Longitudinal study of cardiac electrical activity in anesthetized guinea pigs by contactless magnetocardiography
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
Guinea pigs (GPs) are used for preclinical evaluation of electrophysiologic effects of new drugs, because their myocytes have human-like action potentials and ventricular repolarization's (VR) ion currents. This study was aimed to assess the reliability of magnetocardiographic (MCG) mapping for longitudinal studies of GP cardiac electrical activity. Eighteen anesthetized GPs were investigated with an unshielded 36-channel MCG instrumentation, at the age of 5 months (268.1 +/- 19 g). Twelve GPs survived and were restudied when 14 months old (595.6 +/- 90.5 g). RR, PR, QRS, QT(peak), QT(end), JT(peak), JT(end) and T(peak-end) intervals were measured from MCG waveforms. Magnetic field (MF) maps, equivalent current dipole (ECD) parameters and current density imaging were also analyzed. A significant prolongation of the PR (p < 0.05) and QRS (p < 0.001) intervals was found at 14 months. Gender-related differences of VR intervals were not significant. P(peak) and QRS(peak) MFs were similar in all animals, while T(peak) MF varied interindividually at 5 months and showed a rotation in some animals, at 14 months. The ECD strengths, measured at the P(peak), QRS(peak) and T(peak) were stronger (p < 0.01) at the age of 14 months than at 5 months. In contrast to findings in Wistar rats, age-related and gender-related differences of MCG VR parameters were not significant in GPs. Further work is necessary to clarify the variability of VR MF observed in healthy GPs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“demonstrating that unshielded MCG is also feasible, reproducible, and reliable for the non-invasive contactless electrophysiological study of animal models, even with the integration of minimally invasive epicardial monophasic action potential recordings without animals’ sacrifice (Figure 6) (84, 196–200).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [199]
Citations
Cites
Zeng, J., Laurita, K. R., Rosenbaum, D. S., & Rudy, Y. (1995) · Circulation Research · doi:10.1161/01.res.77.1.140 · Cited by 415 · cited 1×
“The guinea pig is an animal breed frequently used for experimental evaluation of cardiac electrophysiology, since its myocytes have an action potential with a well-defined plateau and most of the ion currents, which are present in the human (Zeng et al 1995, Alvarez et al 2005).”
BackgroundHaverkamp, W. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2249 · Cited by 414 · cited 1×
“…requirement for adequate assessment of the most used risk indexes (i.e., QT/QTc interval prolongation and of its dispersion) (de Clerck et al 2002, Haverkamp et al 2000, FDA 2005b), although it has been demonstrated that body surface potential mapping (BSPM) may be more sensitive than standard…”
BackgroundEfimov, I. R., Nikolski, V. P., & Salama, G. (2004) · Circulation Research · doi:10.1161/01.res.0000130529.18016.35 · Cited by 390 · cited 1×
“…in ECG lead I, and that such variability was not univocally correlable with the classification of GPs in subgroups on the basis of MCG VR patterns, a comparative study among MCG mapping, 12-lead ECG and a optical mapping of action potentials would be required (Baker et al 2000, Efimov et al 2004).”
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361 · cited 2×
“The 36-channel MCG mapping system (figure 1(A)) (CardioMag Imaging Inc, Schenectady, NY) features 36 DC-SQUID sensors (Cohen et al 1970) coupled to second-order axial gradiometers with asymmetric baselines (of 55 and 70 mm, respectively), pick-up coil 19 mm and intrinsic sensitivity of 20 fT Hz−1/2…”
BackgroundMethodIn Vivo Cardiac Electrophysiology Studies in the Mouse
Berul, C. I., Aronovitz, M. J., Wang, P. J., & Mendelsohn, M. E. (1996) · Circulation · doi:10.1161/01.cir.94.10.2641 · Cited by 229 · cited 1×
“…2004, Hauser et al 2005), and BSPM has been rarely reported (Aimi et al 1992, Bernadic and Zatlos 1996, Musso et al 1989), because stable positioning of multiple surface electrodes is time consuming and affected by artifacts (Alvarez et al 2005, Berul et al 1996, Danik et al 2002, Liu et al 2003).”
BackgroundBaker, L. C., London, B., Choi, B.-R., Koren, G., & Salama, G. (2000) · Circulation Research · doi:10.1161/01.res.86.4.396 · Cited by 176 · cited 1×
“…in ECG lead I, and that such variability was not univocally correlable with the classification of GPs in subgroups on the basis of MCG VR patterns, a comparative study among MCG mapping, 12-lead ECG and a optical mapping of action potentials would be required (Baker et al 2000, Efimov et al 2004).”
BackgroundClinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174 · cited 2×
“…to electric recordings, MCG mapping, i.e. the recording of the magnetic field (MF) generated by cardiac activation currents (Cohen et al 1970, Fenici et al 2005, Williamson and Kaufman 1981), has several advantages: (1) it is contactless and adequate for the study of conscious and…”
BackgroundSelf-citationVentricular action potentials, ventricular extracellular potentials, and the ECG of guinea pig.
Watanabe, T., Rautaharju, P. M., & McDonald, T. F. (1985) · Circulation Research · doi:10.1161/01.res.57.3.362 · Cited by 119 · cited 3×
“In particular, guinea pigs (GPs) have been proposed to study gender-related differences in drug-induced QT-prolongation and pro-arrhythmia (James et al 2004, James and Hancox 2003, Hamlin et al 2003, Testai et al 2004, Hauser et al 2005), or to model the long-QT syndrome (Watanabe et al 1985).”
BackgroundA Theoretic Model of the T Wave
Harumi, K., Burgess, M. J., & Abildskov, J. A. (1966) · Circulation · doi:10.1161/01.cir.34.4.657 · Cited by 117
Cited by
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Self-citationRecording the heart beat of cattle using a gradiometer system of optically pumped magnetometers
Sutter, J. U., Lewis, O., Robinson, C., McMahon, A., Boyce, R., Bragg, R., Macrae, A., Orton, J., Shah, V., Ingleby, S. J., et al. (2020) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2020.105651 · Cited by 35
Harnessing the Heart’s Magnetic Field for Advanced Diagnostic Techniques
Elfouly, T., & Alouani, A. (2024) · Sensors · doi:10.3390/s24186017 · Cited by 19
“Several studies have highlighted the effectiveness of MCG in detecting ischemic heart disease [81].”
BackgroundDemographic and Methodological Heterogeneity in Electrocardiogram Signals From Guinea Pigs
Haq, K. T., Cooper, B. L., Berk, F., Roberts, A., Swift, L., & Posnack, N. G. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.925042 · Cited by 12
“This finding is consistent with previous studies (Brisinda et al., 2007; Shiotani et al., 2008) that report longer a RR and PR interval, and a slight wider QRS complex in older versus younger animals.”
BackgroundResultInfluentialBrisinda, D., Sorbo, A. R., Venuti, A., & Fenici, R. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/521 · Cited by 6
Self-citationStandardization of magnetocardiography in nonhuman primates
Seki, Y., Muneyuki, K., Kandori, A., Tsukada, K., Terao, K., & Ageyama, N. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/6/007 · Cited by 4
“…has been used in dogs (Cohen et al 1971, Cohen and Kaufman 1975, Leifer et al 1986, Monteiro et al 1987), rabbits (Wu et al 2007), guinea pigs (Brisinda et al 2007), rats (Uchida et al 2000, Brisinda et al 2004, 2006) and mice (Ono et al 2004, Ackermann et al 2007), and has also been used in…”
MethodSmall Animal Biomagnetism Applications
Jensen, K., Bentzen, B. H., & Polzik, E. S. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_3 · Cited by 5
Huneke, R. B. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-380920-9.00022-5 · Cited by 3
Fenici, R., Picerni, M., Fenici, P., & Brisinda, D. (2025) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd12090343 · Cited by 1
“An alternative to BSPM, contactless magnetocardiographic mapping, is feasible in intact rodents and even conscious guinea pigs [17,18].”
Self-citation
Metadata
- Authors
- Brisinda, D., Caristo, M. E., & Fenici, R.
- Affiliations
- Università Cattolica del Sacro Cuore (IT)
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2007-07-06
- Volume
- 28
- Issue
- 8
- Pages
- 773-792
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1995703101
- Semantic Scholar
- 15a3bb27e9eae25719d0abfb52bcc556469870fb
- Cited by
- 9
- References
- 50
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2022: 2 · 2020: 1 · 2012: 1
- FWCI
- 0.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
- Keywords
- magnetocardiography, guinea pig, cardiac electrical activity, ventricular repolarization, equivalent current dipole, current density imaging, age-related changes, gender differences, PR interval, QRS duration, QT interval, T wave, longitudinal study, preclinical drug testing
- MeSH terms
- Aging, Anesthesia, Animals, Electrocardiography, Electrophysiology, Female, Guinea Pigs, Heart, Heart Rate, Longitudinal Studies, Male, Ventricular Function, Magnetocardiography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.