The DOI matches its Crossref record; 72 of the 74 references it cites were found in a registry or an index.
Optical properties of biological tissues: a review
Open accessAbstract
A review of reported tissue optical properties summarizes the wavelength-dependent behavior of scattering and absorption. Formulae are presented for generating the optical properties of a generic tissue with variable amounts of absorbing chromophores (blood, water, melanin, fat, yellow pigments) and a variable balance between small-scale scatterers and large-scale scatterers in the ultrastructures of cells and tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“For the scattering, the average number density (a) is 8.54 ± 1.4 and the average effective particle size (b) is 0.75 ± 0.24, for the relationship derived from the Mie model (Jacques 2013).”
From Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle (2018) · cites this paper as Jacques 2013
Experimental — accuracy not yet measuredIn the citing paper
“In particular, obesity can lead to changes in skin thickness, blood flow, and oxygen saturation. This affects the optical properties of skin in addition to the distance light has to travel to reach a target vessel or vessels [48,59,60].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [48]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,479
Optical-Thermal Response of Laser-Irradiated Tissue
Welch, A. J., & van Gemert, M. J. C. (2011) · Springer eBooks · doi:10.1007/978-90-481-8831-4 · Cited by 1,455
PhotochemCAD††: A Computer-Aided Design and Research Tool in Photochemistry
Du, H., Fuh, R.-C. A., Li, J., Corkan, L. A., & Lindsey, J. S. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb02480.x · Cited by 897
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
Bashkatov, A. N., Genina, E. A., & Tuchin, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 765
Optical-Thermal Response of Laser-Irradiated Tissue
Welch, A. J., & van Gemert, M. J. C. (1995) · Springer eBooks · doi:10.1007/978-1-4757-6092-7 · Cited by 705
Simpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
Salomatina, E. V., Jiang, B., Novak, J., & Yaroslavsky, A. N. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2398928 · Cited by 599
The complex refractive index of water
Segelstein, D. J. (1981) · MOspace Institutional Repository (University of Missouri) · Cited by 547
Beekvelt, M. C. P. V., Colier, W. N. J. M., Wevers, R. A., & van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 526
Spectroscopic optical coherence tomography
Morgner, U., Drexler, W., Käertner, F. X., Li, X. D., Pitris, C., Ippen, E. P., & Fujimoto, J. G. (2000) · Optics Letters · doi:10.1364/ol.25.000111 · Cited by 518
Research works printed but not linked: 11
- Anderson R R, 1982, chapter 6, pp 147–94
- Biswas T K, 2011, Internet. J. Radiol., 13, No 1
- Du H, 1998, Photochem. Photobiol., 68, 141
- Jacques S L, 1987, Lasers Life Sci., 1, 309
- Kim A, 2011, Optical-Thermal Response of Laser-Irradiated Tissue
- Ma X, 2005, Opt. Lett., 30
- Newman C, 1991, Lasers Surg. Med., 75
- Prahl S A, 1988, PhD Dissertation
- Solonenko M, 2002, Phys. Med. Biol., 47, 857
- van Veen R L P Sterenborg H J C M Pifferi A Torricelli A Cubeddu R, 2004, OSA Annual BIOMED Topical Meeting
- Zolotarev V M, 1969, Opt. Spectrosc., 27, 430
Cited by
Sorted by citations
Items 401–500 of 1,000
Nanostructured Organic/Hybrid Materials and Components in Miniaturized Optical and Chemical Sensors
