Machine learning for activity recognition: hip versus wrist data
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
PROBLEM ADDRESSED: Wrist-worn accelerometers are associated with greater compliance. However, validated algorithms for predicting activity type from wrist-worn accelerometer data are lacking. This study compared the activity recognition rates of an activity classifier trained on acceleration signal collected on the wrist and hip. METHODOLOGY: 52 children and adolescents (mean age 13.7 ± 3.1 year) completed 12 activity trials that were categorized into 7 activity classes: lying down, sitting, standing, walking, running, basketball, and dancing. During each trial, participants wore an ActiGraph GT3X+ tri-axial accelerometer on the right hip and the non-dominant wrist. Features were extracted from 10-s windows and inputted into a regularized logistic regression model using R (Glmnet + L1). RESULTS: Classification accuracy for the hip and wrist was 91.0% ± 3.1% and 88.4% ± 3.0%, respectively. The hip model exhibited excellent classification accuracy for sitting (91.3%), standing (95.8%), walking (95.8%), and running (96.8%); acceptable classification accuracy for lying down (88.3%) and basketball (81.9%); and modest accuracy for dance (64.1%). The wrist model exhibited excellent classification accuracy for sitting (93.0%), standing (91.7%), and walking (95.8%); acceptable classification accuracy for basketball (86.0%); and modest accuracy for running (78.8%), lying down (74.6%) and dance (69.4%).Potential Impact: Both the hip and wrist algorithms achieved acceptable classification accuracy, allowing researchers to use either placement for activity recognition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regularization Paths for Generalized Linear Models via Coordinate Descent
Friedman, J., Hastie, T., & Tibshirani, R. (2010) · Journal of Statistical Software · doi:10.18637/jss.v033.i01 · Cited by 19,927
Too Much Sitting: The Population Health Science of Sedentary Behavior
Owen, N., Healy, G. N., Matthews, C. E., & Dunstan, D. W. (2010) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e3181e373a2 · Cited by 2,202
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033 · cited 1×
“To date, the majority of studies have employed a hip or waist placement because it allows detection of the body’s acceleration and de-accel-eration during locomotion (i.e. walking and running) (Trost et al 2005).”
BackgroundSelf-citationComparison of Accelerometer Cut Points for Predicting Activity Intensity in Youth
TROST, S. G., LOPRINZI, P. D., MOORE, R., & PFEIFFER, K. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318206476e · Cited by 1,360
Self-citationStrath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029 · cited 1×
“…measurement of physical activity is essential for performing physical activity surveillance, understanding the relationship between physical activity dose and health outcomes, and evaluating the effectiveness of intervention strategies to increase physical activity (Strath et al 2013, Trost 2007).”
BackgroundAssessment of physical activity in youth
Corder, K., Ekelund, U., Steele, R. M., Wareham, N. J., & Brage, S. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00094.2008 · Cited by 581 · cited 1×
“Due to their unobtrusive size, robustness, and relatively low cost, accelerometer-based motion sensors have become one of the most commonly used methods for assessing physical activity and sedentary behaviour in free-living participants (Corder et al 2008, Trost 2007).”
MethodEstimation of energy expenditure using CSA accelerometers at hip and wrist sites
SWARTZ, A. M., STRATH, S. J., BASSETT, D. R., O???BRIEN, W. L., KING, G. A., & AINSWORTH, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00003 · Cited by 513
State of the Art Reviews: Measurement of Physical Activity in Children and Adolescents
Trost, S. G. (2007) · American Journal of Lifestyle Medicine · doi:10.1177/1559827607301686 · Cited by 404 · cited 2×
“…measurement of physical activity is essential for performing physical activity surveillance, understanding the relationship between physical activity dose and health outcomes, and evaluating the effectiveness of intervention strategies to increase physical activity (Strath et al 2013, Trost 2007).”
BackgroundMethodSelf-citationEstimating Activity and Sedentary Behavior from an Accelerometer on the Hip or Wrist
ROSENBERGER, M. E., HASKELL, W. L., ALBINALI, F., MOTA, S., NAWYN, J., & INTILLE, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827f0d9c · Cited by 237
Lyden, K., Kozey, S. L., Staudenmeyer, J. W., & Freedson, P. S. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1639-8 · Cited by 222
A Method to Estimate Free-Living Active and Sedentary Behavior from an Accelerometer
LYDEN, K., KEADLE, S. K., STAUDENMAYER, J., & FREEDSON, P. S. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182a42a2d · Cited by 170
Predicting Energy Expenditure of Physical Activity Using Hip- and Wrist-Worn Accelerometers
Chen, K. Y., Acra, S. A., Majchrzak, K., Donahue, C. L., Baker, L., Clemens, L., Sun, M., & Buchowski, M. S. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322641088 · Cited by 116 · cited 1×
“…respect to compliance, calibration studies using regression-based or cut-point approaches show accelerometer data from the hip to provide more accurate estimates of energy expenditure than that collected at the wrist (Chen et al 2003, Rosenberger et al 2013, Swartz et al 2000, Welch et al 2013).”
