Longitudinal study of cardiac electrical activity in anesthetized guinea pigs by contactless magnetocardiography
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
Guinea pigs (GPs) are used for preclinical evaluation of electrophysiologic effects of new drugs, because their myocytes have human-like action potentials and ventricular repolarization's (VR) ion currents. This study was aimed to assess the reliability of magnetocardiographic (MCG) mapping for longitudinal studies of GP cardiac electrical activity. Eighteen anesthetized GPs were investigated with an unshielded 36-channel MCG instrumentation, at the age of 5 months (268.1 +/- 19 g). Twelve GPs survived and were restudied when 14 months old (595.6 +/- 90.5 g). RR, PR, QRS, QT(peak), QT(end), JT(peak), JT(end) and T(peak-end) intervals were measured from MCG waveforms. Magnetic field (MF) maps, equivalent current dipole (ECD) parameters and current density imaging were also analyzed. A significant prolongation of the PR (p < 0.05) and QRS (p < 0.001) intervals was found at 14 months. Gender-related differences of VR intervals were not significant. P(peak) and QRS(peak) MFs were similar in all animals, while T(peak) MF varied interindividually at 5 months and showed a rotation in some animals, at 14 months. The ECD strengths, measured at the P(peak), QRS(peak) and T(peak) were stronger (p < 0.01) at the age of 14 months than at 5 months. In contrast to findings in Wistar rats, age-related and gender-related differences of MCG VR parameters were not significant in GPs. Further work is necessary to clarify the variability of VR MF observed in healthy GPs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“demonstrating that unshielded MCG is also feasible, reproducible, and reliable for the non-invasive contactless electrophysiological study of animal models, even with the integration of minimally invasive epicardial monophasic action potential recordings without animals’ sacrifice (Figure 6) (84, 196–200).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [199]
Citations
Cites
Zeng, J., Laurita, K. R., Rosenbaum, D. S., & Rudy, Y. (1995) · Circulation Research · doi:10.1161/01.res.77.1.140 · Cited by 415 · cited 1×
“The guinea pig is an animal breed frequently used for experimental evaluation of cardiac electrophysiology, since its myocytes have an action potential with a well-defined plateau and most of the ion currents, which are present in the human (Zeng et al 1995, Alvarez et al 2005).”
BackgroundHaverkamp, W. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2249 · Cited by 414 · cited 1×
“…requirement for adequate assessment of the most used risk indexes (i.e., QT/QTc interval prolongation and of its dispersion) (de Clerck et al 2002, Haverkamp et al 2000, FDA 2005b), although it has been demonstrated that body surface potential mapping (BSPM) may be more sensitive than standard…”
BackgroundEfimov, I. R., Nikolski, V. P., & Salama, G. (2004) · Circulation Research · doi:10.1161/01.res.0000130529.18016.35 · Cited by 390 · cited 1×
“…in ECG lead I, and that such variability was not univocally correlable with the classification of GPs in subgroups on the basis of MCG VR patterns, a comparative study among MCG mapping, 12-lead ECG and a optical mapping of action potentials would be required (Baker et al 2000, Efimov et al 2004).”
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361 · cited 2×
“The 36-channel MCG mapping system (figure 1(A)) (CardioMag Imaging Inc, Schenectady, NY) features 36 DC-SQUID sensors (Cohen et al 1970) coupled to second-order axial gradiometers with asymmetric baselines (of 55 and 70 mm, respectively), pick-up coil 19 mm and intrinsic sensitivity of 20 fT Hz−1/2…”
BackgroundMethodIn Vivo Cardiac Electrophysiology Studies in the Mouse
Berul, C. I., Aronovitz, M. J., Wang, P. J., & Mendelsohn, M. E. (1996) · Circulation · doi:10.1161/01.cir.94.10.2641 · Cited by 229 · cited 1×
“…2004, Hauser et al 2005), and BSPM has been rarely reported (Aimi et al 1992, Bernadic and Zatlos 1996, Musso et al 1989), because stable positioning of multiple surface electrodes is time consuming and affected by artifacts (Alvarez et al 2005, Berul et al 1996, Danik et al 2002, Liu et al 2003).”