Prosa, M., Bolognesi, M., Fornasari, L., Grasso, G., Lopez‐Sanchez, L., Marabelli, F., & Toffanin, S. (2020) · Nanomaterials · doi:10.3390/nano10030480 · Cited by 61
A wavelength-induced frequency filtering method for fluorescent nanosensors in vivo
Koman, V. B., Bakh, N. A., Jin, X., Nguyen, F. T., Son, M., Kozawa, D., Lee, M. A., Bisker, G., Dong, J. I., & Strano, M. S. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01136-x · Cited by 57
Noninvasive hemoglobin sensing and imaging: optical tools for disease diagnosis
Taylor-Williams, M., Spicer, G. L. C., Bale, G. M., & Bohndiek, S. E. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.8.080901 · Cited by 65
Zhang, Q., Wang, F., Wang, R., Liu, J., Ma, Y., Qin, X., & Zhong, X. (2023) · Advanced Science · doi:10.1002/advs.202207566 · Cited by 58
Phase preservation of orbital angular momentum of light in multiple scattering environment
Meglinski, I. V., Lopushenko, I. V., Sdobnov, A. Y., & Bykov, A. V. (2024) · Light Science & Applications · doi:10.1038/s41377-024-01562-7 · Cited by 63
Optical imaging probes in oncology
Martelli, C., Dico, A. L., Diceglie, C., Lucignani, G., & Ottobrini, L. (2016) · Oncotarget · doi:10.18632/oncotarget.9066 · Cited by 58
3D reconstruction of cystoscopy videos for comprehensive bladder records
Lurie, K. L., Angst, R., Zlatev, D. V., Liao, J. C., & Bowden, A. K. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.002106 · Cited by 58
Optical properties of animal tissues in the wavelength range from 350 to 2600 nm
Filatova, S. A., Shcherbakov, I. A., & Цветков, В. Б. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.3.035009 · Cited by 58
Unbiased estimation of an optical loss at the ultimate quantum limit with twin-beams
Losero, E., Berchera, I. R., Meda, A., Avella, A., & Genovese, M. (2018) · Scientific Reports · doi:10.1038/s41598-018-25501-w · Cited by 58
Wide-field multiphoton imaging through scattering media without correction
Escobet-Montalbán, A., Spesyvtsev, R., Chen, M., Saber, W. A., Andrews, M. R., Herrington, C. S., Mazilu, M., & Dholakia, K. (2018) · Science Advances · doi:10.1126/sciadv.aau1338 · Cited by 58
Which wavelength is optimal for transcranial low‐level laser stimulation?
Wang, P., & Li, T. (2018) · Journal of Biophotonics · doi:10.1002/jbio.201800173 · Cited by 58
Systematic Review of Orthodontic Treatment Management with Photobiomodulation Therapy
Cronshaw, M., Parker, S. P. A., Anagnostaki, E., & Lynch, E. J. (2019) · Photobiomodulation Photomedicine and Laser Surgery · doi:10.1089/photob.2019.4702 · Cited by 58
Hyperspectral imaging and robust statistics in non-melanoma skin cancer analysis
Courtenay, L. A., González‐Aguilera, D., Lagüela, S., Pozo, S. D., Ruíz, C., Barbero-García, I., Román‐Curto, C., Cañueto, J., Santos-Durán, C., Cardeñoso-Álvarez, M. E., et al. (2021) · Biomedical Optics Express · doi:10.1364/boe.428143 · Cited by 57
Three-dimensional printed optical phantoms with customized absorption and scattering properties
Diep, P., Pannem, S., Sweer, J., Lo, J., Snyder, M., Stueber, G., Zhao, Y., Tabassum, S. M., Istfan, R., Wu, J., et al. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.004212 · Cited by 59
Bhattacharya, M., & Dutta, A. (2019) · Brain Sciences · doi:10.3390/brainsci9080179 · Cited by 57
Context encoding enables machine learning-based quantitative photoacoustics
