CoChat

Comparison of the Bod Pod and dual energy x-ray absorptiometry in men

Open access
Ball, Stephen D, Altena, Thomas S · 2004 · Physiological Measurement
Cited by 46

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

The majority of studies investigating the accuracy of the Bod Pod have compared it to hydrostatic weighing (HW), the long held, and perhaps outdated 'gold standard' method of body composition analysis. Much less research has compared the Bod Pod to dual energy x-ray absorptiometry (DXA), a technique that is becoming popular as an alternative reference method. The purpose of this study was to compare per cent fat estimates by the Bod Pod to those of DXA in a large number of men. Participants were 160 men (32 +/- 11 years). Per cent body fat was estimated to be 19.4 +/- 6.8 and 21.6 +/- 8.4 for DXA and the Bod Pod, respectively. Although the two methods were highly correlated (0.94), the mean difference of 2.2% was significant (p < 0.01). The amount of difference increased as body fatness increased (p < 0.0001). The results of this study indicate that a difference between methods existed for our sample of men. It is uncertain exactly where the difference lies. Practitioners should be aware that even with the use of technologically sophisticated methods (i.e., Bod Pod, DXA), differences between methods exist and the determination of body composition is at best, an estimation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/25/3/007

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 46

Metadata

Authors
Ball, S. D., & Altena, T. S.
Venue
Physiological Measurement
Published
2004-05-11
Volume
25
Issue
3
Pages
671-678
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W1963988963
Cited by
46
References
8
FWCI
0.95
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.