BackgroundBaker, L. C., London, B., Choi, B.-R., Koren, G., & Salama, G. (2000) · Circulation Research · doi:10.1161/01.res.86.4.396 · Cited by 176 · cited 1×
“…in ECG lead I, and that such variability was not univocally correlable with the classification of GPs in subgroups on the basis of MCG VR patterns, a comparative study among MCG mapping, 12-lead ECG and a optical mapping of action potentials would be required (Baker et al 2000, Efimov et al 2004).”
BackgroundClinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174 · cited 2×
“…to electric recordings, MCG mapping, i.e. the recording of the magnetic field (MF) generated by cardiac activation currents (Cohen et al 1970, Fenici et al 2005, Williamson and Kaufman 1981), has several advantages: (1) it is contactless and adequate for the study of conscious and…”
BackgroundSelf-citationVentricular action potentials, ventricular extracellular potentials, and the ECG of guinea pig.
Watanabe, T., Rautaharju, P. M., & McDonald, T. F. (1985) · Circulation Research · doi:10.1161/01.res.57.3.362 · Cited by 119 · cited 3×
“In particular, guinea pigs (GPs) have been proposed to study gender-related differences in drug-induced QT-prolongation and pro-arrhythmia (James et al 2004, James and Hancox 2003, Hamlin et al 2003, Testai et al 2004, Hauser et al 2005), or to model the long-QT syndrome (Watanabe et al 1985).”
BackgroundA Theoretic Model of the T Wave
Harumi, K., Burgess, M. J., & Abildskov, J. A. (1966) · Circulation · doi:10.1161/01.cir.34.4.657 · Cited by 117
Magnetocardiography Predicts Coronary Artery Disease in Patients with Acute Chest Pain
Park, J., Hill, P. M., Chung, N., Hugenholtz, P. G., & Jung, F. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.00634.x · Cited by 109 · cited 3×
“…during the JTpeak segment (starting when the MF strength was equal to 1/3 of that at the Tpeak, until the Tpeak), as the following three parameters (Park et al 2005): (a) change of angle between + pole and − pole (in humans abnormal if >45◦); (b) distance between + pole and − pole (in humans…”
BackgroundMethodRecent advances in magnetocardiography
Koch, H. C. (2004) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2004.08.035 · Cited by 108 · cited 2×
“the recording of the magnetic field (MF) generated by cardiac activation currents (Cohen et al 1970, Fenici et al 2005, Williamson and Kaufman 1981), has several advantages: (1) it is contactless and adequate for the study of conscious and unrestrained animals without muscle artifacts (Steinhoff et al 2004); (2) the s…”
BackgroundDanik, S., Cabo, C., Chiello, C., Kang, S., Wit, A. L., & Coromilas, J. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01091.2001 · Cited by 87 · cited 4×
“…2004, Hauser et al 2005), and BSPM has been rarely reported (Aimi et al 1992, Bernadic and Zatlos 1996, Musso et al 1989), because stable positioning of multiple surface electrodes is time consuming and affected by artifacts (Alvarez et al 2005, Berul et al 1996, Danik et al 2002, Liu et al 2003).”
BackgroundResultInfluentialSex-dependent electrocardiographic pattern of cardiac repolarization
Bidoggia, H., Maciel, J. P., Capalozza, N., Mosca, S. M., Blaksley, E. J., Valverde, E. R., Bertran, G. C., Arini, P. D., Biagetti, M. O., & Quinteiro, R. A. (2000) · American Heart Journal · doi:10.1067/mhj.2000.108510 · Cited by 85 · cited 1×
“For comparison, VR intervals were also measured from ECG lead I, using standard criteria (Bidoggia et al 2000).”
MethodLiu, G., Iden, J. B., Kovithavongs, K., Gulamhusein, R., Duff, H. J., & Kavanagh, K. M. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.054064 · Cited by 85 · cited 3×
“…2004, Hauser et al 2005), and BSPM has been rarely reported (Aimi et al 1992, Bernadic and Zatlos 1996, Musso et al 1989), because stable positioning of multiple surface electrodes is time consuming and affected by artifacts (Alvarez et al 2005, Berul et al 1996, Danik et al 2002, Liu et al 2003).”
