The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Nuclear Spin Gyroscope Based on an Atomic Comagnetometer
Open accessAbstract
We describe a nuclear spin gyroscope based on an alkali-metal--noble-gas comagnetometer. Optically pumped alkali-metal vapor is used to polarize the noble-gas atoms and detect their gyroscopic precession. Spin precession due to magnetic fields as well as their gradients and transients can be cancelled in this arrangement. The sensitivity is enhanced by using a high-density alkali-metal vapor in a spin-exchange relaxation free regime. With a $\mathrm{K}\mathrm{\text{\ensuremath{-}}}^{3}\mathrm{He}$ comagnetometer we demonstrate rotation sensitivity of $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}\text{ }\text{ }\mathrm{rad}\text{ }{\mathrm{s}}^{\ensuremath{-}1}\text{ }{\mathrm{Hz}}^{\ensuremath{-}1/2}$, equivalent to a magnetic field sensitivity of $2.5\text{ }\text{ }\mathrm{fT}/{\mathrm{Hz}}^{1/2}$. The rotation signal can be increased by a factor of 10 using $^{21}\mathrm{Ne}$ with a smaller magnetic moment. The comagnetometer is also a promising tool in searches for anomalous spin couplings beyond the standard model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citationLimit on Lorentz and CPT Violation of the Neutron Using a Two-Species Noble-Gas Maser
Bear, D., Stoner, R. E., Walsworth, R. L., Kostelecký, V. A., & Lane, C. D. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.5038 · Cited by 309
Bear, D., Stoner, R. E., Walsworth, R. L., Kostelecký, V. A., & Lane, C. D. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.209902 · Cited by 45
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Self-citationKitching, J. (2018) · Applied Physics Reviews · doi:10.1063/1.5026238 · Cited by 621
Limits on New Long Range Nuclear Spin-Dependent Forces Set with aK−He3Comagnetometer
Vasilakis, G., Brown, J. M., Kornack, T. W., & Romalis, M. V. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.261801 · Cited by 310
Self-citationSearch for topological defect dark matter with a global network of optical magnetometers
Afach, S., Buchler, B. C., Budker, D., Dailey, C., Derevianko, A., Dumont, V., Figueroa, N. L., Gerhardt, I., Grujić, Z. D., Guo, H., et al. (2021) · Nature Physics · doi:10.1038/s41567-021-01393-y · Cited by 126
Self-citation
Metadata
- Authors
- Kornack, T. W., Ghosh, R. K., & Romalis, M. V.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2005-11-29
- Volume
- 95
- Issue
- 23
- Pages
- 230801-230801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1998320990
- Cited by
- 565
- References
- 3
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nuclear Spin Gyroscope Based on an Atomic Comagnetometer. https://app.cochat.ai/papers/10.1103/physrevlett.95.230801
- The paper
- Kornack, T. W., Ghosh, R. K., & Romalis, M. V. (2005). Nuclear Spin Gyroscope Based on an Atomic Comagnetometer. Physical Review Letters. https://doi.org/10.1103/physrevlett.95.230801
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.