Magnetic actuated pH-responsive hydrogel-based soft micro-robot for targeted drug delivery
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Abstract For drug delivery in cancer therapy, various stimuli-responsive hydrogel-based micro-devices have been studied with great interest. Here, we present a new concept for a hybrid actuated soft microrobot targeted drug delivery. The proposed soft microrobot consists of a hydrogel bilayer structure of 2-hydroxyethyl methacrylate (PHEMA) and poly (ethylene glycol) acrylate (PEGDA) with iron (II, III) oxide particles (Fe 3 O 4 ). The PHEMA layer as a pH-responsive gel is used for a trapping and unfolding motion of the soft microrobot in pH-varying solution, and the PEGDA-with-Fe 3 O 4 layer is employed for the locomotion of the soft microrobot in the magnetic field. The bilayer soft microrobot was fabricated by a conventional photolithography procedure and its characteristics were analyzed and presented. To evaluate the trapping performance and the motility of the soft microrobot, test solutions with different pH values and an electromagnetic actuation (EMA) system were used. First, the soft microrobot showed its full trapping motion at about pH 9.58 and its unfolding motion at about pH 2.6. Second, the soft microrobot showed a moving velocity of about 600 μ m s −1 through the generated magnetic field of the EMA system. Finally, we fabricated the real anti-cancer drug microbeads (PCL-DTX) and executed the cytotoxicity test using the mammary carcinoma cells (4T1). The viability of the 4T1 cells treated with the proposed microrobot and the PCL-DTX microbeads decreased to 70.25 ± 1.52%. The result demonstrated that the soft microrobot can be moved to a target position by the EMA system and can release a small amount of beads by the pH variation and the robot exhibited no toxicity to the cells. In the future, we expect that the proposed soft microrobot can be applied to a new tumor-therapeutic tool that can move to a target tumor and release anti-tumor drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Bray, F., Center, M. M., Ferlay, J., Ward, E., & Forman, D. (2011) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20107 · Cited by 54,679
Siegel, R., Naishadham, D., & Jemal, A. (2013) · CA A Cancer Journal for Clinicians · doi:10.3322/caac.21166 · Cited by 11,825
Nanoparticle and targeted systems for cancer therapy
Brannon-Peppas, L., & Blanchette, J. O. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.02.014 · Cited by 2,334
Nanoparticle and targeted systems for cancer therapy
Brannon-Peppas, L., & Blanchette, J. O. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.033 · Cited by 796
Review on Hydrogel-based pH Sensors and Microsensors
Richter, A., Paschew, G., Klatt, S., Lienig, J., Arndt, K.-F., & Adler, H.-J. P. (2008) · Sensors · doi:10.3390/s8010561 · Cited by 742
Hydrogel-based actuators: possibilities and limitations
Ionov, L. (2014) · Materials Today · doi:10.1016/j.mattod.2014.07.002 · Cited by 680
Light-Controlled Graphene-Elastin Composite Hydrogel Actuators
Wang, E., Desai, M. S., & Lee, S.-W. (2013) · Nano Letters · doi:10.1021/nl401088b · Cited by 574
The chemistry, physiology and pathology of pH in cancer
Swietach, P., Vaughan-Jones, R. D., Harris, A. L., & Hulikova, A. (2014) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2013.0099 · Cited by 539
Glucose-Responsive Microgels Integrated with Enzyme Nanocapsules for Closed-Loop Insulin Delivery
Gu, Z., Dang, T. T., Ma, M., Tang, B. C., Cheng, H., Jiang, S., Dong, Y., Zhang, Y., & Anderson, D. G. (2013) · ACS Nano · doi:10.1021/nn401617u · Cited by 428
Electro-actuated hydrogel walkers with dual responsive legs
Morales, D., Palleau, E., Dickey, M. D., & Velev, O. D. (2014) · Soft Matter · doi:10.1039/c3sm51921j · Cited by 366
An Integrated Microrobotic Platform for On‐Demand, Targeted Therapeutic Interventions
Fusco, S., Sakar, M. S., Kennedy, S., Peters, C., Bottani, R., Starsich, F., Mao, A., Sotiriou, G. A., Pané, S., Pratsinis, S. E., et al. (2014) · Advanced Materials · doi:10.1002/adma.201304098 · Cited by 321
Magneto–Acoustic Hybrid Nanomotor
Li, J., Li, T., Xu, T., Kiristi, M., Liu, W., Wu, Z., & Wang, J. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b01945 · Cited by 295
Loss of Halophytism by Interference with SOS1 Expression
Oh, D.-H., Leidi, E., Zhang, Q., Hwang, S.-M., Li, Y., Quintero, F. J., Jiang, X., D'Urzo, M. P., Lee, S. Y., Zhao, Y., et al. (2009) · Plant Physiology · doi:10.1104/pp.109.137802 · Cited by 293