BackgroundHänninen, H., Takala, P., Mäkijärvi, M., Montonen, J., Korhonen, P., Oikarinen, L., Nenonen, J., Katila, T., & Toivonen, L. (2000) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2000.tb00380.x · Cited by 74 · cited 3×
“Quantitative estimate of MCG parameters of VR according to Hänninen et al (2000) and to Park et al (2005) (table 4) showed a significant gender-related difference for Tpeak α angle and distance dynamics, at the age of 5 months, which was not more appreciable at the age of 14 months.”
MethodHamlin, R. L., Kijtawornrat, A., Keene, B. W., & Hamlin, D. M. (2003) · Toxicological Sciences · doi:10.1093/toxsci/kfg254 · Cited by 74 · cited 4×
“In particular, guinea pigs (GPs) have been proposed to study gender-related differences in drug-induced QT-prolongation and pro-arrhythmia (James et al 2004, James and Hancox 2003, Hamlin et al 2003, Testai et al 2004, Hauser et al 2005), or to model the long-QT syndrome (Watanabe et al 1985).”
BackgroundResultInfluentialPossible sources of new information in the magnetocardiogram
Wikswo, J. P., & Barach, J. P. (1982) · Journal of Theoretical Biology · doi:10.1016/0022-5193(82)90350-2 · Cited by 68 · cited 1×
“This is consistent with the previous hypothesis that MCG mapping can provide new information not appreciable with ECG (Wikswo and Barach 1982), especially if only one or few leads are used (Alvarez et al 2005, Chiello et al 2003, Danik et al 2002, Liu et al 2003, Provan et al 2005, Watanabe et al…”
ResultGender-related differences in ventricular myocyte repolarization in the guinea pig
James, A. F., Arberry, L. A., & Hancox, J. C. (2004) · Basic Research in Cardiology · doi:10.1007/s00395-003-0451-6 · Cited by 67 · cited 4×
“In particular, guinea pigs (GPs) have been proposed to study gender-related differences in drug-induced QT-prolongation and pro-arrhythmia (James et al 2004, James and Hancox 2003, Hamlin et al 2003, Testai et al 2004, Hauser et al 2005), or to model the long-QT syndrome (Watanabe et al 1985).”
BackgroundMethodInfluentialCardiovascular parameters in anaesthetized guinea pigs: A safety pharmacology screening model
Hauser, D. S., Stade, M., Schmidt, A., & Hanauer, G. (2005) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2005.03.003 · Cited by 49 · cited 4×
“In particular, guinea pigs (GPs) have been proposed to study gender-related differences in drug-induced QT-prolongation and pro-arrhythmia (James et al 2004, James and Hancox 2003, Hamlin et al 2003, Testai et al 2004, Hauser et al 2005), or to model the long-QT syndrome (Watanabe et al 1985).”
BackgroundInfluentialNon-invasive imaging of arrhythmogenic left-ventricular myocardium after infarction
Leder, U., Haueisen, J., Huck, M., & Nowak, H. (1998) · The Lancet · doi:10.1016/s0140-6736(98)00082-8 · Cited by 48 · cited 2×
“The MNE method (Leder et al 1998, Nenonen et al 2001) provided reproducible current density imaging (CDI) at the epicardial surface.”
MethodSpatial Distribution of QT Intervals: An Alternative Approach to QT Dispersion
VAN LEEUWEN, P., HAILER, B., & WEHR, M. (1996) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1996.tb03248.x · Cited by 45
Testai, L., Calderone, V., Salvadori, A., Breschi, M. C., Nieri, P., & Martinotti, E. (2004) · Journal of Applied Toxicology · doi:10.1002/jat.975 · Cited by 42 · cited 4×
“In particular, guinea pigs (GPs) have been proposed to study gender-related differences in drug-induced QT-prolongation and pro-arrhythmia (James et al 2004, James and Hancox 2003, Hamlin et al 2003, Testai et al 2004, Hauser et al 2005), or to model the long-QT syndrome (Watanabe et al 1985).”
