The DOI matches its Crossref record; 15 of the 16 references it cites were found in a registry or an index.
Improved motion robustness of remote-PPG by using the blood volume pulse signature
Open accessAbstract
Remote photoplethysmography (rPPG) enables contact-free monitoring of the blood volume pulse using a color camera. Essentially, it detects the minute optical absorption changes caused by blood volume variations in the skin. In this paper, we show that the different absorption spectra of arterial blood and bloodless skin cause the variations to occur along a very specific vector in a normalized RGB-space. The exact vector can be determined for a given light spectrum and for given transfer characteristics of the optical filters in the camera. We show that this 'signature' can be used to design an rPPG algorithm with a much better motion robustness than the recent methods based on blind source separation, and even better than the chrominance-based methods we published earlier. Using six videos recorded in a gym, with four subjects exercising on a range of fitness devices, we confirm the superior motion robustness of our newly proposed rPPG methods. A simple peak detector in the frequency domain returns the correct pulse-rate for 68% of total measurements compared to 60% for the best previous method, while the SNR of the pulse-signal improves from - 5 dB to - 4 dB. For a large population of 117 stationary subjects we prove that the accuracy is comparable to the best previous method, although the SNR of the pulse-signal drops from + 8.4 dB to + 7.6 dB. We expect the improved motion robustness to significantly widen the application scope of the rPPG-technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although during exercise, the main potential errors are due to motion artifact, which complicates the use of the pulse oximeter and the accurate interpretation of the data [29,30,31]”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,728
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M., McDuff, D., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,652
Robust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378
Self-citationDetecting Pulse from Head Motions in Video
Balakrishnan, G., Durand, F., & Guttag, J. V. (2013) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2013.440 · Cited by 572
Contact-Free Measurement of Cardiac Pulse Based on the Analysis of Thermal Imagery
Garbey, M., Sun, N., Merla, A., & Pavlidis, I. T. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891930 · Cited by 428
Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity
Lewandowska, M., Rumiński, J., Kocejko, T., & Nowak, J. (2011) · Cited by 420
Heart rate measurement based on a time-lapse image.
Takano, C., & Ohta, Y. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.09.006 · Cited by 345
Passive blood plasma separation at the microscale: a review of design principles and microdevices
Tripathi, S., Kumar, Y. V. B. V., Prabhakar, A., Joshi, S. S., & Agrawal, A. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/8/083001 · Cited by 223
Photoelectric Plethysmography of the Fingers and Toes in Man
Hertzman, A. B. (1937) · Experimental Biology and Medicine · doi:10.3181/00379727-37-9630 · Cited by 221
Research works printed but not linked: 2
- Lewandowska M, 2011, Proc. FedCSIS, 18–21, 405
- Glass K A, 2004, Proc. 5th Int. Conf. ICA
Cited by
Sorted by citations
Items 101–200 of 491
Non-Contact Heart Rate Estimation via Adaptive RGB/NIR Signal Fusion
Kurihara, K., Sugimura, D., & Hamamoto, T. (2021) · IEEE Transactions on Image Processing · doi:10.1109/tip.2021.3094739 · Cited by 33
Long Short-Term Memory Deep-Filter in Remote Photoplethysmography
Botina-Monsalve, D., Benezeth, Y., Macwan, R., Pierrart, P., Parra, F., Nakamura, K., Gómez, R., & Mitéran, J. (2020) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw50498.2020.00161 · Cited by 33
