Optical tomography in medical imaging
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
We present a review of methods for the forward and inverse problems in optical tomography. We limit ourselves to the highly scattering case found in applications in medical imaging, and to the problem of absorption and scattering reconstruction. We discuss the derivation of the diffusion approximation and other simplifications of the full transport problem. We develop sensitivity relations in both the continuous and discrete case with special concentration on the use of the finite element method. A classification of algorithms is presented, and some suggestions for open problems to be addressed in future research are made.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
Diffuse radiation in the Galaxy
Henyey, L. C., & Greenstein, J. L. (1941) · The Astrophysical Journal · doi:10.1086/144246 · Cited by 2,913
Case, K. M., Zweifel, P. F., & Pomraning, G. C. (1968) · Physics Today · doi:10.1063/1.3034554 · Cited by 1,609
Duderstadt, J. J., & Hamilton, L. J. (1976) · Deep Blue (University of Michigan) · Cited by 1,603
A Monte Carlo model for the absorption and flux distributions of light in tissue
Wilson, B. C., & Adam, G. (1983) · Medical Physics · doi:10.1118/1.595361 · Cited by 690
A finite element approach for modeling photon transport in tissue
Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T. (1993) · Medical Physics · doi:10.1118/1.597069 · Cited by 635
Self-citationOptical imaging in medicine: II. Modelling and reconstruction
Arridge, S. R., & Hebden, J. C. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/5/008 · Cited by 495
Self-citationScattering and absorption of turbid materials determined from reflection measurements 1: Theory
Groenhuis, R. A. J., Ferwerda, H. A., & Ten Bosch, J. J. (1983) · Applied Optics · doi:10.1364/ao.22.002456 · Cited by 490
Okada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Self-citationExperimental images of heterogeneous turbid media by frequency-domain diffusing-photon tomography
O’Leary, M. A., Boas, D. A., Chance, B., & Yodh, A. G. (1995) · Optics Letters · doi:10.1364/ol.20.000426 · Cited by 440
Cited by
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
“Optical macroscopy has been two decades in development toward quantitative in vivo imagin”
BackgroundDiffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Self-citationNtziachristos, V., Bremer, C., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1524-x · Cited by 982
Non-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903
Fluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827
Image transmission through an opaque material
Popoff, S., Lerosey, G., Fink, M., Boccara, A. C., & Gigan, S. (2010) · Nature Communications · doi:10.1038/ncomms1078 · Cited by 755
FLUORESCENCE MOLECULAR IMAGING
Ntziachristos, V. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095831 · Cited by 731
Dehghani, H., Eames, M. E., Yalavarthy, P. K., Davis, S. C., Srinivasan, S., Carpenter, C. M., Pogue, B. W., & Paulsen, K. D. (2009) · Communications in Numerical Methods in Engineering · doi:10.1002/cnm.1162 · Cited by 728
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Quantitative spectroscopic photoacoustic imaging: a review
Cox, B., Laufer, J. G., Arridge, S. R., & Beard, P. C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.061202 · Cited by 720
Self-citationImaging the body with diffuse optical tomography
Boas, D. A., Brooks, D. H., Miller, E. L., DiMarzio, C. A., Kilmer, M., Gaudette, R. J., & Zhang, Q. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962278 · Cited by 718
Guidestar-assisted wavefront-shaping methods for focusing light into biological tissue
Horstmeyer, R., Ruan, H., & Yang, C. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.140 · Cited by 651
Optical tomography: forward and inverse problems
Arridge, S. R., & Schotland, J. C. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123010 · Cited by 625
Self-citationProgress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Zhan, Q., Qian, J., Liang, H., Somesfalean, G., Wang, D., He, S., Zhang, Z., & Andersson-Engels, S. (2011) · ACS Nano · doi:10.1021/nn200110j · Cited by 523
Functional near-infrared spectroscopy: current status and future prospects
Hoshi, Y. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804911 · Cited by 468
Time domain functional NIRS imaging for human brain mapping