Kirchner, T., Gröhl, J., & Maier‐Hein, L. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.5.056008 · Cited by 63
Chowdhury, K. B., Prakash, J., Karlas, A., Jüstel, D., & Ntziachristos, V. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2989236 · Cited by 57
Asadi, S., Bianchi, L., Landro, M. D., Korganbayev, S., Schena, E., & Saccomandi, P. (2020) · Journal of Biophotonics · doi:10.1002/jbio.202000161 · Cited by 57
Shin, S., Lee, Y., Kim, S.-C., Choi, S., Kim, J. G., & Lee, K. (2021) · Food Chemistry · doi:10.1016/j.foodchem.2021.129329 · Cited by 56
Studier‐Fischer, A., Seidlitz, S., Sellner, J., Özdemir, B., Wiesenfarth, M., Ayala, L. A., Odenthal, J., Knödler, S., Kowalewski, K., Haney, C. M., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-15040-w · Cited by 56
Gremse, F., Theek, B., Kunjachan, S., Lederle, W., Pardo, A., Barth, S., Lammers, T., Naumann, U., & Kiessling, F. M. (2014) · Theranostics · doi:10.7150/thno.9293 · Cited by 56
Berke, I. M., Miola, J. P., David, M. A., Smith, M. K., & Price, C. (2016) · PLoS ONE · doi:10.1371/journal.pone.0150268 · Cited by 53
Fractal propagation method enables realistic optical microscopy simulations in biological tissues
Glaser, A. K., Chen, Y., & Liu, J. T. C. (2016) · Optica · doi:10.1364/optica.3.000861 · Cited by 56
Splanchnic NIRS monitoring in neonatal care: rationale, current applications and future perspectives
Martini, S., & Corvaglia, L. (2018) · Journal of Perinatology · doi:10.1038/s41372-018-0075-1 · Cited by 56
Cortese, L., Presti, G. L., Pagliazzi, M., Contini, D., Mora, A. D. D., Pifferi, A., Sekar, S. K. V., Spinelli, L., Taroni, P., Zanoletti, M., et al. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.002068 · Cited by 56
Dual-display laparoscopic laser speckle contrast imaging for real-time surgical assistance
Zheng, C., Lau, L. W., & Cha, J. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.005962 · Cited by 56
Mosca, S., Lanka, P., Stone, N., Sekar, S. K. V., Matousek, P., Valentini, G., & Pifferi, A. (2020) · Biomedical Optics Express · doi:10.1364/boe.386349 · Cited by 56
Near-infrared spatiotemporal color vision in humans enabled by upconversion contact lenses
Ma, Y., Chen, Y., Wang, S., Chen, Z., Zhang, Y., Huang, L. F., Zhang, X., Yin, F., Wang, Y., Yang, M., et al. (2025) · Cell · doi:10.1016/j.cell.2025.04.019 · Cited by 55
Photoacoustic imaging of human lymph nodes with endogenous lipid and hemoglobin contrast
Guggenheim, J. A., Allen, T. J., Plumb, A., Zhang, E., Rodriguez‐Justo, M., Punwani, S., & Beard, P. C. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.5.050504 · Cited by 55
Diop, M., Kishimoto, J., Toronov, V. Y., Lee, D. S. C., & Lawrence, K. S. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003907 · Cited by 55
Quantifying the influence of Bessel beams on image quality in optical coherence tomography
Curatolo, A., Munro, P. R. T., Lorenser, D., Sreekumar, P., Singe, C. C., Kennedy, B. F., & Sampson, D. D. (2016) · Scientific Reports · doi:10.1038/srep23483 · Cited by 55
Graphene Meets Microbubbles: A Superior Contrast Agent for Photoacoustic Imaging
Toumia, Y., Domenici, F., Orlanducci, S., Mura, F., Grishenkov, D., Trochet, P., Lacerenza, S., Bordi, F., & Paradossi, G. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b04184 · Cited by 55
Generalized Beer–Lambert model for near-infrared light propagation in thick biological tissues