A LSTM-Based Realtime Signal Quality Assessment for Photoplethysmogram and Remote Photoplethysmogram
Gao, H., Wu, X., Shi, C., Gao, Q., & Geng, J. (2021) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw53098.2021.00424 · Cited by 31
Evaluation of Remote Photoplethysmography Measurement Conditions toward Telemedicine Applications
Tohma, A., Nishikawa, M., Hashimoto, T., Yamazaki, Y., & Sun, G. (2021) · Sensors · doi:10.3390/s21248357 · Cited by 31
Haugg, F., Elgendi, M., & Menon, C. (2023) · Bioengineering · doi:10.3390/bioengineering10020243 · Cited by 31
Attacks on Heartbeat-Based Security Using Remote Photoplethysmography
Seepers, R. M., Wang, W., de Haan, G., Sourdis, I., & Strydis, C. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2691282 · Cited by 31
Self-citationTrusted emotion recognition based on multiple signals captured from video
Zhang, J., Zheng, K., Mazhar, S., Fu, X., & Kong, J. (2023) · Expert Systems with Applications · doi:10.1016/j.eswa.2023.120948 · Cited by 29
Chen, S., Ho, S. K., Chin, J. W., Luo, K. H., Chan, T. T., So, R. H. Y., & Wong, K. L. (2023) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw59228.2023.00647 · Cited by 30
Al‐Naji, A., & Chahl, J. (2018) · IEEE Access · doi:10.1109/access.2018.2811392 · Cited by 29
Fitness heart rate measurement using face videos
Zhu, Q., Wong, C.-W., Fu, C., & Wu, M. H. (2017) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2017.8296632 · Cited by 28
Robust heart-rate estimation from facial videos using Project_ICA
Qi, L., Yu, H., Xu, L., Mpanda, R. S., & Greenwald, S. E. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab2c9f · Cited by 28
Non-Contact Heart Rate Measurement From Facial Video Data Using a 2D-VMD Scheme
Das, M., Choudhary, T., Bhuyan, M. K., & Sharma, L. N. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3169963 · Cited by 28
Assessment of blind source separation techniques for video-based cardiac pulse extraction
Wedekind, D., Trumpp, A., Gaetjen, F., Rasche, S., Matschke, K., Malberg, H., & Zaunseder, S. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.3.035002 · Cited by 28
Channel-Wise Interactive Learning for Remote Heart Rate Estimation From Facial Video
Li, Q., Guo, D., Qian, W., Tian, X., Sun, X. N., Zhao, H., & Wang, M. (2023) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/tcsvt.2023.3332408 · Cited by 27
Impact of makeup on remote-PPG monitoring
Wang, W., & Shan, C. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab51ba · Cited by 27
Wu, B., Wu, Y.-C., & Chou, Y.-W. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3141149 · Cited by 29
BVPNet: Video-to-BVP Signal Prediction for Remote Heart Rate Estimation
Das, A., Lü, H., Han, H., Dantcheva, A., Shan, S., & Chen, X. (2021) · International Conference on Automatic Face and Gesture Recognition · doi:10.1109/fg52635.2021.9666996 · Cited by 27
A Real-Time Contactless Pulse Rate and Motion Status Monitoring System Based on Complexion Tracking
Lin, Y.-C., Chou, N., Lin, G., Lin, G., & Lin, Y.-H. (2017) · Sensors · doi:10.3390/s17071490 · Cited by 28
Quality metric for camera-based pulse rate monitoring in fitness exercise
Wang, W., Balmaekers, B., & de Haan, G. (2016) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2016.7532795 · Cited by 27
Self-citationVideo-based Contactless Blood Pressure Estimation: A Review
Lu, Y., Wang, C., & Meng, M. Q. ‐. (2020) · IEEE International Conference on Real-time Computing and Robotics (RCAR) · doi:10.1109/rcar49640.2020.9303040 · Cited by 26
Continuous Camera-Based Premature-Infant Monitoring Algorithms for NICU
Nagy, Á., Földesy, P., Jánoki, I. G., Terbe, D., Siket, M., Szabó, M., Varga, J., & Zarándy, Á. (2021) · Applied Sciences · doi:10.3390/app11167215 · Cited by 26
Heart rate estimation network from facial videos using spatiotemporal feature image
