Rotation sensing with a dual atom-interferometer Sagnac gyroscope
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
We reports improvements to our Sagnac effect matter-wave interferometer gyroscope. This device now has a short-term rotation-rate sensitivity of 6 × 10 -10 rad s -1 over 1 s of integration, which is the best publicly reported value to date. Stimulated Raman transitions are used to coherently manipulate atoms from counterpropagating thermal beams, forming two interferometers with opposite rotation phase shifts, allowing rotation to be distinguished from acceleration and laser arbitrary phase. Furthermore, electronically compensating the rotation-induced Doppler shifts of the Raman lasers allows operation at an effective zero rotation rate, improving sensitivity and facilitating sensitive lock-in detection readout techniques. Long-term stability is promising but not yet fully characterized. Potential applications include inertial navigation, geophysical studies and tests of general relativity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum Mechanics and Path Integrals
(1966) · Students Quarterly Journal · doi:10.1049/sqj.1966.0063 · Cited by 9,537
Atomic interferometry using stimulated Raman transitions
Kasevich, M., & Chu, S. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.181 · Cited by 1,377
Self-citationPrecision Rotation Measurements with an Atom Interferometer Gyroscope
Gustavson, T. L., Bouyer, P., & Kasevich, M. A. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.2046 · Cited by 785
Self-citationLense, J., & Thirring, H. (1918) · Physikalische Zeitschrift · Cited by 757
Measurement of the gravitational acceleration of an atom with a light-pulse atom interferometer
Kasevich, M., & Chu, S. (1992) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00325375 · Cited by 550
Self-citationOptical Ramsey spectroscopy in a rotating frame: Sagnac effect in a matter-wave interferometer
Riehle, F., Kisters, T., Witte, A., Helmcke, J., & Bordé, C. J. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.177 · Cited by 541
Effect of Earth's Rotation on the Quantum Mechanical Phase of the Neutron
Werner, S. A., Staudenmann, J. L., & Colella, R. (1979) · Physical Review Letters · doi:10.1103/physrevlett.42.1103 · Cited by 400
Ring-laser tests of fundamental physics and geophysics
Stedman, G. E. (1997) · Reports on Progress in Physics · doi:10.1088/0034-4885/60/6/001 · Cited by 399
Atomic velocity selection using stimulated Raman transitions
Kasevich, M., Weiss, D. S., Riis, E., Moler, K., Kasapi, S., & Chu, S. (1991) · Physical Review Letters · doi:10.1103/physrevlett.66.2297 · Cited by 305
Self-citationThe Feynman path integral approach to atomic interferometry. A tutorial
Storey, P., & Cohen-Tannoudji, C. (1994) · Journal de Physique II · doi:10.1051/jp2:1994103 · Cited by 252
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Kinoshita, T., Wenger, T., & Weiss, D. S. (2006) · Nature · doi:10.1038/nature04693 · Cited by 1,997
Optics and interferometry with atoms and molecules
Cronin, A. D., Schmiedmayer, J., & Pritchard, D. E. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.1051 · Cited by 1,420
Precision measurement of the Newtonian gravitational constant using cold atoms
Rosi, G., Sorrentino, F., Cacciapuoti, L., Prevedelli, M., & Tino, G. M. (2014) · Nature · doi:10.1038/nature13433 · Cited by 739
Nuclear Spin Gyroscope Based on an Atomic Comagnetometer
Kornack, T. W., Ghosh, R. K., & Romalis, M. V. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.230801 · Cited by 565
Six-Axis Inertial Sensor Using Cold-Atom Interferometry
Canuel, B., Leduc, F., Holleville, D., Gauguet, A., Fils, J., Virdis, A., Clairon, A., Dimarcq, N., Bordé, C. J., Landragin, A., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.010402 · Cited by 387
Self-citationMatter-gravity couplings and Lorentz violation
Kostelecký, V. A., & Tasson, J. D. (2011) · Physical Review D · doi:10.1103/physrevd.83.016013 · Cited by 341
Atom-Interferometry Tests of the Isotropy of Post-Newtonian Gravity
Müller, H., Chiow, S.-W., Herrmann, S., Chu, S., & Chung, K.-Y. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.031101 · Cited by 333
