej, D. F., Abdalmalak, A., Janusek, D., Diop, M., Liebert, A., & Lawrence, K. S. (2016) · Applied Optics · doi:10.1364/ao.55.001507 · Cited by 30
Wilson, R. H., Vishwanath, K., & Mycek, M. (2016) · Advances in Physics X · doi:10.1080/23746149.2016.1221739 · Cited by 30
Comparative Design Study for Power Reduction in Organic Optoelectronic Pulse Meter Sensor
Elsamnah, F., Bilgaiyan, A., Misran, M. A. B., Shim, C.-H., Ishidai, H., & Hattori, R. (2019) · Biosensors · doi:10.3390/bios9020048 · Cited by 30
Designing visible-light optical coherence tomography towards clinics
Shu, X., Beckmann, L., Wang, Y., Rubinoff, I., Lucy, K. A., Ishikawa, H., Wollstein, G., Fawzi, A. A., Schuman, J. S., Kuranov, R. V., et al. (2019) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2019.05.01 · Cited by 30
Intraoperative quantitative functional brain mapping using an RGB camera
Caredda, C., Mahieu-Williame, L., Sablong, R., Sdika, M., Alston, L., Guyotat, J., & Montcel, B. (2019) · Neurophotonics · doi:10.1117/1.nph.6.4.045015 · Cited by 30
Throughput-Speed Product Augmentation for Scanning Fiber-Optic Two-Photon Endomicroscopy
Liang, W., Park, H., Li, K., Li, A., Chen, D., Guan, H., Yue, Y., Gau, Y. A., Bergles, D. E., Li, M.-J., et al. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3005067 · Cited by 30
Pal, U. M., Vishnu, G. K. A., Gogoi, G., Rila, S., Shroff, S., Gokul, A. M., Borah, P., Varma, M. M., Kurpad, V., Baruah, D. K., et al. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3005971 · Cited by 30
Tang, Y., & Yao, J. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-20-815 · Cited by 30
Beyond backscattering: optical neuroimaging by BRAD.
Eugui, P., Lichtenegger, A., Augustin, M., Harper, D. J., Muck, M., Roetzer-Pejrimovsky, T., Wartak, A., Konegger, T., Widhalm, G., Hitzenberger, C. K. F., et al. (2018) · Apollo (University of Cambridge) · Cited by 30
Single-sweep volumetric optoacoustic tomography of whole mice
Kalva, S. K., Deán‐Ben, X. L., & Razansky, D. (2021) · Photonics Research · doi:10.1364/prj.418591 · Cited by 30
Hacker, L., Joseph, J. A., Ivory, A. M., Saed, M. O., Zeqiri, B., Rajagopal, S., & Bohndiek, S. E. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3090857 · Cited by 30
Matchynski, J. I., Manwar, R., Kratkiewicz, K., Madangopal, R., Lennon, V. A., Makki, K., Reppen, A., Woznicki, A. R., Hope, B. T., Perrine, S. A., et al. (2021) · Photoacoustics · doi:10.1016/j.pacs.2021.100297 · Cited by 30
Ferreira-Gonçalves, T., Gaspar, M. M., Coelho, J. M. P., Marques, V., Viana, A. S., Ascensão, L., Carvalho, L., Rodrigues, C. M. P., Ferreira, H. A., Ferreira, D., et al. (2022) · Biomolecules · doi:10.3390/biom12010071 · Cited by 30
Dombrovsky, L. A. (2022) · Frontiers in Thermal Engineering · doi:10.3389/fther.2021.807083 · Cited by 30
A guideline for clinicians performing clinical studies with fluorescence imaging
Heeman, W. T., Vonk, J., Ntziachristos, V., Pogue, B. W., Dierckx, R. A. J. O., Kruijff, S., & van Dam, G. M. (2022) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.262975 · Cited by 30
Metadata
- Authors
- Jacques, S. L.
- Affiliations
- Oregon Health & Science University (US)
- Corresponding author
- Jacques, Steven L
- ORCID
- Jacques, Steven L
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2013-05-10
- Volume
- 58
- Issue
- 11
- Pages
- R37-R61
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2097683070
- Cited by
- 4,008
- References
- 74
- Citations by year
- 2026: 350 · 2025: 346 · 2024: 313 · 2023: 332 · 2022: 323 · 2021: 362 · 2020: 363 · 2019: 383 · 2018: 320 · 2017: 299 · 2016: 272 · 2015: 217 · 2014: 107 · 2013: 15
- FWCI
- 28.94
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
- Keywords
- tissue optical properties, light scattering, optical absorption, chromophores, blood, melanin, fats, wavelength dependence, cell ultrastructure
- MeSH terms
- Animals, Biology, Humans, Anisotropy, Optical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review