Jaiswal, K. B., & Meenpal, T. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106307 · Cited by 26
Zhao, C., Zhou, M., Zhao, Z., Huang, B., & Rao, B. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3252091 · Cited by 26
Ivrr-PPG: An Illumination Variation Robust Remote-PPG Algorithm for Monitoring Heart Rate of Drivers
Xu, M. F., Zeng, G., Song, Y., Cao, Y., Liu, Z., & He, X. Y. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3271760 · Cited by 27
Optimal signal quality index for remote photoplethysmogram sensing
Elgendi, M., Martinelli, I., & Menon, C. (2024) · npj Biosensing · doi:10.1038/s44328-024-00002-1 · Cited by 28
Speth, J., Vance, N., Sporrer, B., Niu, L., Flynn, P. J., & Czajka, A. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3476556 · Cited by 25
Al‐Naji, A., & Chahl, J. (2017) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2017.2757485 · Cited by 25
Noncontact Multiphysiological Signals Estimation via Visible and Infrared Facial Features Fusion
Ding, S., Ke, Z., Yue, Z., Song, C., & Lu, L. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3209750 · Cited by 25
Modified RGB Cameras for Infrared Remote-PPG
Wang, W., & Brinker, A. C. D. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.2973313 · Cited by 25
Zhao, C., Zhou, M., Han, W., & Feng, Y. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3169567 · Cited by 24
An Assessment of Algorithms to Estimate Respiratory Rate from the Remote Photoplethysmogram
Luguern, D., Perche, S., Benezeth, Y., Moser, V., Dunbar, L. A., Braun, F., Lemkaddem, A., Nakamura, K., Gómez, R., & Dubois, J. (2020) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw50498.2020.00160 · Cited by 24
Ernst, H., Scherpf, M., Malberg, H., & Schmidt, M. U. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102644 · Cited by 23
Contactless Camera-Based Heart Rate and Respiratory Rate Monitoring Using AI on Hardware
Kolosov, D., Kelefouras, V. I., Kourtessis, P., & Mporas, I. (2023) · Sensors · doi:10.3390/s23094550 · Cited by 26
LSTC-rPPG: Long Short-Term Convolutional Network for Remote Photoplethysmography
Lee, J. S., Hwang, G., Ryu, M., & Lee, S. J. (2023) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw59228.2023.00640 · Cited by 23
A Motion Robust Remote-PPG Approach to Driver’s Health State Monitoring
Wu, B., Chu, Y.-W., Huang, P., Chung, M.-L., & Lin, T.-M. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-54407-6_31 · Cited by 23
Real-Time Temporal Superpixels for Unsupervised Remote Photoplethysmography
Bobbia, S., Luguern, D., Benezeth, Y., Nakamura, K., Gómez, R., & Dubois, J. (2018) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2018.00182 · Cited by 23
Feasibility of assessing ultra-short-term pulse rate variability from video recordings
Finžgar, M., & Podržaj, P. (2020) · PeerJ · doi:10.7717/peerj.8342 · Cited by 23
Morales-Fajardo, H., Rodríguez-Arce, J., Gutiérrez-Cedeño, A., Viñas, J. C., Lagos, J. J. R., Abarca-Castro, E. A., Ramírez, C. I. L., & Vilchis-González, A. H. (2022) · Sensors · doi:10.3390/s22103780 · Cited by 26
Amelard, R., Clausi, D. A., & Wong, A. K. C. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.004874 · Cited by 22
Measuring pulse rate variability using long-range, non-contact imaging photoplethysmography
Blackford, E. B., Piasecki, A. M., & Estepp, J. R. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591587 · Cited by 21
Data-Driven Calibration Estimation for Robust Remote Pulse-Oximetry
van Gastel, M., Verkruysse, W., & de Haan, G. (2019) · Applied Sciences · doi:10.3390/app9183857 · Cited by 22
Self-citationNon-Contact Reflectance Photoplethysmography: Progress, Limitations, and Myths
Špetlík, R., Čech, J., & Matas, J. (2018) · International Conference on Automatic Face and Gesture Recognition · doi:10.1109/fg.2018.00111 · Cited by 22
Non-Contact Atrial Fibrillation Detection From Face Videos by Learning Systolic Peaks
