Abstract
Patient biopotentials are usually measured with conventional disposable Ag/AgCl electrodes. These electrodes provide excellent signal quality but are irritating for long-term use. Skin preparation is usually required prior to the application of electrodes such as shaving and cleansing with alcohol. To overcome these difficulties, researchers and caregivers seek alternative electrodes that would be acceptable in clinical and research environments. Dry electrodes that operate without gel, adhesive or even skin preparation have been studied for many decades. They are used in research applications, but they have yet to achieve acceptance for medical use. So far, a complete comparison and evaluation of dry electrodes is not well described in the literature. This work compares dry electrodes for biomedical use and physiological research, and reviews some novel systems developed for cardiac monitoring. Lastly, the paper provides suggestions to develop a dry-electrode-based system for mobile and long-term cardiac monitoring applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
Self-citationBioimpedance and Bioelectricity Basics
(2015) · Elsevier eBooks · doi:10.1016/c2012-0-06951-7 · Cited by 1,175
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
A Wearable Health Care System Based on Knitted Integrated Sensors
Paradiso, R., Loriga, G., & Taccini, N. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854512 · Cited by 729
A direct comparison of wet, dry and insulating bioelectric recording electrodes
Searle, A., & Kirkup, L. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/307 · Cited by 725
Encyclopedia of Medical Devices and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/0471732877 · Cited by 481
Bioimpedance and Bioelectricity Basics
(2008) · Elsevier eBooks · doi:10.1016/b978-0-12-374004-5.x0001-3 · Cited by 462
Electrical properties of the epidermal stratum corneum
Yamamoto, T., & Yamamoto, Y. (1976) · Medical & Biological Engineering · doi:10.1007/bf02478741 · Cited by 436
60-Hz Interference in Electrocardiography
Huhta, J. C., & Webster, J. G. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324169 · Cited by 412
Self-citationFlexible polymeric dry electrodes for the long-term monitoring of ECG
Baek, J.-Y., An, J.-H., Choi, J.-M., Park, K.-S., & Lee, S.-H. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2007.11.019 · Cited by 340
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Nanomaterial-Enabled Wearable Sensors for Healthcare
Yao, S., Swetha, P., & Zhu, Y. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700889 · Cited by 576
Memristor-based neural networks
Thomas, A. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/9/093001 · Cited by 471
Mairesse, G. H., Moran, P., Van Gelder, I. C., Elsner, C., Rosenqvist, M., Mant, J., Banerjee, A., Gorenek, B., Brachmann, J., Varma, N., et al. (2017) · EP Europace · doi:10.1093/europace/eux177 · Cited by 250
“5 min per episodes.(117,118) Better compliance was observed from the patients compared to conventional adhesive skin-contact electrodes.”
BackgroundSoft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording
Chen, Y.-H., De Beeck, M., Vanderheyden, L., Carrette, E., Mihajlović, V., Vanstreels, K., Grundlehner, B., Gadeyne, S., Boon, P., & Van Hoof, C. (2014) · Sensors · doi:10.3390/s141223758 · Cited by 238
“To avoid these drawbacks of wet electrodes, various types of dry electrodes have been introduced, as discussed in various publications [11–22].”
Multifunctional Smart Skin Adhesive Patches for Advanced Health Care
Hwang, I., Kim, H. N., Seong, M., Lee, S., Kang, M., Yi, H., Bae, W. G., Kwak, M. K., & Jeong, H. E. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201800275 · Cited by 227
Dry Electrodes for Human Bioelectrical Signal Monitoring
Fu, Y., Zhao, J., Dong, Y., & Wang, X. (2020) · Sensors · doi:10.3390/s20133651 · Cited by 225
“It can be self-sufficient because of its extremely low power consumption [9].”
BackgroundCalcium‐Modified Silk as a Biocompatible and Strong Adhesive for Epidermal Electronics
Seo, J., Kim, H., Kim, K., Choi, S. Q., & Lee, H. J. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201800802 · Cited by 221
Nawrocki, R. A., Jin, H., Lee, S., Yokota, T., Sekino, M., & Someya, T. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201803279 · Cited by 206
Organic Electrochemical Transistors for In Vivo Bioelectronics
Nawaz, A., Liu, Q., Leong, W. L., Fairfull‐Smith, K. E., & Sonar, P. (2021) · Advanced Materials · doi:10.1002/adma.202101874 · Cited by 203
Mitchell, M. J., & King, M. R. (2013) · New Journal of Physics · doi:10.1088/1367-2630/15/1/015008 · Cited by 196
Development of printed and flexible dry ECG electrodes
Chlaihawi, A. A., Narakathu, B. B., Emamian, S., Bazuin, B. J., & Atashbar, M. Z. (2018) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2018.05.001 · Cited by 193
Capacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review
Sun, Y., & Yu, X. B. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2519392 · Cited by 174
Nanomaterial-Enabled Dry Electrodes for Electrophysiological Sensing: A Review
Yao, S., & Zhu, Y. (2016) · JOM · doi:10.1007/s11837-016-1818-0 · Cited by 166
Ambulatory cardiac bio-signals: From mirage to clinical reality through a decade of progress
Periyaswamy, T., & Balasubramanian, M. (2019) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2019.07.007 · Cited by 14
Metadata
- Authors
- Meziane, N., Webster, J. G., Attari, M., & Nimunkar, A. J.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2013-08-23
- Volume
- 34
- Issue
- 9
- Pages
- R47-R69
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1993129711
- Cited by
- 288
- References
- 58
- FWCI
- 9.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.