BackgroundResultInfluentialNakai, K., Izumoto, H., Kawazoe, K., Tsuboi, J., Fukuhiro, Y., Oka, T., Yoshioka, K., Shozushima, M., Itoh, M., Suwabe, A., et al. (2005) · International journal of cardiac imaging · doi:10.1007/s10554-005-9019-x · Cited by 34
FENICI, R., NENONEN, J., PESOLA, K., KORHONEN, P., LÖTJÖNEN, J., MÄKIJÄRVI, M., TOIVONEN, L., POUTANEN, V., KETO, P., & KATILA, T. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00602.x · Cited by 29 · cited 3×
“A systematic quantitative assessment of source localization accuracy (Fenici et al 1999) in the guinea pig will be the matter of a separate paper.”
BackgroundMethodSelf-citationBrisinda, D., Meloni, A. M., & Fenici, R. (2003) · Lecture notes in computer science · doi:10.1007/3-540-44883-7_13 · Cited by 28 · cited 3×
“…(Cohen et al 1970) coupled to second-order axial gradiometers with asymmetric baselines (of 55 and 70 mm, respectively), pick-up coil 19 mm and intrinsic sensitivity of 20 fT Hz−1/2 in the frequency range of interest for clinical MCG mapping (DC to 100 Hz) (Brisinda et al 2003, 2004a, 2006a).”
BackgroundMethodSelf-citationNenonen, J., Pesola, K., H[auml ]nninen, H., Lauerma, K., Takala, P., M[auml ]kel[auml ], T., M[auml ]kij[auml ]rvi, M., Knuuti, J., Toivonen, L., & Katila, T. (2001) · Journal of Electrocardiology · doi:10.1054/jelc.2001.28824 · Cited by 27 · cited 4×
“…(MFD) during the whole cardiac cycle and a quantitative estimate of several other MCG parameters including the distribution of cardiac currents (Nenonen et al 2001, Fenici et al 2006), which were useful to explain the lack of concordance between the QRS complex and the T wave observed in the…”
BackgroundMethodInfluentialCzapski, P., Ramon, C., Huntsman, L. L., Bardy, G. H., & Kim, Y. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.477705 · Cited by 25 · cited 1×
“…activation currents (or ‘primary sources’) whereas, in a first approximation, the contribution of the volume currents (or ‘secondary sources’) can be considered less significant (Williamson and Kaufman 1981), although not neglectable at the light of simulation studies (Czapski et al 1996a, 1996b).”
BackgroundElectrophysiologic Effects of Nicorandil on the Guinea Pig Long QT1 Syndrome Model
Yang, Z., SHI, G., LI, C., Wang, H., Liu, K., & Liu, Y. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03632.x · Cited by 24 · cited 1×
“…post-mortem simultaneous recording of extracellular potential and action potentials from ventricular strips excised from the same animal (Zhifang Yang et al 2004), most often clinical assessment of drug-induced cardiotoxic risk is based on non-invasive measurement of ECG parameters of…”
BackgroundAntimony‐induced cardiomyopathy in guinea‐pig and protection by L ‐carnitine
Alvarez, M., Malécot, C. O., Gannier, F. E., & Lignon, J. M. (2004) · British Journal of Pharmacology · doi:10.1038/sj.bjp.0706030 · Cited by 23 · cited 3×
“…2004, Hauser et al 2005), and BSPM has been rarely reported (Aimi et al 1992, Bernadic and Zatlos 1996, Musso et al 1989), because stable positioning of multiple surface electrodes is time consuming and affected by artifacts (Alvarez et al 2005, Berul et al 1996, Danik et al 2002, Liu et al 2003).”
BackgroundBrisinda, D., Caristo, M. E., & Fenici, R. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01048.2005 · Cited by 23 · cited 9×
“…analysis of the dynamic evolution of MF maps (constructed every ms) was helpful to improve the accuracy of QRS and JT intervals timing, because each instant of interest was clearly identified by an evident change in polarity and/or morphology of the maps (figure 2) (Brisinda et al 2004b, 2006a).”
BackgroundMethodResultInfluentialSelf-citationProvan, G., Stanton, A., Sutton, A., Rankin-Burkart, A., & Laycock, S. K. (2005) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2005.03.006 · Cited by 21 · cited 3×
“…is consistent with the previous hypothesis that MCG mapping can provide new information not appreciable with ECG (Wikswo and Barach 1982), especially if only one or few leads are used (Alvarez et al 2005, Chiello et al 2003, Danik et al 2002, Liu et al 2003, Provan et al 2005, Watanabe et al 1985).”