Bhatt, M., Ayyalasomayajula, K. R., & Yalavarthy, P. K. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.076012 · Cited by 55
Gandioso, A., Cano, M., Massaguer, A., & Marchán, V. (2016) · The Journal of Organic Chemistry · doi:10.1021/acs.joc.6b02415 · Cited by 55
Multiple scattering limit in optical microscopy
Badon, A., Boccara, C., Lerosey, G., Fink, M., & Aubry, A. (2017) · Optics Express · doi:10.1364/oe.25.028914 · Cited by 55
Improving the Flow Cytometry-based Detection of the Cellular Uptake of Gold Nanoparticles
Wu, Y., Ali, M. R. K., Dansby, K., & El‐Sayed, M. A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b02248 · Cited by 55
Bonilauri, A., Intra, F. S., Pugnetti, L., Baselli, G., & Baglio, F. (2020) · Diagnostics · doi:10.3390/diagnostics10080581 · Cited by 55
Bioluminescence Tomography–Guided Radiation Therapy for Preclinical Research
Zhang, B., Wang, K. K., Yu, J., Eslami, S., Iordachita, I. I., Reyes, J., Malek, R. A., Tran, P. T., Patterson, M. S., & Wong, J. W. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.11.039 · Cited by 54
Visual Quality Enhancement in Optoacoustic Tomography Using Active Contour Segmentation Priors
Mandal, S., Deán‐Ben, X. L., & Razansky, D. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2553156 · Cited by 51
Optical Guidance Systems for Epidural Space Identification
Carotenuto, B., Micco, A., Ricciardi, A., Amorizzo, E., Mercieri, M., Cutolo, A., & Cusano, A. (2016) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2016.2600027 · Cited by 54
Wang, H., Magnain, C. V., Sakadžić, S., Fischl, B. R., & Boas, D. A. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.005617 · Cited by 58
Bierman, A., LaPlumm, T., Cadle-Davidson, L. E., Gadoury, D. M., Martínez, D., Sapkota, S., & Rea, M. S. (2019) · Plant Phenomics · doi:10.34133/2019/9209727 · Cited by 54
Hamann, A., & Carstengerdes, N. (2022) · Scientific Reports · doi:10.1038/s41598-022-10044-y · Cited by 64
Polarised stereo endoscope and narrowband detection for minimal access surgery
Clancy, N. T., Arya, S., Qi, J., Stoyanov, D. V., Hanna, G. B., & Elson, D. S. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004108 · Cited by 53
Plasmonic Surfaces for Cell Growth and Retrieval Triggered by Near‐Infrared Light
Giner-Casares, J. J., Henriksen‐Lacey, M., Garcı́a, I., & Liz‐Marzán, L. M. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201509025 · Cited by 53
Human skin detection in the visible and near infrared
Mendenhall, M. J., Nunez, A. S., & Martin, R. K. (2015) · Applied Optics · doi:10.1364/ao.54.010559 · Cited by 53
Lei, H. C., Johnson, L. A., Liu, S., Moons, D. S., Ma, T., Zhou, Q., Rice, M. D., Ni, J., Wang, X., Higgins, P., et al. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.002837 · Cited by 53
Schwarz, M., Soliman, D., Omar, M., Buehler, A., Ovsepian, S. V., Aguirre, J., & Ntziachristos, V. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2664142 · Cited by 53
In vivo imaging of coral tissue and skeleton with optical coherence tomography
Wangpraseurt, D., Wentzel, C., Jacques, S. L., Wagner, M., & Kühl, M. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2016.1003 · Cited by 54
Zhang, X., Guo, Z. J., Liu, J., Tian, G., Chen, K., Yu, S., & Gu, Z. (2017) · 中国科学通报:英文版 · doi:10.1016/j.scib.2017.06.010 · Cited by 53
The Depolarization Performances of the Polarized Light in Different Scattering Media Systems
Shen, F., Zhang, B., Guo, K., Yin, Z., & Guo, Z. (2017) · IEEE photonics journal · doi:10.1109/jphot.2017.2773476 · Cited by 53
