An adaptive tuned mass damper based on the emulation of positive and negative stiffness with an MR damper
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper presents a new adaptive tuned mass damper (TMD) whose stiffness and damping can be tuned in real-time to changing frequencies of a target structure. The adaptive TMD consists of a tuned mass, a tuned passive spring and a magnetorheological (MR) damper. The MR damper is used to emulate controlled friction–viscous damping and controlled stiffness. The controlled positive or negative stiffness emulated by the MR damper works in parallel to the stiffness of the passive TMD spring. The resulting overall TMD stiffness can therefore be varied around the passive spring stiffness using the MR damper. Both the emulated stiffness and friction–viscous damping in the MR damper are controlled such that the resulting overall TMD stiffness and damping are adjusted according to Den Hartog's formulae. Simulations demonstrate that the adaptive TMD with a controlled MR damper provides the same reduction of steady state vibration amplitudes in the target structure as a passive TMD if the target structure vibrates at the nominal frequency. However, if the target structure vibrates at different frequencies, e.g. due to changed service loads, the adaptive TMD with a controlled MR damper outperforms the passive TMD by up to several 100% depending on the frequency change.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nagarajaiah, S. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.349 · Cited by 256
Frequency analysis of the tuned mass damper
Krenk, S. (2005) · Journal of Applied Mechanics · doi:10.1115/1.2062867 · Cited by 217
Research works printed but not linked: 32
- Den Hartog J P, 1934, Mechanical Vibrations
- Qin L, 2009, Earthq. Eng. Eng. Vib., 29, 153
- 10.1109/TPEL.2009.2033274 · DOI
- 10.2749/101686607781645806 · DOI
- 10.1002/stc.248 · DOI
- Hazra B, 2010, Smart Mater. Struct., 19, 115002, 10.1088/0964-1726/19/11/115002 · DOI
- 10.1016/j.engstruct.2010.08.011 · DOI
- 10.1117/12.657754 · DOI
- 10.1177/1045389X06073641 · DOI
- 10.1061/(ASCE)0733-9445(2007)133:1(67) · doi:10.1061/(asce)0733-9445(2007)133:1(67 · Paper page
- Rizos D, 2010, Mech. Syst. Signal Process.
- 10.1016/j.jsv.2003.12.040 · DOI
- Sun W-Q, 2009, Harbin Gongye Daxue Xuebao/J. Harbin Inst. Technol., 41, 164
- Li D, 2005, Proc. SPIE-Int. Soc. Opt. Eng., 5760, 56, 501-9
- Chen Y-H, 2008, Struct. Eng. Mech., 30, 1, 10.12989/sem.2008.30.1.001 · doi:10.12989/sem.2008.30.1.001
- 10.1002/stab.200810022 · DOI
- 10.1061/(ASCE)0733-9399(2004)130:4(524) · doi:10.1061/(asce)0733-9399(2004)130:4(524
- 10.1002/stc.49 · doi:10.1002/stc.49
- 10.1111/j.1467-8667.2005.00375.x · DOI · Paper page
- 10.1061/(ASCE)0733-9445(2005)131:6(900) · doi:10.1061/(asce)0733-9445(2005)131:6(900
- 10.1260/136943307781422208 · DOI · Paper page
- Boston C, 2009, Smart Mater. Struct., 18, 055006, 10.1088/0964-1726/18/5/055006 · DOI
- 10.1061/(ASCE)0733-9399(2004)130:4(451) · doi:10.1061/(asce)0733-9399(2004)130:4(451 · Paper page
- 10.1016/j.engstruct.2004.10.015 · DOI · Paper page
- 10.1061/(ASCE)1084-0702(2007)12:4(401) · doi:10.1061/(asce)1084-0702(2007)12:4(401
- Høgsberg J, 2009, Struct. Control Health Monit.
- Weber F, 2009, Smart Mater. Struct., 18, 015005, 10.1088/0964-1726/18/1/015005 · doi:10.1088/0964-1726/18/1/015005
- 10.1061/(ASCE)0733-9445(2010)136:2(123) · doi:10.1061/(asce)0733-9445(2010)136:2(123
- Weber F, 2010, Smart Mater. Struct., 19, 045025, 10.1088/0964-1726/19/4/045025 · doi:10.1088/0964-1726/19/4/045025
- Boston C, 2010, Smart Mater. Struct., 19, 045005, 10.1088/0964-1726/19/4/045005 · doi:10.1088/0964-1726/19/4/045005
- Boston C, 2010, J. Dyn. Syst. Meas. Control
- Bachmann H, 1995, Vibration Problems in Structures: Practical Guidelines, 10.1007/978-3-0348-9231-5 · DOI
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Semi-active vibration absorber based on real-time controlled MR damper
Weber, F. (2014) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2014.01.017 · Cited by 180
Self-citationMagnetic negative stiffness dampers
Shi, X., & Zhu, S. (2015) · Smart Materials and Structures · doi:10.1088/0964-1726/24/7/072002 · Cited by 156
Application of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review
Rahimi, F., Aghayari, R., & Samali, B. (2020) · Civil Engineering Journal · doi:10.28991/cej-2020-03091571 · Cited by 138
Metadata
- Authors
- Weber, F., Boston, C., & Maślanka, M.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2010-12-09
- Volume
- 20
- Issue
- 1
- Pages
- 015012
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2078707237
- Cited by
- 97
- References
- 2
- FWCI
- 14.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An adaptive tuned mass damper based on the emulation of positive and negative stiffness with an MR damper. https://app.cochat.ai/papers/10.1088/0964-1726/20/1/015012
- The paper
- Weber, F., Boston, C., & Maślanka, M. (2011). An adaptive tuned mass damper based on the emulation of positive and negative stiffness with an MR damper. Smart Materials and Structures. https://doi.org/10.1088/0964-1726/20/1/015012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.