Torricelli, A., Contini, D., Pifferi, A., Caffini, M., Re, R., Zucchelli, L., & Spinelli, L. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.106 · Cited by 466
Statistical analysis of fNIRS data: A comprehensive review
Tak, S., & Ye, J. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.016 · Cited by 465
The Accuracy of Near Infrared Spectroscopy and Imaging during Focal Changes in Cerebral Hemodynamics
Boas, D. A., Gaudette, T., Strangman, G., Cheng, X., Marota, J. J. A., & Mandeville, J. B. (2001) · NeuroImage · doi:10.1006/nimg.2000.0674 · Cited by 459
Polydorides, N., & Lionheart, W. R. B. (2002) · Measurement Science and Technology · doi:10.1088/0957-0233/13/12/310 · Cited by 454
EIT reconstruction algorithms: pitfalls, challenges and recent developments
Lionheart, W. R. B. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/1/021 · Cited by 447
The NIRS Brain AnalyzIR Toolbox
Santosa, H., Zhai, X., Fishburn, F., & Huppert, T. (2018) · Algorithms · doi:10.3390/a11050073 · Cited by 440
Optical brain imaging in vivo: techniques and applications from animal to man
Hillman, E. M. C. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2789693 · Cited by 436
Anatomical guidance for functional near-infrared spectroscopy: AtlasViewer tutorial
Aasted, C. M., Yücel, M. A., Cooper, R. J., Dubb, J., Tsuzuki, D., Becerra, L., Petkov, M. P., Borsook, D., Dan, I., & Boas, D. A. (2015) · Neurophotonics · doi:10.1117/1.nph.2.2.020801 · Cited by 409
Statistical inversion and Monte Carlo sampling methods in electrical impedance tomography
Kaipio, J. P., Kolehmainen, V., Somersalo, E., & Vauhkonen, M. (2000) · Inverse Problems · doi:10.1088/0266-5611/16/5/321 · Cited by 363
Tutorial on diffuse light transport
Jacques, S. L., & Pogue, B. W. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2967535 · Cited by 354
Ntziachristos, V., Schellenberger, E. A., Ripoll, J., Yessayan, D., Graves, E., Bogdanov, A., Josephson, L., & Weissleder, R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0401137101 · Cited by 348
Hawrysz, D. J., & Sevick-Muraca, E. M. (2000) · Neoplasia · doi:10.1038/sj.neo.7900118 · Cited by 340
In vivo molecular and genomic imaging: new challenges for imaging physics
Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/r01 · Cited by 334
Underwater Optical Imaging: The Past, the Present, and the Prospects
Jaffe, J. S. (2015) · IEEE Journal of Oceanic Engineering · doi:10.1109/joe.2014.2350751 · Cited by 312
Hillman, E. M. C., Devor, A., Bouchard, M. B., Dunn, A. K., Krauss, G. W., Skoch, J., Bacskai, B. J., Dale, A. M., & Boas, D. A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.032 · Cited by 289
Three-dimensional optical tomography of the premature infant brain
Hebden, J. C., Gibson, A., Yusof, R. M., Everdell, N., Hillman, E. M. C., Delpy, D. T., Arridge, S. R., Austin, T., Meek, J. H., & Wyatt, J. S. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/23/303 · Cited by 288
Self-citationThermal Radiation in Disperse Systems: An Engineering Approach
Dombrovsky, L. A., & Baillis, D. (2010) · doi:10.1615/978-1-56700-268-3.0 · Cited by 284
Ale, A., Ermolayev, V., Herzog, E., Cohrs, C., de Angelis, M. H., & Ntziachristos, V. (2012) · Nature Methods · doi:10.1038/nmeth.2014 · Cited by 276
Dehghani, H., Pogue, B. W., Poplack, S. P., & Paulsen, K. D. (2003) · Applied Optics · doi:10.1364/ao.42.000135 · Cited by 274
Hyperspectral and multispectral bioluminescence optical tomography for small animal imaging
Chaudhari, A. J., Darvas, F., Bading, J. R., Moats, R. A., Conti, P. S., Smith, D. J., Cherry, S. R., & Leahy, R. M. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/23/001 · Cited by 273
Diffuse optical imaging using spatially and temporally modulated light
O’Sullivan, T. D., Cerussi, A. E., Cuccia, D. J., & Tromberg, B. J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.071311 · Cited by 270
Tsuzuki, D., & Dan, I. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.025 · Cited by 265
A 32-channel time-resolved instrument for medical optical tomography
Schmidt, F. E. W., Fry, M. E., Hillman, E. M. C., Hebden, J. C., & Delpy, D. T. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150191 · Cited by 260
Overview of diffuse optical tomography and its clinical applications
Hoshi, Y., & Yamada, Y. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091312 · Cited by 249