Intraoperative hyperspectral determination of human tissue properties
Wisotzky, E. L., Uecker, F. C., Arens, P., Dommerich, S., Hilsmann, A., & Eisert, P. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.9.091409 · Cited by 53
Optical Wireless Power Transmission Using Si Photovoltaic Through Air, Water, and Skin
Putra, A. W. S., Tanizawa, M., & Maruyama, T. (2018) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2018.2887081 · Cited by 53
Organic Photovoltaic Pseudocapacitors for Neurostimulation
Han, M., Srivastava, S. B., Yıldız, E., Melikov, R., Sürme, S., Dogru-Yuksel, I. B., Kavaklı, İ. H., Şahin, A., & Nizamoğlu, S. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c11581 · Cited by 55
Optical manipulation: advances for biophotonics in the 21st century
Corsetti, S., & Dholakia, K. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.26.7.070602 · Cited by 53
Intraoperative Tumor Detection Using Pafolacianine
Dindere, M. E., Tanca, A., Rusu, M., Liehn, E. A., & Bucur, O. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms232112842 · Cited by 52
Kaub, L., & Schmitz, C. (2023) · Biomedicines · doi:10.3390/biomedicines11051355 · Cited by 52
Quantitative photoacoustic tomography: modeling and inverse problems
Tarvainen, T., & Cox, B. (2023) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.s1.s11509 · Cited by 52
Gong, P., Es’haghian, S., Harms, K., Murray, A., Rea, S. M., Kennedy, B. F., Wood, F. M., Sampson, D. D., & McLaughlin, R. A. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201500157 · Cited by 52
Enhanced contrast and depth resolution in polarization imaging using elliptically polarized light
Sridhar, S., & Silva, A. D. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071107 · Cited by 52
Wirkert, S., Kenngott, H., Mayer, B. F. B., Mietkowski, P., Wagner, M., Sauer, P., Clancy, N. T., Elson, D. S., & Maier‐Hein, L. (2016) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-016-1376-5 · Cited by 52
High resolution Physio-chemical Tissue Analysis: Towards Non-invasive In Vivo Biopsy
Xu, G., Meng, Z., Lin, J.-D. D., Deng, C. X., Carson, P. L., Fowlkes, J. B., Tao, C., Liu, X., & Wang, X. (2016) · Scientific Reports · doi:10.1038/srep16937 · Cited by 51
Fila, G., Kasimova, K., Arenas, Y., Nakonieczna, J., Grinholc, M., Bielawski, K. P., & Lilge, L. D. (2016) · Frontiers in Microbiology · doi:10.3389/fmicb.2016.01258 · Cited by 52
Jonasson, H., Fredriksson, I., Bergstrand, S., Östgren, C. J., Larsson, M., & Strömberg, T. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.12.121608 · Cited by 52
Expanding the toolbox of photon upconversion for emerging frontier applications
Huang, J., Yan, L., Liu, S., Tao, L., & Zhou, B. (2022) · Materials Horizons · doi:10.1039/d1mh01654g · Cited by 52
Long-term in vivo imaging of mouse spinal cord through an optically cleared intervertebral window
Wu, W., He, S., Wu, J., Chen, C., Li, X., Liu, K., & Qu, J. Y. (2022) · Nature Communications · doi:10.1038/s41467-022-29496-x · Cited by 55
Hamann, A., & Carstengerdes, N. (2023) · Scientific Reports · doi:10.1038/s41598-023-31264-w · Cited by 51
Lin, L., He, H., Xue, R., Zhang, Y., Wang, Z., Nie, S., & Ye, J. (2023) · Med-X · doi:10.1007/s44258-023-00010-2 · Cited by 51
Optimising gold nanorods for photoacoustic imaging in vitro
Knights, O. B., Ye, S., Ingram, N., Freear, S., & McLaughlan, J. R. (2019) · Nanoscale Advances · doi:10.1039/c8na00389k · Cited by 50