Sun, Z., Junttila, J. M., Tulppo, M. P., Seppänen, T., & Li, X. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3193117 · Cited by 21
RobustPPG: camera-based robust heart rate estimation using motion cancellation
Maity, A. K., Wang, J., Sabharwal, A., & Nayar, S. K. (2022) · Biomedical Optics Express · doi:10.1364/boe.465143 · Cited by 21
Video-based heart rate estimation from challenging scenarios using synthetic video generation
Benezeth, Y., Krishnamoorthy, D., Botina-Monsalve, D. J., Nakamura, K., Gómez, R., & Mitéran, J. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106598 · Cited by 22
Lee, H., Cho, A., Lee, S., & Whang, M. (2019) · Sensors · doi:10.3390/s19153263 · Cited by 21
Spatial-Spectral-Temporal Fusion for Remote Heart Rate Estimation
Kado, S., Monno, Y., 吉崎和徳, Tanaka, M., & Okutomi, M. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2997785 · Cited by 21
Chen, W. '., & McDuff, D. (2020) · ACM Transactions on Graphics · doi:10.1145/3408865 · Cited by 34
Camera-Based Cardiorespiratory Monitoring of Preterm Infants in NICU
Zeng, Y., Yu, D., Song, X., Wang, Q., Pan, L., Lu, H., & Wang, W. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3395314 · Cited by 20
Recent Advances in Atherosclerotic Disease Screening Using Pervasive Healthcare
Luo, J., Yan, Z., Guo, S., & Chen, W. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3081180 · Cited by 20
Fusion Method to Estimate Heart Rate from Facial Videos Based on RPPG and RBCG
Lee, H., Cho, A., & Whang, M. (2021) · Sensors · doi:10.3390/s21206764 · Cited by 20
Gupta, A. R., Ravelo-García, A. G., & Morgado‐Dias, F. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3144677 · Cited by 20
Liu, X., Wang, Y., Xie, S., Zhang, X., Ma, Z., McDuff, D., & Patel, S. (2022) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3517225 · Cited by 20
Peripheral Oxygen Saturation Measurement Using an RGB Camera
Wu, B.-J., Wu, B., Dong, Y.-C., Lin, H., & Li, P. W. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3284196 · Cited by 20
Vital signs estimation in elderly using camera-based photoplethysmography
Caroppo, A., Manni, A., Rescio, G., Siciliano, P. A., & Leone, A. (2024) · Multimedia Tools and Applications · doi:10.1007/s11042-023-18053-3 · Cited by 21
On the Vector Space in Photoplethysmography Imaging
Pilz, C. S. (2019) · IEEE International Conference on Computer Vision Workshops · doi:10.1109/iccvw.2019.00197 · Cited by 20
Botina-Monsalve, D., Benezeth, Y., & Mitéran, J. (2022) · BioMedical Engineering OnLine · doi:10.1186/s12938-022-01037-z · Cited by 20
A Real-Time Evaluation Algorithm for Noncontact Heart Rate Variability Monitoring
Han, X., Zhai, Q., Zhang, N., Zhang, X., He, L., Pan, M., Zhang, B., & Liu, T. (2023) · Sensors · doi:10.3390/s23156681 · Cited by 19
Cluster-Phys: Facial Clues Clustering Towards Efficient Remote Physiological Measurement
Qian, W., Li, K., Guo, D., Hu, B., & Wang, M. (2024) · ACM International Conference on Multimedia (ACM MM) · doi:10.1145/3664647.3680670 · Cited by 19
Zhang, Y., Lü, H., Liu, X., Chen, Y.-C., & Wu, K. (2025) · IEEE Transactions on Image Processing · doi:10.1109/tip.2025.3576490 · Cited by 19
Remote Blood Pulse Analysis for Face Presentation Attack Detection
Heusch, G., & Marcel, S. (2019) · Advances in computer vision and pattern recognition · doi:10.1007/978-3-319-92627-8_13 · Cited by 19
CoSTHR: A Heart Rate Estimating Network With Adaptive Color Space Transformation
Qiu, Z., Liu, J., Sun, H., Lin, L., & Chen, Y. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3170976 · Cited by 18
Measuring Heart Rate Variability Using Facial Video
Martinez-Delgado, G. H., Correa-Balan, A. J., May-Chan, J. A., Parra-Elizondo, C. E., Guzman-Rangel, L. A., & Martínez‐Torteya, A. (2022) · Sensors · doi:10.3390/s22134690 · Cited by 18
Style Transfer with Bio-realistic Appearance Manipulation for Skin-tone Inclusive rPPG