“The DE is derived from a diffusion approximation to the RTE in which the intensity Iðr;Ω; tÞ is approximated by the first two terms of a series expansion in spherical harmonics (P1 approximation), the temporal variation in the flux vector [Jðr;tÞ1⁄4 ∫ 4πΩIðr;Ω;tÞdΩ] is assumed to be negligible, and the light source is…”
MethodZhou, C., Yu, G., Furuya, D., Greenberg, J. H., Yodh, A. G., & Durduran, T. (2006) · Optics Express · doi:10.1364/oe.14.001125 · Cited by 232
Approximation errors and model reduction with an application in optical diffusion tomography
Arridge, S. R., Kaipio, J. P., Kolehmainen, V, Schweiger, M., Somersalo, E., Tarvainen, T., & Vauhkonen, M. (2006) · Inverse Problems · doi:10.1088/0266-5611/22/1/010 · Cited by 221
Self-citationCombined Optical and X-ray Tomosynthesis Breast Imaging
Fang, Q., Selb, J., Carp, S. A., Boverman, G., Miller, E. L., Brooks, D. H., Moore, R. H., Kopans, D. B., & Boas, D. A. (2011) · Radiology · doi:10.1148/radiol.10082176 · Cited by 207
The inverse source problem based on the radiative transfer equation in optical molecular imaging
Klose, A. D., Ntziachristos, V., & Hielscher, A. H. (2005) · Journal of Computational Physics · doi:10.1016/j.jcp.2004.07.008 · Cited by 207
“More details of the DE method can be found in [75–77].”
BackgroundMethodGauss–Newton method for image reconstruction in diffuse optical tomography
Schweiger, M., Arridge, S. R., & Nissilä, I. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/10/013 · Cited by 206
“…considered, the type of solutions being sought, the physical model assumed for light propagation, and in the algorithmic details; for reviews see Arridge (1993, 1999), Yodh and Chance (1995), Hebden et al (1997), Arridge and Hebden (1997), Hawysz and Sevick-Muraca (2000), Boas et al (2001) and…”
BackgroundMethodInfluentialSelf-citationLutzweiler, C., & Razansky, D. (2013) · Sensors · doi:10.3390/s130607345 · Cited by 203
“It models the light transport as integro-differential equation and holds for both ballistic and diffuse photons [83,130–132].”
BackgroundDarne, C., Lu, Y., & Sevick-Muraca, E. M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/1/r1 · Cited by 199
“…that although fluorescence optical tomography is an emerging imaging modality, optical tomography has been around for more than two decades (Arridge 1999) and developed from DOT, which seeks to reconstruct interior maps of endogenous scattering and absorption properties using…”
BackgroundMethodInfluentialMULTIMODALITY IN VIVO IMAGING SYSTEMS: Twice the Power or Double the Trouble?
Cherry, S. R. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095728 · Cited by 188
“raphy, is also being pursued for clinical applications, especially for breast imaging and neonatal brain imaging (94).”
Thermoacoustic Molecular Imaging of Small Animals
Kruger, R. A., Kiser, W. L., Reinecke, D. R., Kruger, G. A., & Miller, K. D. (2003) · Molecular Imaging · doi:10.1162/15353500200303109 · Cited by 187
Review of optical breast imaging and spectroscopy
Grosenick, D., Rinneberg, H., Cubeddu, R., & Taroni, P. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091311 · Cited by 187
Jermyn, M., Ghadyani, H., Mastanduno, M. A., Turner, W., Davis, S. C., Dehghani, H., & Pogue, B. W. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.8.086007 · Cited by 186
“Numerical approaches allow solutions to be computed for more complex geometries, but require more computational time as well as a discrete representation (volume mesh) of the domain.(7,8) Due to the generally poor spatial resolution of DOT, the prevailing trend in the field is toward combining it with other imaging mo…”
Protease sensors for bioimaging
Funovics, M., Weissleder, R., & Tung, C.-H. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2199-0 · Cited by 186
Inverse transport theory and applications
Bal, G. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/5/053001 · Cited by 185
“The method is very similar to the inverse problem for the diffusion equation (34) (with c(x) = c constant) as it is used in optical tomography [6].”
BackgroundMethodOptimization of optode arrangements for diffuse optical tomography: A singular-value analysis
Culver, J. P., Ntziachristos, V., Holboke, M. J., & Yodh, A. G. (2001) · Optics Letters · doi:10.1364/ol.26.000701 · Cited by 183
Brooksby, B. A., Dehghani, H., Pogue, B. W., & Paulsen, K. D. (2003) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2003.813304 · Cited by 174
“N RECENT years, near-infrared (NIR) tomography has been investigated as a promising method of obtaining new types of physiological information from tissue [ 1 ]‐[8].”
