CoChat

Intensity Thresholds on Raw Acceleration Data: Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) Approaches

Open access
Bakrania, Kishan, Yates, Thomas, Rowlands, Alex V., Esliger, Dale W., Bunnewell, Sarah, Sanders, James, Davies, Melanie, Khunti, Kamlesh, Edwardson, Charlotte L. · 2016 · PLOS ONE
Cited by 165

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: (1) To develop and internally-validate Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) thresholds for separating sedentary behaviours from common light-intensity physical activities using raw acceleration data collected from both hip- and wrist-worn tri-axial accelerometers; and (2) to compare and evaluate the performances between the ENMO and MAD metrics. METHODS: Thirty-three adults [mean age (standard deviation (SD)) = 27.4 (5.9) years; mean BMI (SD) = 23.9 (3.7) kg/m2; 20 females (60.6%)] wore four accelerometers; an ActiGraph GT3X+ and a GENEActiv on the right hip; and an ActiGraph GT3X+ and a GENEActiv on the non-dominant wrist. Under laboratory-conditions, participants performed 16 different activities (11 sedentary behaviours and 5 light-intensity physical activities) for 5 minutes each. ENMO and MAD were computed from the raw acceleration data, and logistic regression and receiver-operating-characteristic (ROC) analyses were implemented to derive thresholds for activity discrimination. Areas under ROC curves (AUROC) were calculated to summarise performances and thresholds were assessed via executing leave-one-out-cross-validations. RESULTS: For both hip and wrist monitor placements, in comparison to the ActiGraph GT3X+ monitors, the ENMO and MAD values derived from the GENEActiv devices were observed to be slightly higher, particularly for the lower-intensity activities. Monitor-specific hip and wrist ENMO and MAD thresholds showed excellent ability for separating sedentary behaviours from motion-based light-intensity physical activities (in general, AUROCs >0.95), with validation indicating robustness. However, poor classification was experienced when attempting to isolate standing still from sedentary behaviours (in general, AUROCs <0.65). The ENMO and MAD metrics tended to perform similarly across activities and accelerometer brands. CONCLUSIONS: Researchers can utilise these robust monitor-specific hip and wrist ENMO and MAD thresholds, in order to accurately separate sedentary behaviours from common motion-based light-intensity physical activities. However, caution should be taken if isolating sedentary behaviours from standing is of particular interest.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0164045

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 165

Metadata

Authors
Bakrania, K., Yates, T., Rowlands, A. V., Esliger, D. W., Bunnewell, S., Sanders, J., Davies, M., Khunti, K., & Edwardson, C. L.
Venue
PLOS ONE
Published
2016-10-05
Volume
11
Issue
10
Pages
e0164045
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2528042246
Cited by
165
References
14
FWCI
5.93
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intensity Thresholds on Raw Acceleration Data: Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) Approaches. https://app.cochat.ai/papers/10.1371/journal.pone.0164045
The paper
Bakrania, K., Yates, T., Rowlands, A. V., Esliger, D. W., Bunnewell, S., Sanders, J., Davies, M., Khunti, K., & Edwardson, C. L. (2016). Intensity Thresholds on Raw Acceleration Data: Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) Approaches. PLOS ONE. https://doi.org/10.1371/journal.pone.0164045

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.