Ba, Y., Wang, Z., Karinca, D., Bozkurt, O. D., & Kadambi, A. (2022) · IEEE International Conference on Computational Photography (ICCP) · doi:10.1109/iccp54855.2022.9887649 · Cited by 19
Das, M., Bhuyan, M. K., & Sharma, L. N. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3287243 · Cited by 17
Engagement-Free and Contactless Bed Occupancy and Vital Signs Monitoring
Song, Y., Li, B., Luo, D., Xie, Z., Phillips, B. G., Yuan, K., & Song, W. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3316674 · Cited by 18
van Gastel, M., Balmaekers, B., Verkruysse, W., & Oetomo, S. B. (2018) · Optical Diagnostics and Sensing: Toward Point-of-Care Diagnostics · doi:10.1117/12.2293521 · Cited by 18
Remote measurement of cardiopulmonary signal using an unmanned aerial vehicle
Al‐Naji, A., Perera, A. G., & Chahl, J. (2018) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/405/1/012001 · Cited by 17
A wavelet-based decomposition method for a robust extraction of pulse rate from video recordings
Finžgar, M., & Podržaj, P. (2018) · PeerJ · doi:10.7717/peerj.5859 · Cited by 19
Ryu, J., Hong, S., Liang, S., Pak, S., Chen, Q., & Yan, S. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105824 · Cited by 18
Noncontact Sensing of Contagion
Khanam, F.-T.-Z., Chahl, L. A., Chahl, J. S., Al‐Naji, A., Perera, A. G., Wang, D., Lee, Y. H., Ogunwa, T., Teague, S., Nguyen, T. X. B., et al. (2021) · Journal of Imaging · doi:10.3390/jimaging7020028 · Cited by 18
Wedekind, D., Malberg, H., Zaunseder, S., Gaetjen, F., Matschke, K., & Rasche, S. (2015) · IEEE International Conference on Electronics and Nanotechnology (ELNANO) · doi:10.1109/elnano.2015.7146950 · Cited by 18
Guo, K., Zhai, T., Pashollari, E., Varlamos, C. J., Ahmed, A., & Islam, M. N. (2021) · Applied Sciences · doi:10.3390/app112210913 · Cited by 17
A Real-Time Remote Respiration Measurement Method with Improved Robustness Based on a CNN Model
Hwang, H., Lee, K., & Lee, E. C. (2022) · Applied Sciences · doi:10.3390/app122211603 · Cited by 17
Blackford, E. B., Estepp, J. R., & McDuff, D. (2018) · Optical Diagnostics and Sensing: Toward Point-of-Care Diagnostics · doi:10.1117/12.2291073 · Cited by 17
Effects of illuminance intensity on the green channel of remote photoplethysmography (rPPG) signals
Guler, S., Öztürk, Ö., Golparvar, A. J., Doğan, H., & Yapici, M. K. (2022) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-022-01175-7 · Cited by 16
Surveillance Camera-based Cardio-respiratory Monitoring for Critical Patients in ICU
Wang, H., Huang, J., Wang, G., Lu, H., & Wang, W. (2022) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi56158.2022.9926954 · Cited by 16
Optimal digital filter selection for remote photoplethysmography (rPPG) signal conditioning
Guler, S., Golparvar, A. J., Öztürk, Ö., Doğan, H., & Yapici, M. K. (2023) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/acaf8a · Cited by 18
Remote Photoplethysmography measurement using constrained ICA
Macwan, R., Benezeth, Y., Mansouri, A., Nakamura, K., & Gómez, R. (2017) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb.2017.7995453 · Cited by 16
Step Count and Pulse Rate Detection Based on the Contactless Image Measurement Method
Lin, Y.-C., & Lin, Y. (2018) · IEEE Transactions on Multimedia · doi:10.1109/tmm.2018.2790172 · Cited by 16
Yue, H., Li, X., Cai, K., Chen, H., Liang, S., Wang, T., & Huang, W. (2019) · Neurocomputing · doi:10.1016/j.neucom.2018.09.100 · Cited by 16
Ryu, J., Hong, S., Liang, S., Pak, S., Chen, Q., & Yan, S. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.26.2.025003 · Cited by 16
Heart Rate Estimation from Facial Image Sequences of a Dual-Modality RGB-NIR Camera
Lie, W., Le, D. Q., Lai, C.-Y., & Fang, Y.-S. (2023) · Sensors · doi:10.3390/s23136079 · Cited by 15
Optimum Wavelengths in the Near Infrared for Imaging Photoplethysmography