MethodEstimating chromophore distributions from multiwavelength photoacoustic images
Cox, B. T., Arridge, S. R., & Beard, P. C. (2009) · Journal of the Optical Society of America A · doi:10.1364/josaa.26.000443 · Cited by 174
Self-citationFluorescence Molecular Tomography: Principles and Potential for Pharmaceutical Research
Stuker, F., Ripoll, J., & Rudin, M. (2011) · Pharmaceutics · doi:10.3390/pharmaceutics3020229 · Cited by 173
“A detailed description of solution techniques for the inverse problem is beyond the scope of this review article and the interested reader is referred to the literature [8,30].”
BackgroundOptical imaging and spectroscopy for the study of the human brain: status report
Ayaz, H., Baker, W. B., Blaney, G., Boas, D. A., Bortfeld, H., Brady, K., Brake, J., Brigadoi, S., Buckley, E. M., Carp, S. A., et al. (2022) · Neurophotonics · doi:10.1117/1.nph.9.s2.s24001 · Cited by 170
“As systems develop that provide additional datasets, such as multiple-wavelengths, phase, and time-of-flight, both imaging and parameter recovery become more challenging due to the multi-parameter optimization required to derive many sets of unknown parameters from limited measurements.(200) To allow quantitative DOT,…”
BackgroundHigh-density diffuse optical tomography for imaging human brain function
Wheelock, M. D., Culver, J. P., & Eggebrecht, A. T. (2019) · Review of Scientific Instruments · doi:10.1063/1.5086809 · Cited by 168
Boas, D. A., Chen, K., Grebert, D., & Franceschini, M. A. (2004) · Optics Letters · doi:10.1364/ol.29.001506 · Cited by 166
White, B. R., & Culver, J. P. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3368999 · Cited by 162
“14 This technique provides better spatial sampling and a more robust approach to image reconstruction, which in turn provides better localization and resolution of the imaged activations.”
Gregg (2010) · Frontiers in Neuroenergetics · doi:10.3389/fnene.2010.00014 · Cited by 161
“Second, overlapping measurements allow tomographic image reconstruction techniques (Barbour et al., 1990; Arridge, 1999; Yodh and Boas, 2003), resulting in an image of hemodynamic changes throughout a three-dimensional volume of the head, spatially separating contributions from deep and shallow…”
InfluentialGibson, A., & Dehghani, H. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0080 · Cited by 159
“This process is not straightforward, as the sensitivity matrix is ill-posed and underdetermined (Arridge 1999; Boas et al. 2001a; Schweiger et al. 2003; Gibson et al. 2005).”
BackgroundMethodContrast Agents for Optical Imaging
Licha, K. (2002) · Topics in Current Chemistry · doi:10.1007/3-540-46009-8_1 · Cited by 159
Near‐Infrared Diffuse Optical Tomography
Hielscher, A. H., Bluestone, A. Y., Abdoulaev, G. S., Klose, A. D., Lasker, J., Stewart, M., Netz, U., & Beuthan, J. (2002) · Disease Markers · doi:10.1155/2002/164252 · Cited by 159
Affective and non-affective touch evoke differential brain responses in 2-month-old infants
Jönsson, E. H., Kotilahti, K., Heiskala, J., Wasling, H. B., Olausson, H., Croy, I., Mustaniemi, H., Hiltunen, P., Tuulari, J. J., Scheinin, N. M., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.024 · Cited by 143
Li, L., Zeng, L., Lin, Z.-J., Cazzell, M., & Liu, H. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.5.050801 · Cited by 78
Interdependence of Kinetics and Fluid Dynamics in the Design of Photocatalytic Membrane Reactors
Chakachaka, V., Tshangana, C., Mahlangu, O., Mamba, B., & Muleja, A. (2022) · Membranes · doi:10.3390/membranes12080745 · Cited by 21
Metadata
- Authors
- Arridge, S. R.
- Venue
- Inverse Problems
- Publisher
- IOP Publishing
- Published
- 1999-01-01
- Volume
- 15
- Issue
- 2
- Pages
- R41-R93
- ISSN
- 0266-5611 (ISSN-L)
- 1361-6420
- OpenAlex
- W2033106066
- Cited by
- 2,524
- References
- 28
- FWCI
- 48.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.