Meng, H., Wang, K., Gao, Y., Jin, Y., Ma, X., & Tian, J. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2912222 · Cited by 51
Stimuli-responsive nanoparticle-assisted immunotherapy: a new weapon against solid tumours
Angelis, B. D., Depalo, N., Petronella, F., Quintarelli, C., Curri, M. L., Pani, R., Calogero, A., Locatelli, F., & Sio, L. D. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02246e · Cited by 53
Döge, N., Hadam, S., Volz, P., Wolf, A. M., Schönborn, K., Blume‐Peytavi, U., Alexiev, U., & Vogt, A. (2017) · Journal of Biophotonics · doi:10.1002/jbio.201700169 · Cited by 50
Witteveen, M., Sterenborg, H. J. C. M., van Leeuwen, T. G. J. M., Aalders, M. C. G., Ruers, T. J. M., & Post, A. L. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.10.106003 · Cited by 50
Roca, A. G., López-Barberá, J. F., Lafuente, A., Özel, F., Fantechi, E., Muro-Cruces, J., Hémadi, M., Sepúlveda, B., & Nogués, J. (2023) · Physics Reports · doi:10.1016/j.physrep.2023.10.003 · Cited by 51
Andreozzi, J. M., Zhang, R., Glaser, A. K., Jarvis, L. A., Pogue, B. W., & Gladstone, D. J. (2015) · Medical Physics · doi:10.1118/1.4906249 · Cited by 50
Towards the use of bioresorbable fibers in time‐domain diffuse optics
Sieno, L. D., Boetti, N. G., Mora, A. D. D., Pugliese, D., Farina, A., Sekar, S. K. V., Ceci‐Ginistrelli, E., Janner, D., Pifferi, A., & Milanese, D. (2017) · Journal of Biophotonics · doi:10.1002/jbio.201600275 · Cited by 50
Gao, Y., Wang, K., Jiang, S., Liu, Y., Ai, T., & Tian, J. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2737661 · Cited by 50
Matthews, T. P., & Anastasio, M. A. (2017) · Inverse Problems · doi:10.1088/1361-6420/aa9384 · Cited by 50
Single-Cell Analysis Using Hyperspectral Imaging Modalities
Mehta, N., Shaik, S. M., Devireddy, R. V., & Gartia, M. R. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4038638 · Cited by 50
Near‐Infrared Light Triggered‐Release in Deep Brain Regions Using Ultra‐photosensitive Nanovesicles
Xiong, H., Li, X., Kang, P., Perish, J. M., Neuhaus, F., Ploski, J. E., Kroener, S., Ogunyankin, M. O., Shin, J. E., Zasadzinski, J. A., et al. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201915296 · Cited by 50
Setchfield, K., Gorman, A., Simpson, A. H. R. W., Somekh, M. G., & Wright, A. J. (2023) · Biomedical Optics Express · doi:10.1364/boe.493588 · Cited by 49
Refractive index variance of cells and tissues measured by quantitative phase imaging
Shan, M., Kandel, M. E., & Popescu, G. (2017) · Optics Express · doi:10.1364/oe.25.001573 · Cited by 49
Afshari, A. A., Saager, R. B., Burgos, D. E., Vogt, W. C., Wang, J., Mendoza, G., Weininger, S., Sung, K., Durkin, A. J., & Pfefer, T. J. (2022) · Biomedical Optics Express · doi:10.1364/boe.454020 · Cited by 48
Ambrósio, L. A., & Zamboni‐Rached, M. (2015) · Journal of the Optical Society of America B · doi:10.1364/josab.32.000b37 · Cited by 49
King, D. R., Li, W., Squiers, J. J., Mohan, R., Sellke, E. W., Mo, W., Zhang, X., Fan, W., DiMaio, J. M., & Thatcher, J. E. (2015) · Burns · doi:10.1016/j.burns.2015.05.009 · Cited by 49
Experimental system for measuring the full scattering profile of circular phantoms
Feder, I., Duadi, H., & Fixler, D. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.002877 · Cited by 50
Farzam, P., Buckley, E. M., Lin, P., Hagan, K., Grant, P. E., Inder, T. E., Carp, S. A., & Franceschini, M. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-15995-1 · Cited by 49