Kitching, J., Knappe, S., & Donley, E. A. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2157679 · Cited by 330
Limits to the sensitivity of a low noise compact atomic gravimeter
Le Gouët, J., Mehlstäubler, T. E., Kim, J., Merlet, S., Clairon, A., Landragin, A., & Pereira Dos Santos, F. (2008) · Applied Physics B · doi:10.1007/s00340-008-3088-1 · Cited by 294
Self-citationAtom interferometry with up to 24-photon-momentum-transfer beam splitters
Müller, H., Chiow, S.-W., Long, Q., Herrmann, S., & Chu, S. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.180405 · Cited by 290
Exploring gravity with the MIGA large scale atom interferometer
Canuel, B., Bertoldi, A., Amand, L., Pozzo di Borgo, E., Chantrait, T., Danquigny, C., Dovale Álvarez, M., Fang, B., Freise, A., Geiger, R., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-32165-z · Cited by 285
Self-citationIntegrated Mach–Zehnder interferometer for Bose–Einstein condensates
Berrada, T., van Frank, S., Bücker, R., Schumm, T., Schaff, J.-F., & Schmiedmayer, J. (2013) · Nature Communications · doi:10.1038/ncomms3077 · Cited by 276
Long-Term Stability of an Area-Reversible Atom-Interferometer Sagnac Gyroscope
Durfee, D. S., Shaham, Y. K., & Kasevich, M. A. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.240801 · Cited by 269
Self-citationFerrari, G., Poli, N., Sorrentino, F., & Tino, G. M. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.060402 · Cited by 265
Measurement of the Sensitivity Function in a Time-Domain Atomic Interferometer
Cheinet, P., Canuel, B., Pereira Dos Santos, F., Gauguet, A., Yver-Leduc, F., & Landragin, A. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.915148 · Cited by 251
“Atomic microwave clocks are the most precise realization of a SI unit, the second [1], and high sensitivity inertial sensors [2], [ 3 ], [4], based on atomic interferometry [5], already reveal accuracies comparable with state of the art sensors [6], [7].”
Self-citationSensitivity limits of a Raman atom interferometer as a gravity gradiometer
Sorrentino, F., Bodart, Q., Cacciapuoti, L., Lien, Y.-H., Prevedelli, M., Rosi, G., Salvi, L., & Tino, G. M. (2014) · Physical Review A · doi:10.1103/physreva.89.023607 · Cited by 228
Interleaved atom interferometry for high-sensitivity inertial measurements
Savoie, D., Altorio, M., Fang, B., Sidorenkov, L. A., Geiger, R., & Landragin, A. (2018) · Science Advances · doi:10.1126/sciadv.aau7948 · Cited by 224
Self-citationHigh-accuracy inertial measurements with cold-atom sensors
Geiger, R., Landragin, A., Merlet, S., & Pereira Dos Santos, F. (2020) · AVS Quantum Science · doi:10.1116/5.0009093 · Cited by 215
Self-citationInvited Review Article: Large ring lasers for rotation sensing
Schreiber, K. U., & Wells, J.-P. R. (2013) · Review of Scientific Instruments · doi:10.1063/1.4798216 · Cited by 207
Characterization and limits of a cold-atom Sagnac interferometer
Gauguet, A., Canuel, B., Lévèque, T., Chaibi, W., & Landragin, A. (2009) · Physical Review A · doi:10.1103/physreva.80.063604 · Cited by 201
Self-citationAdvances in Atomic Gyroscopes: A View from Inertial Navigation Applications
Fang, J., & Qin, J. (2012) · Sensors · doi:10.3390/s120506331 · Cited by 183
“4 × 10°/s/Hz in 2000 [22], and obtained a bias stability of 6.”
BackgroundMethodZAIGA: Zhaoshan long-baseline atom interferometer gravitation antenna
Zhan, M.-S., Wang, J., Ni, W.-T., Gao, D.-F., Wang, G., He, L.-X., Li, R.-B., Zhou, L., Chen, X., Zhong, J.-Q., et al. (2020) · International Journal of Modern Physics D · doi:10.1142/s0218271819400054 · Cited by 168
Principles and applications of control in quantum systems
Mabuchi, H., & Khaneja, N. (2005) · International Journal of Robust and Nonlinear Control · doi:10.1002/rnc.1016 · Cited by 168
Physics with coherent matter waves
Bongs, K., & Sengstock, K. (2004) · Reports on Progress in Physics · doi:10.1088/0034-4885/67/6/r03 · Cited by 165
Metadata
- Authors
- Gustavson, T. L., Landragin, A., & Kasevich, M. A.
- Venue
- Classical and Quantum Gravity
- Publisher
- IOP Publishing
- Published
- 2000-06-08
- Volume
- 17
- Issue
- 12
- Pages
- 2385-2398
- ISSN
- 0264-9381 (ISSN-L)
- 1361-6382
- OpenAlex
- W2054488787
- Cited by
- 470
- References
- 15
- FWCI
- 6.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.