Würtenberger, F., Haist, T. J., Reichert, C. C., Faulhaber, A., Boettcher, T., & Herkommer, A. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2897284 · Cited by 15
Luguern, D., Benezeth, Y., Moser, V., Dunbar, L. A., Braun, F., Lemkaddem, A., Nakamura, K., Gómez, R., & Dubois, J. (2020) · International Symposium on Medical Information and Communication Technology · doi:10.1109/ismict48699.2020.9152720 · Cited by 15
A Real-Time and Non-contact Pulse Rate Measurement System on Fitness Equipment
Chou, Y.-C., Ye, B.-Y., Chen, H., & Lin, Y. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3136173 · Cited by 15
Lin, X., Wu, X., Chen, W., Wang, J., & Zhao, C. (2022) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2022.103822 · Cited by 15
Turnip: Time-Series U-Net With Recurrence For NIR Imaging PPG
Comas, A., Marks, T. K., Mansour, H., Lohit, S., Ma, Y., & Liu, X. (2021) · Proceedings - International Conference on Image Processing · doi:10.1109/icip42928.2021.9506663 · Cited by 14
Capraro, G. A., Balmaekers, B., Brinker, A. C. D., Rocque, M., DePina, Y., Schiavo, M. W., Brennan, K., & Kobayashi, L. (2022) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2022.06.001 · Cited by 14
Wu, Y.-C., Chiu, L.-W., Wu, B., Lin, L. L.-C., Ho, T.-H., Chung, M.-L., & Wu, S.-F. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3256470 · Cited by 14
Model-Agnostic Method: Exposing Deepfake Using Pixel-Wise Spatial and Temporal Fingerprints
Yang, J., Sun, Y., Mao, M., Bai, L., Zhang, S., & Wang, F. (2023) · IEEE Transactions on Big Data · doi:10.1109/tbdata.2023.3284272 · Cited by 16
Tong, Y., Huang, Z., Zhang, Z., Yin, M., Shan, G., Wu, J., & Qin, F. (2023) · Measurement · doi:10.1016/j.measurement.2023.113605 · Cited by 14
Rubīns, U., Miščuks, A., & Lange, M. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-5122-7_95 · Cited by 14
Lee, H., Ko, H., Chung, H., & Lee, J. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176648 · Cited by 14
Zhang, C., Tian, J., Li, D., Hou, X., & Wang, L. (2022) · Technology and Health Care · doi:10.3233/thc-thc228036 · Cited by 14
Photoplethysmography imaging algorithm for continuous monitoring of regional anesthesia
Rubīns, U., Spīgulis, J., & Miščuks, A. (2016) · doi:10.1145/2993452.2994308 · Cited by 14
Remote Pulse Estimation in the Presence of Face Masks
Speth, J., Vance, N., Flynn, P. J., Bowyer, K. W., & Czajka, A. (2022) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw56347.2022.00226 · Cited by 14
Agile mobile robotic platform for contactless vital signs monitoringPreprint
Huang, H., Chai, P. R., Ehmke, C., Merewether, G. B., Dadabhoy, F. Z., Feng, A., Thomas, A. J., Li, C., Silva, M. J. T. D., Raibert, M. H., et al. (2020) · doi:10.36227/techrxiv.12811982.v1 · Cited by 15
Remote Respiration Monitoring of Moving Person Using Radio Signals
Choi, J.-H., Kang, K.-B., & Kim, K. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-19836-6_15 · Cited by 13
Wang, W., Wei, Z., Yuan, J., Fang, Y. C., & Zheng, Y. (2022) · PLoS ONE · doi:10.1371/journal.pone.0275544 · Cited by 13
Metadata
- Authors
- de Haan, G., & van Leest, A.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2014-08-27
- Volume
- 35
- Issue
- 9
- Pages
- 1913-1926
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2044935899
- Cited by
- 491
- References
- 16
- Citations by year
- 2026: 39 · 2025: 77 · 2024: 67 · 2023: 56 · 2022: 70 · 2021: 42 · 2020: 28 · 2019: 32 · 2018: 34 · 2017: 26 · 2016: 12 · 2015: 8
- FWCI
- 7.96
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- TU/e Research Portal (publishedVersion, other-oa)
- TU/e Research Portal (submittedVersion)
- TU/e Research Portal (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- remote photoplethysmography, blood volume pulse, motion robustness, RGB color space, pulse rate detection, signal-to-noise ratio, non-contact vital sign monitoring, exercise monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review