Rajaram, A., Bale, G. M., Kewin, M. D., Morrison, L. B., Tachtsidis, I., Lawrence, K. S., & Diop, M. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.002588 · Cited by 49
All‐Polymer High‐Performance Photodetector through Lamination
Xia, Y., Aguirre, L. E., Xu, X., & Inganäs, O. (2020) · Advanced Electronic Materials · doi:10.1002/aelm.201901017 · Cited by 49
Kim, J., Chun, S. H., Amornkitbamrung, L., Song, C., Yuk, J. S., Ahn, S. Y., Kim, B. W., Lim, Y. T., Oh, B., & Um, S. H. (2020) · Nano Convergence · doi:10.1186/s40580-019-0216-z · Cited by 49
Zhang, Y., Kang, L., Wong, I. H. M., Dai, W., Li, X., Chan, R., Hsin, M. K. Y., & Wong, T. T. W. (2021) · Advanced Science · doi:10.1002/advs.202102358 · Cited by 49
Carbon Dioxide Sensing—Biomedical Applications to Human Subjects
Dervieux, E., Théron, M., & Uhring, W. (2021) · Sensors · doi:10.3390/s22010188 · Cited by 54
Cai, M., Zhang, Z., Shi, X., Hu, Z., & Tian, J. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.2964853 · Cited by 51
Large-scale voltage imaging in behaving mice using targeted illumination
Xiao, S., Lowet, E., Gritton, H. J., Fabris, P., Wang, Y., Sherman, J., Mount, R. A., Tseng, H.-A., Man, H., Straub, C., et al. (2021) · iScience · doi:10.1016/j.isci.2021.103263 · Cited by 48
Chen, Y., Spinelli, S., Gu, Z., & Pan, Z. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.137473 · Cited by 48
Light distribution and thermal effects in the rat brain under optogenetic stimulation
Gysbrechts, B., Wang, L., Trong, N. N. D., Cabral, H., Navratilova, Z., Battaglia, F. P., Saeys, W., & Bartic, C. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201500106 · Cited by 48
Dual phase lag model-based thermal analysis of tissue phantoms using lattice Boltzmann method
Patidar, S., Kumar, S., Srivastava, A. K., & Singh, S. (2016) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2015.12.011 · Cited by 48
Agut‐Busquet, E., Romaní, J., Gilaberte, Y., García‐Malinis, A. J., Ribera, M., & Luelmo, J. (2016) · Photochemical & Photobiological Sciences · doi:10.1039/c6pp00082g · Cited by 48
Ultrasound-guided spectral photoacoustic imaging of hemoglobin oxygenation during development
Bayer, C. L., Wlodarczyk, B. J., Finnell, R. H., & Emelianov, S. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000757 · Cited by 48
Tsui, S.-Y., Wang, C.-Y., Huang, T.-H., & Sung, K. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.001531 · Cited by 48
Metadata
- Authors
- Jacques, S. L.
- Affiliations
- Oregon Health & Science University (US)
- Corresponding author
- Jacques, Steven L
- ORCID
- Jacques, Steven L
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2013-05-10
- Volume
- 58
- Issue
- 11
- Pages
- R37-R61
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2097683070
- Cited by
- 4,008
- References
- 74
- Citations by year
- 2026: 350 · 2025: 346 · 2024: 313 · 2023: 332 · 2022: 323 · 2021: 362 · 2020: 363 · 2019: 383 · 2018: 320 · 2017: 299 · 2016: 272 · 2015: 217 · 2014: 107 · 2013: 15
- FWCI
- 28.94
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
- Keywords
- tissue optical properties, light scattering, optical absorption, chromophores, blood, melanin, fats, wavelength dependence, cell ultrastructure
- MeSH terms
- Animals, Biology, Humans, Anisotropy, Optical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review