BackgroundMethodMeloni, A. M., Fenici, R., & Brisinda, D. (2004) · Basic Research in Cardiology · doi:10.1007/s00395-003-0453-4 · Cited by 21 · cited 6×
“…analysis of the dynamic evolution of MF maps (constructed every ms) was helpful to improve the accuracy of QRS and JT intervals timing, because each instant of interest was clearly identified by an evident change in polarity and/or morphology of the maps (figure 2) (Brisinda et al 2004b, 2006a).”
BackgroundMethodInfluentialSelf-citationSteinhoff, U., Knappe-Grüneberg, S., Schnabel, A., Trahms, L., Smith, F. E., Langley, P., Murray, A., & Koch, H. C. (2004) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2004.08.055 · Cited by 20 · cited 7×
“…1981), has several advantages: (1) it is contactless and adequate for the study of conscious and unrestrained animals without muscle artifacts (Steinhoff et al 2004); (2) the sensors geometry is fixed, which minimizes errors in localization of intracardiac sources (Koch 2004) and of VR…”
BackgroundMethodInfluentialMultichannel mapping of fetal magnetocardiogram in an unshielded hospital setting
Brisinda, D., Comani, S., Meloni, A. M., Alleva, G., Mantini, D., & Fenici, R. (2005) · Prenatal Diagnosis · doi:10.1002/pd.1160 · Cited by 18 · cited 1×
“…shielding (Steinhoff et al 2004, Wiekhorst et al 2006) more advanced signal processing methods, such as the independent-component analysis (Lee et al 2004), could be used in animal studies, having been successful in improving the detection of the fetal magnetocardiogram (Brisinda et al 2005).”
MethodSelf-citationJames, A., & Hancox, J. C. (2002) · Cardiovascular Research · doi:10.1016/s0008-6363(02)00740-x · Cited by 16 · cited 1×
“In particular, guinea pigs (GPs) have been proposed to study gender-related differences in drug-induced QT-prolongation and pro-arrhythmia (James et al 2004, James and Hancox 2003, Hamlin et al 2003, Testai et al 2004, Hauser et al 2005), or to model the long-QT syndrome (Watanabe et al 1985).”
BackgroundUchida, S., Iramina, K., Goto, K., & Ueno, S. (2000) · Journal of Applied Physics · doi:10.1063/1.372655 · Cited by 15 · cited 2×
“As said above, CDI provided reproducible imaging of VR current flowing direction and localization at epicardial level (figure 9), which might be useful for more accurate assessment of VR abnormalities and arrhythmogenic markers in experimental models of cardiomyopathy (Uchida et al 2000).”
BackgroundElectrophysiological consequences of humanI Ks channel expression in adult murine heart
Chiello, C., Cabo, C., Coromilas, J., Kurokawa, J., Kass, R. S., & Wit, A. L. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00661.2002 · Cited by 15
AIBA, T., INAGAKI, M., SHIMIZU, W., MATSUO, K., TAGUCHI, A., SUYAMA, K., KURITA, T., AIHARA, N., SUNAGAWA, K., & KAMAKURA, S. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb00168.x · Cited by 15 · cited 1×
“…and of its dispersion) (de Clerck et al 2002, Haverkamp et al 2000, FDA 2005b), although it has been demonstrated that body surface potential mapping (BSPM) may be more sensitive than standard ECG for the evaluation of repolarization inhomogeneity (Aiba et al 2000, Havranek et al 2004).”
BackgroundOnline Heart Model Creation for Magnetocardiographic Measurements
Veisterä, H., Fenici, R., & Lötjönen, J. M. P. (2004) · Cited by 10
Self-citationCzapski, P., Ramon, C., Huntsman, L. L., Bardy, G. H., & Kim, Y. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/8/001 · Cited by 10 · cited 1×
“…activation currents (or ‘primary sources’) whereas, in a first approximation, the contribution of the volume currents (or ‘secondary sources’) can be considered less significant (Williamson and Kaufman 1981), although not neglectable at the light of simulation studies (Czapski et al 1996a, 1996b).”
BackgroundCardioelectrical field in experimental cardiomegaly in rats.