MethodComment on “Estimating Activity and Sedentary Behavior from an Accelerometer on the Hip and Wrist”
FREEDSON, P. S., & JOHN, D. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827f024d · Cited by 90 · cited 1×
“In the most recent NHANES physical activity monitoring study (2011–2012) compliance with a wrist-worn accelerometer has been 70%–80%, with a median wear time of 21–22 h per day (Freedson and John 2013).”
BackgroundComputational Methods for Estimating Energy Expenditure in Human Physical Activities
LIU, S., GAO, R. X., & FREEDSON, P. S. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31825e825a · Cited by 78
WELCH, W. A., BASSETT, D. R., THOMPSON, D. L., FREEDSON, P. S., STAUDENMAYER, J. W., JOHN, D., STEEVES, J. A., CONGER, S. A., CEASER, T., HOWE, C. A., et al. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182965249 · Cited by 66 · cited 1×
“…respect to compliance, calibration studies using regression-based or cut-point approaches show accelerometer data from the hip to provide more accurate estimates of energy expenditure than that collected at the wrist (Chen et al 2003, Rosenberger et al 2013, Swartz et al 2000, Welch et al 2013).”
MethodPatterns of Noncompliance in Adolescent Field-Based Accelerometer Research
Belton, S., O’Brien, W., Wickel, E. E., & Issartel, J. (2013) · Journal of Physical Activity and Health · doi:10.1123/jpah.10.8.1181 · Cited by 53
Ambulatory monitoring and sedentary behaviour: a population-health perspective
Owen, N. G. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/11/1801 · Cited by 45 · cited 2×
“35 ( 2014 ) 2183 via accelerometry has become a research topic of considerable importance (Owen 2012).”
BackgroundRuch, N., Joss, F., Jimmy, G., Melzer, K., Hänggi, J. M., & Mäder, U. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01443.2012 · Cited by 28 · cited 1×
“We note that the prediction of energy expenditure may be more accurate when the activity type is recognized first (Ruch et al 2013), and this approach should be explored further in future experiments involving wrist worn monitors.”
Cited by
Poitras, V. J., Gray, C. E., Borghese, M. M., Carson, V., Chaput, J.-P., Janssen, I., Katzmarzyk, P. T., Pate, R. R., Connor Gorber, S., Kho, M. E., et al. (2016) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2015-0663 · Cited by 2,217
“2011) or adopt new analytic techniques such as pattern recognition (Freedson et al. 2012; Trost et al. 2014), and use shorter sampling intervals (Sanders et al.”
BackgroundComplex Human Activity Recognition Using Smartphone and Wrist-Worn Motion Sensors
Shoaib, M., Bosch, S., Incel, O., Scholten, H., & Havinga, P. (2016) · Sensors · doi:10.3390/s16040426 · Cited by 423
A Deep Learning Approach to Human Activity Recognition Based on Single Accelerometer
Chen, Y., & Xue, Y. (2015) · 2015 IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2015.263 · Cited by 378
Precision nutrition: A systematic literature review
Kirk, D., Catal, C., & Tekinerdogan, B. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104365 · Cited by 238
“Similarly, Trost et al. [91] compared wrist and hip data in children and adolescents across 12 activities [91].”
BackgroundBakrania, K., Yates, T., Rowlands, A. V., Esliger, D. W., Bunnewell, S., Sanders, J., Davies, M., Khunti, K., & Edwardson, C. L. (2016) · PLOS ONE · doi:10.1371/journal.pone.0164045 · Cited by 165
“However, these findings are as expected since the magnitude of the acceleration signals is very similar when lying/sitting or standing still, and in order to accurately discriminate between postures, more features of the acceleration signal (such as the angles between the individual orthogonal axes of acceleration fro…”
Background
Metadata
- Authors
- Trost, S. G., Zheng, Y., & Wong, W.-K.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2014-10-23
- Volume
- 35
- Issue
- 11
- Pages
- 2183-2189
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1599865649
- Cited by
- 181
- References
- 18
- FWCI
- 13.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.