Nemir, S., Hayenga, H. N., & West, J. L. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22574 · Cited by 282
Photolithographically patterned smart hydrogel based bilayer actuators
Bassik, N., Abebe, B. T., Laflin, K. E., & Gracias, D. H. (2010) · Polymer · doi:10.1016/j.polymer.2010.10.035 · Cited by 242
Multilayer microfluidic PEGDA hydrogels
Cuchiara, M. P., Allen, A. C. B., Chen, T. M., Miller, J. S., & West, J. L. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.031 · Cited by 236
New paradigm for tumor theranostic methodology using bacteria-based microrobot
Park, S. J., Park, S.-H., Cho, S., Kim, D.-M., Lee, Y., Ko, S. Y., Hong, Y., Choy, H. E., Min, J.-J., Park, J.-O., et al. (2013) · Scientific Reports · doi:10.1038/srep03394 · Cited by 230
Self-citationDrug targeting to the colon with lectins and neoglycoconjugates
Minko, T. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.017 · Cited by 222
Targeted therapy for cancer using pH-responsive nanocarrier systems
Manchun, S., Dass, C. R., & Sriamornsak, P. (2012) · Life Sciences · doi:10.1016/j.lfs.2012.01.008 · Cited by 208
Yu, C., Duan, Z., Yuan, P., Li, Y., Su, Y., Zhang, X., Pan, Y., Dai, L. L., Nuzzo, R. G., Huang, Y., et al. (2013) · Advanced Materials · doi:10.1002/adma.201204180 · Cited by 193
Self-Folding of Three-Dimensional Hydrogel Microstructures
Guan, J., He, H., Hansford, D. J., & Lee, L. J. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp054341g · Cited by 191
Ionov, L. (2015) · Langmuir · doi:10.1021/la503407z · Cited by 179
Stimuli‐Responsive Polymeric Nanoparticles for Nanomedicine
Crucho, C. I. C. (2015) · ChemMedChem · doi:10.1002/cmdc.201402290 · Cited by 173
Microparticles and their emerging role in cancer multidrug resistance
Gong, J., Jaiswal, R., Mathys, J.-M., Combes, V., Grau, G. E. R., & Bebawy, M. (2012) · Cancer Treatment Reviews · doi:10.1016/j.ctrv.2011.06.005 · Cited by 165
An oral delivery device based on self-folding hydrogels
He, H., Guan, J., & Lee, J. L. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.10.017 · Cited by 161
Light-induced tailoring of PEG-hydrogel properties
Andreopoulos, F. M., Beckman, E. J., & Russell, A. J. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00219-6 · Cited by 127
Tong, Z., Luo, W., Wang, Y.-Q., Yang, F., Han, Y., Li, H., Luo, H., Duan, B., Xu, T., Mao‐Ying, Q., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010234 · Cited by 125
Self-citationInfluence of Tumor pH on Therapeutic Response
Song, C. W., Griffin, R. J., & Park, H. J. (2007) · Humana Press eBooks · doi:10.1007/978-1-59745-035-5_2 · Cited by 97
Glucose-responsive hydrogels based on dynamic covalent chemistry and inclusion complexation
Yang, T., Ji, R., Deng, X., Du, F., & Li, Z. (2014) · Soft Matter · doi:10.1039/c3sm53059k · Cited by 95
Uniform Beads with Controllable Pore Sizes for Biomedical Applications
Choi, S., Yeh, Y., Zhang, Y., Sung, H., & Xia, Y. (2010) · Small · doi:10.1002/smll.201000544 · Cited by 81
Position-based magnetic field control for an electromagnetic actuated microrobot system
Go, G., Choi, H. C., Jeong, S., Lee, C. J., Park, B. J., Ko, S. Y., Park, J., & Park, S. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.11.014 · Cited by 21
Self-citation
Cited by
Magnetically Driven Micro and Nanorobots
Zhou, H., Mayorga-Martinez, C. C., Pané, S., Zhang, L., & Pumera, M. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01234 · Cited by 889
Soft actuators for real-world applications
Li, M., Pal, A., Aghakhani, A., Pena-Francesch, A., & Sitti, M. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00389-7 · Cited by 880
Palagi, S., & Fischer, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0016-9 · Cited by 716
Lee, Y., Song, W. J., & Sun, J.-Y. (2020) · Materials Today Physics · doi:10.1016/j.mtphys.2020.100258 · Cited by 507
Multifunctional magnetic soft composites: a review
Wu, S., Hu, W., Ze, Q., Sitti, M., & Zhao, R. (2020) · Multifunctional Materials · doi:10.1088/2399-7532/abcb0c · Cited by 307
Metadata
- Authors
- Li, H., Go, G., Ko, S. Y., Park, J.-O., & Park, S.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2016-01-21
- Volume
- 25
- Issue
- 2
- Pages
- 027001
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W2519772645
- Cited by
- 394
- References
- 31
- FWCI
- 14.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.