Bernadic, M., & Zlatoš, L. (1996) · PubMed · Cited by 8
Fenici, R., & Fenici, P. (1999) · Cited by 6
Self-citationUnshielded Multichannel Magnetocardiographic Mapping of Small Animals.
Brisinda, D., Fenici, R., Meloni, A. M., & Fenici, P. (2004) · Cited by 6
Self-citationBody surface maps in chronically instrumented rats
Musso, E., Stilli, D., Olivetti, G., Ricci, R., & Lagrasta, C. A. M. (1989) · Journal of Electrocardiology · doi:10.1016/0022-0736(89)90059-9 · Cited by 5 · cited 3×
“Whilst BSPM is difficult to perform routinely in small animals (Bernadic and Zatlos 1996, Musso et al 1989) multi-site magnetocardiographic (MCG) recordings can be an alternative to simplify non-invasive cardiac electrophysiologic mapping.”
BackgroundMethodResultHavránek, Š., Micek, M., Paclt, I., Slavíček, J., Kittnar, O., Dohnalova, A., Brizman, E., Hála, P., Kittzlerová, E., & Pišvejcová, K. (2004) · PubMed · Cited by 5
Lee, H. N., Park, T. S., Lee, S. Y., & Huh, Y. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02350995 · Cited by 4 · cited 1×
“…shielding (Steinhoff et al 2004, Wiekhorst et al 2006) more advanced signal processing methods, such as the independent-component analysis (Lee et al 2004), could be used in animal studies, having been successful in improving the detection of the fetal magnetocardiogram (Brisinda et al…”
MethodBrisinda, D., Meloni, A. M., & Fenici, R. (2004) · PubMed · Cited by 3
Self-citationFenici, R., & Brisinda, D. (2007) · International Congress Series · doi:10.1016/j.ics.2006.12.042 · Cited by 3
Self-citationBrisinda, D., Caristo, M. E., & Fenici, R. (2007) · International Congress Series · doi:10.1016/j.ics.2006.12.047 · Cited by 3
Self-citation
Cited by
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Self-citationRecording the heart beat of cattle using a gradiometer system of optically pumped magnetometers
Sutter, J. U., Lewis, O., Robinson, C., McMahon, A., Boyce, R., Bragg, R., Macrae, A., Orton, J., Shah, V., Ingleby, S. J., et al. (2020) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2020.105651 · Cited by 35
Harnessing the Heart’s Magnetic Field for Advanced Diagnostic Techniques
Elfouly, T., & Alouani, A. (2024) · Sensors · doi:10.3390/s24186017 · Cited by 19
“Several studies have highlighted the effectiveness of MCG in detecting ischemic heart disease [81].”
BackgroundDemographic and Methodological Heterogeneity in Electrocardiogram Signals From Guinea Pigs
Haq, K. T., Cooper, B. L., Berk, F., Roberts, A., Swift, L., & Posnack, N. G. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.925042 · Cited by 12
“This finding is consistent with previous studies (Brisinda et al., 2007; Shiotani et al., 2008) that report longer a RR and PR interval, and a slight wider QRS complex in older versus younger animals.”
BackgroundResultInfluentialBrisinda, D., Sorbo, A. R., Venuti, A., & Fenici, R. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/521 · Cited by 6
Self-citation
Metadata
- Authors
- Brisinda, D., Caristo, M. E., & Fenici, R.
- Affiliations
- Università Cattolica del Sacro Cuore (IT)
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2007-07-06
- Volume
- 28
- Issue
- 8
- Pages
- 773-792
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1995703101
- Cited by
- 9
- References
- 50
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2022: 2 · 2020: 1 · 2012: 1
- FWCI
- 0.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
- Keywords
- magnetocardiography, guinea pig, cardiac electrical activity, ventricular repolarization, equivalent current dipole, current density imaging, age-related changes, gender differences, PR interval, QRS duration, QT interval, T wave, longitudinal study, preclinical drug testing
- MeSH terms
- Aging, Anesthesia, Animals, Electrocardiography, Electrophysiology, Female, Guinea Pigs, Heart, Heart Rate, Longitudinal Studies, Male, Ventricular Function, Magnetocardiography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.